Renovation of Existing Eye OT to Modular Eye OT (DHH Category) at Jharsuguda for the year 2025-26
2026_EICCL_124071_3
Bid Identification No-SE-RandB-JSG-13- OF 2025-26
Open Tender
Civil Works - Buildings
Percentage
120 days
Jharsuguda
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
₹37,959
Yes
10 Mar 2026
1 Jan 2026
16 Jan 2026
1 Jan 2026
15 Jan 2026
1 Jan 2026
1 Jan 2026 - 15 Jan 2026
Air Handling Units
AHU : Double skin air handling units Ceiling suspended type, with 2 mm thick thermal break aluminum profile, 43± 2 thick Puf panel having a density not less than 38 kg/m3 Panel shall have 0.6 mm precoated G.I sheet as outer skin and 0.6mm thick plane GI inner skin. The Unit shall be suitable for clean room applications with coving inside. The AHU shall consists of return air mixing chamber, G4 filter section with filter, DX TYPE cooling coil, fan section with DIRECT DRIVE PLUG FAN with TEFC squirrel cage induction motor. Fine filter section with EU7 filter after the fan section. AHU shall be complete with fresh air, return air and supply air dampers. Fan section & filter section shall have service door. 1500 cfm @ 125mm WC SP. To be connected with 5.5 Tr air cooled condensing unit
Exhaust air system with volume control damper, 10 micron filter and ducting with cowl and bird screen and discharge to building shaft. Exhaust air to be taken from AHU after fan section.
AHU Control Panel: Self standing / wall mounted electrical panel constructed out of 16 G CRCA sheet duly powder coated with suitable capacity of main incoming MCCB, bus bar, metering panel consisting of voltmeter, ammeter and outgoing feeders consisting of MCCB/ MPCB, contractors, relays, single phase prevetor for ahus motors, LDB & PDBs complete with on/off trip indication lamps etc. Panel for AHU, ODU
DUCTING: GI ducting 24 swg with all joints sealed with silicon sealant insulated with XLPE rubber insulation with aluminum foil faced and joints with tape including suports all as required and as directed by Engineer-in-charge
Condensing Unit: 5.5 TR Nominal capacity Air cooled condensing unit with single compressor. This will be connected with copper pipes with DX cooling coil inside AHU including Refrigerant copper piping with fittings, expansion valves and insulation and control instrument for condensing unit, all complete.
Dampers: GI volume control damper
Hatch Box: Static Pass Box made of SS 304 construction with UV light and door interlocks, Internal size 600 x600 mm
Differential Pressure Gauge: Magnhelic gauge with GI box with SS cover plate and sensors with necessary tubing
Electricals: LDB/PDB with CMBs, wiring for light, power sockets etc and cabling for AHU, CDU, earthing , 5/15 amp power sockets for OT
OT Pendent Light:
LED Light Panel: OT peripherial light system with 30 W LED with electronic ballast
Laminar Air flow terminal for supply air, aluminum construction with DOP for fixing of H13 HEPA filter for suppply clean air above OT bed. Unit shall have provision for OT lighting arrangement at centre panel (2' x 2') wthout lighting fixture and lights. Size 6' X 4' with 6 nos HEPA filter of 2'x'2'
OT Return air Riser: 80mm thick double skin (PPGI) on both sides with 40±2 kg/m3 density PUF filIed on both sides and central portion RA riser duct, 0.6 mm sheets on both sides. duct 900 x 100 mm made of GI internal for return of airReturn air riser at corners of OT complete with SS 304 grill and volume control damper
OT clean room ceiling system : Walkable double skin false ceiling of 50 mm thick with skin (PPGI) on both sides with 40±2 kg/m3 density PUF filing with 0.6 mm thick sheets on both sides.
Clean room wall panel: 50 mm thick double skin (PPGI) on both sides with 40±2 kg/m3 density PUF filing, 0.6 mm sheets on both sides.
Clean room compatible double glazed windows to be fitted on clean room wall. View Panel size 1000 x 1000 mm with 5 mm toughen glass on both faces
Coving: Wall wall and wall to ceiling Coving
OT SWING DOOR: Supply of Clean room Solid Steel Doors made up of 0.8 mm thick GI sheet, Door leaf 44mm thick, and door frame of 1.2 mm thick G I sheet, with PUF as infill material with Polyester Powder Coated finish with acessoriess such as door closure, D-Handle, SS Hinges, Door Lock, push plates, Automatic Drop Seal, view panel. Single Leaf Door 1000mmx2100mm
OT Hermetically sealed automatic sliding Door. Door core 60 mm thick with 4 mm thick HPCL skin at both sidesof the door to provide better strength and rigidity with PUF infill of 40 kg/m3 density, PUF thickness 52 mm. High grade aluminum extrusion profile to carry door weight. Canopy powder caoted GI sheet with closing caps. Door size - 1500mmx 2100mm
Dismantling brick or stone masonry in clay above 3M height including stacking the useful materials for reuse and removing the debris within 50M lead.
Floor coving 50 R
X-Ray view board mounted on wall with illuminated board for single view of x ray plate. approx size 14" x 17"
Supplying Fitting Fixing Aluminium Door of Recklad Brand
AHU : Double skin air handling units (8.5 TR) ceiling suspended type , with 2 mm thick thermal break aluminium profile, 43±2 thick puf panel having a density not less than 38 kg/m3 panel shall have 0.6mm precoated G.I sheet as outer skin and 0.6mm thick plane GI inner skin. Fine filter section with EU7 filter the fan section. AHU shall be complete with fresh air, reture air and supply air dampers. Fan section & filter section sha;ll have service door. the AHU will have fresh air module with 10 micron filter & aluminium low leakge damper of required capacity.
Surgeon control panel with humidity control sensor.
2 BAY SS scrub sink, length- 4 feet. Supply and installation of 2 Bay scrub sink with automatic sensor operated mechanism.Anti splash metal body constaruction made of stainless steel grade 304 polished finished.
Electrical sub- panel
Power cable for Power supply
S/F of double Arm Anesthesia pendent.
Double arm Anasthesia pendent with surgeon control.
Point wiring for anasthesia pendent,OT perdant focus Light etc.
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.11 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.33 MB
BOQ_574049.xls
BOQ • 0.29 MB
DTCN04.pdf
Tender Documents • 7.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .