| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.1 L+₹21,700 (7.46%)Rejected-Finance 68 A PUSHPRAJ COMPLEX NR JASHODA CROSS ROAD VATVA AHMEDABAD AHMEDABAD GUJARAT 382445 | AHMADABAD | GUJARAT | 382445 | L2 | Rejected-Finance Not Lowest
Bidder. | |
| 3 | Rejected-Technical 7 1 3RD AND 4TH FLOOR MAGADI MAIN ROAD NEAR MAGADI ROAD METRO STATION NEAR MAGADI ROAD METRO STATION BANGALORE KARNATAKA 560023 | BENGALURU URBAN | KARNATAKA | 560023 | - | Rejected-Technical Not Eligible | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Eligible | |
| 5 | Rejected-Technical | - | Rejected-Technical Not Eligible |
Tender Value
Refer Docs
EMD Value
₹6,533
Closing Date
31 Jan 2022, 6:00 pmClosed
AGM Engg Ele, AAI, Hubballi Airport
Airports Authority of India, Gokul Road, Hubballi Airport, Hubballi
ARMO Works 2021 22 SH Testing and calibration and servicing of protective Relays Metering Devices and HT LT Breakers and panels at Hubballi Airport
2022_AAI_100841_1
AAI/HUB/ENGG-E/NIT/RELAY CAL/2021-22/
Open Tender
Electrical Works
Item Rate
90 days
Hubballi Airport
Please refer Tender document
10 documents required · 10 mandatory
₹1,120
₹6,533
23 Apr 2024
10 Jan 2022
2 Feb 2022
10 Jan 2022
31 Jan 2022
10 Jan 2022
10 Jan 2022 - 18 Jan 2022
Amount
SH : 1 - Testing, calibration of protective Relays and Metering Devices. Testing, callibration and recommissioning of analog relay set ( 3 over current + 1 Earth fault) of models eg REJ601( ABB), etc. with secondary injection kit etc. complete as required.
Testing, callibration and recommissioning of analog relay set master trip, , PQ8nCH2J(ABB) etc. with secondary injection kit etc. complete as required.
Testing, callibration and recommissioning of analog relay set bush trip /alarm trip of models eg CU2D2J (ABB) etc. with secondary injection kit etc. complete as required.
Testing, callibration and recommissioning of digital AMF controller etc. complete as required.
Testing, callibration and recommissioning of Restricted /standby Earth fault relay with phantom loading etc. complete as required.
Testing, callibration and recommissioning of digital power analyzer / Multi function meter with secondary injection kit etc. complete as required.
Testing, callibration and recommissioning of analogue / digital ammeter( Conzerv / AE / Meco/ secure/Rishabh/ABB/Schnider EIC etc.) with phantom loading etc. complete as required.
Testing, callibration and recommissioning of analogue / digital volt meter( Conzerv / AE / Meco/ EIC/secure/Rishabh/ABB/Schnider etc.) with phantom loading etc. complete as required.
Testing, callibration and recommissioning of single core or double core current transformers for protection relays or metering ckts of HV/ MV Installations with secondary injection kit etc. complete as required.
Testing, callibration and recommissioning of Transformers protection Relay of Model no :-TR7570 make Power Electronics & Control for dry type of transformer.secondary injection kit etc. complete as required.
Testing, callibration and recommissioning of digital APFC Relay (EPCOS/L&T / syntron / PTL/ AE) etc. complete as required.
Testing & Calibration of 5 KV Megger, Make:- Motwani.
Testing & Calibration of Multi meter cum Clamp meter, Make:-Fluke
Testing & Calibration of Digital Earth tester Make:-Motwane,Model No:-DET-20
Testing & Calibration of Lux meter Make:- Amprobe,Model No LM-120
Testing & Calibration of Digital Sound meter Make:-Fluke
Testing & Calibration of Temperature & Humidity meter Make FLUKE, Model No 971.
SH:2- HT & LT Breaker/ Panel servicing & Overhauling. Servicing of 5 Panel 11 KV VCB (Make:-ABB, Model:- VD4 12.12.25) through OEM/ its Authorized Dealer by clearing, Checking, tightening, adjusting, replacing defective components, aligning, lubricating, greasing and complete health check of control wiring of HT panel etc complete as required without spare parts. (VCB Capacity-800A, I/C-2nos, O/G-2nos & B/C-01no )
Servicing of 630 Amps -2500 Amps ABB Make MV Circuit Breaker through OEM or its authorized dealer by cleaning , checking, tightening, adjusting replacing defective components greasing oiling etc complete as required but without spare parts i/c Over load, Earth Fault, Short Circuit and Megger Testing through secondary injection kit etc complete as required.
NS ENGINEERS
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .