Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.3 LAccepted-Finance | L-1 | Accepted-Finance L-1 accepted | |
| 2 | L-2₹2.4 L+₹4,872 (2.12%)Rejected-Finance 1 3104 KUNJ GALI RAM NAGAR EXTN LONI ROAD SHAHDARA DELHI 32 | SHAHDARA | DELHI | 110032 | L-2 | Rejected-Finance L-2 rejected |
Tender Value
Refer Docs
EMD Value
₹4,600
Closing Date
10 Aug 2022, 12:00 pmClosed
Ex. Engineer (Elect)-II
OFFICE OF THE Ex. ENGINEER (ELECT)-II, SHAHDARA (N) ZONE, Keshav Chowk, Delhi-110053
Construction of Safai Karamchari Shelter Near Dispensary at 4 1/2 Pusta Sonia Vihar in Ward No. 60-E Shahdara (North) Zone Sub Head Provision of Electrical Installations and Fans
2022_EDMC_124602_1
EEE-II/Sh.N/MCD/22-23/TC-03/3
Open Tender
Electrical Works
Item Rate
90 days
As per NIT
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
₹4,600
25 Aug 2022
3 Aug 2022
11 Aug 2022
3 Aug 2022
10 Aug 2022
3 Aug 2022
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular type switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc. as required.. Group C
Wiring for light/ power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. (a) 2x2.5 sqmm + 1x2.5 sqmm earth wire
(b)2x6 sqmm + 1x6 sqmm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections etc. as required. (a) 5/6 amps switch
(b) 3 pin 5/6 amp socket outlet
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing anf fixing 6 pin 5/6 and 15/16 A modular socket outlet and 15/16 A modular switch connections etc as required.
Supplying and fixing following way, single pole and neutral , sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a) 6 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 63 amps
Supply and fixing 25A rating double pole,(single phaseand neutral) 240 volts, residual current circuit breaker(RCCB) having a sensitivity current 30mA in the existing MCB DB complete with connection testing and commissioning etc as required.(40 amp)
supply, installation, Testing and commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Currect (BLDC) Motor, class of insulation:B, 3 nos blades, 30 cm down rod, 2 nos. canopies, shackle kit, safety ropr, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, Earthng etc. complete as required.
Supply of 12"(300 mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter , blade etc as requird
Installation of exhaust fan in the existing opening, including making good the damage, connection testing, commissioning etc as required.(upto 450 mm sweep)
"SITC of 60w LED Flood Light luminiare fitted with lens, made of pressure die cast aluminum housing & toughened glass cover complete with the following specification as reqd. (b) Total system wattage = 60 watt+/-5% (c) Total Lumens output>=15000 lumens (d) Luminaire Efficacy>=100 Lm/w (e) power factor>=.95 (f) Protection Class-IP-66
P&F Hot press sheet moulded compound (SMC) fire retardnt(Temp. resistant upto 200 C), IP 55 weather proof pole box of inner dimension 200x150x100mm(NS) complete with arrangement for fixing of 1 nos of 6 to 32 amp single pole MCB & (MCB/Isolator excluded) with neutral link duty shorting on DIN channel with 2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc s reqd.
SITC of surface mounting LED luminaire suitable for 1X20 watt LED rating box type complete with extruded aluminium batten prewired with high efficient LEDs with the following: a) Total System Wattage 20 ±5% Watt b) Luminaries effucacy ≥ 100 lumens/watt c) Power factor ≥ 0.95
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Up to 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sq. mm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Supplying and laying of 63 mm dia (OD-63 mm & ID-51 mm nominal)size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
Supply and f of XLPE insulated and PVC Sheathed Al conductor armoured cables for working voltage upto 1.1kv conforming to IS7098 (Part-I) /1998 as required. .a 2x10sqmm
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
Providing & laying earth connection from earth electrode with 6SWG dia G.I. wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supply and fabrication of pole protection system made up of 8SWG steel wire mesh of size25mmx75mm rectangular with 50mmx50mmx6mm MS angle iron for supporting the mesh and grounding the protection system in suitable quality of CC etc as reqd.
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitablemethod prescribed in IS: 2800 (part I), including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All type of soil 200 mm dia
Supplying, assembling, lowering and fixing in vertical position in bore well,unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings& accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.125 mm nominal size dia
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge 125 mm nominal size dia
Development of tube well with suitable capacity of air compressor i/c lowering of necessary induction pipe or line i/c cost of fuel,hire charges of compresser etc as reqd. The development shall be considered complete when Gravel stop sinking, Discharge ceased to improve and the sand contents are not more than 10 PPM after 20 minutes of starting the pump complete as reqd.
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts f required size complete. 150 mm dia
Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm dia
Supply,lowering and fixing following size of G.I. Pipe (M-Class) i/c cutting threading on both sides etc.. ISI marked etc as reqd. a) 25mm(nominal bore)
Supply,lowering and fixing following size of G.I. Pipe (M-Class) i/c cutting threading on both sides etc.. ISI marked etc as reqd. a) 32mm(nominal bore)
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore.
S & F following size G.I socket as required. 25 mm
S & F Following size G.I Union 32mm
S & F Following size of G.I Elbow as reqd.
Gravel packing in tubewell construction in accordance with IS:4097,including providing gravel fine/medium/coarse, in required grading & sizes as per actual requirement,all complete as per direction of Engineer-in-charge
Supplying, lowering, testing and commissioning of following capacity vertical type, multistage, totally enclosed, water filled, deep well submersible pumping set complete i/c connections etc as reqd. Elec92.a Single phase 1.5 HP, having discharge of 72 LPM (approx.) at 49 M head.
Supplying and laying following sizes of steel flexible rope suitable for holding submersible pump set i/c clips etc as reqd. 6 mm dia steel rope.
P and F following sizes of PVC insulated and PVC sheathed copper conductor 3 core submersible cable confirming to IS.694/1990 etc. as reqd. a 3 X 2.5 sq.mm.
Supply, Installation, testing and commissioning of cubical type control panel board for single phase submersible pumping set of following rating complete with contactor, relay , MCB ,condenser ,voltmeter, ammeter and indication lamp etc including connections etc as reqd. 1.5 H.P rating Submersible P/Set.
G D Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .