Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.5 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹10.7 L+₹20,906.70 (1.99%)Rejected-Finance | L2 | Rejected-Finance Being 2nd lowest | |
| 3 | L3₹11.1 L+₹59,086.75 (5.63%)Rejected-Finance 11 GURU NANAK MARKET AMBALA ROAD SAHARANPUR 247001 | SAHARANPUR | UTTAR PRADESH | 247001 | L3 | Rejected-Finance Being 3rd lowest | |
| 4 | L4₹13.4 L+₹2.9 L (27.4%)Rejected-Finance | L4 | Rejected-Finance Being 4th lowest | |
| 5 | L5₹14.4 L+₹3.9 L (36.8%)Rejected-Finance | L5 | Rejected-Finance Being 5th lowest |
Tender Value
Refer Docs
EMD Value
₹34,300
Closing Date
30 Nov 2020, 6:00 pmClosed
SHRI B K SREEKUMAR EE GE (AF) SARSAWA
Garrison Engineer (AF) Sarsawa, Distt. Saharanpur (U.P)
PROVN OF HARD STANDING AND SHED ALONGWITH ASSOCIATED WORKS FOR SWM AND HARD STANDING FOR P-IV ARRESTER BARRIER AND LIGHTING PROTECTION AT AF STN SARSAWA
2020_MES_386436_2
8120/SAR-40/E8 PROVN OF HARD STANDING AND SHED ALO
Open Tender
Civil Works
Item Rate
333 days
GE(AF) SARSAWA
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE(AF) SARSAWA
₹34,300
Yes
15 Dec 2020
13 Nov 2020
2 Dec 2020
13 Nov 2020
30 Nov 2020
18 Nov 2020
13 Nov 2020 - 18 Nov 2020
Amount
M&L for Surface excavation in soft/loose soil n exc 30cm depth and averaging 15cm depth including removal of soil n exc 1.5m deep and getting out in soft/loose soil complete all as specified and as directed.
M&L for Excavating over areas n exc. 1.5m deep and getting out in soft/loose soil complete all as specified and directed.
M&L for Removing excavated soft/loose soil n exc 50m and depositing where directed at a level n exc 1.5m above the starting point as directed by Eng-in-Charge.
M&L for Excavating in trenches in soft/loose soil,exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and as directed.
M&L for Excavation in post holes each n.exc 0.5 cum, getting out, returning, filling in and ramming earth in layers n exc 25cm, watering and removing surplus soil to a distance n exc 50m and making good complete all as specified and as directed.
M&L broken stone or boulders for hardcore of gauge n exc 63mm,deposited,spread and levelled in layers n exc 15mm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for plain cement concrete 1:2:4 ,type B-2 using 40 mm graded crushed stone aggregate in foundation filling and mass concrete complete all as directed.
M&L for 100mm thick plain cement concrete in foundations filling and mass concrete type D-2(1:4:8)(using 40 mm graded aggregate) complete all as directed.
M&L for 150mm PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in sub base of floors complete all as directed as specified..
M&L for sand filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as directed.
M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and as directed.
M&L for Brick work using fly ash bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 complete all as specified and as directed
M&L for 15mm thick cement plastering in cement mortar 1:4 on brick/concrete surface, finished even and even smooth (without using extra cement) complete all as specified.
S&F Mild steel angle,steel square,tubular section with connecting plate(including welding) as required at site including welding complete all as directed.
M&L for preparation of new steel surfaces of any description not otherwise described over 10 Cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
M&L for 200mm thick PCC M-25 using 20 mm graded stone aggregate as in floor complete all as directed as specified.
M&L for 100mm thick cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in floors including finishing even and smooth without using any extra cement complete all as directed as specified..
M&L for Preparation of new plastered surfaces of wall and applying two coat of cement base paint white or tinted complete all as specified and directed of any tintm complete all as specified and as directed.
M&L Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in ridges fixed with self tapping screws as specified and as directed
S&F prepainted galvallume aluminium zinc coating GI based semicorugated steel shees 0.50mm thick and approved coloured having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping stainless steel screws all as per manufacturer instruction complete and as directed
Excavation in trenches in any type of soil, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cable complete all as specified and directed.
Material and labour for sand cushioning with layer of dry, clean & fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed by Engr-in-Charge.
Material and labour for Brick protection with sub class 'B' bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and directed.
S&F GI pipe 50 mm bore light grade for protection of cable /on wall/underground/road/on pole/flour all as specified & directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 70 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
Supplying, laying, jointing, testing and commissioning under ground XLPE LT electric cable 1100 Volts grade, heavy duty, PVC insulated and sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 95 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape including taking down/out of old cable as existing on site complete all as specified and as directed.
Labour for augering upto 100 mm bore for road crossing 3 mtr to 10 mtr not exceeding 1.5 mtr in depth for laying of electric cable and GI tubing in soft/loose soil complete all as specified.
Supply and fixing change over switch cap 125 Amps 3 Phase make: Havells/L&T/ Schneider/ABB complete all as specified and as directed.
Supply and fixing main switch cap 125 Amps 3 Phase of side handle complete all as specified and as directed.
Supply only 25 mt long 2.5 cm wide and at least 0.125mm wall thickness PVC tape of good quality all as specified and directed.
Supply only 25 mt long 2.5 cm wide and at least 0.200mm wall thickness HT tape with adhesive of good quality all as specified and directed.
Supply, transporting to site, errecting and fixing in position 9 metre long, Steel tubular swaged poles complete with cast iron/mild steel base plate, finial taper plug, bolts, nuts washers & screws as specified, type 410, SP-31 IS 2713 marked, drilling of necessary hole including painting to steel tubular poles, with two coats of aluminium paint over a coat of red oxide primer on exposed surface of poles and with black bituminous paint on portion of pole embedded in concrete and painting 3 Nos bands/strips with fluorescent PO red synthetic enamel paint 30 cms wide strip at 30 cms spacing from plinth block and numbering of poles complete all as specified and directed by Engineer-in-Charge.
M&L broken stone or boulders for hardcore of gauge n exc 63mm,deposited,spread and levelled in layers n exc 15 cm thick,watered and rammed to a true surface complete all as specified
M&L for earthing with galvanised steel earth plate electrode 60cmx60cmx6mm thick surrounded by charcoal & salt buried directly in ground (earth pit not less than 2.25m below ground level) with top edge of the earth plate not less than 1.5m below normal ground level, connected to and including GI strip of size 25x4mm as earthing lead upto 7.5m length by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 3 of SSR Part-I 2009 connected to earthing test point/ transformer/ panel and testing on completion including necessary excavation, returning filling, disposal of surplus soil upto 50m lead in any type of soil, funnel, PCC chamber (1:3:6) type C-1, RCC pit cover, charcoal, salt including provision of earth lead protected by 40 mm dia light grade GI pipe (ISI marked), upto 7.5m length and 20mm dia medium grade GI pipe (ISI marked) for watering complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc as required 25x4mm galvanised iron strip complete all as specified and directed.
S&F lighting arrester spike fixed on 3-5mtr(as user required) Length 40 mm dia GI pipe complete all as specified and directed.
S & F Earth continuity conductor or main earthing lead with 8mm dia galvanised iron or steel wire fixed as specifed and directed
NAQLI LAL SHARMA AND ARUN SHARMA
RAJAN TRADERS
M/s Inderlal
BRIJ CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .