Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.3 LAccepted-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC LOWEST QUOTED BIDDER | |
| 2 | L2₹28.3 L+₹20,876 (0.74%)Rejected-Finance | L2 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 3 | L3₹29.8 L+₹1.7 L (6.20%)Rejected-Finance | L3 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER | |
| 4 | L4₹33.7 L+₹5.6 L (19.9%)Rejected-Finance | L4 | Rejected-Finance NOT THE LOWEST QUOTED BIDDER |
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
29 Sept 2021, 6:00 pmClosed
CWE AF SECUNDERABAD
CWE AF SECUNDERABAD Bowenpally Post Secunderabad 500011
SPECIAL REPAIRS AND REPLACEMENT OF LT OVER HEAD LINES AND DILAPIDATED ELECTRIC POLES AND PANEL BOARDS FROM VAMPIRE TRIANGLE TO KAKATIYA GUEST HOUSE ALONGWITH CONNECTED WORKS AT AFA HYDERABAD
2021_MES_470672_1
86656/E8
Open Tender
Civil Works
Item Rate
180 days
GE AFA HYDERABAD
AS PER NIT
9 documents required · 9 mandatory
₹500
GE AFA HYDERABAD
₹62,000
Yes
9 Oct 2021
26 Aug 2021
1 Oct 2021
26 Aug 2021
29 Sept 2021
15 Sept 2021
26 Aug 2021 - 10 Sept 2021
Amount
Excavation in trenches in soft / loose soil not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables etc complete all as specified and as directed.
M&L for River dry sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punned thickness up to 18 cm and consolidation, complete all as specified and as directed.. Note :- Punned thickness only will be considered for payment.
Returning, filling in trenches in any kind soil in layers not exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and as directed.
M&L for bricks sub class 'B' locally available best quality laid in trenches above sand cushioning for cable protection complete all as specified and as directed.
Removing surplus excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed
Dismentaling of ACSR or AAC conductor of any size Complete all as specified and as directed
Supply, laying and testing cable LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4.0 core complete all as specified and as directed.
Supply, laying and testing cable LT XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4.0 core complete all as specified and as directed.
Dismentaling of PCC Poles including coping of any size complete all as specified and as directed
Supply and fix steel tubular swaged poles complete with CI base plate and finial taper , plugs bolts, nuts and screws as specifed type410 SP-37 (9.5 meter long) including applying two coats of Aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Dismantaling of Sub main / service cable of any size complete all as specified and as directed
Supply, laying and testing Cable flexible, PVC Insulated ,PVC Sheethed 1100 Volts grade with stranded Copper conductor of size 1.5 sq mm 2.0 core drawn through Pipe / Pole including aluminum binding wire 2 mm dia complete all as specified and as directed.
Taking down GI Pipe of any size and in any position complete all as specified and as directed.
M&L for GI tubing light grade 20 mm bore for protection of service connection for protection of connection wire from junction box to street light fittings complete all as specified and as directed. (Note :- Necessary clamps, nuts, bolts etc deemed to be included in the quoted rate)
M&L for GI tubing light grade 40 mm bore galvanised,with all fitting;laid in trenches on pole / wall / exisiting pipe for cable protection complete all as specified and as directed.
M&L for GI tubing light grade 50 mm bore galvanised,with all fittings laid in trenches on pole / wall / exisiting pipe for cable protection etc complete all as specified and as directed.
M&L for earthing complete with Galvanised steel earth plate eletrode 600 mm x 600 mm x 6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised iron 32 x 6 mm strip connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber of size 45cm X 45cm X 45cm including, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 4 of MES Schedule Part-I (2009) complete all as specified and as directed.
S&F Earthing continuity galvanised iron strip 25 mm x 4 mm or main earthing lead fixed to wall with clamps or recess or croses or buried in ground or drawn in conduits / pipe or fixed to poles or any other indicated situation for loop earthing etc as required including taking out old earth strip complete all as specified and as directed.
Taking out the existing unserviceable street light fittings any type complete all as specified and as directed.
S&F LED Street light fitting 30 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution suitable for 40 mm outer dia GI pipe and connecting up etc complete all as specified and as directed. Make :- Luker cat part No LSTE -30 / Crompton Cat Part No:- LSTS-30-CDL / Havells Cat Part No:- ENDURACITYLITEPLATPLUSSL30W LED 757SASYBOPC / Bajaj Cat Part No:-BCLST 30W LED-I
S&F LED Street light fitting 45/48 Watt LED pressure die cast aluminum housing heat resistant toughened glass with frame, IP - 66 protection, uniform distribution suitable for 40 mm outer dia GI pipe and connecting up etc complete all as specified and as directed. Make :- Luker cat part No LST -48 / Make:-Crompton Cat Part No:- LSTP-45-CDL / Havells Cat Part No:- ENDURACITYLINERNEXGENSL45WLED757SASYBOPC / Bajaj Cat Part No:-BRTFG 45W LED-I
Design, supply, erection, testing and commissioning of outdoor type LT feeder pillar box platform mounted (to be mounted on the P.C.C. brick pedestal), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating not less then 100 amps, Spreader link to incoming/outgoing MCCB for termination of incoming/outgoing cable and Aluminium connecting bars of suitable size (R-Y-B-N) for outgoing cables, duly fabricated in a CPRI approved / certified factory having modern fabrication and testing facility which includes at least seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron)with approved shade of RAL 7032.
The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel angle (50x50x5mm) legs of length 30 cm at bottom, suitable for mounting on the pedestal, The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation, complete all as specified and as directed. The feeder pillar shall be comprising of the followings :- (NOTE :- Including dismantling old Feeder Pillar Box of any size)
(i) MCCB 4 pole 63 Amps, 25 KA, 415 Volts - 01 Nos
(iv) MCB,TP,63A,10kA-02Nos
(v) Astronomical time switch daily 1 channel having in built mechanism for calculating sun rise /sun set timing of a particular place suitable for 240 V AC supply - 01 No
(vi) 3 Pole power contactor of AC 3 duty rating of 40 amps having 240 volts rated coil and having 2 NO + 2 NC - 01 Nos
(vii) LED indicating lamps with holder for main supply - 1Set of 3
(viii) Instrumental control wiring with MCB 2 Amps - 03 Nos
(x) ON/OFF Push Buttons -02Nos.
S & F cable junction box 167 x 125 x 82 mm in size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-02 N0 & M- 25 -01 N0 ) fixed on poles with aluminium clamps of size 25 x 3, unts, bolts, washers etc., including taking out of old unserviceable cable junction box complete all as specified and as directed Make :- HENSEL Cat No . K-8100 of or equivalent in aproved make.
S & F cable junction box 200 x 160 x 98 mm in size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-02 N0 & M- 25 -01 N0 ) fixed on poles with aluminium clamps of size 25 x 3, nuts, bolts, washers etc., including taking out of old unserviceable cable junction box complete all as specified and as directed Make :- HENSEL Cat No . K-8250 of or equivalent in approved make.
S&F of Street light Bracket up to 2.0 mtr long made with GI Pipe light grade 40 mm dia with all fittings as required on pole with clamps and nut bolts etc including taking down old brackets complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 mix using 20 mm graded stone aggregate as in platform, filling and mass concrete, coping to pole for embedding stay rod , including necessary form work and applying two coats of white wash to exposed surface of coping / platform complete all as specified and as directed .
M&L for Boring of holes under road, pavement hard standing by using trenchless technology using ultrasound technique and necessary machine to insert pipe of 80 mm light grade GI pipes with all fittings such as bends, elbows, Tees, etc, for protection of cable complete including all plant & machinaries, alongwih Butt fusion welding machine with all accessories, T&P etc as required complete all as specified and as directed. Note :- Protection pipe will be measured and paid separately
Taking down cross arms bracings of any size any type complete all specified and directed
M&L for PCC 1:3:6 type C-2 mix using 40 mm graded stone aggregate as in foundations / platform / pedestal / stay wire etc, complete all as specified and as directed .
Srinivasa Consructions
M.chandraiahsons
Srinivash Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .