Accessories Division, Lucknow
HINDUSTAN AERONAUTICS LIMITED Accessories Division, Lucknow Post Office, Lucknow - 226 016 Uttar Pradesh, India
Passive Network Component-Optical Fiber Network backbone at HAL Lucknow
6863
HAL-ADL/Maint-Plg/CWA-23IT/2/07
Works
Accessories Complex - Lucknow Divn - Plant Maintenance
₹0
₹60,060
25 Apr 2024
4 Apr 2024
4 Apr 2024
25 Apr 2024
ANNEXURE-B Passive Network Components-Optical Fiber Network backbone at HAL, Lucknow (HAL-ADL/Maint-Plg/CWA-23IT/2/07, date: 04.04.2024)
ELIGIBILITY CRITERION
Estimated Cost (in Rs.) 3,002,988.00
S# Intending bidders must meet the following eligibility criterion: Remarks to be filled by Bidder
1 Contractor must give his acceptance to provide services as per ‘Requirement, Scope of work and ‘Terms & Conditions'.
2 Registration with HAL/ other organization/Legal entity (Proprietorship/Partnership/Registered firm as per companies act etc.)
3 Self attested copy of PAN/GIR No. Registration certificate issued by income tax authority.
4 Sel attested Copy of GST Registration Certificate.
5 Annual Financial Report (Balance Sheet & Profit & Loss Account) of last 03 years i.e. Fin Year 2020-21, 2021-22 & 2022-23
6 The Solvency required will be 40% of the approx. estimated amount put to tender. The solvency certificate shall be from a nationalized or scheduled bank and issued within a period of 12 months from the final date of Submission of tender.(in Rs.) 1,201,196.00
6.1 Tender Cost (in Rs.) Nil
6.2 EMD amount (in Rs.) Firms exempted from submission of EMD must attach a certified copy of GOT's authority (at e-portal) allowing for such exemption in liew of tender fee/EMD. The offers without EMD/ EXEMPTION certificate shall be considered as unresponsive and rejected. 60,060.00
7 Tender Cost is to be submitted in the form of DD/ Bankers Cheque/Pay Order drawn in favor of Hindustan Aeronautics Limited, Accessories Division, payable at Lucknow from a Nationalized bank/Schedule Bank with Technical Bid to be submitted to the address mentioned below so as to reach well within time on/before last date & time of submission of BID. However the details of DD no. & date etc. to be provided in the prequalification profile and Original should reach below mentioned office well within date and the time of submission of Tender: Head of the Department (Plant Maintenance) Hindustan Aeronautics Limited, Accessories Division, Faizabad Road,Lucknow-226016. (HAL will not be responsible for any postal delays)
8 Self attested Copy of PF Code Certificate(if applicable).
9 Self attested Copy of ESI Number certificate (if applicable).
10 Experience of having successfully completed similar works as indicated in the work details during last 7 years ending last day of month previous to the one in which applications are invited should be either of the following (in Rs.):-
i Three similar completed each work costing not less than 40% of estimated amount. OR 1,201,196.00 PO no.: Value : Completion Date: Customer:
1,201,196.00 PO no.: Value : Completion Date: Customer:
1,201,196.00 PO no.: Value : Completion Date: Customer:
ii Two similar completed work costing not less than the amount equal to 50% of the estimated cost. OR 1,501,494.00 PO no.: Value : Completion Date: Customer:
1,501,494.00 PO no.: Value : Completion Date: Customer:
iii One similar completed work costing not less than the amount equal to 80% of the estimated cost. 2,402,391.00 PO no.: Value : Completion Date: Customer:
1. Similar works implied that works related to HT/LT Electrical Works in nature. Mere supply of electrical goods does not mean qulification in the tender. 2. Scanned copy of completed work orders and completion certificate issued by respective clients to be attached. If the completion certificate is form private organization the same shall be uploaded with TDS certificate. 3. The work shall be completed as a whole, Partial value/completion will not be considered. 4. The Bidders are requested to attach scan copies of all the relevant / desired / required proofs/ documents on e-portal, failing which tender shall be summarily rejected without assigning any reason to bidders.
Name of vendor:
ANNEXURE-A Passive Network Components-Optical Fiber Network backbone at HAL, Lucknow (HAL-ADL/Maint-Plg/CWA-23IT/2/07, date: 04.04.2024)
INSTRUCTIONS TO BIDDERS
S.N. CLAUSE Bidder Confirmation (Complied/ NOT Complied).
1 Please submit your Quotation for following items in Two parts (Price & Technical Bid) in the prescribed format uploaded on e-portal.
2 No hard copy of the offer is to be sent.
3 Scan copy of DD/Bankers Cheque/ pay order of EMD (Refundable) is to be uploaded on the portal and original to be dispatched by post in order to reach us prior to tender closing date & time as indicated in RFQ, Failure in receipt of original EMD before tender opening will result in rejection of offer. For any postal delay HAL will not be held responsible.
Please mention following information on envelope carrying EMD
1) Title: EMD against e-tender.
2) Tender No. & Due Date.
3) Tender Description.
4) Complete Name & Address of the firm submitting EMD
Please dispatch the Original EMD at following address:
Additional General Manager (Maintenance) Hindustan Aeronautics Limited, Accessories Division, Faizabad Road,Lucknow-226016.
4 Kindly note that EMD should be in the form of demand draft/Bankers Cheque/pay order only should be in the name of "Hindustan Aeronautics Limited, Accessories Division" payable at Lucknow.
5 Un priced Bid shall be opened as per schedule indicated on e-portal.
Return of Earnest Money Deposit. EMD shall be refunded to unsuccessful bidders after evoluation of L-1 vendor and award of order. For successful bidder, the EMD will be adjusted towayds security deposit.
EMD will be forfeited in following cases: a) If a bidder withdraws its Bid during the period of Bid validity specified by the bidder in the Bid Or b) If a successful bidder fails: i) To sign the Agreement in accordance with HAL. ii) To furnish performance security as asked by HAL.
6 No request for transfer of any previous deposit of earnest money or security deposit or adjustment against any pending bill held by the HAL in respect of any previous work shall be entertained.
7 You should quote price per unit and total price in figures & in words.
8 If you are unable to quote, please submit regret response.
9 Disregard of any instructions/Conditional offer will be rejected.
10 In case of any ambiguity in the tender documents, HAL works manual will be followed which is available and can be downloaded from our website www.hal-india.co.in.
11 Validity of offer should be at least 90 days from the date of opening of tender.
12 Vendors are requested to kindly visit the site www.hal-india.co.in for any corrigendum/addendum & other tender related information regularly.
Name of Vendor:
Passive Network Components-Optical Fiber Network backbone at HAL, Lucknow (HAL-ADL/Maint-Plg/CWA-23IT/2/07, date: 04.04.2024)
S# DESCRIPTION UNIT TOTAL QTY RATE (In Rs.) AMOUNT (in Rs.)
A Work Description: It is required to extend the existing OFC backbone for local area networking. Work involved under OFC laying and establishment of LAN network on supply installation testing & commissioning (SITC) basis. The requirement is on turnkey package basis.
1 Optic Fiber Cable-Armoured, Single mode (SM), OS2, 24 fiber core, outdoor armoured HDPE jacket suitable for direct burial, waterproof, which can support upto 10G network and as per ISO/IEC/ITU-T standards. Make: D-Link, Digilink, Digisol. Mtrs 4000
2 Supply and installation of Network Rack - 19"inch 15U, wall mount, steel rack, depth upto 600 mm, 1 half tray, front transparent toughened glass, secure lock, Verticle & horizontal managers, AC power distribution strip indian 3-pin 5A 6 nos. socket with fuse and on/off control, min. 1 nos. of cooling fans, wall mounting kit. Work involves fixing on wall and installation of all required active and passive components as per site requirements. Make: D-Link / Netrack / Dynamic Rack / Valrack. Nos. 12
3 Supply and installation of Network Rack - 19"inch 12U, wall mount, steel rack, depth upto 600 mm, 1 half tray, front transparent toughened glass, secure lock, Verticle & horizontal managers, AC power distribution strip indian 3-pin 5A 6 nos. socket with fuse and on/off control, min. 1 nos. of cooling fans, wall mounting kit. Work involves fixing on wall and installation of all required active and passive components as per site requirements. Make: D-Link / Netrack / Dynamic Rack / Valrack. Nos. 4
4 Supply and installation of Fiber Patch Panel (LIU), 1U, 19" Rack Mounted sliding LIU, 12 Ports, fully loaded SC adapters couplers for Single mode OFC. Make: D-Link / Digilink / Digisol. Nos. 6
5 Supply and installation of Fiber Patch Panel (LIU), 1U, 19" Rack Mounted sliding LIU, 8 Ports, fully loaded SC adapters couplers for Single mode OFC. Make: D-Link / Digilink / Digisol. Nos. 18
6 Pigtail SC type simplex single mode for above LIUs. Make: D-Link, Digilink, Digisol. Nos. 288
7 Fiber Optic Patch Cord, Duplex, Singlemode, LC to SC, 2 m, suitable for 10G network. Make: D-Link, Digilink, Digisol. Nos. 36
8 Fiber Optic Patch Cord, Duplex, Singlemode, SC to SC, 2 m, suitable for 10G network. Make: D-Link, Digilink, Digisol. Nos. 15
9 Supply of UTP CAT6 cable, Conductor Diameter 0.57 mm (23 AWG), Conductor Material Bare Copper, Cable Colour Grey, Length of cable in a bundle box 305 Mtrs. (1 Box=305 Mtrs.) Make: D-Link, Digilink, Digisol. Box. 30
10 Supply of UTP Patch cord CAT 6, Length 1 Mtr. Make: D-Link, Digilink, Digisol. Nos. 500
11 Supply of UTP Patch cord CAT 6, Length 2 Mtr. Make: D-Link, Digilink, Digisol. Nos. 365
12 Supply of UTP Patch cord CAT 6, Length 3 Mtr. Make: D-Link, Digilink, Digisol. Nos. 34
13 Supply and Installation of CAT 6 Patch Panel, 4 Ports fully Loaded, 1U, with cable management rear side, suitable for CAT 6 U/UTP. Work may include patch panel punching in new or existing racks and punching of existing UTP cables or as per site requirements. Make: D-Link, Digilink, Digisol, AMP. Nos. 28
14 Supply of RJ-45 Connector for CAT 6 UTP Cable, Color white. Make: D-Link, Digilink, Digisol. Box. 2
15 Supply, installation, fixing of Cat 6 Information Outlet, RJ-45 single port connector, Dust protection, face plate and back box (3x3 inches). Work involves proper fixing to the wall/wall panels or as per site requirements. Make: D-Link, Digilink, Digisol. Nos. 165
16 Supply of HDPE flexible min. 1.5" inch diagonal pipe crack proof weather proof of standard make with necessary jointers/ connectors for under ground laying of power supply cable / OFC / cat 6 data cable as per site requirement. Mtrs 3600
17 Supply of GI pipe min. 2" inch diagonal of standard make with necessary jointers/connectors for under ground laying of power supply cable/OFC/ cat 6 data cable as per site requirement. Mtrs 20
18 Supply & laying of PVC rigid conduit pipe medium with all necessary accessories like long bend, elbow, saddles & screws etc which is required for laying work. The pipe shall be laid as per site requirement i.e. it may be concealed in wall or flush to the wall with fixing of junction boxes as per requirement of site. Work include labour for laying of LAN cables. Size: 25mm diameter. ISI mark. Color:Ivory/off-white only. Make: AKG/CAP/Havells/Anchor Mtrs 4125
19 Supply & Laying of PVC Casing “N” capping double lock (Regular) type and medium duty with all necessary accessories like elbows, coupler, 3 way tee fitting, external bends, internal bends etc. Work include labour for laying of LAN cables. size: 25mmx16mm. ISI mark. Color:Ivory/off-white only. Make: AKG/CAP/Havells/Anchor Mtrs 350
20 Supply of PVC flexible conduit pipe for LAN cables, medium duty, ISI mark, size: 20mm approx. diameter with all required accessories required for installation. Mtrs 20
21 Underground laying of OFC cable by horizontal directional drilling (HDD) OFC cable laying machine and laying / pulling of HDPE pipe coupled by HDPE sockets and sealing of HDPE pipe end by end caps. For HDD cable laying, guided boring/drilling technology is to be used. Detection system should be used for avoiding damage to existing underground utilities. The contractor has to arrange HDD/moling machine at his own arrangement basis. HDD machine shall be capable of going 5 meters or more below the ground level. After laying any excavated work surface to be returned to original state. Work will also include Laying & pulling of OFC cables etc. within HDPE pipe on wall or overhead as per site requirement with the use of clamps for fixing the cable. Mtrs. 3400
22 Digging of hard soil, soft soil, road cutting and laying/pulling OFC/ data cable in GI Pipe / HDPE & Cementing for locations where laying not possible by HDD machine. While road crossing (hard soil) it should be done by cutting the road or manual blowing for laying OFC cable in pipe, after completion of work surface to be returned to original state. Work will also include Laying & pulling of OFC cables etc. within HDPE pipe on wall or overhead as per site requirement with the use of clamps for fixing the cable. Mtrs. 200
23 Labour for wall cutting, wall cut filling & painting to its orginal condition for concealed 25mm PVC pipe as per site requirements Mtrs 150
24 OFC Splicing and termination charges for the complete work for all LIU's SM, Pigtails as per bill of materials. Work involves splicing work for new/old racks as per site requirements. Job 1
25 Dressing of Network Racks including active and passive network components - work involves cleaning, reinstallation of components, Jack Panel punching/repunching, marking tagging & tracing and labelling of connections as per industry practices. Nos. 15
26 Removal of networking racks including removal of old unused UTP Cables, OFC cables, I/O boxes, caping casing, conduit pipes and other accessories including active & passive components at site after complete tracing of live and non-live networking cables. Nos. 6
27 Cable Route markers: Supply and installation of surface markers (stone) to indicate route of the cables shall be planted to mark cable routes and indentify underground fiber optic cables. Display marker should have visible engraved message like "OFC CABLE LAID BELOW" and cable depth. Nos. 20
28 Documentation: Two sets of detail documentation required to be done for showing network architecture with all tagging details, block diagram of network. The documents must be helpful during fault findings and rectificaton. Job 1
29 Warranty: Min. 01 Year for the complete system from the date of final acceptance by HAL-ADL after successful installation, commissioning and demonstration of the system. In case offered OEM warranty is for more than a year without any extra charges then warranty for that item(s) from OEM will be applicable. Nos. 1
Name of Vendor:
Technical Compliance Statement (Scope of Work) Annexure-C
Passive Network Components-Optical Fiber Network backbone at HAL, Lucknow (HAL-ADL/Maint-Plg/CWA-23IT/2/07, date: 04.04.2024)
S# Description UNIT QTY Offered Parameter / Remarks (If Any) Compliance YES / NO
A Work Description: It is required to extend the existing OFC backbone for local area networking. Work involved under OFC laying and establishment of LAN network on supply installation testing & commissioning (SITC) basis. The requirement is on turnkey package basis.
1 Optic Fiber Cable-Armoured, Single mode (SM), OS2, 24 fiber core, outdoor armoured HDPE jacket suitable for direct burial, waterproof, which can support upto 10G network and as per ISO/IEC/ITU-T standards. Make: D-Link, Digilink, Digisol. Mtrs 4000
2 Supply and installation of Network Rack - 19"inch 15U, wall mount, steel rack, depth upto 600 mm, 1 half tray, front transparent toughened glass, secure lock, Verticle & horizontal managers, AC power distribution strip indian 3-pin 5A 6 nos. socket with fuse and on/off control, min. 1 nos. of cooling fans, wall mounting kit. Work involves fixing on wall and installation of all required active and passive components as per site requirements. Make: D-Link / Netrack / Dynamic Rack / Valrack. Nos. 12
3 Supply and installation of Network Rack - 19"inch 12U, wall mount, steel rack, depth upto 600 mm, 1 half tray, front transparent toughened glass, secure lock, Verticle & horizontal managers, AC power distribution strip indian 3-pin 5A 6 nos. socket with fuse and on/off control, min. 1 nos. of cooling fans, wall mounting kit. Work involves fixing on wall and installation of all required active and passive components as per site requirements. Make: D-Link / Netrack / Dynamic Rack / Valrack. Nos. 4
4 Supply and installation of Fiber Patch Panel (LIU), 1U, 19" Rack Mounted sliding LIU, 12 Ports, fully loaded SC adapters couplers for Single mode OFC. Make: D-Link / Digilink / Digisol. Nos. 6
5 Supply and installation of Fiber Patch Panel (LIU), 1U, 19" Rack Mounted sliding LIU, 8 Ports, fully loaded SC adapters couplers for Single mode OFC. Make: D-Link / Digilink / Digisol. Nos. 18
6 Pigtail SC type simplex single mode for above LIUs. Make: D-Link, Digilink, Digisol. Nos. 288
7 Fiber Optic Patch Cord, Duplex, Singlemode, LC to SC, 2 m, suitable for 10G network. Make: D-Link, Digilink, Digisol. Nos. 36
8 Fiber Optic Patch Cord, Duplex, Singlemode, SC to SC, 2 m, suitable for 10G network. Make: D-Link, Digilink, Digisol. Nos. 15
9 Supply of UTP CAT6 cable, Conductor Diameter 0.57 mm (23 AWG), Conductor Material Bare Copper, Cable Colour Grey, Length of cable in a bundle box 305 Mtrs. (1 Box=305 Mtrs.) Make: D-Link, Digilink, Digisol. Box. 30
10 Supply of UTP Patch cord CAT 6, Length 1 Mtr. Make: D-Link, Digilink, Digisol. Nos. 500
11 Supply of UTP Patch cord CAT 6, Length 2 Mtr. Make: D-Link, Digilink, Digisol. Nos. 365
12 Supply of UTP Patch cord CAT 6, Length 3 Mtr. Make: D-Link, Digilink, Digisol. Nos. 34
13 Supply and Installation of CAT 6 Patch Panel, 4 Ports fully Loaded, 1U, with cable management rear side, suitable for CAT 6 U/UTP. Work may include patch panel punching in new or existing racks and punching of existing UTP cables or as per site requirements. Make: D-Link, Digilink, Digisol, AMP. Nos. 28
14 Supply of RJ-45 Connector for CAT 6 UTP Cable, Color white. Make: D-Link, Digilink, Digisol. Box. 2
15 Supply, installation, fixing of Cat 6 Information Outlet, RJ-45 single port connector, Dust protection, face plate and back box (3x3 inches). Work involves proper fixing to the wall/wall panels or as per site requirements. Make: D-Link, Digilink, Digisol. Nos. 165
16 Supply of HDPE flexible min. 1.5" inch diagonal pipe crack proof weather proof of standard make with necessary jointers/ connectors for under ground laying of power supply cable / OFC / cat 6 data cable as per site requirement. Mtrs 3600
17 Supply of GI pipe min. 2" inch diagonal of standard make with necessary jointers/connectors for under ground laying of power supply cable/OFC/ cat 6 data cable as per site requirement. Mtrs 20
18 Supply & laying of PVC rigid conduit pipe medium with all necessary accessories like long bend, elbow, saddles & screws etc which is required for laying work. The pipe shall be laid as per site requirement i.e. it may be concealed in wall or flush to the wall with fixing of junction boxes as per requirement of site. Work include labour for laying of LAN cables. Size: 25mm diameter. ISI mark. Color:Ivory/off-white only. Make: AKG/CAP/Havells/Anchor Mtrs 4125
19 Supply & Laying of PVC Casing “N” capping double lock (Regular) type and medium duty with all necessary accessories like elbows, coupler, 3 way tee fitting, external bends, internal bends etc. Work include labour for laying of LAN cables. size: 25mmx16mm. ISI mark. Color:Ivory/off-white only. Make: AKG/CAP/Havells/Anchor Mtrs 350
20 Supply of PVC flexible conduit pipe for LAN cables, medium duty, ISI mark, size: 20mm approx. diameter with all required accessories required for installation. Mtrs 20
21 Underground laying of OFC cable by horizontal directional drilling (HDD) OFC cable laying machine and laying / pulling of HDPE pipe coupled by HDPE sockets and sealing of HDPE pipe end by end caps. For HDD cable laying, guided boring/drilling technology is to be used. Detection system should be used for avoiding damage to existing underground utilities. The contractor has to arrange HDD/moling machine at his own arrangement basis. HDD machine shall be capable of going 5 meters or more below the ground level. After laying any excavated work surface to be returned to original state. Work will also include Laying & pulling of OFC cables etc. within HDPE pipe on wall or overhead as per site requirement with the use of clamps for fixing the cable. Mtrs. 3400
22 Digging of hard soil, soft soil, road cutting and laying/pulling OFC/ data cable in GI Pipe / HDPE & Cementing for locations where laying not possible by HDD machine. While road crossing (hard soil) it should be done by cutting the road or manual blowing for laying OFC cable in pipe, after completion of work surface to be returned to original state. Work will also include Laying & pulling of OFC cables etc. within HDPE pipe on wall or overhead as per site requirement with the use of clamps for fixing the cable. Mtrs. 200
23 Labour for wall cutting, wall cut filling & painting to its orginal condition for concealed 25mm PVC pipe as per site requirements Mtrs 150
24 OFC Splicing and termination charges for the complete work for all LIU's SM, Pigtails as per bill of materials. Work involves splicing work for new/old racks as per site requirements. Job 1
25 Dressing of Network Racks including active and passive network components - work involves cleaning, reinstallation of components, Jack Panel punching/repunching, marking tagging & tracing and labelling of connections as per industry practices. Nos. 15
26 Removal of networking racks including removal of old unused UTP Cables, OFC cables, I/O boxes, caping casing, conduit pipes and other accessories including active & passive components at site after complete tracing of live and non-live networking cables. Nos. 6
27 Cable Route markers: Supply and installation of surface markers (stone) to indicate route of the cables shall be planted to mark cable routes and indentify underground fiber optic cables. Display marker should have visible engraved message like "OFC CABLE LAID BELOW" and cable depth. Nos. 20
28 Documentation: Two sets of detail documentation required to be done for showing network architecture with all tagging details, block diagram of network. The documents must be helpful during fault findings and rectificaton. Job 1
29 Warranty: Min. 01 Year for the complete system from the date of final acceptance by HAL-ADL after successful installation, commissioning and demonstration of the system. In case offered OEM warranty is for more than a year without any extra charges then warranty for that item(s) from OEM will be applicable. Nos. 1
B Scope of Works
1 Complete Installation, Commissioning & Integration shall be the responsibility of vendor. If required, vendor can visit the site with prior intimation/permission of HAL-ADL within working hours. Any such request by vendor should be submitted to HAL-ADL prior to 06 working days before tender due date.
2 Vendor shall take all necessary care for protection of installed system against rodent and water proofing. For under ground cable laying detection system should be used for avoiding damage to existing underground utilities. In case of any damage / failure during installation or within warranty period vendor has to repair to it original condition at no extra cost.
3 Marking and tagging of the installed network should be as per industry standards. Cabling should be done with proper numbering and ferruling.
4 Installation and commissioning of all active and passive network components required for completion of work.
5 Vendor shall carefully study the full requirement including installation, commissioning, configuration etc. (on turn-key basis). Any tools, equipments, accessories required for such purpose including any extra material shall be provided by vendor at no extra cost.
C Other Terms & Conditions
1 Authorization: Vendor must submit valid authorization certificate of OEM for passive network components as offered against this tender.
2 Installation, commissioning and prove-out to be done at HAL Site. It is recommended to depute minimum one person for a period of installation at HAL-ADL premises.
3 Materials for which makes are not specified must be of BIS / ISI marked of reputed make where ever applicable.
4 Bidder has to completely fill compliance matrix in 1:1 format as per compliance sheet with Make, model and part numbers of all products offered and submit along with technical document support.
5 All the length of cables and digging /laying lengths are estimated, payment will be done as per actuals measurements.
6 Under the fiber network vendor has to splice all cores at all the network racks or as per direction of engineer-in-charge.
7 Apart from above items, vendor has to supply and install any additional components / accessories if required as per site requirement for installation without any additional cost to HAL.
8 Desired phase wise milestone activities with estimated time period are to be given for completion of the complete requirement. It is required to complete the work in a span of 120 days.
9 Documentation: Two sets of detail documentation required to be done for showing network architecture with all tagging details, block diagram of network. The documents must be helpful during fault findings and rectificaton. Vendor has to submit all required documents like measurement book, depth HDD profile report, cable/Fibre termination and /continuity test report etc,. after successful completion of the work.
Name of Vendor:
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
NIT.pdf
TENDER_DOCUMENT • 0.50 MB
General_Condition_of_Contract.pdf
TENDER_DOCUMENT • 1.21 MB
BB_E_CRITERION.xlsm
TENDER_DOCUMENT • 0.01 MB
AAAA.xlsm
TENDER_DOCUMENT • 0.01 MB
DDDD.xlsm
TENDER_DOCUMENT • 0.01 MB
CCCC.xlsm
TENDER_DOCUMENT • 0.02 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .