Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.5 LAccepted-AOC | L1 | Accepted-AOC Lowest bid | |
| 2 | L2₹47.4 L+₹6.9 L (16.9%)Rejected-Finance 25 25 SADAR BAZAR JALANDHAR CANTT | JALANDHAR | JALANDHAR | PUNJAB | L2 | Rejected-Finance Other than lowest bid | |
| 3 | L3₹48.0 L+₹7.4 L (18.3%)Rejected-Finance 205 PARSHAV VIHAR PLOT NO 50 1 P EXTN PATPARGANJ DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L3 | Rejected-Finance Other than lowest bid | |
| 4 | L4₹48.4 L+₹7.8 L (19.3%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L4 | Rejected-Finance Other than lowest bid | |
| 5 | L5₹49.4 L+₹8.9 L (21.8%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bid |
Tender Value
Refer Docs
EMD Value
₹1.3 L
Closing Date
19 Oct 2020, 6:00 pmClosed
CWE Jalandhar Cantt
HQ CWE kabir Road Jalandhar Cantt Pin-144005
Please refer tender documents
2020_MES_375813_1
CA NO CWE/JAL/W-55/2020-21 8320/55/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jalandhar Cantt
Class C Category a(i)or b(i) for contractors enlisted with MES
8 documents required · 8 mandatory
₹1,000
Garrison Engineer West JRC
₹1.3 L
Yes
9 Nov 2020
8 Sept 2020
21 Oct 2020
8 Sept 2020
19 Oct 2020
6 Oct 2020
Amount
Taking down carefully by disconnecting and unscrewing from boards/outlet boxes, electric meters of any locations & size and deposited to MES store yard, maintain proper records, reading of old meters, make, SI No, date & time of removal and submitted to AGE E/M office, complete all as specified and directed
Supply and fixing single phase 2 wire system direct connected prepaid key pad based BIS Marked IS-15884 Digital Energy Meter, 10-60 Amps, 240 Volts, accuracy class-1.0 with, bluetooth based alongwith parallel Consumer Interface Unit (CIU) and Soft Token Transfer Device (STTD) at houses or any equivalent charging system to charge the meter with software/firmware in the meter to be updatable w.r.t. energy requirement in future and advancement of technology polycarbonate meter box with facility of meter reading having LCD type display, calliberation LED, numeric key pad for token entry with RS 232 communication port, Tri colored LED for credit status indication, push button for scroll and having features for load disconnection, in case the credit limit become zero or increase of load than permissible limit, reconnection and disconnection of load, buzzer to give alarm in case of low credit and overloading and data download port for last 25 days (min) temper event and load survey for last 45 days. Meter must be having facility to caliberate happy hour & holiday definition. Meter must be having facility of generating authenticated billing code (ABC) at the beginning of every month to facilitate energy consumption bill generation of every consumer through mobile app alongwith other options. Meter must be with all standard anti temper features including sealing to meter with sealing punch facility, meter shall be comprised/programmable with security data as per protocol of software/firmware in the meter to be updatable w.r.t. energy requirement in future and advancement of technology.
All as per item No 2 here-in-before but 3 phase four wire 415 volt 50 Hz supply including necessary connection complete all as specified and as directed by Engr-in-Charge. Note for Ser Item No 2 & 3 : - (i) Electric meter to be fixed under supervision of authorised person from company. (ii) The contractor shall submit guarantee of 7 years from the manufacturer. Any fault occurs during this period, the contractor shall replace the meter w/o any cost. No claim whatsoever shall be entertained on this account at any later stage.
Installation, commissioning and implementation of vending system through server in existing computer system, mapping of consumers complete all as specified and as directed by Engr-in-Charge. Note : - (i) The vendor shall provide their own mobile app (duly complying all cyber security measures) for vending tokens by the consumer for payment/recharge etc using smart phones through Debit/Credit cards/Netbanking etc. (ii) Cost of vending charges for meters commissioned during progress of work shall deemed to be included in the rates.
Supply portable palm top based common meter reading instrument with software for meter data analysis etc complete all as specified.
S&F 2 pair multi coloured, 0.5 mm thick multi stranded cable for connection from meter to consumer interface unit (Tele cable RJ-11) drawn in PVC conduit not less than 20 mm dia fixed on wall with suitable clamps etc complete all as specified
Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction / terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. all as specified.
Supply and fix 2 Single core cable PVC insulated unsheathed, with stranded copper conductor of size 6 Sqmm & one run of 6 sqmm for earth connection concealed in and including recessed PVC conduit suitable size but not less than 25 mm dia complete all as specified. Note : Two run of 6 sqmm & one run of 6 Sqmm alongwith PVC conduit shall be measured as one unit.
M&L for four single core (submain) FRLS PVC insulated cable with 10 sqmm nominal cross sectional area stranded copper conductor and two single core green PVC insulated 10 sqmm stranded copper conductor earth continuity cable drawn through in and including recessed PVC conduit suitable size but not less than 25 mm dia complete all as specified. Note: Four run of 10 sqmm and two run of 10 sqmm alongwith PVC conduit shall be measured as one unit.
Supply and fix MCB DB 4 way TPN, with bus bar 200 amps rated ,neutral link and earth bar ,double door,smart board type duly powder coated comprising with the following :- (a) MCB B Curve 4 pole 63 A capacity - 01 No. (b) MCB, B Curve SPN 40 A - 02 Nos (c ) MCB, B Curve SP 6-32 A, 240 Volts, - 8 Nos,
Supply and fix MCB DB 8 way SPN, with bus bar 200 amps rated ,neutral link and earth bar ,double door,smart board type duly powder coated comprising with the following :- (a) MCB B curve SPN 40 Amps 240 volts - 01 No (b) MCB B curve SP 6-32 Amps 240 volts- 6 Nos
M&L for single core FRLS PVC insulated cable with 10 sqmm nominal cross sectional area stranded copper conductor for connection from existing service cable to electric energy meter including copper sleaves/ferruls for jointing all as directed by Engineer-in-charge.
M&L for fabrication of Bus bar chamber wall mounted, indoor type with 2 mm thick CRCA sheet, front opening with locking and sealing arrangement,smart board type duly powder coated size 500x300x200 mm comprising of Copper bus bar 200 Amps - 04 Nos fixing of insulator incl neccessary connection of existing cables with copper lugs and out going cables to meter boxes incl all fixing accessories all as diected by the Engr-in-charge.
M&L for fabrication electric meter box, wall mounted, indoor type with 2 mm thick CRCA sheet front opening door by providing 04 Nos of glass window on front door for looking reading of the electric meter, with locking and sealing arrangement,smart board type duly powder coated of suitable size for 04 Nos of pre-paid electric meters with all fixing accessoris boxes all as diected by the Engr-in-charge.
CHOUDHARY AND SONS
SANJEEV ENTERPRISES
commercial traders
BANSAL ENGINEERING
JAZZCON ENGINEERS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .