| 1 | L1₹7.5 CrAccepted-AOC B 12 VISHAKARMA JYOTI SUBHASH LANE MALAD E MUMBAI 400097 | MUMBAI SUBURBAN | MAHARASHTRA | 400097 | ₹7.5 Cr | L1 | Accepted-AOC Being the lowest tenderer (L1) and reasonabale |
| 2 | L2₹7.9 Cr+₹41.1 L (5.49%)Rejected-Finance | ₹7.9 Cr+₹41.1 L (5.49%) | L2 | Rejected-Finance Not being the lowest |
| 3 | L3₹9.3 Cr+₹1.8 Cr (24.0%)Rejected-Finance NOT SPECIFIED | ₹9.3 Cr+₹1.8 Cr (24.0%) | L3 | Rejected-Finance Not being the lowest |
Tender Value
₹6.3 Cr
EMD Value
₹6.4 L
Closing Date
1 Nov 2021, 6:00 pmClosed
Chief Engineer
HQ Chief Engineer (Navy) Mumbai, 26 Assaye Buildings, Colaba, Mumbai-400005
PROVISION OF DEFICIENT MI ROOM AND OTHER OTM ACCOMMODATIONS AT MO(MB), GHATKOPAR
2021_MES_475826_1
87896/E8
Open Tender
Civil Works
Lump-sum
540 days
GE(P) Bhandup
As per tender Documents
8 documents required · 8 mandatory
₹3,000
GE(P) Bhandup Mumbai
₹6.4 L
Yes
16 Nov 2021
17 Sept 2021
4 Nov 2021
17 Sept 2021
1 Nov 2021
18 Oct 2021
Amount
SCHEDULE "A" Part - I (BUILDINGS & STRUCTURES WORKS) Total of Sch-'A' Part-I B/F
SCHEDULE "A" PART-II (SITE CLEARANCE, AREA DEVELOPMENT, EXCAVATION & EARTHWORK) Total of Sch-'A' Part-II B/F
SCHEDULE "A" PART-III (DEMOLITION/ DISMANTLING) Total of Sch-'A' Part-III B/F
SCHEDULE "A" PART-IV (INTERNAL WATER SUPPLY) Total of Sch-'A' Part-IV B/F
SCHEDULE "A" PART-V (INTERNAL ELECTRICFICATION) Total of Sch-'A' Part-V B/F
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Total of Sch-'A' Part-VI B/F
SCHEDULE "A" PART-VII (AREA DRAINAGE) Total of Sch-'A' Part-VII B/F
SCHEDULE "A" PART-VIII (WEIGH BRIDGE PLATFORM) Total of Sch-'A' Part-VIII B/F
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIFICATION) Total of Sch-'A' Part-IX B/F
SCHEDULE "A" PART-X (EXTERNAL WATER SUPPLY) Total of Sch-'A' Part-X B/F
SCHEDULE "A" PART-XI (FIREFIGHTING) Total of Sch-'A' Part-XI B/F
SCHEDULE "A" PART-XII ( LIFTS ) Total of Sch-'A' Part-XII B/F
SCHEDULE "A" PART-XIII ( LIGHTNING PROTECTION ) Total of Sch-'A' Part-XIII B/F
SCHEDULE "A" PART-XIV (SUMMER APPLIANCES) Total of Sch-'A' Part-XIV B/F
SCHEDULE "A" PART -XVI (MISCELLANEOUS ITEMS)
SITE CLEARANCE & EARTHWORK
Removing excavated material (any type) and depositing it outside Ministry of Defence Land. Note for 16.001 (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site. (iii) All excavation earthwork covered under Sch'A' part III to part XIV shall be measured and paid under this item.
Removing debris obtained from demolition of buildings and depositing it outside Ministry of Defence Land. Note for 16.002 (i) Before quoting the tender, the bidders are advised to ascertain the distance outside MD and, at which the excavated material/ debris are to be disposed off. No extra claim what-so-ever shall be entertained on this account. (ii) This item shall be considered as per the requirement at site.
DEMOLITION / DISMANTLING
Dismantling the old weigh bridge of 20T capacity carefully and shifting to a new location within campus of MO Ghatkopar and reinstalling the same on the newly constructed weigh bridge platform all as directed by Engineer in Charge. NOTES: a) Any damage to the dismantled weigh bridge occurred during dismantling or shifting is to be made good by contractor at no extra cost to Govt. b) Cost for equipment's/tools required for dismantling and reinstalling the weigh bridge shall be deemed to be included in the rate. c) Bidder should visit the site of work before quoting, accept the weigh bridge "as is where is" and shall ascertain requirement, replacement of spare parts, etc. for refixing nad made functional and quote his unit rate accordingly d) The cost of rectification of defects in the completed item of work, if any, shall also be deemed to be included in the quoted rate of this item e) No Claim whatsoever due to improper understanding of the scope of work shall be admissible.
Taking down all type of old unserviceable MCB/TPN DBs etc complete all as specified and directed.
Taking down all type of old unserviceable MCBs (SP/SPN/TPN/TP) etc complete all as specified and directed.
Taking down U/S Sub main wiring of copper/ Aluminium twin core cable of various sizes complete.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc
Taking down carefully by unscrewing from boards/outlet boxes, fittings and fixtures such as switches,sockets, ceiling roses, lamp holders, brackets, ceiling fittings,bulk head fittings, tube light fittings and regulators, etc.
INTERNAL WATER SUPPLY
S & F Hand shower (Health faucet) with 1 meter long easy flex tube in chrome finish and wall hook with NRV (Back flow preventer) Make - Jaquar Model No ALD-579 or equivalent complete all as specified and directed by Engineer-in-Charge
Supplying & Fixing Pressure relief valve complete all as specified and directed.
a) 25 mm Dia
b) 32mm dia
c) 40mm Dia
INTERNAL ELECTRIC SUPPLY
S & F modular type bell ding dong of 2 module size, conforming to IS: 8884- 1978 complete all as specified and directed. Make: Legrand Arteor Cat-Part No. 5734 43 or equivalent model of MK Cat-Part No. W26235, or Havells Cat-Part No. AHOLXXW000
S & F energy efficient 5 star rated fan having blade sweep 1200 mm, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the ceiling fan complete all as specified and directed. Make: Crompton Cat-Part No. ENTRUST 50- 5 STAR or equivalent model of Havells Cat-Part No. ES - 50 Premium or BAJAJ Cat-Part No. Electra 50
S & F 10 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 110 lumen/W, with THD < 20%, IP20 Rated, CRI >80 polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 140V - 270V AC, input frequency 50- 60 Hz, PF > 0.9, with operating temperature Upto 45 deg C,SDCM < 5, Class C – Non Replaceable Driver including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. The said product should have BIS Mandatory before tender publish date. Make: Philips Cat-Part No. BN 021 LED10S- 6500 PSU GR S1 or equivalent model of Bajaj or Wipro
S & F 22 W surface/wall mounted LED batten having high efficiency long life LED chips with Lumens Output 2500 Lumens and luminous efficacy of > 110 lumen/W, THD < 20%, IP20 Rated, CRI >80 polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 140V - 270V AC, input frequency 50- 60 Hz, PF > 0.9, with operating temperature Upto 45 deg C,SDCM < 5, Class C – Non Replaceable Driver including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. The said product should have BIS Mandatory before tender publish date. Make: Philips BN 021 LED25S 6500 PSU GR S1 or equivalent model of Bajaj or Wipro
S & F 25 W LED street light having high efficiency long life LED module with Lumes out put of 5500 Lumens with high LED efficacy of ≥ 110 lumen/W, integral current electronic LED driver with surge voltage protection of 4KV, IP 66 protection & IK07 Vandal Proof Protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness,Voltage range 140 - 270V/ 50Hz, with Life of 30,000 hrs @Ta 35°C, with Class I Insulation classification, Under certification of IS10322, including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and 1.5 m long bracket, having 40 mm diameter light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. The said product should have BIS Mandatory before tender publish date. Make: BAJAJ Cat-Part No. BAJAJ 169799 BRTFG 45W LED I or equivalent model of Havells, Philips or Wipro
S & F energy efficient non-metallic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10" or equivalent model of Havells Cat-Part No. Ventil Air - DX White or BAJAJ Cat-Part No. Maxima DX
Supply and fix LED light fitting recess type to be fixed in false ceiling with wiring connections of capacity 36 watt AC 230 volts 50 HZ of Make Bajaj cat No BPSF36W WH LED or equivalent in Havells/Crompton
S & F ISI marked MCB for AC applications till 63 A, having breaking capacity Icn = 10 kA, conforming to IS/IEC 60898-1-2002, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, all complete as specified and directed.
(a) 6- 32 A, SP MCB, C- curve
(b) MCB SPN 32 A C curve, 240 V 50 Hz AC
(c) MCB TPN 63 A C curve, 240 V 50 Hz AC
Supply, installation, test and commissioning of Bldg Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. complete as specified and directed by the engineer-in-charge. INCOMER MCCB 200 Amp 4 pole 415 v 36 KA -01 No.Incomer with Thermal magnetic release OUTGOING MCCB 63 Amp 4 pole 415 v 36 KA-02 (5 Nos for Five floors ) MCCB 63 Amp 4 pole 415 v 36 KA-02 (Spare) BUSBAR 300 Amp rated copper bus bar with colour coded heat shrinkable sleeve METERING & INDICATION i) Ammeter,Digital type, with suitable CTs - 01 set ii) Voltmeter, Digital type - 01 set iii) R-Y-B phase indicating lamp- 03 Nos iv) MF meter with suitable CT's-01 No.
Supply and fix MCB protected socket with 25 Amps socket and MCB 25 Amp , 'C' series 10 KA, with suitable 4 module sheet metal enclosure cover plate etc complete as per IS-13032 and IS-8623 make Havells or equivalent
EXTERNAL ELECTRIFICATION
M & L for Disconnecting the existing HT/LT connections related accessories and taking out indoor type transformer of capacity 315 KVA and depositing to store yard as directed by E-in Charge
Installation of 500 KVA transformer by bringing it from store of Modern store house wk and making HT/LT connections with existing VCB, transformer and panel in sub station all as specified and directed by Engineer in charge. NOTES: a) Any damage to the transformer occurred during shifting is to be made good by contractor at no extra cost to Govt. b) Cost for equipment's/tools required for reinstalling the transformer shall be deemed to be included in the rate. c) Bidder should visit the site of work before quoting, accept the transformer "as is where is" and shall ascertain requirement, replacement of spare parts, etc. for refixing and made finctional and quote his unit rate accordingly d) The cost of rectification of defects in the completed item of work, if any, shall also be deemed to be included in the quoted rate of this item e) No Claim whatsoever due to improper understanding of the scope of work shall be admissible.
Supply, installing, testing and commissioning of Utility Panel of suitable size, factory made, CPRI approved indoor type and as per IS- 8623, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. complete as specified and directed by the engineer-in-charge. a) MCCB 250 Amp 4 pole 415 v 36 KA-01 No (as incomer) b) MCCB 160 Amp 4 pole 415 v 36 KA-01 No (FF panel) c) MCCB , 04 pole 63Amp 36 KA -01 No (lift panel) d) MCB , TPN 16 Amp 10 KA -02 Nos (Common lights, ans stair case ) e) MCB SPN 20 amps 10 KA 240 V-01 No. for street lights f) Busbar, copper, 400 Amps for phases and neutral duly colour coded sleeves mounted on hygroscopic pvc insulator-01 set g) Multi function meter to measure power, A, V, F etc - 01 No. h) RYB indicator LED type-01 set i) Ammeter 0-100 amps -01 No.woth suitable CTs
Supply, installating, testing and commissioning of Bldg Panel of suitable size, factory made, CPRI approved indoor type and as per IS- 8623, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of size 50 mm x 50 mm x 6 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. complete as specified and directed by the engineer-in-charge. (a) MCCB 315 Amp 4 pole 415 v 36 KA (as incomer) (b) MCCB 100 Amps 4 pole 415 v 36 KA - 05 Nos (outgoing for ground, first, second and third floor+1 spare) (c) MCCB 63 Amps 4 pole 415 v 25 KA (outgoing for fourth floor) - 01 Nos d) Busbar, copper, 400 Amps for phases and neutral duly colour coded sleeves mounted on hygroscopic pvc insulator-01 set e) Multi function meter to measure power, A, V, F etc - 01 No. (f) RYB indicator LED type-01 set
Supply, installing, testing and commisssioning of factory made, CPRI approved Indoor type Lift panel and as per IS-8623 made out of 2mm thick CRCA sheet, duly powder coated, compartmental design with locking arrangements, weather and vermin proof with proper ventilation slots, IP 52 free standing floor mounted with copper busbar of suitable size for phase and neutral mounted on hygroscopic insulators comprising of the following:-(Lift panel) (a) MCCB 63 Amp 4 pole 415 v 50 KA (as incomer) (b) MCCB 32 Amps 4 pole 415 v 25 KA (outgoing for Lift 1, Lift 2 & one spare) c) Busbar, Alumium 200 Amps for phases and neutral duly colour coded sleeves mounted on hygroscopic pvc insulator-01 set d) Multi function meter to measure power, A, V, F etc - 01 No. e) RCBO 300 Milliamp 415V, 50 Hz -02 Nos ( For lifts)
M&L for 6 mtr long hot dipped galvanised octagonal poles with top A/F 70 mm bottom A/F 130 mm made out of 3mm thick HT sheet along with base plate of size 225x12 mm including 1500 mm long single arm bracket made out of 48 mm dia GI pipe and M24 x750 m long 'J' type EN8 grade foundation bolts along with template including RCC foundation as per Manufacturers recommendations complete with form work etc and consisting of the following: (a) MCB SP 6A 230 V,10 kA mounted on 3 mm thick Hylam Sheet -1 No. (b) 4 Way connector bolt along with locking arrangement ,weather proof and water proof control space. Note: (a) The Rate quoted deemed to include the cost of 50 mm PVC pipe from cable trench to center of the pole concrete and 'J' type EN8 grade foundation bolts. (b) The rate quoted deemed to include the cost of connecting of incoming and outgoing cable in new octagonal poles through PVC pipe including taking out loop extending upto junction box connecting complete all as specified and directed. (c) Makes: Bajaj/Jindal/Crompton/Philips
M & L for 3 Core 1.5 Sq mm size multistranded copper conductor PVC unsheathed 650 / 1100 Volt Grade drawn in through steel tubular poles, for interconnection of cable looping box to Street Light Fitting complete all as specified and directed.
Material and labour for earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 32x 6 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 40 mm bore (Medium grade) all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar, including funnel, wire mesh and 20 mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all as specified and directed. (Ext Elec: 20, Int. Elec 02, DG Set 06, Lightening Protection: 04)
Supply, installing, testing and commissioning of LT Panel suitable size, factory made, CPRI approved, as per IS-8623, Indoor type compartmentalised double door both side openable with hinged doors and locking arrangement made out of 2.00 mm thick CRCA sheet supported on structural steel frame with angle iron of size 50X50X6 mm incl earthing studs labelling painting all internal and external surfaces with Powder coating(minimum 7 tank process) duly fixed in ground with PCC foundation (1:2:4) type B1, with danger Notice Plate, suitable for 3 ph, 4 wire, 500 V, AC 50 Hz supply incl necessary control wiring and PVC cables for internal connections complete all as specified and directed by E-in-charge. (a) Bus bar copper 1200 amp-04 Nos with suitable size epoxy insulators -01 set (b) ACB 800 Amps, 4 Pole, 50 KA, 415 V, 50 Hz, EDO Microprocessor based 18 G-01 No (Incomer) (c) MCCB 160-400 Amps, 50 KA Microprocessor based, 415 V, 50 HZ, 4 Pole-02 Nos(O/G for MI Room+ Extg Load) (d) MCCB 40-100 Amps, 36 KA Microprocessor based, 415 V, 50 HZ, 4 Pole-01 Nos(O/G Spare) (e) Digital Ammeter 0-800 Amps with suitable CT's-01 Nos (f) Digital Ammeter 0-500 Amps with suitable CT's-02 Nos (g) Digital Ammeter 0-100 Amps with suitable CT's-01 Nos (h)RYB indicator LED type -04 set (j) MF function meter -01 No (k) Digital Voltmeter 0-500 Volts-01 Nos
Supply only insulating mats as per IS-15652 Class A, 2 mm thick
Supply only insulating mats as per IS-15652 Class B, 2.5 mm thick
EXTERNAL WATER SUPPLY
Cutting existing GI pipe 50 mm dia for branch connection of 50 mm dia GI pipe incl cutting extg GI 50 mm dia pipe and insertion of tee 50X50x50 mm dia and connecting complete incl cutting extg pipe threading and inserting TEE and Nipple and Union of 50 MM dia incl all required excavation and earth work complete all as specified and directed
Supply install test and commissioning of Pump set three phase,Head 30 mtrs and discharge 1.5 LPS with bronze impellar approx. 2.0 HP capacity make Kirloskar Model KDI -235 + or equivalent complete with suitable foundation , suction and delivery pipe upto common header, with Suitable Foot valve make Normex with synthetic ball, GI Pipes medium grade for suction and delivery, and NRV and gate of suitable size on delivery side complete all as specified and directed by Engineer In charge
Supply, installation, test and commissioning of Pump Panel of suitable size, factory made, CPRI type tested, indoor, cubical compartmental type, double door, both side openable with hinged doors & locking arrangement, made out of 2.0 mm thick mild steel CRCA sheet, wall mounted supported and fixed on structural frame of angle iron of size 40 mm x 40 mm x 5 mm, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length size, including fixing lugs bolts, screws etc. complete as specified and directed by the engineer-in-charge. a) MCB TPN 20 Amp 415 V 10 KA-01 No (as incomer) b) MCB TPN 10 Amp 2 pole 415 V 10 KA-02 No (Pump set) c) DOL starter suitable for 02 HP pump set -02 nos d) ON /OFF LED indicator set for pump set - 02 nos e) ON /OFF LED indicator set for mains - 01 nos f) Busbar, copper, 200 Amps for3 phases and neutral duly colour coded sleeves mounted on hygroscopic pvc insulator-01 set g) Multi function meter to measure power, A, V, F etc - 01 No. h) Ammeter 0-25 amps -01 No.with suitable CTs
Material and labour for construction of valve chambers of size 750x750x750 mm depth including excavation and earthwork. PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick PCC block masonry walls built in CM 1:4, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Material and labour for earthing complete with galvanised steel plate electrodes of size 600x600x6mm thick buried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised 4 mm earth lead by means of nuts bolts check nuts GI washers earth wire protected by galvanised iron pipe 15 mm bore (Medium grade) all as directed including concrete pit in PCC (1:3:6) type CI, precast RCC cover slab of size 30x30x10 cm with one handle for lifting made out of 8 mm diameter MS bar, including funnel, wire mesh and 20 mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all as specified and directed.
FIREFIGHTING
Supply and fix Bulb type gun metal sprinkler head,of following types, set to operate at 57 degree C - Extended coverage sidewall Sprinkler
Supply and fix Automatic air release valve 50mm dia suitable for water tank with 50mm gun metal stop valve complete
S & F Fire extinguisher Water type 03 Lit capacity IS: 15683 complete all as specified and directed by the engineer-in-charge.
S & F fire extinguisher ISI Marked CO2 03 Kg capacity IS:15683 complete all as specified and directed by the engineer-in-charge.
Supply and fixing of drain valve , test valve , sight glass and union complete on sprinkler pipe near flow switch complete of required size incl pipe line upto drain pipe
S & F, 2 Core x 1.5 mm2, Multistranded Copper, PVC insulated, FRLS Type ST-2 PVC outer sheath, Armoured cable, RED in Colour. The cable shall be complete with Lugs, double compression glands, cable tags and Ferruling.
Supply, installation, testing and commissioning of factory made, CPRI type tested, indoor, cubical compartmental type "Motor Control Center" (MCC) of suitable size, conforming to IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 54 protection made out of 2.00 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3- Phase 4 Wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size, including fixing lugs, bolts, screws etc. complete as specified and directed by the engineer-in-charge. The MCC shall comprise of the following: [A] BUSBAR CHAMBER [i] 01 Set (3L + N) of copper busbar of rated capacity 250 A, covered with PVC insulated sleeves including insulator, nuts, bolts, etc. with complete connection [B] INCOMING [i] MCCB 125-160 A, 415 V, 36 kA, 4 pole, 50 Hz with thermal magnetic release-01 No [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs. On hrs & interrupts- 01 Nos. [iii] LED phase indicators (Red, Yellow, Blue)- 01 Set
S & F of orifice plate made out of 6 mm thick SS 304 with orifice of required size to be fitted between flange and landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as specified and directed by the engineer-in-charge. Make: Newage, AAAG, Minimax
M & L for Construction of fly-ash brick masonary valve chamber of size 1000 mm X 800 mm X 1000 mm (internal dimensions) with PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 150 mm thick & 150 mm wide offsets around over 100 mm thick hardcore , 200 mm thick PCC block masonry walls built in CM 1:4, 100 mm thick PCC 1:2:4 Type B1 coping finished even and smooth, rendering 10 mm thick in cement mortar (1:6) finished even and smooth, with out using extra cement internally including top of floor including excavation earth work in hard/Dense soil 6 mm thick MS sheet cover fixed on 25 mm X 25 mm X 6 mm thick angle iron frame with hold fasts embedded in PCC coping with locking arrangement, mild steel handle and painting to steel surfaces with two coats of synthetic enamel paint over one coat of primer including disposal of surplus soil to a distance not exceeding 50 m etc complete all as specified and directed.
Supply and fix amplifier 50 watts capacity with micro phone set complete
S & F of the following type of signage's made out of 3 mm thick opaque PVC foam board with computer cut, PVC non-reflective self adhesive vinyl painted foam board, complete with mirror fasteners as specified and directed by the engineer-in-charge.
a) Sign of size 250 mm X 300 mm reading 'IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE' in 12.5 mm block letters in red and white background, properly spaced to provide good legibility located directly above the call-button and squarely attached to the wall or partition in a way that the top of the sign is not above 2 m from the finished floor level
b) Sign of size 150 mm X 600 mm, posted and maintained within each stair enclosure on every floor, indicating the number of the floor in bold type and at 75 mm high numerals in red and white background, securely attached to the stair side of the door in a way that the bottom of the sign is not above 1.5 m from the finished floor level
c) Sign of size 150 mm X 600 mm, posted and maintained at each lift landing and on the side of the stairway door from which egress is to be made on every floor, indicating the lift / lift bank / stairway by an alphabetical letter in bold type and at 75 mm high letters in red and white background, securely attached to the side of the stairway door from which egress is to be made in a way that the bottom of the sign is not above 1.5 m from the finished floor level
LIFTS
Design supply, installation, testing & commissioning of 15 Passenger cum stretcher lift, having 1.5 m/s car speed, single speed motor suitable for 3- Ph, 415 V, 50 Hz electric power supply, conforming to IS-14665, suitable to serve G+04 upper floors with AC Variable Voltage & Variable Frequency drive (VVVF drive), complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infrared sensor in full height of door & built in announcing system without hand set (03 Nos, one each in car, machine room & near ground floor landing door) complete all as specified and directed. Make: Otis, Schindler, Mitsubishi, Thyssenkrupp, Toshiba Johnson The lift shall conform to the following technical specification. [i] Type of Lift: Passenger cum stretcher lift [ii] Load Capacity:15 passenger (1020kg) [iii] Speed: 1.5 m/s with single speed motor [iv] Power Supply: 3- Phase, 4 Wire, 415 V, 50 Hz AC [v] Type of Drive: AC Variable Voltage & Variable Frequency [vi] Type of Machine: Gearless [vii] Car Size: Not less than 1.1 m X 2.4 m, i.e. 2.64 m2 [viii] Car & Landing Door at all floors: COPD with VVVF door drive, opening size not less than 900 mm X 2100 mm, sliding type, fabricated by stainless steel not less than 16 gauge having hairline finish (N-304)
[ix] Car Enclosure: Manufactured with stainless steel frame not less than 16 gauge with hairline finish (N-304) having stainless steel false ceiling with hairline finish, internal lighting arrangement with LED light fittings operated on commercial supply and one LED light fitting operated on battery with invertor as emergency light, complete internal ventilation system provided with concealed axial / cross flow fan with auto cut-off system and stainless steel grill / wire-mesh for protection [x] Provision of standard thickness 40 mm diameter stainless steel hand-rail all around inside the car cabin incl standard size mirror [xi] Terminal Buffers: Metal special spring / PU / Oil buffers as per manufacturer's recommendation. The buffing stroke shall not be less than 200 mm. [xii] Door Opening (inside): Protected by COPD stainless steel door having hairline finish with opening not less than 900 mm X 2100 mm [xiii] Car & Counter Weight Guide: As per OEM recommendations [ixv] Flooring: As per OEM recommendations [xv] Signals: (a) Combined luminous hall buttons with LED / LCD / TFT hall position indicators at all floors (b) LED / LCD / TFT car position indicator panel of stainless steel (c) Car operating panel of stainless steel with luminous buttons in car (d) Car direction indicator in car & landing (e) Battery operated alarm bell & emergency light (rechargeable) along with suitable maintenance free battery. (The system shall be separate from ARD batteries.) (f) Overload warning feature in car cabin (display / announcing type both) (g) One fireman's switch to be installed at ground floor near landing door.
(h) All signal fixtures & car operating panel on hairline stainless steel face plate with hairline finish (i) Infrared door sensor safety edge of door for entire height (j) Built in announcing system without handset 2 Nos., one for lift car & ground floor landing door and one announcing system with handset in machine room (k) The interior of the car shall be provided with a device that audibly announce the floor position of lift car has reached and announce that car entrance / exit door is open or closed [xvi] Stops & Opening: 5-5 with all openings being on the same side [xvii] Safety Device: (a) Automatic Rescue Device (ARD) / automatic landing device operating with maintenance-free batteries having suitable capacity. The batteries must have auto charging facilities. The charger input be connected with converter of regenerative drive. (b) The ARD actuation time shall be less than one second after failure of power supply and when ARD is operative the car shall stop at the nearest floor and then doors shall open. [xviii] Machine Room: Located above the hoist way, details as per building drawings [ixx] Hoist way: Construction details as per building drawings [xx] Civil Work: Necessary civil work viz. making good disturbed surfaces, modification to landing space to suit car size, necessary foundation to machine(s), etc. [xxi] One number of wall mounted type telephone instrument installed inside of car cabin along with fixing arrangement and telephone cable of suitable size from car cabin to machine room run along with travelling cable. The telephone instrument shall be connected in the telephone DB installed in the machine room.
M&L for Earthing complete with copper plate 60×60cm ×3.15mm thick electrode, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level, connected to 20×3.15 mm copper strip as earthing lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including 20 mm bore medium grade GI Pipe with , MS funnel with wire mesh,.watering arrangement and 50 mm bore light grade GI pipe for earth lead protection from earth plate to test point or panel connecting point , PCC chamber ,CI cover with frame etc including necessary excavation in any type of strata, returning, filling , removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part - I, connected to Earthing test point all as specified and directed and testing on completion.
SUMMER APPLIANCES
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2 of capacity 2 TR inverter type
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx. storage capacity of 80 litres and nominal cooling capacity 40 ltrs per hour including stand complete all as specified and directed by by Engineer-in-charge. Make: Blue star, Voltas, Usha
DG SET
Supply installation, testing & commissioning of factory assembled stand by duty Diesel Engine driven generating set coupled with alternator AC to give continuous output of 160 KVA at a power factor of 0.8 lagging, 415 volts, AC, 3 phase, 4 wire, 50 HZ, 1500 RPM, diesel engine liquid cooled, mounted on common base frame complete with in built fuel tank of adequate capacity with fuel line & accessories, PCC foundation work as per manufacturer's instructions, vibration damper pads, micro processor based relay panel for automatic starting on mains failure, control panel showing all parameters of engine & alternator, sound proof canopy & other accessories etc. and confirming to the under mentioned technical specifications as per specified & directed. Make: Kirloskar, Crompton Greaves, Cummins, Mahindra (A) DIESEL ENGINE : Water cooled, turbo charged,4 stroke,1500 RPM under NTP conditions conforming to IS -4722, BS-5000, IEC-60034/1, ISO 8528, BS-5514, ISO-3046 with an overload capacity of 10% for one hour in total 12 Hrs of continuous operation complete with the following accessories. (a) Radiator with blower fan with guard (b) Pipe coupling for cooling system (c) Corrosion inhibitor coolant (d) Filters for fuel/lube oil (e) Fly wheel housing and fly wheel suitable for alternator (f) Engine bearing mechanism in fly wheel housing (g) Shut off coil protection with safety for LLOP /HWT/ Over speed/high and low DC voltage. (h) Dry type heavy duty replaceable paper element air cleaner with restriction indicator and vacuum indicators . (J) Residential silencers. (k) Stainless steel exhaust flexible bellows.
(l) Motor driven priming pump. (m) Electric starter motor (n) Battery charging alternator. (o) Exhaust piping made out of STIC "C" class MS Pipe inclusive of all accessories and hardware, necessary support as per manufacturer’s recommendations to sustain back pressure with rain cap. (p) Mineral wool insulation 2 inch thick suitable for 400 degree celcius temperature cladded with aluminium sheets for the entire length of exhaust pipe as per manufacturer's recommendations. (q) First fill of oil, coolant and diesel during commissioning. (r) Interconnecting copper cabling of adequate capacity between batteries and controller. (s) Fuel pipe. C class STIC 1"/1.5"/2" dia - 01 lot (t) Self starter 12/24 volts DC, Electric operated, with suitable class electronic governor " (u) Metering equipment's for recording (i) Battery voltage and charging rate (ii) Coolant temperature (iii) Lubricating oil pressure (iv) Engine speed (RPM) (v) Engine hours run (vi) Balance of fuel. (v) Safety as protection control (Trip and indication) (i) High water temperature (ii) Low Lube oil pressure (iii) Low and high speed trip (iv) High and low DC voltage (v) over speed Stop
(w) Base frame : Sturdy fabricated welded construction, channel iron base frame (duly painted ) for mounting engine and alternator as per manufacturer’s design along with AVM pads (x) Battery: 12/24 Volt, 180 AH maintenance free with leads and terminals (y) Fuel Tank : 12 hrs full load diesel storage capacity full tanks with mounting brackets factory made of 5mm thick HR. Ms sheet with level indicator fuel inlet, fuel out let, air vent, drain plug, in let arrangement for diesel filling from exterior of canopy (without opening its panel ) etc. complete all as specified and directed (B) ALTRERNATOR : 160 KVA at 0.8 PF lagging, 415 volts, 3 Phase, 4 wire, 50 Hz at 1500 RPM self excited and self regulated with AVR brushless excitation band of voltage ± 1% of rated voltage from no load to full load insulation class H, self ventilated and conforming to IS4722, BS5000, IEC-60034/1, IS0 8528, BS5514, I503046, suitable for above mentioned diesel engine. (C) ACOUSTIC ENCLOSURE : M & L for acoustic enclosure for the above 160 KVA DG set to reduce noise level to 75 dB measured at 1.0 distance for 75% load for audible frequencies as per guidelines of Central pollution Control Board with suitable inside illumination : 1 no - 1 x 18 watt FTL fitting of make Philip/Bajaj/ Crompton (D) Automatic Main Failure (AMF) control panel:- Indoor type, factory fabricated cubical type, free standing, floor mounted, AMF control panel, provided with removable rear door & hinged front door for easy accessibility, fabricated out of not less than 2.0 mm thick CRCA Sheet powder coated CPRI approved comprising of following :-
Note:- The fuel for final testing of 12 hours shall be supplied by the contractor and cost deemed to be included in the above offer. All other necessary equipment's like resistance load strip heater of suitable capacity/rating and any other items required for final testing shall be provided by the contractor without any extra cost to department."
COMPREHENSIVE MAINTENANCE OF LIFTS
Comprehensive maintenance and repairs of fully automatic electrically operated passenger lift ( Sch XII Item : 01) of any Make and installed capacity with a carrying capacity of 8 Passenger to serve (G+4 Floors) with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) comprising of all devices and accessories through 36 months for all days including holidays etc after expiry of defects liability period as shown below and all as specified and directed to Engr-in-Charge for 01 nos of lift Note : Contractor shall carryout comprehensive maintenance (routine, daily, weekly, monthly, quarterly, half yearly, yearly) through OEM as per MOU and maintain all the lifts in serviceable condition 24 hrs x 365 days with out any extra cost.
(a) 1st year after expiry of defects liability period
(b) 2nd year after expiry of defects liability period
(a) 3rd year after expiry of defects liability period
Comprehensive maintenance and repairs of fully automatic electrically operated Passenger cum stretcher lift (BOQ Item : 23.001) of any Make and installed capacity with a carrying capacity of 15 Passenger to serve (G+4 Floors) with AC variable voltage & variable frequency (VVVF drive) drive complete with all standard accessories, simplex collective automatic & manual dual controlled operation with/without attendant, automatic center opening doors with VVVF door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door) comprising of all devices and accessories through 36 months for all days including holidays etc after expiry of defects liability period as shown below and all as specified and directed to Engr-in-Charge for 01 nos of lift Note : Contractor shall carryout comprehensive maintenance (routine, daily, weekly, monthly, quarterly, half yearly, yearly) through OEM as per MOU and maintain all the lifts in serviceable condition 24 hrs x 365 days with out any extra cost.
(a) 1st year after expiry of defects liability period
(b) 2nd year after expiry of defects liability period
(a) 3rd year after expiry of defects liability period
NOTE:- (a) The contractor shall be responsible for periodical/routine maintenance, as per maintenance schedule recommended by manufacture / OEM, including renewal / replacement of parts, fittings / fixtures filling of refrigerant gas etc required for smooth functioning of the plant as per manufacturers instructions. The cost of all parts/component/Gas required for replacement are considered inclusive in quoted rate (b) The Contractor shall maintain proper records of all kinds of daily, weekly, monthly, quarterly, half yearly and yearly or whatsoever maintenance is carried out during contract period in a binded book / register and shall obtain the signature of Engineer-in-Charge every fortnightly. (c ) In case of non function of Lift penal recovery @ 3000 per day shall be effected 24 hrs after the defect is noticed or notified either in writing or through a social media message by GE or his rep. (d) Any defect in to a Motor ,ARD ,OLD,door drive , senser , limit switch ,Rope/belt ,Control Panel ,car panel with indicators, air circulating fan, Led lights & Misc Item shall be considered as outstanding defect & Panel charge will be applicable as above in Note (c ) (e) The maintenance of lifts will be carried out through OEM only. Contractor other than OEM if become lowest and awarded contract shall enter into an agreement with OEM for carrying out maintenance of lifts though OEM and copy of the contract between OEM and contractor shall be submitted to concerned GE for ref and record.
Modern Engineering Co
United Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .