| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹96.6 LAccepted-AOC 94 PHASE II HOUSEING COLONY UDHAMPUR J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹1.1 Cr+₹7.6 L (7.65%)Rejected-AOC | L2 | Rejected-AOC Not being lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Approved |
Tender Value
₹75.6 L
EMD Value
₹1.4 L
Closing Date
19 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh A K Dubey, IDSE , SE CWE
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO BLDG NO NP-07 BEING USED AS REPAIR BAY OF FD WKSP COY(S) OF EME BN (COMD) UNDER GE (NORTH) UDHAMPUR
2022_MES_516173_3
CA NO CWE/U(N)-19/2022-23
Open Tender
Civil Works
Item Rate
270 days
Udhampur
AS PER TENDER
8 documents required · 8 mandatory
₹1,000
GE (North) Udhampur
₹1.4 L
Yes
21 Aug 2023
29 Aug 2022
21 Sept 2022
29 Aug 2022
19 Sept 2022
7 Sept 2022
Amount
Roughening surfaces of old concrete surfaces by picking up, sweeping, cleaning and washing down with water to remove dust etc including taking down existing surface of any thickness of tarfelt/ plaster/ mud faska/ brick/ tiles etc. and brushing neat cement slurry @ 3 kg/Sqm, applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and provide modified polymeric five layred APP (Atactic Polypropylene) Modified Polymeric Membrane with 100 micron high molecular high density polyethylene film, Min wt of membrane will be 3.5 Kg/Sqm and bonded completely to the surfaces with min end overlap of 15 cms and side lap 75 mm (overlaps to be bounded with thermo fused by flame) and over APP applying one coat of hot blown bitument 85/25 @ 1.2 Kg/Sqm blinded with fine sand in dry condition @ 0.5 Kg/Sqm, complete all as specified and as directed by Engr-in- Charge.
15 mm thick rendering on roof of brick or concrete surfaces in cement mortar 1:4, finished even and fair without using extra cement, including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15mm thick rendering on faces of brick or concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge.
10 mm thick rendering on fair faces of brick/concrete surfaces works in cement mortar 1:3 finished even and smooth without using extra cement as in slabs facias, chhajjas and the like, complete all as specified and as directed by Engr-in-Charge.
Taking down chowkats or frames with shutters (without taking off shutters from frames) area not exceeding 1.50 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Description all as per item No 07 above but area exceeding 1.50 square metre and not exceeding 4 square metre each.
Steel window (box type) factory made with side hung shutters including pintol hinges, steel handles, steel peg stay and all locking arrangement complete, with and without glazing bars (glazed & gauzed) both leaf, dovetailed or welded including one shop coat of red oxide primer complete all as specified and as directed by Engr-in-Charge. Note : MS fillets, glazing, wire gauge shall be measured and paid separately.
BLANK
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and as directed by Engr-in-Charge.
Pre-painted coloured corrugated profiled Galvalume/Zincalume sheet with min 0.50mm TCT with BTM of 0.45mm thick conforming to IS -513(AZ-150 GSM,Al Zn alloy metallic coating 550MPA yield stress as per AS-1397),as in roof covering/clading to wall fixed with self taping screws, colour/exterior coat of silicon modified polyster/ BHP x RW paint system 20 micron top coat applied over 5 micron primer and a micron polyster back coat applied over 5 micron primer,all fixed with galvanised self drilling self tapping fastener(12-14x55 with EPDM seals), complete all as specified and directed
Pre-painted coloured plain steel profiled Galvalume/Zincalume sheet with Min 0.50 mm TCT with BTM of 0.45mm thick conforming to IS-513(AZ-150 GSM, Al Zn alloy metallic coating 550 MPA yield stress as per AS-1397) as roof ridge colour/exterior coat of silicon modified polyster/BHPxRW paint system 20 micron top coat applied over 5 micron primer and a 5 micron polyster back coat applied over 5 micron primer ,all fixed with Galvanised self drilling self-tapping fastener (12-14x55 with EPDM seals) complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame/wooden frame including punching or drilling out old glazing pins/spring clips complete all as specified and as directed by Engr-in-Charge.
5.5mm thick wire reinforced clear glass of area exc 0.5 Sqm each with glazing putty with glazing pins, complete all as specified and as directed by Engr-in-Charge.
Steel rolling shutters, having 1.25mm thickness of laths with ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as directed, gear operated type with bevel gear box and crank handle with locking arrangement, incl spring, safety lever locks mild steel with with 4-leavers, complete all as specified and as directed by Engr-in-Charge.
Preparing plastered or unplastered new decorated surfaces of walls and applying two coat of oil bound distemper over a coat of primer, complete all as specified and as directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of suitable primer, complete all as specified and as directed by Engr-in-Charge.
3 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in squares not exceeding 0.50 Sqm in each pane including taking out old broken glass any thickness size quality and description from wooden frames or stone or concrete or bricks from glazed with putty are fixed with beads complete all as specified and as directed by Engr-in-Charge.
Preparing plastered or unplastered old or new surfaces of ceiling and applying two coats of white wash, complete all as specified and as directed by Engr-in-Charge.
110 mm bore PVC SWR bends and fixed solvent etc (ISI Marked) complete all as specified and as directed by Engr-in-Charge.
Providing, Plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed by Engr-in-Charge.
Machine cut kota stone single piece slab flooring 18-20 mm thick over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl nosing over and including Screed bed or bedding layer of mortar 20mm thick in cement mortar 1:3, complete all as specified and as directed by Engr-in-Charge.
Machine cut kota stone (single piece) slab flooring 18-20 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl nosing over and including 10 mm thick CM 1:3 mortar backing for fixing the stone slab, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Rolled mild steel in roof trusses (framed) , trussed , purlins,crane gantries , rails and fastening and heavy bracket framing ( beam, tee, angle, channel or flat section or tubalar) including distance pieces conforming to Fe 410-W, Gde E-250 Quality 'A', complete all as specified and as directed.
PVC sheets 3mm thick, laminated plain coloured, marbled mosaic or mottled finish, laid with approved colour rubber based adhesive in floors as per manufacturers istructions, including taking up/down old PVC floor tiles, complete all as specified and as directed by Engr-in-Charge.
Preparation of new steel surfaces exceeding 10 cms width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide chrome primer, complete all as specified and as directed by Engr-in-Charge.
Preparation of old steel and steel surfaces exceeding 10 cms width or girth and applying two coat of synthetic enamel paint, complete all as specified and as directed by Engr-in-Charge.
Plinth protection 50 mm thick in PCC 1:2:4, type B-1 ( using 20 mm graded crushed stone aggregate) laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitument 85/25 grade and three parts of sand by weight, complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
Vitreous china water closet, 'Orissa' pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing, Vitreous china urinal, full stall type, white (excluding flushing cistern, flush pipe and waste pipe), fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing PVC valve less syphonic action type flushing cistern low level white with PVC inlet ball valve, float and handle, 10 ltrs capacity and connection to pipes including PVC connection and 32mm dia PVC long bend for squat pattern etc , set with concrete and making good to floor including taking down existing complete all as specified and as directed by Engr-in-Charge.
600 mm x 450 mm bevelled edge mirror of thickness 5/5.5mm of slected quality glass, mounted on 6 mm thick commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and as directed by Engr-in-Charge.
Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long, complete all as specified and as directed by Engr-in-Charge
110mm bore, PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors/fixed to walls, fixed in repairs , complete all as specified and as directed by Engr-in- Charge.
PVC (SWR) bend any radius, for 75 mm bore pipe, fixed with joint sealant, fixed in repair, complete all as specified and as directed by Engr-in-Charge.
PVC (SWR) floor trap plain of size 75mm , with grating including jointing with solvent cement, fixing in repair, complete all as specified and as directed by Engr-in-Charge.
Viterous china wash basin, white flat back size 580 x 450mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP grating with holes with pedestal of china ware, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Glazed ceramic tiles in vertical surface 300x 200x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surface over & including 10 mm thick rendering in CM (1:3) complete all as specified and as directed by Engr-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed by Engr-in-Charge.
Preparation old surfaces and applying two coat of oil bound distemper on walls , complete all as specified and as directed by Engr-in-Charge.
Preparing old plastered or unplastered surfaces of wall and applying two coats of cement base paint, complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan to any radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing, Steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified and as directed by Engr-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
150 mm thick cement concrete 1:2:4 type B-2 (using 20mm graded crushed stone aggregates), as in floors laid in panels, incl filling joints with filler board, etc., complete all as specified and as directed by Engr-in-Charge.
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, to obtain rough finished flat surfaces of concrete complete all as specified and as directed by Engr-in-Charge.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell /exhaust fan controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLSH 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLSH) cable with multi stranded copper conductor, medium grade (ISI marked) marked down into and including PVC concealed conduit with all accessories from terminal box to junction of wall and rest of circuit conductor wire drwan into and including surface PVC rigid non metallic conduit for one ceiling fan point controlled by one switch with also including 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item No 54 above but for bell/ buzzer point controlled by one push button on independent board with other switch or independent.
Description all as per item above No 54 but one 3/5 pin 5 Amp socket outlet on independent board .
Description all as per item No 54 above but one 3/5 pin 5 Amp socket outlet on the same board with other switch.
Description all as per item No 54 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLSH cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLSH 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Cutting chases, pinning in making good to facings in brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified and as directed by Engr-in-Charge.
Switch piano type 5 Amps single pole one way 240 volts complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Switch socket combination, 2 in 1, 3/5 pin, 5/6 & 15/16 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Bell (ding dong type), AC electronic type, 230 volts, single pole, complete all as specified and as directed by Engr-in-Charge.
Bell push 6 Amps 230 volts complete all as specified and as directed by Engr-in-Charge.
Stepped type fan regulator 120W, 230V 50 C/S, electronic, hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and as directed by Engr-in-Charge.
Switch socket outlet, 2 in 1, 3 pin, 5 Amp flush type , complete all as specified and as directed by Engr-in-Charge.
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceiling fittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store (To be measured only when found serviceable in all respects complete for reuse), complete all as specified and as directed by Engr-in-Charge.
Refixing only decorative ultra slim linear surface mounted LED lighting fixture (4 feet length), 4/5 watt, 9/10 watt, 10/12 watt, 18/20Watt LED with integral electronic driver complete making connection and testing after fixing all as specified and directed by Engr-in-charge.The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Extruded (b) Operating Voltage : Between 150 V- 270V (c) Operating Temperature : -10 to +45 Degree Centigrade (d) Lumen efficacy : Not less than 110 lm/W (e) System Lumens : Not less than 2000 lm (f) Colour Temperature : Not less than 5700K (g) Surge Voltage Protection : Up to 2KV (h) Ingress protection : IP 20 (j) Total Harmonic Distortion (THD) : Not less than 20% (k) Power factor : Not less than : 0.90 (l) Line protection : Under/Over voltage Protection (m) Input Frequancy : 50 Hz
Refixing only serviceable high bay LED lighting fixture 8 0Watt LED of input voltage AC 220V-240V, 50 Hz with colour temperature 6500K more than 1080 lumens of IP 20 complete making all connection using 1.5 sqmm copper conductor multistranded PVC insulated two core flexible cable from ceiling rose to fitting complete all as specified and directed.
Taking down Ceiling fan/ Excaust fan/wall fan,ceiling cable end, dismantling blades and removing fan and blades to store, and applying two coats painting with synthetic enamel to ceiling fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 3 core flexible cable from ceiling rose to fitting including rapair ceiling fan 1200mm sweep, oiling, greasing cleaning slot, over hauling & replacement of defective nut bolts washer etc, and rehanging/fixing only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as per the directions of Engg-in-Charge.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4mm dia galvanized iron wire lead by means of bolts, nuts, check nuts and washers of galvanized standard iron or steel all as specified or indicated in electrical plate No 3 of MES Part-I, including testing on completion including the material and labour and taking out old unserviceable earthing of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified.
Srl item No 71 Contd … (e) 15 mm nominal bore light grade GI protection pipe 7.5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge.
Taking down old serviceable/ unserviceable MCB/ DB of any type and capacity with MCB etc after disconnecting for reuse for credit , complete all as specified and as directed by Engr-in-Charge.
VTPN distribution board when MCCB 160 Amps, 16 KA ( as incommer) 4-way, including MCB 63 Amps SPN, with IP-43, IK-09 protection 415V, double door type including connections should be provided with necessary reducer lugs and including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
MCCB 4 pole,415 volts 160 Amps with breaking capacity 36 KA with thermal adjustble, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V with 200 Amps rated bus bar, double door type with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used SPN 12 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
Sheet metal enclosures for distribution board when MCB to be used SPN 02 way with IP-43, IK-09 protection 240V with 200 Amps rated bus bar, double door type including cutting chases in walls for fixing DBs making good the distubed surfaces to match with existing specifications ,fixing in repairs complete all as specified and as directed.
Sheet metal enclosure Single pole & neutral with 2 pin and earth plug and socket 20Amps, 240V complete with one single pole MCB of capacity 20 Amps of breaking capacity 10KA, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps, 'C' series 10 KA 240 Volts including providing aluminuium thimbles for outgoing cable, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
MCB SPN, 40 to 63 Amps, 'C' series 10 KA , 240 Volts including providing aluminuium thimbles for outgoing cable, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing TPN 40 to 63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Energy saving, environment friendly, pressure die casted aluminium housing & robust Highbay LED 90 watt with high efficacy & lower power consumption delivers high brightness & excellent illumination with High efficiency long life LED with SMD LED on MCPCB complete making connection and testing after fixing, including making good disturbed surface, fixed in repairs,complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Die cast aluminium (b) Optics : High Quality PC Lens (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 150 lm/W (f) System Lumens : Not less than 10000 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
Energy saving, environment friendly, pressure die casted aluminium housing & robust LED flood light 70 watt with high efficacy & lower power consumption delivers high brightness & excellent illumination with High efficiency long life LED with SMD LED on MCPCB complete making connection and testing after fixing, including making good disturbed surface , fixed in repairs, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Die cast aluminium (b) Optics : High Quality PC Lens (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 150 lm/W (f) System Lumens : Not less than 10000 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
M&L for sub main wiring with copper conductor cable (4 runs of cable) multistranded 10Sqmm PVC ISI marked with all insulated unsheathed in and including PVC rigid concealled conduit not less than 40 mm dia and 2 mm wall thickness ISI marked medium grade , with all conduit accessories from LT panel to TPN DBs such that GI shadle, GI screw, rowl plug etc. including cutting chasing and 2X10 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire, as in repair, complete all as specified and directed by Engr-in-Charge. Note:- 4 runs of 10 Sqmm (4x10sqmm ) ,2 run of 10 Sqmm (2x10 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 6 Sqmm ( 2x6 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 6 Sqmm (1x6sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repairs, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
Sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor conforming to IS-694 drawn through and including non-metalic PVC rigid concealed conduit 25 mm dia medium grade (ISI marked) with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 4 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, fixed in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
M&L for sub main wiring with copper conductor cable (2 runs of cable) multistranded 2.5 Sqmm PVC ISI marked with all insulated unsheathed in and including PVC rigid concealled conduit not less than 25 mm dia and 2 mm wall thickness ISI marked medium grade , with all conduit accessories for round ceiling light/round ceiling light recessed type/ foot lamp/focus light/ 2x2 panel light such that GI shadle, GI screw, rowl plug etc. including cutting chasing and 1x2.5 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire, as in repair, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 2.5 Sqmm (2x2.5sqmm ) ,one run of 2.5 Sqmm (1x2.5 sqmm ) cable and one metre of conduit will be measured as one unit.
New generation energy saving and environmental friendly long life LED street light of 35 watt with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment and impact resistance of IK07 with High efficiency long life LED with SMD LED on MCPCB Powered by Built-in, isolated electronic LED driver (SMPS based constant current supply) complete making connection and testing after fixing,fixed in repairs, complete all as specified and directed by Engr-in-charge. The specification of light fitting should meet the following : - (a) Housing of Light fitting : Aluminium Die Cast (b) Diffuser : High efficient LENS Optics (c) Operating Voltage : Between 150 V- 270V (d) Operating Temperature : -10 to +45 Degree Centigrade (e) Lumen efficacy : Not less than 100 lm/W (f) System Lumens : Not less than 2500 lm (g) Colour Temperature : Not less than 5700K (h) Surge Voltage Protection : Up to 4KV (j) Ingress protection : IP 65 (k) Total Harmonic Distortion (THD) : Not less than 20% (l) Power factor : Not less than : 0.9 (m) Line protection : Under/Over voltage Protection (n) Input Frequancy : 50 Hz
XLPE insulated sheathed armored heavy duty LT 1100 Volts grade cable with aluminum conductors laid in trenches/pipe, fixed to poles, walls of size 25 sqmm 4 core including taking up/down old unserviceable cables and including cutting chasing to any surface and making good the the disturbed surface to match the existing complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable, punned to 18 cm thick complete all as specified and as directed. NOTE Only punned thickness shall be measured for payment purpose.
Sub class ‘B’ old size well burnt bricks, laid flat in trenches as protection to cable, complete all as specified and as directed by Engr-in-Charge.
GI tubing light grade 40mm bore along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles complete all as specified and as directed by Engr-in-Charge.
Supply and fix on load change over switch 4 pole, 415 volts in sheet metal enclosure 4 pole of capacity 100 Amps all as specified and as directed by Engineer-in-Charge.
ASHOK KUMAR PURI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .