Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
7 Dec 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE TECH AREA AGRA
Military Engineers Services Garrison Engineer (AF) Tech Area Agra - 282008
PROVISION OF DEFICIENT BOREWELL AT AFS UNDER GE(AF) TECH AREA AGRA
2026_MES_798667_1
8200-1871/E8
Open Tender
Civil Works - Others
Item Rate
150 days
AF TECH ATREA AGRA
Class D and above category a (ii)
8 documents required · 8 mandatory
₹500
Yes
GE TECH AREA AGRA
₹91,000
Yes
14 Nov 2026
14 Nov 2026
14 Dec 2026
14 Nov 2026
7 Dec 2026
30 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Drilling of trial bore hole vertically down of size 200-300 mm dia and other machinery for rotary or DTH process or combination of both in / through any strata such as loam sand, red clay, mooram, weathers rock, rock hand lightly fractured rock, top soil, sandy clay, pebbed soil, lamy soil or any other geological formation complete all as specified and directed.
Note :- (i) Slotted pipes and pea gravel will be measured and paid separately.
(ii) Collection of soil samples and strata shall be measured and paid separately
(iii) Casing pipe shall be arranged by the contractor and the same shall remain the property of the contractor after extraction. | 285 | RM | - | - |
| 2 | M & L drilling /reaming vertically bore 550 dia in any type of strata for 250 mm ERW casing pipe for various depth as shown below including all works pertaining to bore complete all as specified and directed
Note:- (i) During boring if rocky strata is meet with than boring shall be upto 150mm dia and for the depth as require No price adjustment shall be made for reduction of bore dia due to rocky strata.
(ii) In case hard strata is meet with during process of drilling bore casing shall not be provided rocky strata and no claim shall be admissible on account of less of quantity of casing pipe brought by the contractor. | 285 | RM | - | - |
| 3 | Supply and assembling including jointing lowering and fixing in position ERW MS casing pipe 250mm dia and 8mm thick upto require depth below ground level according to strata chart in different lengths conforming to IS -3589/4270 2001 having screwed and socketed joints and including welding with coupler ring of MS Strip 40X 3 MM (04 Nos) on each joint extended 75 mm on each joint extended 75mm on each side to socket and including painting with two coats of black anticorrosive bituminous paint welding shall be done throughout the circumference of the pipe and coupler rings both sides complete all as specified and directed | 190 | RM | - | - |
| 4 | Supply and assembling including jointing lowering and fixing ERW MS Strainer ( Slotted) V weird pipe 250mm dia and 8mm thick conforming to IS -3589/4270 2001 to different length as required the size of slots shall be as designed by the contractor based on aquifers regularly arranged its equal distance all around the slotted pipe so as to make the perforated area 15% to 20% of slotted pipe jointing complete all as specified and directed by engr-in-charge. | 36 | RM | - | - |
| 5 | Description all as per item No 4 here-in-before but plain size 200mm dia | 54 | RM | - | - |
| 6 | Description all as per item No 4 here-in-before but (Slotted) size 200mm dia | 20 | RM | - | - |
| 7 | M & L Filling gravel pack provided in fine aquifers of size may be less than 2 mm and 6 mm to 20mm thickness around borewell casing pipe upto ground level as directed. | 45 | CUM | - | - |
| 8 | M & L Carrying out Development of bore well by air compressor of capacity 200 PSI 900 CFM IS 8110 as required on ground, till to get the clear water complete including carrying out yeild test complete all as specified and directed. | 36 | Hours | - | - |
| 9 | Testing of tubewell with heavy duty pump of appropriate capacity but not less than 70 Cumper hour (20000GPH) upto 24 hours or more, so as to obtained the water sand /silt free upto 20 PPM and as approved (Test record for the same duly signed by contractor and Engineer-in Charge shall be kept on record) complete all as specified and directed. | 3 | Each Job | - | - |
| 10 | M & L Carrying out Yield test (V notch type) of bore well by continuously pumping for 08 hours to determine safe pumping yield and submitting the test report in the presence of departmental representative all as directed.
Note :- T&P required for yield testing shall be arranged by the contractor without any extra cost to department. | 3 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.49 MB
1871Tender.pdf
Tender Documents • 1.51 MB
BOQ_895975.xls
BOQ • 0.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .