Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.8 LAccepted-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | ₹17.8 L Quoted ₹18.0 L | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹20.8 L+₹2.9 L (15.9%)Rejected-AOC | ₹20.8 L+₹2.9 L (15.9%) | L2 | Rejected-AOC Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹48,900
Closing Date
11 May 2021, 6:00 pmClosed
GE U WS DELHI CANTT 10
GE U WS DELHI CANTT 10
MAINTENANCE OF STP TREATED WATER PIPE LINES CLEANING OF TANK OF STP AND IRRIGATION SPRINKLERS IN THE AOR OF AGE U WS II UNDER GE U WS DELHI CANTT 10
2021_MES_435146_1
GE/WS/D-23 of 2021-22
Open Tender
Civil Works
Item Rate
120 days
GE U WS DELHI CANTT 10
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE U WS DELHI CANTT 10
₹48,900
Yes
13 Aug 2021
8 Apr 2021
13 May 2021
8 Apr 2021
11 May 2021
29 Apr 2021
Amount
Labour only for carrying out day to day treated water supply complaints of all nature, ie leakage in STP pipe lines, no water supply, any blockage on all day (including sunday & Holidays) under AGE-II W/S allied area complete all as specified and as directed. Note :- Quoted rates include notes mentioned at srl No. 2
Notes for Item No 1.00 (i)The complaints shall be attended and the defetcs shall be rectified by a team of matric qualified having minimum 03 years experienced Plumber as applicable assisted with adequate No of helpers as directed (ii)The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 200/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from contractor's dues. (iii)In case , after checking & attending the defect, if it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractors view, no recovery will be made. (iv)While attending the complaint of water supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A'. However , no extra payments shall be made for dewatering (v)Cutting of GI pipe in position and threading is also deemed to be included in the job rate (Fittings and fixtures will be measured and paid separetely under respective items of sch A.
(vi)All T&P required for attending the Complaints shall be provided by the contractor. (vii)The Pipe Fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench ,Chain wrench, Caulking tools, complete set of spanners and ladders etc.all as required at site.
Excavaiton in trenches not exc 1.5 meters wide and not exc 1.5 meters deep dor pipe line in soft/loose soil, getting out and levelling of bottom surfac e to required level complete all as specified and as directed.
Returning filling, including spreading, leveling, watering and well ramming in layers not exc 25cm thick complete all as specified and as directed.
Removing excavated material from site to a distance not exc 50 mtrs away and depositing where directed not exc 1.5 meters from the starting poing complete all as specified and as directed.
Supply and fixing in replacement of gun metal gate valve with iron wheel head screwed both ends for iron pipe , ISI marked , as per IS : 778 of following sizes complete all as specified and as directed
15 mm bore
20 mm bore
25 mm bore
Taking out/ down of Old unserviceable UPVC pipes of any rating laid in trenches including all fitting with socket ends complete all as specified and as directed. Note:- Excavation & earth work for location shall be measured & paid seperately.
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
150 mm bore
S&F Unplalsted PVC pipes of Pressure rating 10 kgf/cm2,heavy duty with all pipe fitting such as ends,elbows,union,tees,reducing tees,adopters,sockets,plugs,hose,clips etc fixed to walls with fixing arrangements such as saddles,wall clips,hooks,protective mild steel tube sleeves,ceilings,or in floors etccomplete with and cutting through walls,floors and their making good or laying in trenches and also cutting screwing and waste including jointing with jointing material complete all as specified and as directed. Note:- Excavation & earth work for new location shall be measured & paid seperately.
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
150 mm bore
Relaying of UPVC pipes retrieved againt item No 7.00 in old or new position laid in trenches of following sizes including all fitting with spigot and socket ends complete all as specified and as directed. Note:- Excavation & earth work for new location shall be measured & paid seperately.
15mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
100 mm bore
150 mm bore
Supply and fixing High density polythene pipes (HDPE) pipes, sizes as under, of pressure rating 10 kgf/cm2, heavy duty confirming to IS:4984:1995 fixed complete to walls with fixing arrangements such as saddles (snap clips), wall clips, hooks, protective mild steel tube sleeves , ceilings or in floors etc., complete with and including taking down old Pipe complete all as specified and as directed. Note :- Excavation & earth work shall be measured & paid separetely.
40 mm OD bore
50 mm OD bore
90 mm OD bore
110 mm OD bore
160 mm OD bore
Supply and lay 3 layer (inner antmicrobial,outer UV stabilized) ISI marked IS-15801, PPR pipe SDR 11 (PN-10) and plain fitting in trenches/wall/celling or laying in floors complete of 63 mm size outer dia including all fittings with and including taking down old Pipe com
Material and Labour for CI/DI fittings/specials such as Tees, bends (any type, radius and angle ) tapers any type, collars,tail pieces,caps and plugs up to 150 mm bore confirming to IS: 9523 complete all as specified and as directed
Supply only UPVC Socket ISI 4985:2000/Equivalent Marked of following sizes complete all as specified and as directed
15 mm bore
20 mm bore
25 mm bore
40mm bore
50mm bore
80mm bore
100mm bore
150mm bore
Supply only UPVC Elbow ISI ISI 4985:2000/Equivalen Marked of following sizes as under complete all as specified and as directed
15 mm bore
20 mm bore
25 mm bore
40mm bore
50mm bore
80mm bore
110mm bore
150mm bore
Supply only UPVC reducing socket ISI ISI 4985:2000/Equivalen Marked of following sizes as under complete all as specified and as directed
25 x15 mm bore
20 x 15 mm bore
25 x 20 mm bore
50 x 40mm bore
150 x 100mm bore
Supply only of PP-R Gate valves (brass insert) ISI 15801:2008 Marked of sized as under complete all as specified and as directed
20 mm bore
25 mm bore
40 mm bore
50 mm bore
63 mm bore
Taking up or down GI steel tubing with connection including cleaning for removal complete all as specified and as directed of the follwing sizes. Note:- Excavation & earth work for new location shall be measured & paid seperately.
15 mm dia
20 mm dia
25 mm dia
Supplying,laying,and testing of GI steel tubing medium grade of following size in old or new position in trenches with neccesary fixing arrangements and including providing new GI fitting complete all as specified and as directed. Note:- Excavation & earth work for new location shall be measured & paid seperately.
15 mm dia
20 mm dia
25 mm dia
Supplying,laying,jointing and testing of GI steel tubing medium grade of following size in old or new position as in walls/ceiling/floors with neccesary fixing arrangements and including providing new GI fitting complete all as specified and as directed
15 mm dia
20 mm dia
25 mm dia
Supplying, fixing, jointing & testing cast Iron Sluice Valve of following sizes, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top complete with Nuts, Bolts, washers and rubber gaskets of following sizes including taking out of unserviceable sluice valve complete all as specified and as directed.
80 mm dia
100 mm dia
150 mm diae
200 mm dia
Supply, fixing, jointing and testing of Cast iron Non Return valve of following sizes, without by pass arrangement , Swing type, confirming to IS 5312, flanged ends, pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
80 mm dia
100 mm dia
Supply and fixing Cast Iron foot valve, sizes as under, flanged ends, swing type opration with rubber sheet, as per IS : 4038 PN0.2 including taking out unserviceable foot valve complete all as specified and as directed .
50 mm Bore
80 mm Bore
100 mm Bore
Supply, installation and testing of flanged ends Water Meter ISI marked woltman type, Class 'B' of following sizes and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, including cutting of pipes complete all as specified and as directed. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item
50 mm bore
80 mm bore
100 mm bore
150 mm bore
Supply only of Lead pig bar complete all as specified and as directed
Supply only of Spun Yarn complete all as specified and as directed
Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 200 Amps with breaking capcity 36 KA , 415 volts, complete all as specified and as directed.
Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 100 Amps with breaking capcity 25 KA , 415 volts, complete all as specified and as directed.
Supply and fixing LED tube light fitting integral type suitable for 1 x 18 watts, 230 volts, connector block etc with all accessories internally prewired and including connecting with twin core flexible copper cable of suitable size including taking down/out fitting as existing at site complete all as specified and as directed.
Material and labour for Fabrication, welding and fixing of MS frames made out of MS angle/ flat of any size as required at site for repair/replacement of valve pit cover / Sump manhole cover, Stair case steps and all other iron works including painting two coats with synthetic enamel paints over a coat of red oxide primer complete all as specified and as directed
Supply only 20 mm bore Bib tap of PTMT, any tint, high pressure screwed for male/ female threaded, for pipe of size 20 mm bore complete all as specified and as directed.
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, pillars etc but excluding ashlar facings, dressed stone work and precast articles
PCC 1:4:8 type D-2 using 40 mm graded mechanically crushed stone aggregates as in foundation, sub base and mass concrete complete all as specified and as directed.
PCC 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregates as in coping, grouting MS frame etc including form work complete all as specified and as directed.
M&L for brick work with subclass B bricks straight or curved on plan to any radius in full brick thick( 23 cm ) walls built in cement mortar (1:4) complete all as directed and as specified
Rendering 10 mm thick with cement plaster (1:6) on fair faces of brick walls for finishing the surface fair and even complete all as specified and as directed
M&L for preparation of Old surfaces of wall including washing rubbing down, filling of cracks and stopping of distemper and painted surface and applying two coats of cement base paint including necessary scaffolding work etc. complete all as specified and directed
M&L for preparation of Old surfaces of wall including washing rubbing down, filling of cracks and stopping of distemper and painted surface and applying one coat of distemper oil emulsion including necessary scaffolding work etc. complete all as specified and as directed
Material and labour for painting to steel and iron surfaces by using spray Gun with one coat red oxide and one coat of synthetic enamel paint as per existing pattern after preparation of old surfaces of any description over 10 cm in width or girth complete all as specified and as directed
M & L for cleaning of treated water tank of storage capacity of water upto 50 CUM throughly by removing mud,grit etc from the tank complete all as specified and as directed as directed. NOTE: proper cleaning with brush and removing all dirt from tank.
Manually Trench drill upto 150mm bore dia complete all as specified and as directed
Supply, installation and testing flanged ends strainer / dirt box 100 mm bore with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, complete all as specified and as directed. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item
Supply and FIX in replacement of flexible heavy duty hose pipe ISI marked of size 65 OD required at site complete all as specified and as directed.
Supply and FIX in replacement of flexible heavy duty hose pipe ISI marked of size 90 OD required at site complete all as specified and as directed.
Supply and FIX in replacement of MS Pipes heavy grade with all fittings laid in floors,Treanch or fixed to walls and ceilings including welding as required at site complete all as specified and as directed.
Supply, installation and testing flanged ends strainer / dirt box 150 mm bore with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/vertical position, complete all as specified and as directed. Note :- Flange joints including jointing materials shall deemed to be included in the unit rate of this item
Supply & Fixing in replacement of butterfly valve of following size/bore conforming to IS 13095 complete all as specified and as directed
100 mm bore
150 mm bore
80 mm dia
50 mm dia
Supply and lay 3 layer (inner antmicrobial,outer UV stabilized) ISI marked IS-15801, PPR pipe SDR 11 (PN-10) and plain fitting in trenches/wall/celling or laying in floors complete of 25 mm size outer dia including all fittings with and including taking down old Pipe complete all as specified and as directed. Note :- Excavation & earth work shall be measured & paid separetely.
Preventive Maintaince of Disc filter (120 mesh) 50m3 /hr having an inlet & two outlets connections of 3", 2 pressure guage ports of 3/4" ,a helix made of fiber glass reinforce polyamide at base of disc filter cartridge to create a helical effect in the incoming water ,spinning particulate in suspension away from the filtering element and so minimizing cleanings frequency ,3/4" outlet for flushing at bottom of filter & maximum working pressure of 14 bars including taking out/in.
Periodical Cleaning of Sewage well of size 5m dia and 7.5m deep and Removing of settle down Sewage sludge cum mud/De-Silting etc complete all as specified and as directed.
Periodical Cleaning of Sewage and Removing of settle down Sewage sludge cum mud/De-Silting etc. all as required at site and directed for Equalization tank of capacity upto 70CUM complete all as specified and as directed.
M & L for cleaning of filter feed tank of capacity upto 50 cum, thoroughly by removing mud, grits etc from the tank complete all as specified and as directed.
Material and Labour for cleaning of MBBR-1 and MBBR-2 tank and taking out complete FAB PVC media from the tank and re-filling the same after washing/cleaning throughly of STP by removing mud, grits etc from the tank complete all as specified and as directed.
Note for item No 54& 55 :- (a) Cleaning inner surface of tank complete by scraping with steel wire brush and and removing mud and sludge collected inside the tank manually at a distance not exceeding 50 mtr complete all as specified and as directed. (b) Washing with clean water and bleaching powder mixture throughly complete tank internally and removel of left out sludge if any at site at a distance not exceeding 50mtr complete all as specified and as directed.
Notes for items Srl No. 52 to 55 above: Rate quoted shall include the aspects :- (a) Diesel Driven Pump Set of appropriate capacity not less than 5/7.5 HP with operator including necessary POL required at site for De- Watering of Sewage septic water including PVC heavy duty flexible hose pipe for suction and delivery purposes. (b) Tractor mounted septic storage tank of appropriate capacity not less than 1 KL with driver directly collected from the soak well and disposing the same to the location where approved by the Delhi Canttonment Board/PCB. c ) Sewage Sludge disposable tractor/truck with driver and POL required for the same (duly covered with necessary tarpaline ) and disposing the same to the location where approved by the Delhi Canttonment Board/PCB (d) Labour element and T&P required for removal of settled down sewage sludge/mud inside the sewage tank for scooping out from inside and below the septic/staining sewage water inside the well and lifting the same and deposited on top and near by the sewage tank where directed and further to removal the same where approved by the Delhi Canttonment Board/PCB (e ) Appropriate qty of Phenyle required at site for Sterilization of sewage sludge being collected in the Sewage tank and complete all as specified and as directed. (f) Necessary Oxygen Mask, Gloves, Gum Boot and all other safety aspects and including necessary Phawda, Steel Bucket, Manila rope etc. required at site and complete all as specified and as directed.
An amount of Rs 20452.50 shall be deducted from BOQ on account of schedule of credit
Ayushmat Contractors
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .