| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹30.7 L+₹8,941 (0.29%)Rejected-Finance VIJAY NAGAR KUMHARTOLI HANSARI INFRONT OF JIGYASA INTER COLLEGE JHANSI | JHANSI | UTTAR PRADESH | 284001 | L2 | Rejected-Finance Not become lowest bidder | |
| 3 | L3₹31.0 L+₹33,916 (1.11%)Rejected-Finance D12 GROTH CENTRE COLONY BIJAULI JHANSI U P | JHANSI | UTTAR PRADESH | 284001 | L3 | Rejected-Finance Not become lowest bidder | |
| 4 | L4₹31.3 L+₹65,792 (2.15%)Rejected-AOC NEAR RANGE OFFICE CHOUBYANA TALBEHAT DISTT LALITPUR UP | TALBEHAT | LALITPUR | UP | L4 | Rejected-AOC Not become lowest bidder | |
| 5 | L5₹31.8 L+₹1.2 L (3.89%)Rejected-Finance WARD NO 4 NEAR MASZID BHATTAGAON DISTT JHANSI 284001 UTTAR PRADESH | JHANSI | UTTAR PRADESH | 284001 | L5 | Rejected-Finance Not become lowest bidder |
Tender Value
₹37.4 L
EMD Value
₹74,700
Closing Date
4 Oct 2022, 6:00 pmClosed
Lt Col Deepak Kumar
Garrison Engineer Jhansi
SPL REPAIR TO AC SHEET INCL VALLEY GUTTER IN BLDG NO T-98 OF 129 ARMD WKSP AND PROVN OF SWAN NECK WITH CONCERTINA COIL OVER EXISTING BOUNDARY WALL AT AGE B/R-I UNDER GE JHANSI
2022_MES_550486_1
GE/JHA/TOK/38 OF 2022-2023
Open Tender
Civil Works
Item Rate
180 days
GE Jhansi
Please refer tender documents
7 documents required · 7 mandatory
₹500
Yes
GE Jhansi
₹74,700
Yes
1 Dec 2022
7 Sept 2022
7 Oct 2022
7 Sept 2022
4 Oct 2022
20 Sept 2022
Amount
Demolition of brickwork or stone masonry, built in cement mortar or cement lime mortar including all quoins, pillars etc, but excluding precast concrete articles, complete all as specified and directed.
Excavation im trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation and sewer pipe line or for manholes not exceeding 10 Sqm on plan and not exceeding 1.5m in depth in hard/dense soil And getting out all as specified.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil all as specified.
Removal of excavated material (soil) to a distance not exceeding 50 metre, upto 250 metre and depositing where directed at a level not exceeding 1.5 m above the starting point all as specified.
M&Lplain Cement Concrete 1:3:6 type C-2 (Nominal mix) using 20 mm graded crushed stone aggregate as in bed to drain pipes including packing under and haunching against the sides of pipe after they are laid and tested for 200mm pipe all as spd in.
M&L RCC Precast pipe NP3 200mm dia including collar laid on PCC bed I and tested complete all as spd .
M&L for old size brick work with fly ash bricks straight or curved on plan exc 6 m mean radius built in cement mortar (1:4) complete all as specified and directed.
M/L for brick work with fly ash old size bricks straight or curved on a plan exc 6m mean radius built in CM (1:6) complete all as specified and directed.
M&L for old size brick work with fly ash bricks straight or curved on plan to any radius built in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15 mm thick rendering in CM (1:6) on fair / other than fair faces of brick work finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering in CM (1:4) on external surface fair / other than fair faces of brick wall finished even and fair with WPC as per manufacturer instruction complete all as specified and directed .
Dismantling of unframed timber scantlings 40 sq. cm and over in section, in any position
Dismantling of asbestos cement corrugated/semi corrugated sheet in roof covering complete all as specified and directed.
S&F for Pre-painted galvatume aluminium Zinc coating GI based corrugated double ribbed trapezoidal frofile steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in sloped roof covering/cladding to wall, fixed with self tapping screws (L-type or J-type or cranked hook bolts) all as specified and directed. Note:- 1. Height of bldg appx 5.5 to 8 mtr. 2.Replacement only broken and unserviceable sheets
-Ditto- all as item No 13.00 as above but half round sheet at edges fixed to sloped roof of wide N.exc 0.9mtr all as specified and directed. Note:- 1. Height of bldg appx 5.5 to 8 mtr.
S&F for 6mm thick asbestos cement, corrugated or semi-corrugated sheets as in sloped roof covering/ cladding to wall etc, fixed with L-type or J-type or cranked hook bolts all as specified and directed. Note:- 1. Height of bldg appx 5.5 to 8 mtr. 2.Replacement only broken and unserviceable sheets
-Ditto- all as item No 15.00 as above but half round sheet at edges fixed to sloped roof of wide N .exc 0.9mtr all as specified and directed. Note:- 1. Height of bldg appx 5.5 to 8 mtr.
S & F rolled mild steel frame work as in roof trusses (framed), heavy bracket framing for valley gutter , purlins, rails and fastenings and etc (Beam, tee, angle, channel or flat sections) including distance pieces, cleats, Hold fast etc., quality confirming to GDE Fe 410-S complete all as specified and directed by Engineer-in-charge. Note:- 1. Height of bldg appx 5.5 to 8 mtr. 2.Replacement only broken and unserviceable frame.
M&L for PCC 1:2:4 type B1 using 20mm graded aggregate as in bed block for hold fast, coping, surface ,benching etc., complete
M & L for 1.25mm Plain GI sheeting, in hips, valley gutters,drip and straight flashings (length and girth as fixed) fixed to frame work with butt welding Complete all as spd Note:- 1. Height of bldg appx 5.5 to 8 mtr.
M&L for preparation of new plaster surfaces, apply primer and alkali resistant priming paint and applying two coat cement base paint over a coat of primer on walls complete all as spd. Note:- 1. Height of bldg appx 5.5 to 8 mtr and rate include for necessary Scaffolding/Staging with Safty Precaution
Complete removal of exisiting treatment, washing and rubbing of old surfaces of wall and applying two coats of cement base paint over a coat of primer on walls complete all as spd. Note:- 1. Height of bldg appx 5.5 to 8 mtr and rate include for necessary Scaffolding/Staging with Safty Precaution.
M&L for preparation of new plaster surfaces and applying three coat of white wash on walls complete all as spd Note:- 1. Height of bldg appx 5.5 to 8 mtr and rate include for necessary Scaffolding/Staging with Safty Precaution
Complete removal of exisiting treatment, washing rubbing of old treetment and applying three coats of white wash on wall sufaces complete all as specified and as directed. Note:- 1. Height of bldg appx 5.5 to 8 mtr and rate include for necessary Scaffolding/Staging with Safty Precaution
Preparation of New or previously untreated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of Synthetic enamel paint (Ordinary tint) over a coat of red oxide. Note:- 1. Height of bldg appx 5.5 to 8 mtr and rate include for necessary Scaffolding/Staging with Safty Precaution.
Preparation of Old or previously treated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coats of Synthetic enamel paint (Ordinary tint) . Note:- 1. Height of bldg appx 5.5 to 8 mtr and rate include for necessary Scaffolding/Staging with Safty Precaution.
Demolition of cement concrete in ground floor including terrazo flooring and paving n exc 15cm thickness (below or above the ground level) built in cement mortar. Complete all as spd
M/L for 50mm thick PCC 1:2:4 type B0 (using 12.5mm graded aggregate) as in Flooring complete all as specified and directed
Demolition and breaking up drain pipes (AC or Reinforced concrete) set in cement mortar complete
M&L for PVC(SWR) pipes single socketed in any length with rubber joint of dia 200 mm fixed on wall with necessary clamp complete all as spd Note:-FI 25 X 3mmfor Purpose made clamp not ncluded in the same item and measured seperatly
M&L for PVC(SWR) Bend single socketed with rubber joint of dia 200 mm any radius complete all as spd
M & L for cement concrete 1:4:8 type D2 using 40 mm graded aggregate as in foundation and mass concreting complete all as specified and directed.
M&L for mild steel hold fast ,clamp,hook & stay and similar small articles conforming to Fe-290 Gde-165, complete all as specified and directed.
M & L for RCC 1:2:4 (nominal mix) using 20mm graded aggregates as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete complete all as specified and directed.
M & L for RCC 1:2:4 (nominal mix) using 20mm graded aggregates as in column ,pillars, piers, post complete all as specified and directed.
M & L for RCC RCC 1:2:4 (nominal mix) using 20mm graded aggregates as in beams,band, cantilevers, bressummers etc complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter for rough finished surface complete all as specified and directed.
Form work to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, lintels/bands, cantilevers, shelves including supports, overhangs,etc. also splays between floors and beams, etc complete for rough finished surface all as specified and directed.
M&L for mild steel deformed TMT bars 10mm dia and over (as in reinforcement) cut to length, bent to shape require including cranking, bending spirally for hooking for column, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
All as per item No 40 herein before but 5 mm dia to 10 mm dia
All as per item No 41 herein before but as in spacers and stirrups etc.
S&F of PVC (SWR) pipe of 75 mm nominal dia size, wall thickness of 3.5 mm, Type A, in any length, single socketed type as per IS : 13592-1992 with latest amendment, having one end of the pipe as plain and other end socketed, duly fixed with cement solvent etc, complete pipe duly laid in trenches or in floors, complete all as directed.
S&F 75 mm bore PVC (SWR) bends of any radius, complete all as specified and directed.
S & F concertina coil 600 mm dia of each coil and 10 Nos coil/round for one RM fixed with top of angle iron Y Sec of boundary wall complete as specified & directed.
Galvanised. 2 strand, steelbarbed wire 2.24mm diabarbed with 2mm dia barbs at75mm spacings and strainingand fixing to any type ofstandard rails strain- ingbolts, including, securing ortying at crossings with andprovision of galvanised mildsteel wire, as directed.
Design, Fabricate, Supply, Installation, Testing & Commissioning of outdoor type dust proof & vermin proof cubical panel board compartmentalized with separate bus bar and cable alley chambers suitable for 3 phase, 4 wire, 415 volts, 50 Hz, Ac supply system as per latest IS/IEC standards & regulations, factory fabricated in an approved factory (manufacturer possessing CPRI test report for equivalent ratings) having modern fabrication facilities, made out of CRCA sheet steel of 3.15mm thick for outer shell and 2mm thick for inner shell with front and rear openable double leaf doors with two point locking arrangement i.e. locking system with handle up & down arrangement & pad locking facility. Complete panel board shall be applied with powder coat painting of approved shade duly pretreated with seven tank process and suitable packing material for IP-54 degree of protection and including provision of 50mm x 50mm x 6mm angle iron base frame of suitable size for mounting the panel board with a minimum ground clearance of 450mm above GL to the bottom of panel including PCC foundation with PCC 1:3:6, type C2 using 40mm graded stone aggregate. Detachable gland plates including double compression stainless steel cable glands of suitable size shall be provided for all incoming and outgoing cables. Steel plate Danger Notice Boards (02 Nos) LT 415/440 Volts, and manufacturer's name plate shall be riveted on external doors of feeder pillar box. The size of panel board shall not be less than 1800mm x 1500mm x 450mm (outer dimensions) for accommodating and including provision of following switchgear, control gear and accessories including internal wiring using copper flexibles and lugs of suitable grade/capacity complete all as specified and directed :-
Note : (i) Factory made name plates with feeder names/ Bldg Nos shall be fixed on relevant incomer/outgoing MCCB doors. (ii) The contractor shall submit set of all drawings of the LT Pillar Boxes and its components in duplicate and get the same approved from GE before commencement of production. The contractor shall furnish all details and clarifications required if any for scrutiny and evaluation. Manufacture of material to be supplied shall be done strictly as per approved drawing.However, approval of drawing shall not absolve the contractor/supplier of his liability for ensuring correctness according to applicable standards & regulations.
Supply and fix MCB distribution board, TPN, 4 way 415 Volt in sheet steel powder painted enclosure double door type with IP 43 degree of protection with built in copper bus bar, neutral link and earth link complete including cutting the wall surfaces for flush mounting of DB and making good with cement plaster, putty and paint to match with the existing surface all as specified and directed. Note: MCBs shall be measured and paid separately.
Supply, laying, testing & commissioning of Power Cables, Aluminum Stranded Conductor 120 sqmm, 3.5 core, XLPE Insulated, Cores laid up, PVC Inner sheathed, Armoured with galvanized wire or galvanized steel strip, overall PVC Sheathed, 1100V grade as per IS 7098(Part 1) 1988 complete laid in trenches / floors / fixed to poles / walls / drawn through pipes etc including provn of lugs, glands, nuts, bolts & washers etc for connecting in LT feeder pillar box / transformer bushings and testing on completion all as specified and directed. Note: Excavation, earth work and provn of cable covers / protection pipe etc shall be measured and paid separately under relevant items of BOQ.
All as per item No. 50.00 here-in-before but of size 25 sqmm, 4 core
M&L for Circuit/submain wiring alongwith earth wire 2 runs x 4 sqmm + 1 run x 4 sqmm with FRLS insulated copper conductor, single core cable drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ floor etc complete all as specified and directed by Engineer-in-Charge. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
All as per srl item no. 52.00 here-in-before but 2runsX2.5 Sqmm +1runX2.5Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
All as per srl item no. 52.00 here-in-before but 2runs1.5 Sqmm +1runX1.5 Sqmm. Note: Three runs of copper cable and one run of PVC conduit shall be measured as one unit length
Supply and fix modular MCB protected plug and socket board in sheet steel enclosure with one number 20 A rated mini MCB TP and 20 A rated 3 pin plug, 240 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface or fixing on structural steel surface all as specified and directed.
Supply and fix Industrial wall mounted plug and socket 32 Amps rating 3P+N suitable for IP44 in sheet steel enclosure with 4 pole MCB of suitable rating 415 V, 50 Hz complete including cutting the wall surfaces for flush mounting of socket board and making good with cement plaster, putty and paint to match with the existing surface or fixing on structural steel surface as specified and directed.
Supply & fix Air Circulator fans 230 volts single phase oscillating 600 mm sweep suitable for wall mounting incl taking down existing u/s ceiling fans and deposited to E&M store yard complete all as specified and directed.
Supply and fix in repalcement of LED midway light 70 watt, 230 V AC , indoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant with driver and lamp complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. all as specified and directed by Engineer-in-Charge.
Supply and fix LED street/security light fitting 60 watts with high efficiency long life LEDs with In-built electronic driver complete housed in pressure die-cast aluminium housing covered with polycarbonate cover with IP66 degree of protection including GI pipe bracket made up of 25mm dia medium grade GI pipe of length 1.50m bent to required shape and fixing on walls with suitable MS clamps(02Nos) made up of 25mmx4mm MS flat, nuts, bolts and washers and provision of 3 core twisted flexible copper cable of size 0.5 sqmm from ceiling rose to connector of fitting complete all as specified and as directed.
Supply and fix Exhaust Fan , AC , Single phase 230/240V of size 450mm sweep with louver incl taking down existing unserviceable fan and deposited to E/M yard store as specified and as directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. and removing materials to store for taking credit and making good disturbed surfaces of walls, floors, etc.complete all as specified and directed.
M&L for Point wiring with 1.5 Sqmm FRLS insulated, unsheathed, multistranded, 1100 Volts grade copper conductor cable single core conforming to IS:694 along with one run of 1.5 Sqmm FRLS insulated copper conductor cable green in colour for continuous earthing drawn through and including medium grade rigid PVC conduit conforming to IS:9537 (Pt-III) and its all accessories/junction boxes/ inspection covers etc of suitable size but not less than 20mm concealed in wall/ on floor etc including provision of pressed steel terminal box of thickness not less than 18 SWG, with earth dolly of suitable size concealed in wall and covered with 3 mm thick phenolic laminated hylam sheet fixed with brass /GI screws for mounting switches, sockets, fan regulator, etc. complete all as specified and directed by Engineer-in-Charge for the following points:-
One light /fan/exhaust fan/call bell point controlled by one switch
One 6A socket point controlled by one switch on independent board
One 6A socket point controlled by one switch on same board
All as per srl item no. 63.00 here-in-before but with 2.5 sq mm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for one 16 Amp socket point controlled by one 16 Amp switch on independent board.
S&F, Switch piano type, single pole, one way, 6 amps, 240 volts, complete all as specified and directed.
S&F, Socket, 6 pin, 6/16 Amp, multipurpose 240 volts, complete all as specified and directed.
S&F, Switch piano type, single pole, one way, 16 amps, 240 volts, complete all as specified and directed.
S&F, Socket, two-in-one, 5 pin, 6 Amp, universal type, 240 volts, complete all as specified and directed.
Supply and fix electronic fan regulator in 5 steps, 240V, 50Hz complete all as specified and directed.
S&F, Ceiling rose, three terminals, bakelite body, 240 volts, complete all as specified and directed.
M&L for Earthing complete with galvanised iron earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to GI wire 4 dia mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth wire protected by 15mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed. Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe, earth wire upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m depth and getting out in any type of soil for laying of cables/ for erection of poles/ for stay assembly etc complete all as specified and directed.
Supply and spread M-sand in trenches for cushioning of cable / in the yard of outdoor substations complete all as specified and directed. (Note: Punned down thickness only shall be measured for the purpose of payment)
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exceeding 25cm complete all as specified and directed.
Removing surplus excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
Supplying and laying in replacement of un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm for cable protection in trenches complete all as specified and directed.
M&L for cutting of existing road / hard standing up to 15 cm depth for laying of pipe lines and making good the disturbed surfaces by providing PCC 1:2:4 type B-1 (using 20mm graded aggregate) after laying of pipes lines / cables and returning filling of soil, complete all as specified and directed. Note:- Excavation and earth work below road / hard standing will be measured and paid under relevant items.
Supply and fixing of 100mm dia bore tubes, 'light grade' galvanized, with all fitting and fixed complete to walls/ poles or laid in trenches/ floors for cable protection complete all as specified and directed.
Material and labour for Double wall corrugated HDPE pipe, ISI marked of outer dia 50mm, inner dia 38mm with smooth internal and profiled external surface, non-pressure type, laid in trenches/floors/duct or fixed on walls /pole including all connections, accessories like socket, couplers, bends, etc for protection of LT cable XLPE grade 1100 volts complete all as specified and directed by Engineer-in-Charge.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .