Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹89.5 LAccepted-AOC 184 C 13 THURAIYUR SAMINATHAN NAGAR PERAMBALUR SALAI TIRUCHIRAPPALLI TAMIL NADU 621010 UDYAM TN 27 0052941 | TIRUCHIRAPPALLI | TAMIL NADU | 621010 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹90.9 L+₹1.4 L (1.56%)Rejected-Finance 3 165 1A KAMARAJ NAGAR KANGAYAMPALAYAM SULUR COIMBATORE TAMIL NADU 641 401 | COIMBATORE | COIMBATORE | TAMIL NADU | 641401 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹94.3 L+₹4.8 L (5.41%)Rejected-Finance THE JEHOVAH SHALOM 21 THIRUMALAISAMY STREET LAKSHMI NAGAR EXTN KAVUNDAMPALAYAM COIMBATORE 641030 | COIMBATORE | COIMBATORE | TAMIL NADU | 641030 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹1.0 Cr+₹13.5 L (15.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹1.3 Cr+₹35.6 L (39.8%)Rejected-Finance 121004 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹1 Cr
EMD Value
₹1.8 L
Closing Date
11 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF TRIVANDRUM
CWE AF TRIVANDRUM HQ SAC IAF COMPLEX AKKULAM THURUVIKKAL POST TRIVANDRUM 11
Provn of URC at AF STN Sulur
2024_MES_665137_2
CWE(AF)/TVM/82512E8 URC at SULUR
Open Tender
Construction Works
Lump-sum
365 days
Sulur
Class C category a(i)
7 documents required · 7 mandatory
₹1,000
GE AF Sulur
₹1.8 L
Yes
26 Nov 2024
13 Sept 2024
14 Oct 2024
13 Sept 2024
11 Oct 2024
27 Sept 2024
13 Sept 2024 - 19 Sept 2024
Amount
GENERAL SUMMARY (Note : Schedule 'A' Part I 'Building/ Structure' is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6)
Schedule ‘A’ Part I“BUILDING/STRUCTURES ” M&L for Design, supply and erect Pre-engineered steel bldg steel structure of Internal size 15M x 30M with Ridge height as per design and 3.5M height at both ends, with Alu-zinc coated colour profiled sheet, Roofing sheets 0.50 mm thickness and yield strength of 550 mpa in wall cladding and roofing (approx 15% roof/wall sheeting with 2mm thick Polycarbonate sheet with integrated wire mesh) incl RCC foundation and plinth upto0.45m above ground level, AAC block masonry cubicals of height 2.4m with 03Nos aluminium doors, ceramic tile flooring, Plinth protection, anchor bolts, base plates and all structural steel items, rain water gutters and down take pipes with entry and exit doors with steel frames and shutters, aluminium doors, turbo air ventilators and Exhaust fans complete all as specified and as directed by GE
Schedule ‘A’ Part I“BUILDING/STRUCTURES ” M & L for Design, construction of Toilet facilities for Unit Run Canteen for Staff and Visitors with permanent specifications such as RCC M-25 (Design mix), framed construction with AAC solid block masonry, ATT and PU based water proofing treatment etc etc complete all as specified and as directed by GE Note : - (i)The contractor should design forundation and super structure for the building and the foundation should be designed according to the soil report and structural drawings of the entire structure shall be submitted after vetted from IIT/NIT/IISC Bangalore along with design calculation sheet. (ii) The toilet block shall be desinged and built according to the architechtural drawings along with schedule of finishes. (iv) Detailed yard stick along all connected documents shall be submitted before execution of the work for approval of accepting officer. Quoted rates are deemed to be included for all these provisions
GENERAL SUMMARY (Note : Schedule 'A' Part II to VII are prepriced by MES under Ser No.4 and 5.Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only)
Total of Schedule ‘A’ Part II “INTERNAL ELECTRIFICATION”
Total of Schedule ‘A’ Part III “ PATH/ HARD STANDING”
Total of Schedule ‘A’ Part IV “ AREA DRAINAGE”
Total of Schedule ‘A’ Part V “ SEWAGE DISPOSAL”
Total of Schedule ‘A’ Part VI “ INTERNAL WATER SUPPLY”
Total of Schedule ‘A’ Part VII “ EXTERNAL WATER SUPPLY”
Total of Schedule ‘A’ Part VIII “ EXTERNAL ELECTRIC SUPPLY”
Sch 'A' Part- IX - MISCELLANEOUS ITEMS (Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only. Bidder shall insert their rate in Green field under column 6)
S & F modular flush box for mounting of modular cover plates 8 modules complete all as specified and directed
M &L for Cutting 80mm dia cast iron and reducing to required length before laying pipes in position for insertion of new tees,branches of different sizes as per site requirement complete all as specified and directed
M & L for Riddling Sand obtained from excavation for cable protection 8cm under the cable and 15cm above the cable in trench and get the thick layer of 18cm after ramming complete all as specified and directed. Note :- In case sufficient sand not obtained from excavation, the quoted rate is deemed to be inclusive for the required additional qty obtain from out side MD land as directed.
M & L for Protection to cable with one layer of Fly ash bricks of size 23 x 10 x 10 cm laid flat butting to each other in such a way that the length of the bricks is at right angle to the central axis of the cable complete all as specified and as directed.
S&F angle cock, cast copper alloy fancy type chromium plated with long shank & cup concealed type for PPR pipe of 16mm bore complete all as specified and as directed.
S&F LED light fitting 1 X 10 W, 220 V AC decorative box type with driven holder incl LED tube light connecting three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F steel body exhaust fan with lovers of size 300nmm sweep, 900RPM 230 volts single phase AC supply complete with bolts, nuts and washers suitably embedded in the wall/ prefabricated sheet etc including making suitable opening and provisioning of flexible cord copper of size 23/ 0.0076 from ceiling rose to exhaust fan for giving connection complete all as specified and as directed.
S&F LT panel outdoor type (CPRI approved) made out of ms sheet 3.15mm thick angle iron of size (50x50x6 mm) with locking arrangement and painting with following asseccories suitable for incoming/outgoing arrangements:- (a) MCCB 100 Amps 4 Pole A - 01 No (b) MCCB 63 Amps 4 Pole A - 01 No (c) MCB SPN 6-32 AMP, 10 KA - 02 Nos (d) Aluminium bus bar 150 Amp TPN - 01 Set (r) LCD multi function meter - 01 No (f) Indicating lamp set -01 Set of three (g) CT of suitable ratio 100/5 A - Set of 3 Nos
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth Strip of size 32x6mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
M&L Earthing with Galvanised Earth Plate Electrode 600x600x 6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected with Galvanised Earth wire of 4 mm (upto 7.5m length) by means of Bolts, Nuts, Check Nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar including GI 40mm bore (dia) light grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt, Magneisum Sulphate (1 : 1 : 0.5) in alternate layers of not exc 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of size 350x350x50 mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, Funnel with GI Watering Pipe 20mm bore (dia) medium grade including necessary Excavation in any type of soil, Returning, Filling in and Removal of surplus Spoil disposal to out side MD land and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including taking down old unserviceable one, complete all as per specified and as directed.
Vishnu Infrastructures (BID ID -3127836)
KUMAR AGENCIES (BID ID -3128515)
SIVAN BUILDERS (BID ID -3136751)
Neptune Engineers and Builders (BID ID -3128379)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .