| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAccepted-AOC 13 29 304 IIIRD FLOOR EAST PATEL NAGAR OPP HOTEL SIDDARATHA NEW DELHI 110008 | WEST | DELHI | 110008 | ₹1.5 Cr | L1 | Accepted-AOC QUOTED AMOUNT LOWEST |
| 2 | L2₹1.6 Cr+₹2.5 L (1.60%)Rejected-Finance 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | ₹1.6 Cr+₹2.5 L (1.60%) | L2 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
| 3 | L3₹1.6 Cr+₹4.6 L (2.98%)Rejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹1.6 Cr+₹4.6 L (2.98%) | L3 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
| 4 | L4₹1.7 Cr+₹15.4 L (10.1%)Rejected-Finance 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | ₹1.7 Cr+₹15.4 L (10.1%) | L4 | Rejected-Finance QUOTED AMOUNT NOT LOWEST |
Tender Value
₹1.5 Cr
EMD Value
₹2.2 L
Closing Date
25 Oct 2024, 6:00 pmClosed
CWE DELHI CANTT
HQ CWE DELHI CANTT DELHI 110010
SPECIAL REPAIR REPLACEMENT TO BER OCBs VCBs AND OTHER CONNECTED ITEMS INCLUDNG REROUTING OF HT LT CABLES AT BASE HOSPITAL UNDER GE EM BASE HOSPITAL DELHI CANTT 10
2023_MES_623918_3
CWE/D-16/2023-24
Open Tender
Electrical and Maintenance Works
Works
180 days
DELHI CANTT
As per NIT
7 documents required · 7 mandatory
₹1,000
GE EAST DELHI CANTT
₹2.2 L
Yes
11 Dec 2024
28 Sept 2024
26 Oct 2024
28 Sept 2024
25 Oct 2024
12 Oct 2024
Amount
Total Amount of Sch 'A' Sec -I Part - I (Sub station Bldg)
Total amount of Sch 'A Sec -II Part-I (Internal Electric supply works)
Total amount of Sch 'A - Section II' Part-II (Internal Electric supply works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under col of "Pre Priced rate" signifies this fact only.
Cutting existing pipe line of 100 MM dia and making provision of branch connection for 100 MM GI pipe including all specials.
Sub total of Schedule 'A' Section -II Part-II
Total amount of Sch 'A Sec-III Part-I (Internal Water supply and plumbing works)
Total amount of Sch 'A - Section III Part-II (Internal Water supply and plumbing works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under col of "Pre Priced rate" signifies this fact only.
S&F for CP soap dish compete all as specified and directed
S&F for CP health faucet with 1 mtr flexible tube and hook compete all as specified and directed
S&F for CP paper holder fixing to wall with ss screw compete all as specified and directed .
Sub total of Schedule 'A' Section -III Part-II
Total amount of Sch A Sec -IV Part-I (Road/path/hardstandings works)
Total amount of Sch A Sec -V Part-I (Sewage Disposal works)
Total amount of Sch A - Section V Part-II (Sewage Disposal works) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under col of "Pre Priced rate" signifies this fact only.
S & F factory made precast reinforced cement concrete manhole cover (RCC 1:2:4, using 20 mm graded crushed stone aggregate) 100 mm thick (square/rectangular/circular) with and including 8 mm thick round MS bar and placed over manholes at site complete all as specifiedand directed.
S & F factory made precast reinforced cement concrete manhole cover (PCC 1:2:4, using 20 mm graded crushed stone aggregate)of size 90cmX90cmX50 mm thick and height 125 mm for placing manhole cover and fixed at site manholes with cement slurry complete all as specified and as directed.
Sub total of Schedule 'A' Section -V Part-II
Total amount of Sch 'A Sec- VI Part-I (External Electric supply works works)
Total amount of Sch 'A - Section VI Part-II (External Electric supply works Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under col of "Pre Priced rate" signifies this fact only.
Supply , installation, testing and commissioning of indoor type vacuum circuit breaker panels consisting of incomer VCBs, (As per SLD) with posibility of future extension at one side, the new VCBs as mentioned above should couple with exesting OLD /New VCBs with necessary coupling arrangements all as recommended manufacturer as per site requirment . The capacity of VCB panel should be 11 KV, 1250 Amp, 3 Phase, 3 wire, 50 Hz, having a rupturing capacity of 350 MVA at 11 KV , 26.3 KA breaking capacity for 3 sec, totally enclosed with extended Aluminium bus bar of 1250 Amps for each phase, metal clad, Indoor extensible type , flush front, Horizontal isolation, Horizontal drawout type with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assambly of 3 vaccum interrupters, (Make ABB/Schneider/siemens) with each pole individually encapsulated by epoxy insulations to make it dust proof and self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks (for insertion and removing of VCB), manual and automatic motor charged independent closing/ tripping spring , trip free operating mechanism with closing and tripping push buttons and mechanical breaker ,interconnected with HT sleeve (PVC not accepted) bus bar ,including all protection, indication, Operation, monitoring and control and accessories as per the specification.
Necessary factory inspection shall be arranged before dispatch VCBs . The testing officer shall be nominated by accepting officer after written confirmation received from contractor for VCB panel is ready for testing with all respect as per CA provision. All testing and inspection shall be carried out in presence of testing officer detiled by accepting officer. The joint inspection report shall be submitted after completion of testing. All expenditure in this respect should be bore by contractor and inclusive in quoted rate. No other charges admissible to contractor in this respect after ward.
Supply , installation, testing and commissioning of indoor type vacuum circuit breaker panels consisting of (as per SLD) at NEW POWER HOUSE with posibility of future extension at one side the new VCBs as mentioned above should couple with exesting OLD /New VCBs with necessary coupling arrangements all as recommended manufacturer as per site requirment ,capacity 11 KV, 1250 Amp, 3 Phase, 3 wire, 50 Hz, having a rupturing capacity of 350 MVA at 11 KV , 26.3 KA breaking capacity for 3 sec, totally enclosed with extended Aluminium bus bar of 1250 Amps for each phase, metal clad, Indoor extensible type , flush front, Horizontal isolation, Horizontal drawout type with Electrical and Mechanical interlock and automatic safety shutter gear including padlocking arrangement, isolation plugs, assambly of 3 vaccum interrupters, (Make-ABB/schneider/siemens) with each pole individually encapsulated by epoxy insulations to make it dust proof and self - aligning finger type isolating contacts, truck having integral racking with necessary interlocks (for insertion and removing of VCB), manual and automatic motor charged independent closing/ tripping spring , trip free operating mechanism with closing and tripping push buttons and mechanical breaker ,interconnected with HT sleeve (PVC not accepted) bus bar ,including all protection, indication, Operation, monitoring and control and accessories as per the specification.
- VCB 1250 Amps for Incomers, Buscouper & Outgoing. VI of VCB should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. Basic Insulation level of complete switchgear shall be 28KV/75KV peak. - Closing & tripping coil of VCB should be of continious rating to achive minimal failure. - Resin Cast type CT having Ratio : 100 -50 / 1-1 A, Core1: 5P20, 5 VA; Core 2: 0.5, 5 VA (for Incomer & Outgoing) or as per site requirement during drawing approval stage - Numerical relay having protections of Over Current & Earth Fault (50,51, 50N,51N) with RS 485 port for remote monitoring. - Multifunction Meter of Acc Class 0.5, having facility to see KW, KVA, KVAR, PF, KWH, KVARH, KVAH, A,V etc - Master trip relay - Trip circuit supervision relay (can be feature of numerical relay) - LR & TNC switch, Space heater etc - indication lamp - CB ON/OFF, spring charge, Auto trip, TCS healthy etc. - Transformer Outgoing feeder should have OTI, WTI, Buchloz Alarm & Trip scheme. - Complete panel should be type tested design for Internal Arc 26.3 KA for 0.1 sec with AFLR classification. In this regard, Width & depth of Busraiser /adapter should be similar to other outgoing feeder panel. - Panel construction shall be made of 2 mm thick Aluzic and CRCA. - Make of Panel , VCB must be of same for beter life cycle optimization. Type test reports of complete panel to be submitted as per IEC. VCB shuld be mounted on trolley for easy operation.
Necessary factory inspection shall be arranged before dispatch VCBs . The testing officer shall be nominated by accepting officer after written confirmation received from contractor for VCB panel is ready for testing with all respect as per CA provision. All testing and inspection shall be carried out in presence of testing officer detiled by accepting officer. The joint inspection report shall be submitted after completion of testing. All expenditure in this respect should be bore by contractor and inclusive in quoted rate. No other charges admissible to contractor in this respect after ward.
Supplying, installing, testing and commissioning of 11kV, 26.3kV, 3 Sec BUSCOUPLER VCB Expandable type Indoor arc flash protected Panel Board with Draw-Out type Vacuum Circuit Breaker HV compartment, rated as per the attachded GA arrangment with main bus bar rated for 1250 Amp, The Panel Board must be , confirming to IEC 62271-200, Internal Arc Classified IAC AFLR (All three Chambers) – 25 kA for 0.1sec, Accessibility Class LSC2B-PM Class, having integral earthing interlocking, arrangement continuous rated Al busbars and droppers, 01nos. Rack-In-Rack-Out Handles. The earth switch, for maintenance purpose and dischage functioning, to be provided in the cubicle and shouldbe an intgral part of the cable chamber alongwith the opertaing handle. The Each HV compartment shall consist of following :- (i) VCB 1250 Amps for Buscouper should be sealed for 30000 operation. VCB operationg mechanism should be of M2 duty for minimum 10000 mechanical operation. Basic Insulation level of complete switchgear shall be 28KV/75KV peak.11kV, Suitable rating as per the attached GA arrangment, 26 KA/3-sec, Draw-Out Vacuum Circuit Breaker as per IEC-62271-100. Vacuum Circuit Breaker having 03nos. motorized spring charging mechanism (230VAC) with integral spring charging handle for manual charging, associated push-buttons, anti-pumping feature, and associated Shunt Trip/Close Coils (24 Volt DC).
Necessary factory inspection shall be arranged before dispatch Buscouplers . The testing officer shall be nominated by accepting officer after written confirmation received from contractor for Buscoupler panel is ready for testing with all respect as per CA provision. All testing and inspection shall be carried out in presence of testing officer detiled by accepting officer. The joint inspection report shall be submitted after completion of testing. All expenditure in this respect should be bore by contractor and inclusive in quoted rate. No other charges admissible to contractor in this respect after ward.
Dismantling and shifting of old HT switchgears of any size , capacity and qty from OLD POWER HOUSE at Base Hospital with dismantling of Busbar panels, VCBs, termination Joints , CT & PT and connected accessories and deposted to MES store yard all as specified and directed by Engg-in-charge and
Supply and Laying burn brick size 225 mm X 113 mm X 75 mm etc complete all as specified and directed.
Boring of holes under road, pavement, hard standing by manually with suitable tools including HDPE pipe of 200 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed by Engg -in-charge. Note If any Cable/Pipe Line/Road/Pathway/any tiles will be damaged it shall be repaired by contractor any any extra cost will be pay.
Sub total of Schedule 'A' Section -VI Part-II
RAVINDRA BROTHERS (BID ID -3142061)
BRIJ MOHAN LAL AND CO. (BID ID -3143222)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3137844)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .