Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC KTA ROAD LAMBA LINE JUNGLIGHAT PO PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744103 | ₹2.4 Cr | L1 | Accepted-AOC LOWEST BIDDER |
| 2 | L2₹2.6 Cr+₹27.5 L (11.6%)Rejected-AOC V P O SAROTARI TEHSIL BAROH DISTRICT KANGRA PIN 176037 HP | KANGRA | HIMACHAL PRADESH | 176037 | ₹2.6 Cr+₹27.5 L (11.6%) | L2 | Rejected-AOC NOT BEING LOWEST |
| 3 | L3₹3.0 Cr+₹59.5 L (25.1%)Rejected-AOC 2ND FLOOR 9 EZRA STREET KOLKATA WEST BENGAL 700001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹3.0 Cr+₹59.5 L (25.1%) | L3 | Rejected-AOC NOT BEING LOWEST |
Tender Value
Refer Docs
EMD Value
₹3.3 L
Closing Date
14 May 2025, 6:00 pmClosed
COL MANOJ NEGI
CWE AF NORTH BANGALORE BELLARY ROAD JC NAGAR POST
PROVISION OF STP FOR AUGMENTATION OF WATER SUPPLY FROM BWSSB TO ASTE TECH AREA UNDER GE (AF) MARATHAHALLI
2024_MES_680589_2
87559CWEAFNMAR
Open Tender
Civil Works
Lump-sum
3900 days
GE (AF) MARATHAHALLI
AS PER NIT
7 documents required · 7 mandatory
₹2,000
GE (AF) MARATHAHALLI
₹3.3 L
Yes
28 Jul 2025
16 Apr 2025
17 May 2025
17 Apr 2025
14 May 2025
30 Apr 2025
17 Apr 2025 - 25 Apr 2025
GENERAL SUMMARY NOTE: (a) Schedule ‘A’ Part I-B, II to IX are prepriced by MES under Ser No. 2 to 10. Bidders shall insert their lumpsum amount in the Green coloured field under Col-6 only. (b) Schedule 'A' Part I-A & Part- X are not priced by MES & prepriced rates indicating 0.00 under column 5 signifies this fact only, Bidders shall insert their rates amount in the Green coloured field under Col-6
SCH A PART I-A SEWAGE TREATMENT PLANT AND STP ROOM Design and construction, supply, installation, Testing & Commissioning of package type Eco Type SBR Technology fully Avanced Automatic Sewage Treatment plant of capacity 50 KLD with Tertiary Treatment with following accessories mentioned herein after :- (a) ESBR loT controller : 1 unit EcoTec Proprietary Control unit with microproccessor control with intranet web access, pre-set works cycles,real- time controlled, graphic display operating hours' counter,optional manual and automatic mode, acknowledgeable visual and acoustic fault message, mains failure alarm function operating levels. (b) Panel Board enclouser: 1 Unit Panel board(Class IP 65) for the enclosure of controller and necessary electrical equipment's(phase failure relay MPCB contractor). (c) Side channel blower/ compressor : 1 Unit Side channel blower / Vane Compressor - 4.0 KW 3 Phase. (d) Diffusers in aeration tank - EPDM Fine bubble Tubular diffusers - 12 to 16 Nos (1m Tubular Diffusers) with SOTE <8.5%/m at a flow rate of 5 cu.m/hr or equivalent.
(e) Diffusers stands Diffusion system in SS 304(8/6 out put)m stands, As per requirement and as per the tank dimension. (f) Air hose, PVC braided from polyhose at 10 Kg / Sqcm temperature rating of 85 deg C (Appx 150 m (Machine room <3m from aeration tank) (g) Airlift unit for transfer of water in collection aeration and treated water tank Air lift arrangement and functional mechanism : minimum – 5/6 unit or as requirement at site Charging unit by air lift : 2 unit Discharge unit by air lift : 2 unit Sludge return unit by air lift : 2 unit (h) Wiring for plant As per requirement in the site (j) SS 304 pipe clamps Clamps and fitting for wall mounting of SS 304 ( As per requirement at site) (k) Component for assembling and fixing solenoid valve set. Solenoid valve for air lift arrangement(Asco(1") : 4 unit Valve stand for valves(SS 304,2 mm thickness : 1 unit EcoTec Operation Manual & Maintenance Manual : 1 No (l) Filtration system - 1 lot Note :- NOC and water testing report from State pollution board. Automatic filtration system AMPV, Starter panel (automatic multiport valve) + PSF + ACF + Filter feed pump (1W + 1S) with a flow rate 1-3 cum / hr
Lumpsum price worked out by the contractor for “Building Work” as listed in Schedule ‘A’ Part - I-B.
Lumpsum price worked out by the contractor for “Site clearance” as listed in Schedule ‘A’ Part - II.
Lumpsum price worked out by the contractor for “Internal Water Supply” as listed in Schedule ‘A’ Part–III
Lumpsum price worked out by the contractor for “Internal Electric work” as listed in Schedule ‘A’ Part–IV
Lumpsum price worked out by the contractor for “Path / Culverts” as listed in Schedule ‘A’ Part - V
Lumpsum price worked out by the contractor for “Sewage Disposal" as listed in Schedule ‘A’ Part–VI
Lumpsum price worked out by the contractor for “Area Drainage” as listed in Schedule ‘A’ Part - VII.
Lumpsum price worked out by the contractor for “External Water Supply" as listed in Schedule ‘A’ Part - VIII .
Lumpsum price worked out by the contractor for “External Electrification” as listed in Schedule ‘A’ Part – IX.
Sch A Part X - MISCELLANEOUS : Supply and lay pipe ductile Iron , S/S including specials, Class “K-9” ,100 mm (4”) dia complete all as specified and as directed.
Supply and fix Foot Valve with strainer conforming to IS 4038, 100 mm (4") dia complete all as specified and as directed.
Supply and fixing Pumping sets, centrifugal, electric driven, supply and Install complete up to 10 HP inclusive of starter and PCC foundation complete all as specified and as directed
M & L for Ductile iron fitting upto 100 mm dia for DI socketed fittings as Bends,Tee pieces collars, caps and plugs complete all as specified and as directed.
M & L for Construction of brick masonry valves pits, of the following internal dimension complete with 3.15 mm thick MS sheet cover angle iron frame duly painted with locking arrangement including all necessary excavation and earth work PCC work complete.
(a) 900 mm x 900 mm x 900 mm
(b) 600 mm x 600 mm x 600 mm
Supply, insallation, Testing and commissioning of filtered water supply pumps1 HP capacity for Arboriculture Head range 16-32 m flow range 1.7-0.4 LPS
Supply, insallation, Testing and commissioning of Non clog vertical submersible pump of 1 HP with crome steel impeller and cutter , non clog to pass 40 mm size particals (Duty Flow head lpm X m 75X25)including supply , installation with guide rail and lifting chain cables, earthing, testing complete with 2 years maintenance
Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1200mm x 1200mm x 400mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item.
Supply ,fabrication, installation and testing of LT Panel out door type factory made CPRI Approved, water and vermin proof protection of size 1200mm x 1200mm x 400mm (over all dimension) made out of 3.00 mm thick CRCA sheet dully supported with mild steel angle iron of size 40X40X5mm vertical frame and legs with mild steel flat iron 25 x 5 mm in horizontal sides of the frame with front and back side openable ,single hinged door / shutter with locking arrengement and powder coated finish both internal and external steel surfaces after necessary preparation of steel surfaces including providing PCC (1:3:6) type C2 foundation of suitable size and connections of all outgoing / incomming cable inclusive of necessary excavation and earthwork as required including the following fitment accessories all complete as specified and as directed. NOTE: Rate of earthwork and PCC work are deemed to be inclusive in this item.
OUTGOING (a) MCCB, adjustable thermal magnetic release type, 4 poles, 415 Volts, Ics = 100% Icu, 25 KA breaking capacity, rating 63 Amps including all fixing accessories with both ends spreader links -02 Nos (b) Supply and fixing MCB TPN 32 amps 10 KA, C-series including connection complete all as specified and directed.- 02 Nos (c) Multifunctional Digial type timer Switch 240 volts AC Single Phase - 01 No (d) Power contractor 32 amps 3 Pole 415 Volts AC - 01 No (e) Enamelled iron danger notice plate of 1.60 mm thick mild steel sheet of size 200 mm X 150mm , white with letters , figures and conventional skull and bones in signal red and fixed with nuts and bolts on door / shutter for LT -01 No.
Manning and operation of complete sewage treatment plant of capacity 50 KLD operation in and including normal maintance of pump sets and cleaning of pump house premises complete all as specified and directed. (for 1st year) after physical completion of Phase-I. No of shifts : Three shifts per day No of labours : one FGM (Semi-Skilled) for each shift including reliever. (Shift timing 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs)
Manning and operation of complete sewage treatment plant of capacity 50 KLD operation in and including normal maintance of pump sets and cleaning of pump house premises complete all as specified and directed. (for 2nd year) after physical completion of Phase-I. No of shifts : Three shifts per day No of labours : one FGM (Semi-Skilled) for each shift including reliever. (Shift timing 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs)
Manning and operation of complete sewage treatment plant of capacity 50 KLD operation in and including normal maintance of pump sets and cleaning of pump house premises complete all as specified and directed. (for 3rd year) after physical completion of Phase-I. No of shifts : Three shifts per day No of labours : one FGM (Semi-Skilled) for each shift including reliever. (Shift timing 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs)
Manning and operation of complete sewage treatment plant of capacity 50 KLD operation in and including normal maintance of pump sets and cleaning of pump house premises complete all as specified and directed. (for 4th year) after physical completion of Phase-I. No of shifts : Three shifts per day No of labours : one FGM (Semi-Skilled) for each shift including reliever. (Shift timing 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs)
Manning and operation of complete sewage treatment plant of capacity 50 KLD operation in and including normal maintance of pump sets and cleaning of pump house premises complete all as specified and directed. (for 5th year) after physical completion of Phase-I. No of shifts : Three shifts per day No of labours : one FGM (Semi-Skilled) for each shift including reliever. (Shift timing 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs)
Manning and operation of complete sewage treatment plant of capacity 50 KLD operation in and including normal maintance of pump sets and cleaning of pump house premises complete all as specified and directed. (for 6th year) after physical completion of Phase-I. No of shifts : Three shifts per day No of labours : one FGM (Semi-Skilled) for each shift including reliever. (Shift timing 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs)
Manning and operation of complete sewage treatment plant of capacity 50 KLD operation in and including normal maintance of pump sets and cleaning of pump house premises complete all as specified and directed. (for 7th year) after physical completion of Phase-I. No of shifts : Three shifts per day No of labours : one FGM (Semi-Skilled) for each shift including reliever. (Shift timing 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs)
Manning and operation of complete sewage treatment plant of capacity 50 KLD operation in and including normal maintance of pump sets and cleaning of pump house premises complete all as specified and directed. (for 8th year) after physical completion of Phase-I. No of shifts : Three shifts per day No of labours : one FGM (Semi-Skilled) for each shift including reliever. (Shift timing 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs)
Manning and operation of complete sewage treatment plant of capacity 50 KLD operation in and including normal maintance of pump sets and cleaning of pump house premises complete all as specified and directed. (for 9th year) after physical completion of Phase-I. No of shifts : Three shifts per day No of labours : one FGM (Semi-Skilled) for each shift including reliever. (Shift timing 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs)
Manning and operation of complete sewage treatment plant of capacity 50 KLD operation in and including normal maintance of pump sets and cleaning of pump house premises complete all as specified and directed. (for 10th year) after physical completion of Phase-I. No of shifts : Three shifts per day No of labours : one FGM (Semi-Skilled) for each shift including reliever. (Shift timing 0600 Hrs to 1400 Hrs, 1400 Hrs to 2200 Hrs and 2200 Hrs to 0600 Hrs) Notes for item No 20 to item No 29 : The following equipment are to be operational / functional which are installed in 50 KLD capacity sewage tertiory treatment plant. (a) Consist of : Coarse Bar Screening Chamber (RCC), Receiving sump Silting chamber, Fine bar screen chamber, Oil & Grease remover, Grit seperator, Equalisation tanks, Air grid for equalisation tank, Feed pumps, Eco type SBR Technology, Air blowers, Tube settler assembly, sludge pump, sludge dewatering pump, sludge holding tank, air grind, chlorine dozing system & filter feed tank & pumps, dual media filter, activated carbon filter, treated water tank with irrigation, arboriculture, fire fighting system etc.. (b) DG Set of cap 200 KVA with control panel (c) LT Panel board with starter and valves
Note : As applicable :- (a) The oprating staff shall be capable for attending minor defects/ rectification. Necessary tools should be provided by the contractor with out any extra cost. (b) DHPP (Diesel) shall be issued by department by using DG Operators but diesel should be collected from AFS (MT)/ MES (MT). (c) The operating staff shall record the voltage the voltages & amperes, consumption of diesel and readings etc., in the daily log sheet as per format enclosed as Appendix 'A' as applicable. (d) The operating staff shall record the pump set No, Running hours, qty of water pumped, voltages & Amperes in the daily log sheet as per format enclosed as Appendix 'B' as applicable. (e) The rate quoted is inclusive of supplying required daily log sheet and stationary as required without any extra cost. (f) The unit rate quoted shall be deemed for carrying out daily maintenance of installation (as mentioned in BOQ & particulars specification), buildings and surroundings of the buildings including cleaning and removing all vegetation all around the installation upto 3 mtrs from the plinth protection complete. (g) No RAR shall be admitted for payment if wage and attendance register of Trades personnel engaged duly verified by Engr-in-Charge are not produced alongwith RAR/FB. (h) No RAR shall be admitted for payment if copy of payment proof made through Adhar linked Bank Accounts of Trades personnel engaged by the contractor duly verified by the Engineer-in-Charge are not submitted. (i) The unit rate quoted shall be deemed to be inclusive of EPF, over head charges, GST and LWC etc as applicable.
Electromech Engineers (BID ID -3296494)
surendra infrastructure pvt ltd (BID ID -3296930)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .