| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹7.7 LAccepted-AOC AT SUBHASH NAGAR BESIDE QTR NO CHB 22 P O RAY JHARKHAND PIN 829209 | RAY | RANCHI | JHARKHAND | 829209 | L-1 | Accepted-AOC Installation and commissioning of Lattice Mast communication tower | |
| 2 | L-2₹6.7 L+₹18,600.35 (2.84%)Rejected-Finance AT BACHRA P O BACHRA P S PIPARWAR BACHRA 829201 | BACHRA | CHATRA | JHARKHAND | 829201 | L-2 | Rejected-Finance As per Recommendation of TC and Approval of Competent Authority | |
| 3 | L-3₹6.9 L+₹37,225.50 (5.68%)Rejected-Finance AT DAKRA P O DAKRA DISTT RANCHI JHARKHAND PIN 829210 | DAKRA | RANCHI | JHARKHAND | 829210 | L-3 | Rejected-Finance As per Recommendation of TC and Approval of Competent Authority |
Tender Value
₹7.7 L
EMD Value
₹9,680
Closing Date
27 Dec 2023, 5:00 pmClosed
Staff Officer (EnM),M-S Area
Office of the General Manager M-S Area
Installation and commissioning of Lattice Mast communication tower and providing network communication for live steaming at different weigh bridges and central control room, Chamatu under Magadh OCP, M-S Area
2023_CCL_296325_1
GM(MS)/SO(EnM)/e-NIT/23-24/145
Open Tender
Electrical and Maintenance Works
Item Rate
15 days
Office of the Project Officer M-S Area, Bachra
Please Refer NIT
4 documents required · 4 mandatory
₹9,680
2 Sept 2024
18 Dec 2023
28 Dec 2023
18 Dec 2023
27 Dec 2023
18 Dec 2023
18 Dec 2023 - 25 Dec 2023
Amount
Category : 6 UTP Out Door Solid copper cable Conductor : Conductor : 23 AWG (Solid)Conductor Meta : Conductor Meta : Bare Copper Insulation Material : HD-PE OD : 6.1mm ±0.2 Resistance Unbalance : 5% Max Capacitance Unbalance : 330pF / 100m Delay Skew : <45nS
Cat6 patch cord , 3Mtr length .
Single mode optical fiber cable 6F,HFRR Jacket with Attenuation before cladding less than 0.20 dB/km after cladding 0.22db/km, Zero Dispersion Wavelength 1300 to 1324 nm, zero dispersion slope ≤0.092 PS/nm2 km, PMD (Polarization Mode Dispersion) ≤0.2 PS/√km, Cable Cut-off Wavelength (λcc) ≤1260 nm, Macro bending Loss (100 turns; Ф50 mm) @1550 nm ≤ 0.05 db. Cladding Diameter 125 ±1μm And Proof stress ≥0.69Gpa
Ethernet Gigabit Media Converter, Pure Networking Copper to Fiber Media Converter - 10/100/1000BASE-TX to 1000BASE-LX Singlemode SC, 1310-nm, up to 20-km, (1) RJ-45; (1) pair of SC, MEDIA SUPPORTED CATx UTP/STP; Single-mode fiber (8.3/125 µm, 9/125 µm, 10/125 µm) DISTANCE CATx: 328 ft. (100 m), SM fiber: 12.4 mi. (20 km),
Fiber patch cord SC-SC single mode 2 metér simplex , suitable for data communication, and telecommunication applications. with terminated oonnectors ih 6ssemblies are designed to and are compatible with iřidustry standards (EIATIA, IEC, ANSI, NTT and Telcordia
Splice closure for OFC Cable
9U Network rack Rack Enclosure , Material used CRCA Steel for outdoor fixing at Tower
Supply of 2.5 sqmm 2 core flexible copper cable
Splicing/ jointing of Fiber Optic Cables with Splice loss of fiber with MFD 9.3um with fiber of range 8.8~9.6um, Core-Clad Concentricity in today’s G.652 single mode fibers is <0.5um.and offset is in opposite directions (total 1um offset), the contributed loss will be 0.056dB.
Self supported Lattiees mast/communication tower 18 Meters (60 feet) ,Triangular Latticed Aerial Mast,Number of Sections 6 for 60 feet Mast, Wind speed 0-120 KM/H, Material GI Pipe, Minimum yield strength, Three support legs ,Hot dipped Galvanized.
Dismantling of Latice Mast Communication Tower 18 mtr
Installation of Latice Mast Communication Tower 18 mtr
Foundation for latties mast/ communication tower providing and |laying in position reinforced cement concrete 1:2:4 (I cement: 2 Coarse: 4 stone aggregate 20mm nominal size) in foundation of pumps. Dg set etc, including form work etc ,as required (excluding reinforcement (4 X 1.75 cum)
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required
Wiring for circuit/ submain wiring alongwith earth wire with thefollowing sizes of FRLS PVC insulated copper conductor,single core cable in surface/ recessed medium class PVCconduit as required 2 X 1.5 sq. mm + 1 X 1.5.5 sq. mm earth wire
Erection / commissioning charge @ 15% on item no.1 to 8
Total impact of GST for the purpose of CTC
M/S ASHOK ENTERPRISES
M/S MEHTA ELECTRONICS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_306907.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .