RequiredOEM Authorization Certificate Bid to RA enabled No Electronic Total Station ( 3 pieces ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Bid Requirement (Allowed Values) ANGULAR MEASUREMENT Angle Measurement Accuracy 5 0.5
Required1
Required1.5
Required2
Required3
Required4
Required5
Required0.2 Or lower Method Absolute * Display resolution Least Count 1 0.05
Required0.1
Required0.15
Required0.2
Required0.25
Required0.3
Required0.5
Required0.6
Required0.7
Required0.8
Required0.9
Required1 Or lower Compensation Dual Axis Dual Axis Compensator Setting Accuracy 1 0.5
Required1 Or lower 1/5 DISTANCE MEASUREMENT Distance Measurement with Reflector Prism with Single Prism 4000 4000
Required4500
Required5000
Required5500
Required6000 Or higher Accuracy in Distance Measurement with Reflector Prism <= (2.0 mm + 2 ppm) * Distance Measurement without Reflector Prism 500 500
Required600 Or higher Accuracy in Distance Measurement without Reflector Prism upto 250m <= (4 mm + 2 ppm) * Typical Measurement time 0.9 0.1 - 0.9 Or lower TELESCOPE Image Type Erect * Magnification ( X ) 30 * Resolving power 2.5 0.0 - 2.5 Or lower Field of View @ 1000 meter 26 * Minimum Focus Distance 1.3 0.0 - 1.3 Or lower Reticle illuminated
Required10 brightness level * PLUMMET Plummet Type Optical Optical Optical Plummet Magnification 3X * Laser Plummet Centering accuracy @ 1
Required5 mtr instrument height 1 * DATA STORAGE INTERFACE KEYBOARD AND DISPLAY Storage Capacity ( in terms of number of measurement entries ) 50000 * Data storage- Internal Memory 0.5 0.5
Required1
Required2
Required3
Required4
Required8 Or higher External Storage Type USB Drive * Data Downloading Facility through Interface USB Cable * Alphanumeric Keyboard and Touchscreen Display on both sides Yes * Display Features Day light * 2/5 readable
RequiredDisplay Illumi nation
RequiredQVGA
RequiredVGA
RequiredWVG A SOFTWARE CHARACTERSTICS Operating System Linux Based Linux Based Data formats support CSV * Auto Power-Off Option No * Onboard Software Functions Survey & Coding with Lineworks
RequiredCross Section
RequiredReference Plane
RequiredTraverse
RequiredSets of Angles Determine Coordinate Systems
Requiredcogo
RequiredRemote Heights
RequiredReference Line/Arc
RequiredHidden Point Offset
RequiredStakeout * Onboard Application Software for processing the field data and Creating the field report yes * PHYSICAL CHARACTERSTICS Ingress Protection IP 66 * Weight 5.1 * Dimensions ( mm x mm x mm ) - * Vertical Tilt Sensor monitors the tilt angle in x-axis yes * Vertical angle measuring provides three different options plus percentage of grade yes * Removable tribrach for multiple set-ups yes * Guide Light (EGL) Working Range (average atmospheric conditions) 5m to 50m * Guide Light (EGL)- Positioning accuracy @ 100 m 0 * Capability to track the location of instrument (GPS) No No Additional features
Requiredif any - * OPERATING CONDITIONS Minimum Operating Temprature -20 * 3/5 Maximum Operating Temprature 60 * Non Condensing Humidity ( Rh) ( % ) 80 * POWER SUPPLY Power Source Rechargeable Batteries * Noumber of Rechargeable Batteries 1 * Number of Extra Rechargeable Batteries 1 * Chemistry of Rechargeable Battery Li-ion * Capacity of Rechargeable Battery 2430 * Voltage of Rechargeable Battery ( DC ) 7.2 * Battery Operating time (Backup Time) 16 16
Required20
Required24
Required30 Or higher Recharge time 3 * Suitable Battery Charger/Adapter working on 230V AC ±10%; 50 Hz ±10% yes * WARRANTY Warranty 1 1
Required2
Required3
Required4
Required5
Required6 Or higher ACCESSORIES Software for Transfering Data to PC yes * Instruction Manual yes * Data Transfer Cable yes * SD Card/USB Pen Drive of Size 8 * Number of Tripod 1 * Type of Tripod Available Wooden
RequiredPlastic
RequiredMetallic * Number of Detachable Tribrach 1 * Number of Single prism with Target Plate 2 * Number of Range Pole 1 * Lens cover set yes' * Shock absorbing carrying case with shoulder strap yes * Instrument height meter No * 4/5 CERTIFICATION AND TESTING Type approval and calibration from NABL/ILAC/Govt Laboratory No * Type Test Certificate number and Date - * Name and Address of Lab - * * Bold specifications are the golden parameters. * Bidders may note that In respect of non-golden Parameters
Requiredthe specifications 'Values' chosen by Buyer will generally be preferred over 'Bid requirement ( allowed Values) by the Buyer.