Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.9 LAccepted-AOC A 47D RAM DUTT ENCLAVE UTTAM NAGAR NEW DELHI 110059 | WEST | DELHI | 110059 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹32.0 L+₹1.1 L (3.71%)Rejected-Finance N A | NA | NA | 121004 | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹32.7 L+₹1.8 L (5.92%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹34.5 L+₹3.6 L (11.6%)Rejected-Finance 1 204 LOWER GROUND FLOOR SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹42.1 L+₹11.2 L (36.4%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
| Sl No | Description | Qty | Unit | Gaurav Construction Company L3 | Akhil Enterprises L1 | M/S GEETANJALI ENTERPRISES L5 | Gaurav India Corporations L2 | LAXMI GROUP L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including cutting reinforcement required to facilitate demolition upto and including fourth story and on the roof top/mumty/parapet and removal of debris and rubbish out side MoD land complete all as specified and directed. | 1 | Cum | 260 ₹260 | 577 ₹577 | 200 ₹200 | 50 ₹50 Lowest | 100 ₹100 |
| 2.00 | Demolition of brick work or Stone/Boulder mesoning built in cement mortar in any description and position complete all as specified and directed. | 42.35 | Cum | 260 ₹11,011 | 177 ₹7,495.95 | 200 ₹8,470 | 50 ₹2,117.5 Lowest | 100 ₹4,235 |
| 3.00 | Demolition of cement concrete (un-reinforced) in Ground floors and paving not exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specified and directed. | 103.4 | Cum | 260 ₹26,884 | 77 ₹7,961.8 Lowest | 200 ₹20,680 | 80 ₹8,272 | 100 ₹10,340 |
| 4.00 | Taking down asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings, complete all as specified and directed | 90 | Sqm | 26 ₹2,340 | 7 ₹630 Lowest | 10 ₹900 | 15 ₹1,350 | 40 ₹3,600 |
| 5.00 | Dismantling steel truss of span more than 6.00m but not exc 10m embedded in Concrete, brick work, masonry, etc. any section, including taking out embedded portion and making good disturbed ground. | 5 | Each | 960 ₹4,800 | 477 ₹2,385 | 500 ₹2,500 | 280 ₹1,400 | 100 ₹500 Lowest |
| 6.00 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. | 12 | Qtl | 260 ₹3,120 | 477 ₹5,724 | 500 ₹6,000 | 100 ₹1,200 Lowest | 600 ₹7,200 |
| 7.00 | Taking down chowkhat or frames exc. 1.5 Sqm and not exc 4 Sqm each with shutters (without taking off shutters from frames) complete all as specified and directed. | 1 | Each | 160 ₹160 | 77 ₹77 | 100 ₹100 | 50 ₹50 Lowest | 100 ₹100 |
| 8.00 | Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/ loose soil. complete all as specified and directed. | 19.5 | Cum | 160 ₹3,120 | 177 ₹3,451.5 | 150 ₹2,925 | 100 ₹1,950 Lowest | 200 ₹3,900 |
| 9.00 | M&L for PCC (1:4:8) Type D-2 (using 40mm graded stone aggregate) as foundation filling in mass concrete, complete all as specified and directed. | 4 | Cum | 2,600 ₹10,400 | 2,877 ₹11,508 | 3,000 ₹12,000 | 3,650 ₹14,600 | 2,000 ₹8,000 Lowest |
| 10.00 | Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed. | 27 | Sqm | 206 ₹5,562 | 177 ₹4,779 | 250 ₹6,750 | 50 ₹1,350 Lowest | 300 ₹8,100 |
Tender Value
₹42.9 L
EMD Value
₹85,845
Closing Date
22 Oct 2025, 6:00 pmClosed
GE (EAST) DELHI CANTT-10
GE (EAST) DELHI CANTT-10
ADDN/ ALTN TO GUARD ROOM AT GATE NO 3, SPL REPAIR TO 17 PLINTH AT FLAG AREA, REPLACEMENT OF VARANDAH OVERHEAD STRUCTURE WITH STEEL TRUSS AND GALVALUME SHEETING AT MULTI UTILITY HALL AND ADDN/ ALTN TO EXISTING SHED FOR STORE INSIDE AT DGNCC UNDER GE (
2025_MES_732472_1
GE/DE-98/2025-26
Open Tender
Civil Works
Item Rate
120 days
GE (EAST) DELHI CANTT-10
Class D/ Cat a (i)
9 documents required · 9 mandatory
₹500
Yes
GE (EAST) DELHI CANTT-10
₹85,845
Yes
3 Dec 2025
24 Sept 2025
24 Oct 2025
24 Sept 2025
22 Oct 2025
8 Oct 2025
Amount
Demolition of cement concrete (reinforced) of any position not otherwise specifically provided for and including cutting reinforcement required to facilitate demolition upto and including fourth story and on the roof top/mumty/parapet and removal of debris and rubbish out side MoD land complete all as specified and directed.
Demolition of brick work or Stone/Boulder mesoning built in cement mortar in any description and position complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in Ground floors and paving not exe 15cm thickness ( below or above ground level ) including removal of rubbish out side complex (MOD land), complete all as specified and directed.
Taking down asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings, complete all as specified and directed
Dismantling steel truss of span more than 6.00m but not exc 10m embedded in Concrete, brick work, masonry, etc. any section, including taking out embedded portion and making good disturbed ground.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Taking down chowkhat or frames exc. 1.5 Sqm and not exc 4 Sqm each with shutters (without taking off shutters from frames) complete all as specified and directed.
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and not exc 1.5 m in depth and getting out in soft/ loose soil. complete all as specified and directed.
M&L for PCC (1:4:8) Type D-2 (using 40mm graded stone aggregate) as foundation filling in mass concrete, complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions, complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam hunching, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick, complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but not exc 20cm wide, complete all as specified and directed.
M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed.
Description all as per item No 15 above but 8mm dia as in stirrups.
M&L for reinforced cement concrete M-25 (Design mix) as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc. all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) as in Columns, pillars, piers, posts and struts etc. all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) as in Beams, cantilevers, bressummers, lintels over 1.5m span etc. all as specified and directed.
M&L for reinforced cement concrete M-25 (Design mix) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, chhajja,deck slabs and in shelves and the like etc. all as specified and directed.
Providing and applying the plaster with single component ready to use Polymer modified repair mortar capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat : SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area including taking down existing roof treatment of any type with cement plaster on brick/concrete surfaces, including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified and as directed. Make: Smart Care (Asian Paints) or equivalent in Sika/ Fosroc/ Berger/ STP. Note : The application shall be executed on any type of surface and on horizontal/Vertical areas.
Providing and applying Smart care Damp proof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajjas in multiple coats @2.0 litre/sqm. Primary coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge. (Make: Smart Care Damp Proof of Asian Paints or equivalent in Berger/ Nerolac). Notes:(1) The work shall be executed through authorised applicator of manufacturer only. (2) Authorised Applicator shall be approved by GE before starting of work. (3) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material. Engineer-in-Charge shall deface the original purchase vouchers. (4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water proofing treatment for a period of Eight years in favour of the GE. A sum equivalent to 2.5% (Two point Five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor’s dues as security deposit. The contractor may, however, furnish a fixed deposit receipt in lieu from a Schedule bank pledged in favour of Garrison Engineer.
M&L for Brick work with sub class 'B' bricks of old size, straight or curved on plan to any radius built in CM 1:6 complete all as specified and directed.
Returning filling in incl spreading levelling watering and well ramming in layers not exceeding 25cm in soft or loose soil complete all as specified and as directed.
Removing excavated materials to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils complete all as specified and as directed.
M&L for 40mm thick PCC (1:2:4) Type B-0 using 12.5mm graded stone aggregate as damp proof course and applying Polythene film, 50 micron thick, laid on a coat of bitumen primer, @ 0.30 to 0.50kg per sq. m , complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed.
M&L for 75mm thick plain cement concrete Type C- 2, 1:3:6 (using 40mm graded stone aggregate) as in sub base complete all as specified.
M&L for hard-core of broken bricks of gauge not exc. 63 mm, deposited, spread and levelled in layers not exc. 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
M & L for glazed ceramic tiles in vertical surface of size 300mmx600mm and 7-8 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over & incl 10mm thick rendering/ backing coat in CM 1:4 complete all as specified and as directed.
M & L for Vitrified coloured tiles any shade 8-10mm thick (square/rectangular) polished, area of each tile not exceeding 0.36 sqm each in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6, complete all as specified and as directed.
M & L for 16 to 18 mm thick granite (Z-black colour or any superior quality/colour as approved by GE) table rubbed and polished in floor, steps, jambs, pillars, window cills, cooking platforms, floor , steps, serving counters etc. and like over and including 15mm thick cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite slab , notching, moulding and diamond polishing, complete all as specified and as directed .
M&L Rendering 15 mm thick in cement mortar 1:4 on fair face of brick work/ concrete surfaces with water proofing admixture finished even and smooth without using extra cement incl scaffloding, complete all as specified and directed.
M&L Rendering 5mm thick in cement mortar 1:3 as in ceiling finished even and smooth without using extra cement to match with existing surface complete all as specified and directed.
M&L Rendering 15 mm thick in cement mortar 1:6 on fair face of brick work/ concrete surface, finished even and smooth without using extra cement complete all as specified and directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of 35mm size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, including 3 Nos stainless steel butt hinges of size 100mm, 2 Nos 150mm long stainless steel tower bolt and 01 No 250mm long sliding bolt of all as per direction of Engineer-In-Charge. Make 'Rajshree or equivalent "
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/Ceosetory windows & other Frames/Chowkhat of size 65x 125 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Make 'Rajshree or equivalent "
Description all as per item No 36 above but wire mesh door shutter all as per specification.
S&F for Box type steel window made of 1.25mm thick ERW tube P- Section of size 60x25mm double rebated outer frame comprise of gauzed skeleton shutter (two gauged shutters and two glazed of ERW tube P- section size 50 X 20 mm and 1mm thick, one/two numbers Openable leaf consisting of two number sash bar of T- section 20mm X 30mm welded to frame with one number vertical mullion of ERW box type T- section of size 60X25 mm and 1.25 mm thick and FI 2 mm thick welded/ screwed to frame for fixing of glass incl fittings and fixture like handle, Tower bolts, stopper, cleat pintail hinges, hold fast etc. (a) Holdfast 150mm long of FI 120mmx 3mm made to shape 04 Nos per window. (b) Handle of Z section 20mmx25mm,100mm long stopper 01 Nos per leaf.(c) MS Tower bolts 150mm long -2 Nos (d) Z section 20mmx25mm, 100mm long stopper 01 Nos per leaf.(e) Cleat 55mm long of hollow square 15mmx20mm x63mm welded hinges 01 No per leaf.(f) MS pintol hings of size 75mmx12mm , 2 Nos per leaf.(g)3mm thick plain glass sheet on shutter outside and 0.5mm thick SS wire mess opening inside including 2 coat of synthetic enamel paint over a coat of primer incl preparation. Note : One unit shutler shall consist both shutter (Glazad & Gauged).
M&L for built in steel cup board of pressed steel frame of size 75 mmx45mmx1.25 mm thick with pressed steel shutter 1mm thick with hinges ,Godrej pattern, fixed to masonry wall by hold fast made out of 25x3 mm flat iron including locking arrangement and two coats of spray painting with synthetic enamel paint over one coat of red oxide primer all around on steel surface of frame & shutter complete all as specified.
M & L for Washed stone grit plaster on exterior walls in two layers (colour and design as approved by GE), under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand ) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3 Kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 cement: 1/2 coarse sand : 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern (groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove) complete including scrubbing and washing, the top layer with brushes and water to expose the stone chippings including taking down of existing cement or cement lime plaster of any thickness and any description on brick or stone walls including raking out joints, hacking for key and scrubbing down with water, complete all as specified and as directed.
M & L for preparation of new or old decorated plaster external wall and ceiling surfaces of and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over and including 2mm thick wall care putty complete all as specified and as directed.
M & L for preparing newly plastered surfaces of wall incl preparation of surfaces and applying two coats of oil bound distemper over a coat of interior primer and 2-3mm wall care putty (JK or Birla) on wall surfaces complete as specified and directed.
Description all as per item no 43 above but on ceiling, complete as specified and directed.
M&L for rubber moulded coloured (Gloss finish) Chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement and pigment as in floors, over and incl 15mm thick screed bed in CM 1:6, complete all as specified and directed.
S & F Precast RCC manhole covers 75 mm thick medium duty conforming to IS-12592, including demolition of existing MH cover of any type complete all as specified and as directed.
Dismantling of kota stone or granite stone slabs and tiles of any description or thickness in floors, aprons, fixed on vertical surface etc. complete all as specified and directed.
M&L for machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing, over and incl 15mm thick screed bed in CM 1:6, complete all as specified and directed.
Description all as per item no 23 here-in-before but except bricks.
M & L for 40mm thick Cement concrete 1:3:6 type C-1 (using 20mm graded agg) as in floor complete all as specified and as directed.
Taking down cement plaster on brick or stone walls ceiling , etc including raking out of joints, hacking for key, scrubbing down with water etc. complete.
Providing PCC (1:2:4) Type B1 as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
M & L for Machine pressed precast concrete interlocking paver block of any shape and size (Two colour combination) conforming to IS 15658-2006 of 60 mm thick, M-35 Grade laid dry in floor/path over and including 50 mm thick sand bedding layer complete all as specified and as directed.
M&L for PCC (1:2:4) type B-2 (using 40mm graded stone aggregate) as in foundation, complete all as specified and directed.
S&F for mild steel bolts with dia of neck 12mm, purpose made with hexagonal or square head one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut. Exc 30cm long. complete all as specified and directed.
S&F for mild steel Plates (plain or chequered) channels, square/ rectangular, cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified and directed.
Dismantling of plain or corrugated sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings, complete all as specified and directed.
Excavating in post holes (or similar holes) each not exec 0.5cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cumin soft/ loose soil. complete all as specified and directed.
M&L for PCC (1:3:6:) Type C2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete, complete all as specified and directed.
M & L for Stainless Steel work of Grade-304 as in vertical post/pole, trusses of any type and size including special shaped washers, channels, plates (horizontal/ vertical/cantilever type work) also ornamental works like designer railing chain, lotto any type and size as approved by GE and as red at site made of hollow tubes or in any other shape as per requirement at site, including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary nuts and bolts dash fasteners, stainless steel bolts etc., of required size on the top of floor or the side of waist slab with suitable arrangement complete all as specified and as directed. (Note :- No extra payment shall be made to the contractor for ornamental works of this item).
S&F Pre-painted galavalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed
M & L for Vitrified coloured tiles dark shade 8-10mm thick (square/rectangular) polished, area of each tile exc 0.42 sqm but not exc 1.00 sqm each in floors etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6, after dismantling floor, hearth or wall tiling with cement mortar bedding (but not backing), complete all as specified and as directed.
S&F MS iron sections incl drilling and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts including cutting tops to shape as directed, drilling holes, notching for wire, etc., flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165.
S&F 125mm long butt hinges, heavy weight, cold rolled mild steel, and fixed.
S&F 300mm long mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed.
M&L for preparation of new steel surface and applying 2 coat of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
M&L for cutting the sides and cleaning the pot holes on existing road surface and filling with 40 to 50mm (compacted thickness)ready made premixed bituminous material in pot holes exc 1.5 sqm but not exc 10 sqm each and compacting to achieve true level surface matching with existing surfaces. (Make :- Patchmate sustainable/ STP Shalipatch/ Road Rescue AP-3150 Asphalt Repair).
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exc 10 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work wide, complete all as specified and directed.
15mm thick rendering in cement mortar (1:4) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement including a coat of 1mm thick wall care putty. Complete all as specified and directed.
M&L for preparation of newly plaster surface and providing 2 coat of cement base paint over a coat of primer complete all as specified and directed.
Taking down/ out carefully copper/aluminium point wiring for light/fan/bell/ sockets 5/15 Amps complete without accessories as switches,Sockets, holders,ceiling roses,light fitting regulators etc (to be measured separately) and making good the disturbed surface all as directed.
M&L for point wiring complete with 1.5 Sq mm (nominal area) FRLS, PVC insulated un-sheathed and stranded copper conductor cable ISI marked drawing in PVC concealed conduit and PVC conduit fitting including drawing FRLS, PVC insulated unsheathed 1.5 Sqmm copper earth wire, connecting to common earth dolly with and incl Metal flush box of suitable size with modular sheet for fixing modular switches/sockets/fan regulator etc complete all as directed
(a) one light point / fan point/ wall fan point/ bell/ buzzer controlled by one 1-way switch/ bell push.
(b) one socket outlet point 5 amps on the same board.
(c) one socket outlet point 5 amps on the independent board.
(d) All as per Srl Item No 72 here-in-before but with 4 sq mm FRLS copper wire with 4 Sqmm FRLS copper earth wire for independent point.
S&F Modular switch 6 Amp, 1 way, 1 module size complete all as directed.
S&F Modular socket 6 Amp, 2/3 pin, universal type, 2 module size complete all as directed.
S&F Modular switch 16 Amp, 1 way, 1 module size complete all as directed.
S&F Modular socket 16 Amp multipurpose shuttered type, 2 module size with indicator lamp complete all as directed.
S&F Ceiling rose, insulated body, 3 terminal, 240 volts, 5 Amps and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as directed.
S&F Modular Step Fan regulator, 120 watts single / double module, fixed in repairs, complete all as specifed and as directed.
S & F surface and wall mounted LED tube light fitting with polycarbonate housing & interated electronic driver with tube rod of 20 Watt. slim elegant design.and including connected with 3 core 23/0.0076 insulated copper wire from celing rose to fittting connector all as specified and directed.
Taking down ceiling fan any size sealing cable end, dismentling blades and deposit in MES store yard. complete all as specified and as directed.
S & F of ceiling fan(BLDC) 1200 mm sweep, 5 star rating regulator operated, service value not less than 6.0, 240 volts, 240 Volts. 50 Hz complete all as specified and directed.
M&L Sub main wiring with 2 run of 10.0 Sqmm (nominal area) FR, PVC insulated, unsheathed and stranded copper conductor cable ISI marked, drawn in to separate PVC concealed conduit 25 mm dia with and including 10.0 Sqmm (nominal area) FR, PVC insulated, unsheathed and stranded copper conductor cable ISI marked as earth wire, connected with thimble from main DB to sub main DB complete all as directed.
Supply and fix in replacement exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm and depositing the old U/s item to MES store yard.
S & F rigid non metallic PVC conduit 25mm dia inclusive of all tees, bends, elbow, reducers, bell mouth tube ends and fixing accessories such as couplers lock nuts saddles, pipe hook etc. complete including cutting chasis in wall and making good the surface complete all as specified and as directed.
S & F in replacement of MCCB incommer Distribution Board ( Vertical Load line DB) double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, VTPN 04 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCCB as incommer and MCB as outgoing and making all necessary connection complete all as specified and as directed.
S&Fin replacement of MCCB 3 pole of capacity 160A, 10KA ics 100% with thermal magnetic release including spreader/thimble of suitable size and making connection complete all as specified and as directed.
S & F MCB DB conforming to IP 43 - IK 09 with double door , SPN 12 way complete with din rail Neutral and earthing bar after taking out the oldunserviceable DBs connection and making good the disturbed surfaces complete all as specified and as directed.
S&F MCB SP, B Curve type, 10 KA, 10 to 32 Amp, with over load and short circuit protection complete all as directed.
S&F MCB SPN B Curve type, 10 KA,63 Amp, with over load and short circuit protection complete all as directed.
Supply and fix in replacement of Modular AC 25 Amp SP mini MCB, 230 Volts, 50 Hz suitable for module sheet complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 4 core.
Supply and laying of DWC pipe double wall corrugated of size 95x76 mm suitable for protection of electrical cable complete all as specified and directed by Engr-in-charge.
Material and labour for earthing complete with GI earth plate electrode 600mm x 600mm x 6mm thick buried directly in ground not less than 2.25 mtrs below ground level with top edge of plate not less than 1.5 mtr deep below normal ground level connected to galvinised earth wire 4 mm by means of nuts, bolts and check nut to earth plate and to main board or DB including necessary PCC 1:2:4 type B-1 pit, cover frame , GI pipe 15 mm dia light grade for protection and GI pipe 20 mm dia medium grade for watering with funnel, wire mesh, salt and charcoal dust all over the plate all as specified and as directed.
S & F energy efficicent LED fittings 45W LED 6K suitable for builing security light pressure die cast aluminium roadway luminaire with high power LEDs and HF electronic driver complete all as directed.
Supply and fixing in replacement of street light fitting bracket, 1.0 mtr long bent to shape made out of galvanized iron pipe of 25 mm dia size light grade complete with nut, bolts, washer, clamps etc inclusive of one primer coat, one under coat and one finishing coat of silver paint complete all as directed.
Gaurav India Corporations (BID ID -3451068)
Gaurav Construction Company (BID ID -3451120)
LAXMI GROUP (BID ID -3450728)
M/S GEETANJALI ENTERPRISES (BID ID -3451883)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TENDER98.pdf
Tender Documents • 1.00 MB
BOQ_820121.xls
BOQ • 2.76 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .