Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹4.9 CrAdmitted-Finance N A | +12.15% | ₹4.9 Cr | L1 | Admitted-Finance |
| 2 | Not Admitted-Fee/PreQual/Technical PLOT NO 1700 SECTOR 16 NEAR LABOUR CHOWK FARIDABAD NIT FARIDABAD HARYANA 121001 | FARIDABAD | HARYANA | 121001 | - | - | - | Not Admitted-Fee/PreQual/Technical Others-Exemption of Tender Cost & Earnest Money not accepted |
Tender Value
₹2.5 Cr
EMD Value
₹5.0 L
Closing Date
26 May 2022, 2:00 pmClosed
Ex. Engineer (Pr.) CSPZ
Room No. 300, 3rd Floor, Old Hindu College Bldg., Kashmere Gate, Delhi-110006
Development of Museum and Interpretation Centre of Shahjahanabad near Lahori Gate. S.H. - Internal Civil development and finishing work with provision of Electrical Installations, UPS, Air Conditioning and Fire Fighting System in City- S.P. Zone
2022_NDMC_114134_1
EEPRCSPZ/TC/2022-23/02-01
Open Tender
Civil Works
Works
180 days
Ex. Engineer (Pr.) CSPZ
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,500
Yes
₹5.0 L
Yes
O/O Chief Engineer / CSPZ
3 Oct 2022
2 May 2022
27 May 2022
2 May 2022
26 May 2022
20 May 2022
19 May 2022
Amount
Stone work (machine cut edges ) for wall & floors backing filled of required size as per image attached, with a grout of 12 mm thick cement mortar 1:3 (1 Cement : 03 Coarse sand) with an admixture of pigment matching stone shade hard blue stone cobbles 100 mm thick and as per direction of Engineer in charge.
Pdg & Fixing Gwalior stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete,as per direction of Engineer in charge with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 20 MM THICK
Providing and fixing M S Grill & MS Gate in required pattern as per image enclosed , all complete as per direction of Engineer in charge.
Providing and fixing stone jali 40mm thick throughout in cement mortar 1:3 (1 cement : 3 coarse sand)as per image attached, including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, jali slab without any chamfers etc,as per direction of Engineer in charge Raj Nagar plain white stone
Champhering of Edges of Existing Dhollpur Stone 6 mm by 6 mm in required pattern as per image enclosed , all complete as per direction of Engineer in charge.
Providing and fixing stone work as per image enclosed in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, block without any chamfers etc, complete as per direction of Engineer in Charge. White marble stone
Providing and fixing stone work as per image enclosed in cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment, matching the stone shade, block without any chamfers etc, complete as per direction of Engineer in Charge. Red sand stone
Applying two coats of Sealer on the Existing Sand Stone walls & Floors @ 0.20 Litre per sqm of compound concentrated 1:9 as to making the stone with in the permissible water absorption as per IS Code, complete as per direction of Engineer in Charge.
PDG & Fixing Toughened glass 12 mm in required pattern as per image enclosed , all complete as per direction of Engineer in charge.
P/F Toughened glass 12 mm in Aluminium frame in required pattern as per image enclosed , all complete as per direction of Engineer in charge.
Pgd False ceiling in Plaster of Paris in required pattern as per image enclosed , all complete as per direction of Engineer in charge.
Extra for pdg designing work in floor in required pattern as per image enclosed , all complete as per direction of Engineer in charge.Note- Cost of Pdg and Fixing stone is to be paid for saperately.
Pdg & Fixing Haveli work by using Gwalior stone ( Venner) in required thickness as per pattern( image enclosed) in area (1x2) 16 ft x 15 ft & (1x1) 16 ft x 30 ft i/c wooden door etc, all complete as per direction of Engineer in charge.
Pdg & Fixing Kaddapa stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete,as per direction of Engineer in charge with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 18 MM THICK
Pdg & Fixing wooden flooring with coat of fire retardent in required pattern as per image enclosed , all complete as per direction of Engineer in charge.
Pdg & Fixing Heritage tile in floors & walls over 12 mm to 20 mm thick Cement mortar and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete,as per direction of Engineer in charge with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 12 MM THICK
Pdg & Fixing S/case Railing with Teak veneer both side on commercial ply i/c steel work and polishing complete in required pattern as per image enclosed , all complete as per direction of Engineer in charge.
Pdg & Fixing cabinets with Teak board i/c polishing complete in required pattern as per image enclosed , all complete as per direction of Engineer in charge.
Pdg & Fixing Jharokas by using Gwalior stone ( Venner) in required thickness as per pattern ( image enclosed) of size 6 fts x 7 ft as per image enclosed etc, all complete as per direction of Engineer in charge.
Providing and fixing cast iron pillars in required pattern as per image enclosed , all complete as per direction of Engineer in charge.
Providing and fixing white vitreous urinal of approx. size 610 x 390 x 370 mm having pre & post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification MODEL NO URS-WHT-13255 all complete and as per direction of Engineer-in-charge.
Providing and fixing wash basin with C.I. brackets, , including painting of fittings and brackets, cutting and making good the walls wherever require: Wash basin size 580X 405 X 185 mm Model No FNS-WHT-40601 all complete and as perdirection of Engineer-in-charge.
Providing and fixing white vitreous china extended wall mounting water closet of size , approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre, including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.Model No FNS-wht-4095 1UF all complete and as per direction of Engineer-in-charge.
Providing and fixing Basin Mixture Model No qqt-chr-7189 all complete and as per direction of Engineer-in-charge.
Providing and fixing Paper holder with Flap Model No AQN CHR 7753 all complete and as per direction of Engineer-in-charge.
Providing and fixing Soap dispenser with Metallic bottle Model No ACN CHR 1137 N all complete and as per direction of Engineer-in-charge.
Providing and fixing Paper Towel dispenser, Towels Model No PTD - SAP-DT0106CS all complete and as per direction ofEngineer-in-charge.
Providing and fixing Optima Hand Dryer, Satin Model No HDR-SAP-M 99 ACS all complete and as per direction of Engineer-in-charge.
Providing and fixing Kitchen sink Model No 202A all complete and as per direction ofEngineer-in-charge.
Taking out the existing door and windows , removing of the existing paint/ polish, removing and fixing of the fittings along with the damaged part of window/ doorand again fixing after making it good , all complete as per direction of Engineer in charge.Note- Cost of pdg wood etc in making good along with painting and polishing is to be paid for saperately.
Description of Work / Item(s)
Amount
SECTION - I (Electrical) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / ressed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-'C'
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-'C'
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required 3 Module (100mmX75mm)
6 Module (200mmX75mm)
8 Module (125mmX125mm)
12 Module (200mmX150mm)
Installation, testing and commissioning of pre-wired, fitting, complete with all accessories and . directly on ceilingl, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 kV grade as required. 4 X 10 sq. mm (25 mm)
3 x 2.5 Sqmm
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed Steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing 6Way Double Door(4+18), horizontal type three pole nd neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. (25mm)
Supplying and fixing 5amps,to 32 amps rating, 240 volts, "C" curve miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc, as required. Single pole
Triple pole and neutral
Supply and fixing following rating, double pole, 240 volt, isolator in the existing MCB DB complete with connection, testing and commissioning etc, as required. (A) 40 Amp.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
Laying of one number pvc insulated and PVC sheathed/ XLPE power cable of 1.1 kv grade of following size in the existing surface as required Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number pvc insulated and PVC sheathed/ XLPE power cable of 1.1kv grade of following size above in the existing masonry open duct as required. Upto 35 sqmm
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ sub main wiring/ cable as required.
Supply of PVC insulated PVC sheathed Copper . conductor armored cable for working voltage up to 1.1 kv confirming to IS 1554(part-1) of f size (3x2.5 Sqmm)
Supply of 12'(300mm)sweep 900 rpm decorative fresh air fan in Plastic body complete with shutter etc as required. ISI marked.
Fabrication, supply, installation, testing & commissioning of 15 cm to 30 cm deep cubical panel type panel board made out of 1.6 mm thick ms sheet equipped with neutral link Aluminum bus bar 400 amp capacity suitable in all compartment accommodate accessories/ switch gear including interconnection with solid alum. bolt of all switch gear termination on both side incoming/ outgoing complete two coats of approved quality color of enameled paint, earthing etc as reqd.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagneticrelease and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 125 A, 16 KA,TPMCCB
63 Amp, Four Pole Isolator
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm OD
Supply of PVC insulated PVC sheathed Al. conductor armored cable for working voltage up to 1.1 kv confirming to IS 1554(part-1) of following size 4 X 10sqm
Supply, Installation, Testing & Commissioning of of Dali dimmable 35W LED track light with beam angle 24deg distribution - , CCT of 3000K, CRI>90, SDCM≤3. Pane angle: 0-320; tilt angle : 0-90. Input voltage AC 220~240V, 50/60Hz along with Dali VLC driver and Dali track. Service life 50,000hrs@L70B50@Ta25°C. Available in black 9011. CCC/CB/CE/SAA/BIS certified. Similar to Philips ST700T LED30 930PC PSD 1C BK MB
Supply, Installation, Testing & Commissioning of LED indoor surface/suspended COB downlighter made of extruded Aluminium housing suitable for general lighting. The luminaire should have CRI > 80 and CCT of 3000K. The luminaire shall be compliant with IP20 & IK02 classification.The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 1000 lumens and maximum system wattage of 10 Watts. The luminaire shall be designed so as to ensure lumen depreciation of up to 30% over 30k burning hours @ design ambient temp 35 deg C. The electronic driver used shall have a power factor >0.9 , THD <10%. he fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Housing color code Black-RAL9005; Similar to PHILIPS Archspace SP320
Supply, Installation, Testing & Commissioning of recessed LED steplight, made of Aluminium housing in Anthracite grey Colour. Luminaire should be with minimum system lumen output of 85lm and maximum system wattage of 3W. The luminaire should have CCT of 3000K. Luminaire dimension shall be not larger than 115x84x44mm. Similar To Philips LED steplight Model No. 34152
Supply, Installation, Testing & Commissioning of decorative heritage LED wall light, made of synthetic, metal in Black Colour and suitable for outdoor areas. The luminaire shall have a lamp base for E27 bulb with maximum 1x42W. Luminaire dimension shall be not larger than 207x250x266 mm. Similar To Philips Model No. 1738130
Supply, Installation, Testing & Commissioning of Deep recessed LED COB Downlighter made of aluminium housing, fixture should have minimum efficacy at System level (Not Chip Level) >=80lumens/watt with Minimum system Lumens 960 with maximum system wattage of12 W. Should have a focused 36 degree beam angle and minimalistic outer trim. Life of fixture : 35000 burning Hrs., CCT of 6500K , CRI >80, an operating Voltage Range of 160 - 360 VAC and surge up to 2KV , The Luminaire should be BIS compliant. Similar to Philips Deco COB.
Supply, Installation, Testing and Commissioning of LED based Flood light, housing made up of pressure die cast aluminum Alloy with effective thermal management,sturdiness and embossed brand name/logo name of manufacturer. The fixture should have a minimum system efficacy of 100 lumen/Watt and a minimum system lumen output of 3500 lumens and maximum system wattage of 35 Watts.The fixture shall have a CRI of minimum 70 and CCT - 3000K. The fixture shall be designed for a system life of 50,000 hours @70% lumen maintenance. Ingress Protection of IP66 (lamp and gear Compartment) and Mechanical Impact Resistance Rating of IK >=05.The fixture driver should have an operating voltage range of 140-270 V, surge protection of >=3KV, PF >0.9 and THD<20%. The fixture should comply with the parameters as per IS10322. The LED driver should comply to IEC61000-3-2 ed.3.2, 2009 for Harmonics, IEC61347 -2 -13, 2006 in Conjunction with IEC61347-1 ed.2.0, 2007 for Electrical Safety, IEC62384 ed.1.1, 2011 for performance and IEC61547 ed.2.0, 2009, CISPR-15 for EMI. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. Similar to Philips CAT No. - BVP 120
Supply, Installation, Testing and Commissioning of LED Strip light with IP68 & IK06 protection. Product should have sealed with anti-UV polyurethane without color shifting and anti-UV aging.It should have lumen output of 1100Lm/Mtr. with a CCT of 3000K , Product width should not exceed 10mm. It should have better color consistency for visual comfort(SDCM<5) & CRI>80, supply of 24VDC, Class III for safety use Long lifespan 30K hrs. L70B50@35℃ . Product should have accessories of Lead cable (1000mm) with suitable numbers of clip,screw,end caps ,mounting tracks and waterproof connector.The Product should be BIS certified & self declaration of CE certification, Restriction of hazardous substances- Compliant with (RoHS) EN 60598-1: 2015+ A1:2018; Low Voltage Directive (LVD) - 2014/35/EU; EN 60598-2-5:2015; EN 62471: 2008; EN 62493:2015+IEC62778.Cat ref- BGC301 LED 1100lm 3000K L5000 57Watt/5mtr, 1100Lm/m,10mm wide Similar to Philips UNILINEAR FLEX911401719722)
Façade Supporting ZXP399 Lead 2P DC cable 2m (10 pcs)
ZXP399 Jump 2P DC cable 2m (10 pcs)
ZXP399 endcap male connector (20 pcs)
ZXP399 endcap female connector (20 pcs)
3rd party - IP65 100W Driver
ZGC 301 IP connector (10 bags)
3rd party Al profile with clear cover, base clip & end caps as per site 1m
3rd party- IP65 65W driver
Indoor Controls DDBC300-D - 12NC 913703031109
DACM-V3 - 12NC 913703970707
PATPE-WW-X - 12NC 913703433007
DDNP-1501 - 12NC 913703090309
DDNG-485 - 12NC 913703081209
PDEG - 12NC 913703013809
DTK622-USB-J - 12NC 913703090209
SECTION - II (UPS) UPS for back up emergency Supply Supply Assembly Erection testing & commissioning of UPS bank of suitable (N + 1) mode in standby mode. The UPS system shall be suitable for operation on 415 + 10%, 3 phase, 50 + 5% Hz AC supply. The system shall be complete with lead acid type sealed maintenance free batteries suitable to provide a backup of 30 minutes at full load. The interconnection between the UPS to battery and back to UPS; from UPS control panel to individual UPS input connector, from UPS to output panel connector etc. shall be included. The complete system shall be mounted on the expandable rail rack as required at site. The technical details of the UPS shall be as per technical specification. UPS system with 30 minutes battery back-up. 2KVA Off Line Type
SECTION - III (Airconditioning) Refrigerant Piping For Spilt Units Providing and fixing of copper soft/hard refrigerant piping (Circuit length) along with control cabling and earthing should be insulated with 13 mm thick pipe section of nitrile rubber.
Drain Piping For Spilt Units Providing & fixing of uPVC Pipe complete with fittings, supports as per specifications and duly insulated with 9 mm thick pipe section of nitrile rubber as per direction of Engineer-In-Charge & specifications enclosed as reqd. (For Split Units.)
MS stand 25x25x5 for Outdoor unit along with Bird screen fixed on the TOP
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 8 way (4 + 24), Double door
Supply and laying of following size of PVC insulated PVC sheathed Al conductor armoured cable of b1.1 KV grade on surface etc. as reqd 3.5 C x 50 Sqmm
Supply of PVC insulated PVC sheathed Copper . conductor armored cable for working voltage up to 1.1 kv confirming to IS 1554(part-1) of f size 3Cx2.5 Sqmm
3Cx1.5 Sqmm
Laying of one number pvc insulated and PVC sheathed/ XLPE power cable of 1.1 kv grade of following size in the existing surface as required Upto 35 sq. mm (clamped with 1mm thick saddle)
Laying of one number pvc insulated and PVC sheathed/ XLPE power cable of 1.1kv grade of following size above in the existing masonry open duct as required. Upto 35 sqmm
Supplying and making end termination with brass compression gland and aluminum lugs for following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 kV grade as required. 4 X 50 sq. mm (35 mm)
Supplying and fixing 5amps,to 32 amps rating, 240 volts, "C" curve miniature circuit breaker suitable for inductive load of following pole in the existing MCB DB complete with connection testing and commissioning etc, as required. 6 amps. to 32 amps. ratings , TP MCB, “C” curve, 10 KA breaking capacity
SECTION - IV Fire Fighting Providing laying testing commissioning 'C ' class heavy duty MS pipeconfiring to IS 3589 and 1239 including fittinglike elbow, tee, flanges,tapers,nut bolts,gaskets,hangeretc. Fixing the pipe on wall/ceiling with fastner and clamps when laid directly on roof and painting with two or more coats od synthetic enamal paint of required shade complete as reqd. 150mm
Supplying and fixing single headed internal hydrant valve Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conformingto IS 5290 (Type -A) PN rating 1.6 with blank Gunmetal/Stainless Steel cap and chain as required
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post officered, conforming to IS 884 complete with the following as required.20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS:1258512585 20 mm nominal internal dia gun metal globe valve & nozzleDrum and brackets for fixing the equipmets on wall Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required
NON RISING cast Iron double flange SLUICE Valve as per ISI/14846 PN 1.6 rating complete with Bronze body & wedge Stainless Steel spindle, Gland packing, Rubber gasket 150mm DIA Sluice Valve
100mm DIA Sluice Valve
NON RETURN VALVE cast Iron double flange as per IS/5312 PN 1.6 rating complete with Bronze body & wedge Stainless Steel spindle, Gland packing, Rubber gasket 100mm NRV
SITC of electric deiven terrece pump suitable for automatic operation and consisting of following :- Horizontal type,multistage ,centrifugal, split casing pump of cast ironbody and bronze impeller with stainless steel shaft, mechanical seal confirming to IS-1520, 15HP SQ cage induction motor TEFC type suitable for operation on 415V ,3 Phase 50 Hz AC ,with confirming to IP 55 class of protectionfor enclosure ,horizontal foot mounted type with class F insulation,bolts as reqd.with anti vibration pads complete in all respects as reqd. 900 LPM at 35 mtrs head
Supply and fixing of hose cabinet of size 30"x24"x10" (NS) made of 2mm thick MS sheet with 6mm glazed door including necessary locking arrangements suitable to accommodate external hydrant with sluice valve 2 Nos -15 Mts long hose pipe 1Nos-branch pipe,mounted on wall duly painted with post office red externally and white internally with synthetic enmalpaint complete in all respect as reqd.
Providing ,Installation,testing and commissioning 25mm dia gun metal valve
Providing and fixing in position the industrial type pressure gauges with gun metal/ brass valves complete as required
Providing and fixing pressure switch in MS pipe line includingconnectionetc. As reqd
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required 2 way-100 mm dia M.S. Pipe
Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required
Fabrication,supplying,installation and commissioning of wall mounted outdoor /canopy type duly compartmentalized cubical panel board,dust and vermin proof made of 2 mm thick CRCA steel hinged locking arrangement,powder coated in approved shade ,suitable for operation of 415V,3 Ph,50 Hz AC supply with MCB 32 A ,TP 25KA-1 No,Contactor-16 Amps,Overload Relay,Push Button, indicating lights ,Voltmeter 0-500V, 0-30A Ampere meter,Auto/Manual Switch with 15 HP fully automatic operations complete as reqd.
Supply and fixing of signage on alluminium sheet 2.0 mm ( +-10%) fixing on wall /ceiling complete in all repect.
Providing and fixing of ABC Powder type Fire Extinguisher of 6 KGs capacity complete with ISI Mark, fixing on wall as reqd.
Providing and fixing 4.5 KG CO2 type Fire Extinguisher squeeze grip Type, trolly wheek as well as mounting type complete with ISI mark including fixing arrangement etc as reqd
Supply and laying of following size of PVC insulated PVC sheathed Al conductor armoured cable of b1.1 KV grade on surface etc. as reqd 4Cx 10 Sqmm
Supply and laying of following size of PVC insulated PVC sheathed CUconductor UN -armoured flexible cable of b1.1 KV grade on surface etc. as reqd 2C x 1 Sqmm
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
Supplying, installation, testing & commissioning of manual call boxes of MS construction in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required.
Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in M.S. box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required.
Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required ( 6 - Zones)
Description of Work / Item(s)
Part 'A' Civil Work Percentage Rate
Part 'B' Civil Work Market Rate
Part 'C' Electric Work Market Rate
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.06 MB
RFPLahoriGateMuseum.pdf
Tender Documents • 3.88 MB
BOQ_124405.xls
BOQ • 0.59 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .