Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAccepted-AOC | ₹1.9 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹2.0 Cr+₹16.7 L (8.90%)Rejected-Finance | ₹2.0 Cr+₹16.7 L (8.90%) | L2 | Rejected-Finance L2 |
Tender Value
₹2.1 Cr
EMD Value
₹2.4 L
Closing Date
28 Jun 2021, 5:00 pmClosed
Executive Engineer
Jal Shakti Division No-I Kasumpati Shimla-9
Replacement of old rising main 80mm and 65mm dia with G.I. heavy/ medium and API Gr L-210, dismantling of old G.I. pipe of 80mm 65mm dia in rising main and replacement of outlived pumping machinery in LWSS kogi Shalli , LWSS Baldian Phase 2nd and L
2021_HPIPH_48469_1
Shimla/Kasumpti/Mashobra/2.10
Open Tender
Civil Works - Water Works
Item Rate
730 days
Shimla
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,500
₹2.4 L
22 Feb 2022
14 Jun 2021
29 Jun 2021
14 Jun 2021
28 Jun 2021
14 Jun 2021
Amount
Excavation in drains and channels etc. in earth work for pipes upto all depth in all classification of earth work such as pick work, jumper work, saturated soil i/c balling or pumping out water , blasting soft /hard rock or chiseling soft/ hard rock where blasting is prohibited in all lifts including jungle clearance wherever required, trimming and dressing of sides ,levelling of beds to correct grade including shoring /struting ,planking ,timbering and dewatering wherever required stacking the useable /unusable material/soil seperately and after laying,jointing and testing of pipes ,returning the useable soil in treches in 15 cm layers including consolidating of such deposited layer by ramming and watering and then disposing of all surplus excavated soil/unusable material as directed within all leads and lifts including restoration of un-metalled surfaces to its orginal condition and including cost of diversion for traffic, night signals,fixing caution boards,crossing over trenches for access to houses, fencing etc. complete in all respect whithin all leads and lifts as per direction of the Engineer-in-charge.
Providing, laying, & commissioning at site in trenches to be beveled ended pipe conforming to IS/ISO:3183-2007 (Latest with up to date amendments) having minimum wall thickness as specified below & capable of withstanding required test pressure as prescribed in IS/ISO code, in random lengths of 5.5 to 6.5 mtr. The pipe ends shall be levelled suitable for butt welding, including the cost of jointing with butt welding confirming to IS 816-1969 or latest applicable and with uptodate ammendments (leak proof) in three layers at site of work with welded rods of Advani/oeriliken make/ISI marked (welded rods 3mm to 4mm) and all allied accessories whatever required for welding at site, tail pieces,tee bends & other special manufactured from parent pipes as applicable to the particular reach and of approved specification as per site conditions. and cutting of pipes wherever required as per site requirement including carriage in all leads & lifts and as directed by the Engineer-In-Charge. The pipe shall have zinc coating inside & outside confirming to IS-4736-1986 or latest with upto date ammendments & shall be engraved with API L-210. The laying shall confirm to BIS 5822-970 or latest with upto date ammendments to the entire satisfaction of Engineer-In-Charge. (Earth work & cost of MS Flanges after 100meter length shall be measured & paid for seperately.) including all leads, lifts and carriage of materials at site and as per direction and to the entire satisfaction of the Engineer-In-Charge.
LWSS Baldian 2nd stage:
Dia of pipe 80mm Gr.A.L-210 R.D.0 to 1000 Table.28 Wall thickness 4.80mm.
LWSS Kogi Shalli 2nd stage:
Dia of pipe 65mm Gr.A.L-210 R.D.0 to 500 Table.28 Wall thickness 4.80 mm.
Dia of pipe 65mm Gr.A.L-210 R.D.1000 to 1500 Table.17 Wall thickness 4.80mm.
LWSS Tarapur Patengli 2nd stage:
Dia of pipe 65mm Gr.A.L-210 R.D.0 to 1000 Table.28 Wall thickness 4.80 mm
Laying and jointing in trenches galvanised mild steel tube (Heavy grade) of following diameters conforming to IS-1239 as specified below jointed with butt welding according to relevant BIS code 816-1969 including all short pieces bends,tee and other specials etc. made from parent tubes as applicable for the particular reach and of approved specifications as per site conditions including flushing, cleaning and hydraulic testing complete to the best satisfaction of the Engineer-in-charge. The laying of pipes should conform to BIS code 5822-1970 within all leads and lifts complete in all respect.
LWSS Kogi Shalli 2nd stage: Dia of pipe 65mm R.D.1000 to 1500 Table.17
Laying and jointing in trenches galvanised mild steel tube (Medium grade) of following diameters conforming to IS-1239 as specified below jointed with butt welding according to relevant BIS code 816-1969 including all short pieces bends,tee and other specials etc. made from parent tubes as applicable for the particular reach and of approved specifications as per site conditions including flushing, cleaning and hydraulic testing complete to the best satisfaction of the Engineer-in-charge. The laying of pipes should conform to BIS code 5822-1970 within all leads and lifts complete in all respect.
LWSS Baldian 2nd stage:- Dia of pipe 80mm R.D.1000 to 1380 Table.17
LWSS Kogi Shalli 2nd stage: Dia of pipe 65mm R.D.1500 to 1950 Table.5
LWSS Tarapur Patengli 2nd stage:- Dia of Pipe 65mm R.D.0 to 1000 Table.17
P/F of M.S.flanges ISI marked conforming to IS-6392-1971 table. 17 & 28 capable of with standing test pressure of 0.60N/mm2 welded on both sides of 80mm dia GMS Pipes (Medium & heavy grade) with nuts,bolts and 3mm thick ferrado make gasket. The welding is conform to IS-3138-1986 including hydraulic testing at site and painting with anticorrosive paint inside and outside conforming to relevant IS-specifications.
80mm dia LWSS Baldian RD 0 to 1000, Table -28
R.D. 1000 to 1380,Table 17
65mm dia. LWSS Kogi Shalli R.D. 0 to 500 Table-28
RD 500 to 1000 Table- 17
RD 1000 to 1500 Table-17
RD 1500 to 1950 Table-5
65mm dia. LWSS Tarapur Patangli R.D. 0 to 1000 Table-28
R.D. 1000 to 1350,Table 17
Dismenteling of Old G.I. Pipe of various dias.
80mm dia
65mm dia
Providing horizontal spindle horizontal/radial split casing/end section(back pull out arragement)single/ double/multistages centrifugal pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyoti or any other make approved from IPH Deptt as per BIS-1520-1980 with upto date ammendments, read with IS -9137-1978 or latest edition suitable for lifting Clear water for under mentioned characterstics with bronze impellers/priming funnels casing ring and shaft sleaves of bronze, shaft of steel grade-with cast iron casing coupled directly through a flexible coupling on a common C.I/Cast steel base plate (base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/ Squarrel cage screen protected drip proof induction motor of standard make such as Kirloksar/Crompton/Bhel/ NGEF/GEC/SIEMEN/ JAYOTI/ABB or any other make approved from IPH Deptt.as suitable for operation on 415(+)/-5% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+)10% and(-)25 % of the duty point head. The motor should be as per IS:325-1978 with upto date ammendments read with IS 900-1972. It should include cost of bearing nuts,bolts and pointing etc. and should meet the following requirements:-
LWSS Kogi Shalli.
(I) Discharge (Q) 3.20 LPS. Per set. (ii) Total Dynamic Head: 317.54 Meters.(a) LWL in sump well(h) : - Meters. (b) Shaft level :- - Meters. © Level at discharge point : - Meters. (d) Suction lift :- Meters. (e) Residual head:- 3.00 Meters. (f) Static head:- 261 Meters.(iii) Rising main(a) Length. 1950 Meters.(b) Dia :-65 mm.(iv) Pumping hours. 8 hours.(v) Altitude of Installation above MSL - Meters.(vi) Characteristics of water (a) Temperature oC (b) Abient Temperature oC © Turbidity JTU (d)Alkalanity Mg/CA CO3 (e) Size of the solids. Mm.(f) Other. Pumps Specifications: Make:- . (ii) Model :- (iii) No.of stages .(iv)Material manufactures certificate to be appended (I) Head(H):- . (ii)Discharge(Q) ./Hr/ set .(iii)BHP absorbed (iv)Efficiency(n):- (v) NPSH(K) (b) Motors Specification:- I) Make:- .ii) Model:- . 2*25HP.
iii) Motor rating (KW ) .iv) Speed.:- (v) Insulation.
© Coupling ] (d) Base Plate ].
Supply of suitable direct on line/oil immersed star delta /ATS/Stator rotor starter of standard make such as MEI/Kilburn/Jyoti/ Siemens/ Larson and Turbo conforming to BIS-8544-1979 latest with upto date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type overload release & dash pot, time lag,under voltage release with initial oil filling.
Note:-Star delta starter upto 37.5 KW,ATS between 37.5 KW to 50 KW and starter rotor starter with slipring motor beyond 50 KW.
Providing MS .sheet,16 SWG steel fabricated floor mounted closed(Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, comprising and capable of mounting the following accessories with all internal connections: The drawing of panel board shall be subject to approval of Engineer-in-charge.
ICTP switches with HRC fuses of Kilburn/L&T/Siemens/Standard/Havells make and having Capacity 30% extra of the operational rating as per IS:4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTP SWITCHES: I) Type : ii)Make:- iii)Capacity Amp.
Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and one copper bar of half the rating of full length for neutral phase as per BIS:8084-1976 and 11353-1985 read with 5578-1985 with upto date ammendments. BUS BAR CHAMBER:- i)Type: - . ii)Make:- iii)Rating
ACB/M.C.B/Oil Circuit Breaker of suitable capacity of Kilburn/ L&T/ MEI/GEC/Standard make on incoming feeder for motor offered by the tenderer conforming to BIS-2516-1985 latest with upto date ammendments with initial oil filling whenever required and neutral linked under voltage release.
Three phase Indicating lamps complete with toggle switches for individual motors as per IS 3452(P-I&II) with upto date ammendments. THREE PHASE INDICATOR:- i) Type:- ii) Make:- iii) Capacity.
Earth leakage circuit breaker relay of recommended make such as (Kilburn/L&T/MEI/ GEC) conforming to BIS- 2516-1977 with upto date ammendment and of suitable range which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. ELCB/ELR:- I)Make :- (CEI approved). ii)Type: iii) Range.
Providing Hour run meter of reputed make for four digit capacity conforming to BIS:722(Latest edition)/recommendations. HOUR RUN METER:- I) Type:- ii)Make:- iii)Capacity:- Hrs.
Suitable three phase voltage monitor relay with all protection and usual indicator and electric siren against single phasing No/ low voltage,high voltage & overloading and phase voltage difference as per IS:3842 with upto date ammendments.
Change over switch of reputed make and suitable capacity
Single phase preventor of reputed make and suitable capacity conforming to IS:1248 (P-V)-1983 with upto date ammendments.
Supply of Kirloskar/Leader/KSB/fouress/pellicon make of Cast steel double flanged sluice valve having size nominal delivery size of pump and capable of withstanding nominal seat pressure as mentioned in item No.1 (a) & conforming to BIS/API-standards with upto date ammendments for delivery line of pump.
(Note:- The sluice valve shall conform to BIS-780-1984 latest with upto date ammedments. However, if the seat pressure exceeds the limits prescribed in BIS: 780 then the sluice valves shall be of Cast steel conforming to class 150 ASA (Seat pressure 21 kg/cm^2 ) or Class 300- ASA )Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelocon make of Cast Iron/Cast Steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the normal delivery size of .pump and capable of withstanding nominal seat pressure as mentioned in item No.1 (a) & comforming to BIS/API standard with upto date ammendments for delivery line of pump.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 kg/cm^2) or Class 300 ASA (Seat pressure 52 kg/cm^2) as per BIS: 1414(API -600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelocon make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of Rising main as mentioned in item No.1 (c) for with standing normal seat pressure as per item No.1(a).
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to Class 150 ASA ((Seat pressure 21 kg/cm^2 class 300 ASA (Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).
Supply of Kirloskar/Jyoti/ Standard/Kilburn/Bir/ Kartar make cast iron flanged screwed type foot valve ( in case suction lift is involved) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow is not more than 2.50 mtr/sec. with strainer having net area of its openings equal to three to four times of X-sectional area of flow in suction pipe conforming to BIS- 4038-1986 or latest with up to date ammendments including all leads and lifts.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelocon make of Cast Iron double flanged sluice valve ( in case suction is +tive) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 2.50 mtrs/ sec. with stainer het area of its opening equal to three to four timjes of X-sectional area of flow in suction pipe and conforming to BIS/API standards with upto date ammendments i/c all leads and lift and as directed by the Engineer-in-charge.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 kg/cm^2) or Class 300 ASA (Seat pressure 52 kg/cm^2) as per BIS: 1414(API -600).
Prov. laying jointing and testing at site suitable size copper PVC insulated armoured power three and half core cable conforming to BIS 1554 (Part.I) 1988 or latest upto date ammendments or siemens/Gloster/ ICC/ EICO/National/IEC make from meter of HPSEB to circuit breaker and from circuit breaker to bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/ accessories, such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.
Prov. laying jointing and testing at site suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (Part.I) 1988 or latest upto date ammendments or siemens/Gloster/ ICC/ EICO/ National/ IEC make from meter of HPSEB to circuit breaker and from circuit breaker to bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories, such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying double loop earthing with copper plate 600mmx600mmx3mm thick electrode complete with material such as charcoal and common salt G.I.Pipes thimbles nuts and bolts,digging of pits, G.I.Wiring and 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with upto date ammendments suitable for above motors and other electrical equipments i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.
Supply and errection of floor/wall mounted power factor shunt capacitor conforming to BIS:2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T/Kilburn/Standard/Siemens/Havells make ICTP switches conforming to BIS:4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c cost of carriage of material in all leads and lifts & as directed by Engineer-in-charge.
Supply of 100mm circular dia pressure gauge of suitable range & standard make such as Fiebig/Bourden/ Precision/PREGA with all accessories such as stop cock, copper tubing etc.conformfing to BIS: 3624-1987 or latest with upto date ammendments.
Prov. and fixing double flanged suction, delivery pipe and common header considering site requirement, NPSH required and available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets 3mm thick as per BIS:2712-1978 nuts and bolts as per 1264-1983 & special upto 5mtrs. away from the outer wall of pump house as per layout drawings approved by Engneer-in-charge. The pipes shall be capable of with standing minimum 1.5 times the total pressure as indicated in item No.1(a) or total dynamic pressure+ surge pressure whichever is more. The size of suction pipe shall be one or two sizes larger than the suction size of pump such that velocity of flow in suction pipe is not more than 2.50 mtrs./sec. & delivery pipe shall be of size one size larger than nominal delivery size of pump i/c cost of carriage of material in all leads and lifts and as per directed by the Engineer-in-charge.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer-in-charge.
Supply of antivibration .pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Erection of all equipment from Sr.No. at Serial No. 6 to 13, 20 to 25 as per the systematic drawing attached with the tender documents(Drg. No.1).
LWSS Baldian Phase.2nd:
Providing horizontal spindle horizontal/radial split casing/end section(back pull out arragement)single/ double/multistages centrifugal pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyoti or any other make approved from IPH Deptt as per BIS-1520-1980 with upto date ammendments, read with IS -9137-1978 or latest edition suitable for lifting Clear water for under mentioned characterstics with bronze impellers/priming funnels casing ring and shaft sleaves of bronze, shaft of steel grade-with cast iron casing coupled directly through a flexible coupling on a common C.I/Cast steel base plate (base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/ Squarrel cage screen protected drip proof induction motor of standard make such as Kirloksar/Crompton/Bhel/ NGEF/GEC/SIEMEN/ JAYOTI/ABB or any other make approved from IPH Deptt.as suitable for operation on 415(+)/-5% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+)10% and(-)25 % of the duty point head. The motor should be as per IS:325-1978 with upto date ammendments read with IS 900-1972. It should include cost of bearing nuts,bolts and pointing etc. and should meet the following requirements:-
(II) Discharge (Q) 4.06 LPS. Per set. (ii) Total Dynamic Head: 457.63 Meters.(a) LWL in sump well(h) : - Meters. (b) Shaft level :- - Meters. © Level at discharge point : - Meters. (d) Suction lift :- Meters. (e) Residual head:- 3.00 Meters. (f) Static head:- 433.00 Meters.(iii) Rising main(a) Length. 1380 Meters.(b) Dia :80 mm.(iv) Pumping hours. 8 hours.(v) Altitude of Installation above MSL - Meters.(vi) Characteristics of water (a) Temperature oC (b) Abient Temperature oC © Turbidity JTU (d)Alkalanity Mg/CA CO3 (e) Size of the solids. Mm.(f) Other. Pumps Specifications: Make:- . (ii) Model :- (iii) No.of stages .(iv)Material manufactures certificate to be appended (I) Head(H):- . (ii)Discharge(Q) ./Hr/ set .(iii)BHP absorbed (iv)Efficiency(n):- (v) NPSH(K) (b) Motors Specification:- I) Make:- .ii) Model:- . 2*45 HP.
iii) Motor rating (KW ) .iv) Speed.:- (v) Insulation.
© Coupling ] (d) Base Plate ].
Supply of suitable direct on line/oil immersed star delta /ATS/Stator rotor starter of standard make such as MEI/Kilburn/Jyuoti/ Siemens/ Larson and Turbo conforming to BIS-8544-1979 latest with upto date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type overload release & dash pot, time lag,under voltage release with initial oil filling.
Note:-Star delta starter upto 37.5 KW,ATS between 37.5 KW to 50 KW and starter rotor starter with slipring motor beyond 50 KW.
Providing MS .sheet,16 SWG steel fabricated floor mounted closed(Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, comprising and capable of mounting the following accessories with all internal connections: The drawing of panel board shall be subject to approval of Engineer-in-charge.
ICTP switches with HRC fuses of Kilburn/L&T/Siemens/Standard/Havells make and having Capacity 30% extra of the operational rating as per IS:4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTP SWITCHES: I) Type : ii)Make:- iii)Capacity Amp.
Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and one copper bar of half the rating of full length for neutral phase as per BIS:8084-1976 and 11353-1985 read with 5578-1985 with upto date ammendments. BUS BAR CHAMBER:- i)Type: - . ii)Make:- iii)Rating
ACB/M.C.B/Oil Circuit Breaker of suitable capacity of Kilburn/ L&T/ MEI/GEC/Standard make on incoming feeder for motor offered by the tenderer conforming to BIS-2516-1985 latest with upto date ammendments with initial oil filling whenever required and neutral linked under voltage release.
Three phase Indicating lamps complete with toggle switches for individual motors as per IS 3452(P-I&II) with upto date ammendments. THREE PHASE INDICATOR:- i) Type:- ii) Make:- iii) Capacity.
Earth leakage circuit breaker relay of recommended make such as (Kilburn/L&T/MEI/ GEC) conforming to BIS- 2516-1977 with upto date ammendment and of suitable range which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. ELCB/ELR:- I)Make :- (CEI approved). ii)Type: iii) Range.
Providing Hour run meter of reputed make for four digit capacity conforming to BIS:722(Latest edition)/recommendations. HOUR RUN METER:- I) Type:- ii)Make:- iii)Capacity:- Hrs.
Suitable three phase voltage monitor relay with all protection and usual indicator and electric siren against single phasing No/ low voltage,high voltage & overloading and phase voltage difference as per IS:3842 with upto date ammendments.
Change over switch of reputed make and suitable capacity
Single phase preventor of reputed make and suitable capacity conforming to IS:1248 (P-V)-1983 with upto date ammendments.
Supply of Kirloskar/Leader/KSB/fouress/pellicon make of Cast steel double flanged sluice valve having size nominal delivery size of pump and capable of withstanding nominal seat pressure as mentioned in item No.1 (a) & conforming to BIS/API-standards with upto date ammendments for delivery line of pump.
(Note:- The sluice valve shall conform to BIS-780-1984 latest with upto date ammedments. However, if the seat pressure exceeds the limits prescribed in BIS: 780 then the sluice valves shall be of Cast steel conforming to class 150 ASA (Seat pressure 21 kg/cm^2 ) or Class 300- ASA )Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelocon make of Cast Iron/Cast Steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the normal delivery size of .pump and capable of withstanding nominal seat pressure as mentioned in item No.1 (a) & comforming to BIS/API standard with upto date ammendments for delivery line of pump.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 kg/cm^2) or Class 300 ASA (Seat pressure 52 kg/cm^2) as per BIS: 1414(API -600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelocon make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of Rising main as mentioned in item No.1 (c) for with standing normal seat pressure as per item No.1(a).
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to Class 150 ASA ((Seat pressure 21 kg/cm^2 class 300 ASA (Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).
Supply of Kirloskar/Jyoti/ Standard/Kilburn/Bir/ Kartar make cast iron flanged screwed type foot valve ( in case suction lift is involved) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow is not more than 2.50 mtr/sec. with strainer having net area of its openings equal to three to four times of X-sectional area of flow in suction pipe conforming to BIS- 4038-1986 or latest with up to date ammendments including all leads and lifts.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelocon make of Cast Iron double flanged sluice valve ( in case suction is +tive) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 2.50 mtrs/ sec. with stainer het area of its opening equal to three to four timjes of X-sectional area of flow in suction pipe and conforming to BIS/API standards with upto date ammendments i/c all leads and lift and as directed by the Engineer-in-charge.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 kg/cm^2) or Class 300 ASA (Seat pressure 52 kg/cm^2) as per BIS: 1414(API -600).
Prov. laying jointing and testing at site suitable size copper PVC insulated armoured power three and half core cable conforming to BIS 1554 (Part.I) 1988 or latest upto date ammendments or siemens/Gloster/ ICC/ EICO/National/IEC make from meter of HPSEB to circuit breaker and from circuit breaker to bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/ accessories, such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.
Prov. laying jointing and testing at site suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (Part.I) 1988 or latest upto date ammendments or siemens/Gloster/ ICC/ EICO/ National/ IEC make from meter of HPSEB to circuit breaker and from circuit breaker to bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories, such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying double loop earthing with copper plate 600mmx600mmx3mm thick electrode complete with material such as charcoal and common salt G.I.Pipes thimbles nuts and bolts,digging of pits, G.I.Wiring and 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with upto date ammendments suitable for above motors and other electrical equipments i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.
Supply and errection of floor/wall mounted power factor shunt capacitor conforming to BIS:2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T/Kilburn/Standard/Siemens/Havells make ICTP switches conforming to BIS:4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c cost of carriage of material in all leads and lifts & as directed by Engineer-in-charge.
Supply of 100mm circular dia pressure gauge of suitable range & standard make such as Fiebig/Bourden/ Precision/PREGA with all accessories such as stop cock, copper tubing etc.conformfing to BIS: 3624-1987 or latest with upto date ammendments.
Prov. and fixing double flanged suction, delivery pipe and common header considering site requirement, NPSH required and available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets 3mm thick as per BIS:2712-1978 nuts and bolts as per 1264-1983 & special upto 5mtrs. away from the outer wall of pump house as per layout drawings approved by Engneer-in-charge. The pipes shall be capable of with standing minimum 1.5 times the total pressure as indicated in item No.1(a) or total dynamic pressure+ surge pressure whichever is more. The size of suction pipe shall be one or two sizes larger than the suction size of pump such that velocity of flow in suction pipe is not more than 2.50 mtrs./sec. & delivery pipe shall be of size one size larger than nominal delivery size of pump i/c cost of carriage of material in all leads and lifts and as per directed by the Engineer-in-charge.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer-in-charge.
Supply of antivibration .pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Erection of all equipment from Sr.No. at Serial No. 33.01 to 40, 47 to 52 as per the systematic drawing attached with the tender documents(Drg. No.1).
LWSS Tarapur Patengli:
Providing horizontal spindle horizontal/radial split casing/end section(back pull out arragement)single/ double/multistages centrifugal pump or combination of pumps, in series/parallel of recommended make such as Mather and Platt/KSB//Becon weir/Kirloskar/ BE/Jyoti or any other make approved from IPH Deptt as per BIS-1520-1980 with upto date ammendments, read with IS -9137-1978 or latest edition suitable for lifting Clear water for under mentioned characterstics with bronze impellers/priming funnels casing ring and shaft sleaves of bronze, shaft of steel grade-with cast iron casing coupled directly through a flexible coupling on a common C.I/Cast steel base plate (base plate to be from the manufacturers of the pumping unit only) to Slip/Ring/ Squarrel cage screen protected drip proof induction motor of standard make such as Kirloksar/Crompton/Bhel/ NGEF/GEC/SIEMEN/ JAYOTI/ABB or any other make approved from IPH Deptt.as suitable for operation on 415(+)/-5% volts, 50 cycles/second, 3 phase AC electric supply. The power of electric motor should be atleast 10% in excess of the maximum power required by the pump in the operation range of (+)10% and(-)25 % of the duty point head. The motor should be as per IS:325-1978 with upto date ammendments read with IS 900-1972. It should include cost of bearing nuts,bolts and pointing etc. and should meet the following requirements:-
(III) Discharge (Q) 3.14 LPS. Per set. (ii) Total Dynamic Head: 534.27 Meters.(a) LWL in sump well(h) : - Meters. (b) Shaft level :- - Meters. © Level at discharge point : - Meters. (d) Suction lift :- Meters. (e) Residual head:- 3.00 Meters. (f) Static head:- 495.00 Meters.(iii) Rising main(a) Length.1350 Meters.(b) Dia :-65 mm.(iv) Pumping hours. 8 hours.(v) Altitude of Installation above MSL - Meters.(vi) Characteristics of water (a) Temperature oC (b) Abient Temperature oC © Turbidity JTU (d)Alkalanity Mg/CA CO3 (e) Size of the solids. Mm.(f) Other. Pumps Specifications: Make:- . (ii) Model :- (iii) No.of stages .(iv)Material manufactures certificate to be appended (I) Head(H):- . (ii)Discharge(Q) ./Hr/ set .(iii)BHP absorbed (iv)Efficiency(n):- (v) NPSH(K) (b) Motors Specification:- I) Make:- .ii) Model:- . 2*40 HP.
iii) Motor rating (KW ) .iv) Speed.:- (v) Insulation.
© Coupling ] (d) Base Plate ].
Supply of suitable direct on line/oil immersed star delta /ATS/Stator rotor starter of standard make such as MEI/Kilburn/Jyuoti/ Siemens/ Larson and Turbo conforming to BIS-8544-1979 latest with upto date ammendments for squirrel cage/slip-ring motor (make to be specified by the tenderers) mounted on panel board with magnetic type overload release & dash pot, time lag,under voltage release with initial oil filling.
Note:-Star delta starter upto 37.5 KW,ATS between 37.5 KW to 50 KW and starter rotor starter with slipring motor beyond 50 KW.
Providing MS .sheet,16 SWG steel fabricated floor mounted closed(Almirah type) switch board including angle iron post of suitable height and size ISA 40x40x6mm,duly painted, comprising and capable of mounting the following accessories with all internal connections: The drawing of panel board shall be subject to approval of Engineer-in-charge.
ICTP switches with HRC fuses of Kilburn/L&T/Siemens/Standard/Havells make and having Capacity 30% extra of the operational rating as per IS:4064-1978 with upto date ammendments immediately after the power meter of HPSEB. ICTP SWITCHES: I) Type : ii)Make:- iii)Capacity Amp.
Bus bar chamber having three copper bars of suitable rating for full length equal to the width of the board for three live phases and one copper bar of half the rating of full length for neutral phase as per BIS:8084-1976 and 11353-1985 read with 5578-1985 with upto date ammendments. BUS BAR CHAMBER:- i)Type: - . ii)Make:- iii)Rating
ACB/M.C.B/Oil Circuit Breaker of suitable capacity of Kilburn/ L&T/ MEI/GEC/Standard make on incoming feeder for motor offered by the tenderer conforming to BIS-2516-1985 latest with upto date ammendments with initial oil filling whenever required and neutral linked under voltage release.
Three phase Indicating lamps complete with toggle switches for individual motors as per IS 3452(P-I&II) with upto date ammendments. THREE PHASE INDICATOR:- i) Type:- ii) Make:- iii) Capacity.
Earth leakage circuit breaker relay of recommended make such as (Kilburn/L&T/MEI/ GEC) conforming to BIS- 2516-1977 with upto date ammendment and of suitable range which should have control box operating handle and trip/reset bush button on/off indicators, re-indicating off spring condition of the circuit breaker for over current protection. The circuit should be equipped with magnet thermal release with metallic tape etc. It should also be fitted with earth fault for tripping of breaker on occurrence of earth fault on off breaker load side end. ELCB/ELR:- I)Make :- (CEI approved). ii)Type: iii) Range.
Providing Hour run meter of reputed make for four digit capacity conforming to BIS:722(Latest edition)/recommendations. HOUR RUN METER:- I) Type:- ii)Make:- iii)Capacity:- Hrs.
Suitable three phase voltage monitor relay with all protection and usual indicator and electric siren against single phasing No/ low voltage,high voltage & overloading and phase voltage difference as per IS:3842 with upto date ammendments.
Change over switch of reputed make and suitable capacity
Single phase preventor of reputed make and suitable capacity conforming to IS:1248 (P-V)-1983 with upto date ammendments.
Supply of Kirloskar/Leader/KSB/fouress/pellicon make of Cast steel double flanged sluice valve having size nominal delivery size of pump and capable of withstanding nominal seat pressure as mentioned in item No.1 (a) & conforming to BIS/API-standards with upto date ammendments for delivery line of pump.
(Note:- The sluice valve shall conform to BIS-780-1984 latest with upto date ammedments. However, if the seat pressure exceeds the limits prescribed in BIS: 780 then the sluice valves shall be of Cast steel conforming to class 150 ASA (Seat pressure 21 kg/cm^2 ) or Class 300- ASA )Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelocon make of Cast Iron/Cast Steel double flanged swing check type reflux valve for delivery line of pump having bye pass arrangement & size one size higher than the normal delivery size of .pump and capable of withstanding nominal seat pressure as mentioned in item No.1 (a) & comforming to BIS/API standard with upto date ammendments for delivery line of pump.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 kg/cm^2) or Class 300 ASA (Seat pressure 52 kg/cm^2) as per BIS: 1414(API -600).
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelocon make of suitable size Cast Steel double flanged swing check type reflux valve having bye pass arrangement & size equal to dia of Rising main as mentioned in item No.1 (c) for with standing normal seat pressure as per item No.1(a).
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to Class 150 ASA ((Seat pressure 21 kg/cm^2 class 300 ASA (Seat pressure 52 kg/cm^2) as per BS: 1414(API -600).
Supply of Kirloskar/Jyoti/ Standard/Kilburn/Bir/ Kartar make cast iron flanged screwed type foot valve ( in case suction lift is involved) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow is not more than 2.50 mtr/sec. with strainer having net area of its openings equal to three to four times of X-sectional area of flow in suction pipe conforming to BIS- 4038-1986 or latest with up to date ammendments including all leads and lifts.
Supply of Kirloskar/Kilburn/IVC/Fouress/Gled/BHEL/Leader/Bir/Kartar/ Pelocon make of Cast Iron double flanged sluice valve ( in case suction is +tive) for suction pipe having size one or two size larger than suction size of pump such that velocity of flow in suction pipe is not more than 2.50 mtrs/ sec. with stainer het area of its opening equal to three to four timjes of X-sectional area of flow in suction pipe and conforming to BIS/API standards with upto date ammendments i/c all leads and lift and as directed by the Engineer-in-charge.
NOTE:- The reflux valve shall conform to BIS 5312-1984 (part I) latest with up to date ammendments. However if the seat pressure exceeds the limits prescribed in BIS 5312 then the reflux valves shall be of cast steel conforming to class 150 ASA (Seat pressure 21 kg/cm^2) or Class 300 ASA (Seat pressure 52 kg/cm^2) as per BIS: 1414(API -600).
Prov. laying jointing and testing at site suitable size copper PVC insulated armoured power three and half core cable conforming to BIS 1554 (Part.I) 1988 or latest upto date ammendments or siemens/Gloster/ ICC/ EICO/National/IEC make from meter of HPSEB to circuit breaker and from circuit breaker to bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/ accessories, such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.
Prov. laying jointing and testing at site suitable size copper PVC insulated armoured power three core cable conforming to BIS 1554 (Part.I) 1988 or latest upto date ammendments or siemens/Gloster/ ICC/ EICO/ National/ IEC make from meter of HPSEB to circuit breaker and from circuit breaker to bus bar switch and starter (one cable carrying all three phases) including all other electrical equipment/accessories, such as thimbles, flexble pipe, solder, nuts and bolts, cable glands etc. laid in pipes or trenches under floor. The type, size and make will be subject to approval of HPSEB authorities. In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.
Providing and laying double loop earthing with copper plate 600mmx600mmx3mm thick electrode complete with material such as charcoal and common salt G.I.Pipes thimbles nuts and bolts,digging of pits, G.I.Wiring and 25x5mm copper strips of required capacity conforming to BIS 3043-1987 latest with upto date ammendments suitable for above motors and other electrical equipments i/c cost of carriage of material in all leads and lifts and as directed by the Engineer-in-charge.
Supply and errection of floor/wall mounted power factor shunt capacitor conforming to BIS:2834-1986 or latest with upto date ammendments of BHEL/GEC/Machneil/ Mager/Bajaj/L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of required KVAR according to HP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including L&T/Kilburn/Standard/Siemens/Havells make ICTP switches conforming to BIS:4064-1978 or latest with HRC fuses (Range to be specified by the tenderer) i/c cost of carriage of material in all leads and lifts & as directed by Engineer-in-charge.
Supply of 100mm circular dia pressure gauge of suitable range & standard make such as Fiebig/Bourden/ Precision/PREGA with all accessories such as stop cock, copper tubing etc.conformfing to BIS: 3624-1987 or latest with upto date ammendments.
Prov. and fixing double flanged suction, delivery pipe and common header considering site requirement, NPSH required and available & common header having area equal to two times the area of delivery branch of pump including tapers, flanges, rubber gaskets 3mm thick as per BIS:2712-1978 nuts and bolts as per 1264-1983 & special upto 5mtrs. away from the outer wall of pump house as per layout drawings approved by Engneer-in-charge. The pipes shall be capable of with standing minimum 1.5 times the total pressure as indicated in item No.1(a) or total dynamic pressure+ surge pressure whichever is more. The size of suction pipe shall be one or two sizes larger than the suction size of pump such that velocity of flow in suction pipe is not more than 2.50 mtrs./sec. & delivery pipe shall be of size one size larger than nominal delivery size of pump i/c cost of carriage of material in all leads and lifts and as per directed by the Engineer-in-charge.
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer-in-charge.
Supply of antivibration .pads conforming to BIS 6337-1971 or latest with upto date ammendments of suitable size for above machinery.
Erection of all equipment from Sr.No. at Serial No. 61.01 to 68, 75 to 79 as per the systematic drawing attached with the tender documents(Drg. No.1).
Laying and jointing in trenches,galvanised mild steel tubes(Light grade) i/c P/F of tube fittings such as Tee, elbow, union & nipple.(earth work in trenches to be measured and paid for separately)i/c all leads and lifts complete in all respect.Labour rate only.
15mm dia.nominal bore.
20mm dia.nominal bore.
25mm dia.nominal bore.
32mm dia.nominal bore.
40mm dia.nominal bore.
65mm dia.nominal bore.
Prov. and fixing brass full way valve with wheel of superior quality including all leads and lifts In :-
15mm dia.nominal bore.
20mm dia.nominal bore.
25mm dia.nominal bore.
32mm dia.nominal bore.
40mm dia.nominal bore.
50mm dia.nominal bore.
65mm dia.nominal bore.
Dinesh Singh Thakur
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .