Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC STREET NO 10 MALLOMAZRA ROAD BHAKHRA ENCLAVE PATIALA PB | PATIALA | PUNJAB | 140401 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹9.1 L+₹42,620 (4.94%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹9.2 L+₹55,895 (6.48%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹10.7 L+₹2.1 L (24.0%)Rejected-Finance ASTBAL MOHALLA BANASAR BAGH ROAD PATIALA GATE SANGRUR 148001 | SANGRUR | SANGRUR | PUNJAB | 148001 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹11.3 L+₹2.6 L (30.4%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
9 Aug 2021, 6:00 pmClosed
Sh Himanshu
MILITARY ENGINEER SERVICES GARRISON ENGINEER SOUTH TARAPORE ENCLAVE PATIALA CANTT
As per tender documents
2021_MES_459074_1
GE(S)/PAT-17/N/2021-22
Open Tender
Civil Works
Item Rate
180 days
Mil Stn Nabha
Refer tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (S) Patiala
₹30,000
Yes
19 Aug 2021
12 Jul 2021
11 Aug 2021
12 Jul 2021
9 Aug 2021
26 Jul 2021
12 Jul 2021 - 19 Jul 2021
Amount
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete with fittings and fixtures such as switches, ceiling roses, pendants, regulators, socket, lamp holders brackets, bulk head fittings etc removing material for taking credit ( credit shall be recovered as per credit Sch attached) and also making good disturbed surfaces of wall, floors etc all as specified and as directed by the Engineer-in-Charge.
M&L for point wiring with 1.50 sqmm in copper conductor cable (multistrand) FRLS single core PVC insulated cable in and including PVC concealed conduit (ISI Marked) of heavy duly with all accessories ie PVC gutties etc terminated in sunken/pressed metal flush box and white modular cover plate with frame for mounting of switches /sockets/ fan regulators etc and continuous earth wire 1.5 Sqmm copper cable PVC insulated FRLS controlled by one switch for one light/fan/sockets point/ all as specified and directed by Engr-in-Charge in ceiling Portion surface conduit wiring to be done. Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth. (iii) Necessary cutting chasing where ever required & making good the disturbed surfaces matching with the existing shall be inclusive in quoted rate.
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on the same board with other switches complete all as specified and as directed by the Engineer-in-Charge.
All as per item No 2 above, but for one 3/5 pin socket outlet 5 Amp on independent board complete all as specified and as directed by the Engineer-in-Charge.
All as per serial item No 2 here-in-before , but for one socket outlet 15 Amps on independent board with 2.5 Sqmm copper conductor ( Multi-stranded) PVC insulated and unsheating electric cable 1100 volts (ISI Marked) including PVC insulated and unsheathed electric cable 1100 volts 1.5 Sqmm copper stranded conductor as continuous earth wire connected to common earth dolly complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular switch 1 way, 6 Amps, 1 module complete all as specified.
Supply & Fix of modular type, switch 1 way, 16 Amps, 1 module complete all as specified. Make : Legrand/ Roma/ ORIS L&T/ Siemens/ Wood
Supply & Fix of modular type, Bell push 1 way, 6 Amps, 1 module complete all as specified. Make : Legrand/ Roma/ ORIS L&T/ Siemens/ Wood
Supply & Fix modular type, socket 5 pin 6 Amps, 2 module complete all as specified. Make : Legrand/ Roma/ ORIS L&T/ Siemens
Supply & Fix modular socket 5 pin 6/16 Amps, combination type 2 moduel complete all as specified. Make : Legrand/ Roma/ ORIS L&T/ Siemens/ Wood
Supply & Fix modular Fan regulator step type, 120 watts, 2 module complete all as specified. Make : Legrand/ Roma/ ORIS L&T/ Siemens/ Wood
S&F switch piano, flush button type, single pole , one way 5 Amps fixed in repairs complete all as specified and directed. .Make : Anchor/ Havells/ SSK
S&F switch piano, flush button type, single pole , one way 15 Amps fixed in repairs complete all as specified and directed. Make : Anchor/ Havells/ SSK
S&F socket outlet 3 pin and 2 pin, 5 Amps , flush type complete fixed in repairs all as specified complete all as specified and directed. Make : Anchor/ Havells/ SSK
S&F socket outlet 2-in-1, 3 pin , 5 and 15 Amps, flush type fixed in repairs complete all as specified complete all as specified and directed. Make : Anchor/ Havells/ SSK
S&F electronic fan regulator (5 Step up type) 280 Volts suitable for ceiling fan fixed in repairs complete all as specified and directed. Make : Anchor/ Havells/ SSK
Material and labour for ceiling rose surface type, 65 mm x 50 mm two to three terminals / PVC / polycarbonate, isolated body fixed on PVC block complete all specified and as directed by the Engineer-in-Charge.
Supply and fixing in replacement of existing unserviceable sub main wiring two single core PVC insulated and unsheathed cable with 6 Sqmm multi -strand copper conductor drawing in PVC casing caping/ Conduit with 4 Sqmm PVC copper conductor cable as in earth wire system ,including taking out old wiring complete all as directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size . (iii) Necessary cutting chasing shall be included in this item. (iv) One run of all Cables together shall be measured as one unit.
M&L for replacement of existing unserviceable Sub main wiring in PVC casing caping/ conduit with 2 Nos single core PVC insulated copper conductor cable flame proof size 4 sqmm multistrand and 2.5 sqmm PVC insulated flame proof earth wire using suitable size of copper thimble all as directed. Note: (i) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth . (ii) Connections of cables with MCBs or bus bars shall be done through brass/copper thimbles of appropriate size . (iii) Necessary cutting chasing shall be included in this item. (iv) One run of all Cables together shall be measured as one unit.
Supply & fix in replacement of existing unserviceable Sheet metal enclosure with new DB’s suitable for MCBs of single pole and neutral 2 way double door type with 200 amp rated bus bar. Note: i) Connnections of the MCB'S shall be done with appropriate size of brass/Cooper thimble. ii) The disturbed surface shall be match with existing shall be part of job.
S&F in replacement of existing unserviceable MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 4 ways with IP43 protection complete all as specefied and directed. Make: Indoasian, Havells, Schenider, Seimens, Legrand Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for earth
S&F MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 8 ways with IP43 protection complete all as specefied and directed. Make:Indoasian, Havells, Schenider, Seimens, Legrand Note : i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for earth
S&F in replacement of existing unserviceable MCB DB double door 240 volts with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting type, drilling holes for incoming and out going cables complete suitable for 12 ways with IP43 protection complete all as specefied and directed. Make:Indoasian, Havells, Schenider, Seimens, Legrand Note: i) Eye/bottle thimbles shall be used for connection in switches/sockets & MCB's in DB's without any extra cost ii) Electric rewiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for earth
S&F in replacement sheet metal enclosures distribution boards, double door three phase 415 volts 4 ways (one incoming three phase & four out goings three phase )for MCCB, ISOLATOR & MCB,s comprising three phase four wire copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following (a) MCCB FOUR POLE 100 AMPS AC 415 VOLTS 10 KA IHLGSF0100 =01 NO as incoming Note :- (i)The DB shall be VTPN series of MDS-LOADKONTAKT/Havells - CAT PART – DHDLVDRWGOFO04 or equivalent in Legrand/ABB/Indoasian optipro (ii) The DB shall be flush fixed ,and making good the disturbed surface matching with existing specifications shall be part of job at no extra cost.(iii)connection of theMCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped.(1v) all the vacant holes of the DB shall be provided with blank plates of appropriate size. (v) double continuous earth wire shall be provided for each three phase DB from earthing mains dolly.
Supply and fix in replacement of MCB SP up to 6-32 Amp all as specified and directed.
Supply and fix in replacement of MCB SPN 6-32 Amp complete all as specified and directed.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 10 Sqmm, 2 core complete all as specified.
Supply and fixing 1100 volts grade heavy duty cable PVC insulated stranded aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections, one twin core cable flat or circular stranded conductor size of 16 Sqmm, 2 core complete all as specified.
Supply and fix in replacement of Recess mounted LED luminaire with more light distribution and clutter free ceilings of 36 watt suitable for gridd celling Cutout dimensions: 2x2 Ft. Model - PALNO, Cat No.-145999168, Make : Havells or equivalent in Crompton/ Bajaj/ Anchor.
Supply & fix in replacement of FTL with new techonlgy LED having high efficiency of capacity LED 20 Watt, FIXT ELITE PRIDE PLUS 20 W 6500K, Cool Day Light (CDL) LHEXBLP7PN1W020. Make -Havells. incl necessary electric conection complete all as specified.
Supply & fix in replacement of LED 10 Watt, 2 feet long, Cool day light with NEO Batten10 W 6500K having high efficiency Cat No. LHEXACP7IN1W010. Make -Havells or equivalent of Crompton/ Bajaj / Anchor incl necessary electric conection complete all as specified.
Supply & fix in replacement of Mirror light with Linear & compact 9W mirror light with decorative grey end caps, polycarbonate body and ribbed opal diffuser of capacity 9 watt .
Supply & fix in replacement of angular type lamp holder, PVC/ polycarbonate type with back plate suitable for 15/18 watts for batten fitting, including plastic square board of required size complete all as specified.
Supply & fix in replacement of LED Lamp LED new Adore 7W E27 WW Ball Lamp LHLDERHEMD 8X007 7 watt. (Make -Havells or equivalent of Crompton/ Bajaj / Anchor)
Supply & fix in replacement of Call bell ding dong AC 230 volt single pole complete all as specified.
Supply & fix in replacement of Buzzer, ding Dong AC 230 volt single pole complete all as specified.
M&L for replacement of existing unserviceable earthing complete with galvanized steel earth plate electrode 600x600x6mm tthick buried directly in ground(earth plate not less than 2.25 mtr deep below the normal ground level ) with top edge of plate not less than 1.5 mtr below the normal ground level connected to galvanized earth wire 4mm dia by means of nuts bolts,washers,check nuts of iron or steel including test point PCC pits and RCC cover in PCC 1:2:4 (type B-1) including iron angle frme 40*40*6mm. and medium grade GI watering pipe 20mm dia with funnel and wire mesh and 15 mm bore GI pipe light grade proection pipe including excavation and charcoal ,common salt surrounded with 15cm all around the plate all as specified and shown in EP-3 of SSR Part-I
Supply & fix in replacement of existing unserviceable LED Bulk head fitting 10 W with Engineering plastic housing &clear prismatic diffuser, heat sink itegrated including smd LED 13W complete.
Supply & fix in replacement of LED Ceiling light 18 Watt round surface mounted die cast aluminium housing with frosted diffuser including LED lamp complete.
Supply & Fix in replacement of PVC Conduit of size 40 mm incl all connected accessories (bends, clamps, PVC union & screws etc) for existing wiring all as directed.
Supply & Fix in replacement of PVC Conduit of size 25 mm incl all connected accessories (bends, clamps, PVC union & screws etc) for existing wiring all as directed.
Supply & Fix in replacement of PVC Conduit of size 20 mm incl all connected accessories (bends, clamps, PVC union & screws etc) for existing wiring all as directed.
R D Bansal
R N Enterprises
NARINDER KUMAR SONS
m/s s.n. builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .