Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.4 LAccepted-AOC E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹38.9 L+₹10.1 L (34.8%)Rejected-Finance NOT AVAILABLE | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹43.0 L+₹14.1 L (48.8%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹45.4 L+₹16.5 L (57.2%)Rejected-Finance | L4 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
9 Sept 2021, 3:00 pmClosed
GE (NW) Navy Nagar, Colaba, Mumbai
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINT OF SUBMAIN WIRING ENERGY METERS METER CABIN AT VARIOUS BUILDINGS LIFT MACHINE ROOM AT NAVY NAGAR UNDER GE NW NAVY NAGAR COLABA MUMBAI
2021_MES_467860_1
8143/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) Navy Nagar, Colaba
Class D and Category b(i)
7 documents required · 7 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹74,000
Yes
27 Sept 2021
13 Aug 2021
10 Sept 2021
13 Aug 2021
9 Sept 2021
27 Aug 2021
13 Aug 2021 - 2 Sept 2021
Amount
Supply, install, testing and commissioning of meter cabin panel mounted on angle iron frame 40x40x5 mm grouted on floor,cubical indoor type for 415V, 3 phase, 4 wire made out of 2 mm thick CRCA sheet weather, vermin proof factory fabricated, CPRI approved, front open hinged door with locking arrangement powder coated, individual compartment for MCCBs and 200 Amps rated copper bus bar(All in equal size), top and bottom cable entry with proper size glands including disconnecting cable connections and electronic meters from old meter cabin panel and refixing the existing meter & reconnecting in new installed panel with provisions of thimble/lugs and making provisions of vision glasses for meter readings, one spare MCCB compartment, and including PCC on 1:2:4 type B-1 for fixing meter cabin at old meter cabin place complete all as specified and as directed comprising of the following :-
(a) MCCB 100A, 4 pole, 415 volt, thermal magnatic release type, Ics=100% Icu, 25 kA - 01 Nos, Cat No-4200 55 of Make-Legrand/Siemens/L&T/Schneider. (b) MCCB 63A, 4 pole, 415 volt, thermal magnatic release type, Ics=100% Icu, 25 kA-02 Nos, Cat No-4200 53 of Make-Legrand/Siemens/L&T/Schneider. (c) MCB SPN 32 Amps- 10 Nos Make-Legrand Cat No-4086 17 or eqivalent to L&T/Schnider/ABB. (d) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V, A, F, PF, KW, kVAR, kWH etc of make :- L&T, Cat Ref -WL441010OOOO-01 set or equivalent in Legrand/Schnieder/ABB. (e) Phase indicator lamp R,Y & B - (01 Set of three). (f) Copper Bus bar, 200 Amps Rated - R,Y,B & N - (01Set of four). (g) Reconnecting of submain cable 2 core 4/ 6 Sqmm copper conductor with outgoing of energy meter. (h) Making good the disturbed surface of meter cabin room if any damages occures during shifting of panel. Note :- Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
All as per Item No 1.00 above but comprising of the following :- (a) MCCB 63A, 4 pole, 415 volt, thermal magnatic release type, Ics=100% Icu, 25 kA-02 Nos, Cat No-4200 53 of Make-Legrand/Siemens/L&T/Schneider (b) MCB SPN 32 Amps- 10 Nos Make-Legrand Cat No-4086 17 or eqivalent to L&T/Schnider/ABB (c) Digital panel meter with LCD multifunction meter with CT/PT and all parameters as V, A, F, PF, KW, kVAR, kWH etc of make :- L&T, Cat Ref -WL441010OOOO-01 set or equivalent in Legrand/Schnieder/ABB. (d) Phase indicator lamp R,Y & B - (01 Set of three). (e) Copper Bus bar, 100 Amps Rated - R,Y,B & N - (01Set of four). (f) Reconnecting of submain cable 2 core 4/ 6 Sqmm copper conductor with outgoing of energy meter. (g) Making good the disturbed surface of meter cabin room if any damages occures during shifting of panel. Note :- Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
Taking down old unserviceable street light panel and supply and fix Street light panel, weather proof , vermin proof, made up of Thermoplastic Polycarbonate, front opening with individual modular combinable encloser system, Size-1100x1580x705mm, Out door type(IP-54) suitable for 3 phase, 4 wire 415 volts, 200 Amps rated copper bus bar strips with necessery clamps, nuts, bolts and washers, internally prewired with all connecting accessories , floor mounted type made with angle iron legs 40x40x4mm thick, PCC work and foundation 60cms above the ground level in PCC 1:3;6 type C2 all as specified and directed consisting the following :-
(a) Empty Box-Opaque, Make-Hensel, Type-Lid Mi 0401=1 Nos
(b) Empty Box-Transparent Lid, Make-Hensel, Type-Lid Mi 0400=1 Nos
(c) Extension Frame, Make - Hensel, Type-MiZR4 =1 Nos
(d) Empty Box-Opaque Lid, Make- Hensel, Type-Mi0201=1 No
(e) Empty Box-Opaque Hi-Lid, Make- Hensel, Type-Mi 0411= 3 Nos
(f) Empty Box-Transparent Hinged-Lid, Make-Hensel, Type-Mi0220=1 Nos
(g) Protection cover (Blue), Make-Hensel, Type-MiEP02=1 Nos
(h) Wall Gasket, Make-Hensel, Type-MiWD2=12 Nos
(j) Flange, Make-Hensel, Type-MiFP20=3 Nos
(k) Mounting Profile, Make-Hensel, Type-MiMS2=3.6 Mtrs
(l) Cable Gland (Short Entry Thread), Make-Hensel, Type-1555.20.13
(m) Lock Nut, Make-Hensel, Type-8220=2 Nos
(n) Dew Guard with fixing tape, Make-Hensel, Type-HDG 075=01 Nos & HDG 100 = 03 Nos & HDG 150=01 Nos
(p) Change Over Switch, Make-L&T, Type-CO21600OOOO=1 Nos
(q) MCCB, FP, 100A, 25 kA, Make-Legran, Cat No-420055 = 2 Nos
(r ) Rotary Handle, Make-Legrand, Cat- 420161 = 2 Nos
(s) 24 Hrs Timmer-16A(Analog)-1 Mod-QT31, Make-Legrand, Cat-412813=2 Nos
(t) Power Contactor (4NO), 63A, TP, Make-Legrand, Cat-412556 = 2 Nos
(u) LED indicating lamp (R,Y,B), Make-L&T = 3 Nos
(v) MFM 4405 LED meter CI 1 with RS485, Make-L&T, Cat-WL4405110= 1 No
(w) CT, 160/5A, 5VA, CL.1, Make-ELMEX=3 Nos
(x) Control Fuse Base, 32A, Cat-32NNSF & Control Fuse Link, 2A, Cat-NSD2,Make-Bussman = 06 Each
(y) Mounting plate(Size 4) =4 Nos
(z) Busbar with conical support & Acc=1 Set
(aa) Frame & Canopy=1 Job
(ab) Wiring Accessories, Earth strip, sleeves, Ferrules, Dinrail, Neutral Link, End clamp, Accessories etc.=1 Job
(ac) Other Misc acessories like Terminal block, End plate, end clamps = 1 Job
Taking down old unserviceable meter cabin panel and supply and fix meter cabin panel, weather proof , vermin proof, made up of Thermoplastic Polycarbonate, front opening with individual modular combinable encloser system, Size-1100x1580x705MM, indoor type(IP-54) suitable for 3 phase, 4 wire 415 volts, 200Amps rates copper bus bar strips with necessery clamps, nuts, bolts and washers, internally prewired with all connecting accessories , floor mounted type made with angle iron legs 40x40x4mm thick, PCC work and foundation 60cms above the ground level in PCC 1:3;6 type C2 all as specified and directed consisting the following :-
(a) Empty Box-Opaque, Make-Hensel, Type-Lid Mi 0401=1 Nos
(b) Empty Box-Transparent Lid, Make-Hensel, Type-Lid Mi 0400=1 Nos
(c) Extension Frame, Make - Hensel, Type-MiZR4 =1 Nos
(d) Empty Box-Opaque Lid, Make- Hensel, Type-Mi0201=02 Nos
(e) Empty Box-Opaque Hi-Lid, Make- Hensel, Type-Mi 0411= 01 Nos
(f) Empty Box-Transparent Hinged-Lid, Make-Hensel, Type-Mi0220=1 Nos
(g) Protection cover (Blue), Make-Hensel, Type-MiEP02=1 Nos
(h) Wall Gasket, Make-Hensel, Type-MiWD2=06 Nos
(j) Flange, Make-Hensel, Type-MiFP20=02 Nos and Hinged flap, Make Hensel- 02 Nos
(k) Mounting Profile, Make-Hensel, Type-MiMS2=1.8 Mtrs
(l) Cable Gland (Short Entry Thread), Make-Hensel, Type-1555.20.13
(m) Lock Nut, Make-Hensel, Type-8220=2 Nos
(n) Dew Guard with fixing tape, Make-Hensel, Type-HDG 075=01 Nos & HDG 100 = 03 Nos & HDG 150=01 Nos
(p) MCCB FP, 100A, 25KA, Make - 420055 =01 Nos
(q) MCCB, FP, 63A, 25kA, Make-Legrand Cat No-420053
(r) Terminal block (screwless type side entry) Make - ELMEX -22 Nos,disconnecting terminal block, Make - ELMEX - 03 Nos, Marking label(1-10) - 08 Nos
(s) Rotary handle, Make-Legrand, Cat No -420161=03 Nos
(t) MCB SPN 32A, Make - Legrand Cat No -412813 = 10 Nos, Looping busbar (pin type) - 02 Nos and Looping busbar (pin type) (56Mod) with end cap - 01 Nos
(u) Spreader link (Set of 4), Make - Legrand Cat No - 01 Nos and Insulated shields (set of 3), Make- Legrand - 01 Nos
(v) LED indicating lamp (R, Y, B) Make - L&T = 03 Nos
(w) MFM 4405 LED meter CI 1 with RS485, Make - L&T, Cat WL4405110 = 01 Nos
(x) CT, 160/5A, 5VA, CL.1, Make-ELMEX=3 Nos
(y) Fuse terminal block (screw type), Make - ELMEX - 6 Nos & Fuse for terminal, Make-ELMEX - 6 Nos
(z) mounting plate(Size 4) =01 Nos & (size) = 01 Nos
Busbar with conical support & accessories - 01 Set
(ab) Frame & Canopy=1 Job
(ac) Wiring Accessories, Earth strip, sleeves, Ferrules, Dinrail, Neutral Link, End clamp, Accessories etc.=1 Job
(ad) Other Misc accessories like Terminal block, End plate, end clamps =2 Job (ae) Reconnecting of submain cable 2 core 4/6 Sqmm copper conductor with outgoing of energy meter. (af) Making good the disturbed surface of meter cabin room if any damages occures during shifting of panel. Note:- Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
All as per Item No 4.00 above but comprising of the following :-
(a) Empty Box-Opaque, Make-Hensel, Type-Lid Mi 0401=1 Nos
(b) Empty Box-Transparent Lid, Make-Hensel, Type-Lid Mi 0400=1 Nos
(c) Extension Frame, Make - Hensel, Type-MiZR4 =1 Nos
(d) Empty Box-Opaque Lid, Make- Hensel, Type-Mi0201=2 Nos
(e) Empty Box-Opaque Hi-Lid, Make- Hensel, Type-Mi 0411= 1 Nos
(f) Empty Box-Transparent Hinged-Lid, Make-Hensel, Type-Mi0220=1 Nos
(g) Protection cover (Blue), Make-Hensel, Type-MiEP02=1 Nos
(h) Wall Gasket, Make-Hensel, Type-MiWD2=6 Nos
(j) Flange, Make-Hensel, Type-MiFP20=2 Nos & Hinged flap, Make-Hensel - 02 Nos
(k) Mounting Profile, Make-Hensel, Type-MiMS2= 1.8 Mtrs
(l) Cable Gland (Short Entry Thread), Make-Hensel, Type-1555.20.13 - 2 Nos
(m) Lock Nut, Make-Hensel, Type-8220=2 Nos
(n) Dew Guard with fixing tape, Make-Hensel, Type-HDG 075=01 Nos & HDG 100 = 01 Nos & HDG 050=02 Nos
(p) MCCB, FP, 100A, 25 kA, Make-Legran, Cat No-420055 = 1 Nos
(q) MCCB, FP, 63A, 25 kA, Make-Legran, Cat No-420055 = 2 Nos
(r) Terminal block (screwless type side entry), Make-ELMEX - 22 Nos, Disconnecting terminal block, Make ELMEX- 3 Nos, Marking label(1-10) - 8 Nos
(s ) Rotary Handle, Make-Legrand, Cat- 420161 = 1 Nos
(t) MCB SPN 32 A, Make-Legrand, Cat-412813= 10 Nos, Looping busbar (pin type) - 2 Nos & Looping busbar (pin type)(56mod) with end cap - 1 Nos
(u) Spreader Link (Set of 4), Make-Legrand, Cat- = 1 Nos & Insulated shields (set of 3), Make-Legrand - 1 Nos
(v) LED indicating lamp (R,Y,B), Make-L&T = 3 Nos
(w) MFM 4405 LED meter CI 1 with RS485, Make-L&T, Cat-WL4405110= 1 No
(x) CT, 160/5A, 5VA, CL.1, Make-ELMEX=3 Nos
(y) Fuse terminal block (screw type), Make - ELMEX - 6 Nos & Fuse for terminal, Make-ELMEX - 6 Nos
(z) Mounting plate(Size 4) =1 Nos & (size) = 1 Nos
(aa) Busbar with conical support & Acc=1 Set
(ab) Frame & Canopy=1 Job
(ac) Wiring Accessories, Earth strip, sleeves, Ferrules, Dinrail, Neutral Link, End clamp, Accessories etc.=1 Job
(ad) Other Misc acessories like Terminal block, End plate, end clamps = 2 Job (ae) Reconnecting of submain cable 2 core 4/ 6 Sqmm copper conductor with outgoing of energy meter. (af) Making good the disturbed surface of meter cabin room if any damages occures during shifting of panel. Note :- Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
M&L for LT FPB, weather proof made out of 2mm thick CRCA sheet, in-door type suitable for 3 phase, 4 wire, 415 volts, with copper busbar strip of suitable for, 400 amps capacity with necessary clamps, nuts, bolts and washers, internally prewired with all connecting accessories, floor mounted type made with angle iron legs 40x40x4 mm thick, powder coated painting and fixing FPB on PCC foundation of 60 cms above the ground level with PCC 1:3:6 type C2, all as specified & directed comprising of the following:-
(a) S&F MCCB 250 Amps, TPN, 35/36 kA, thermal magnetic release, Ics=100% Icu - 01 Nos, Cat No- of Make- Legrand or equivalent in C&S/Siemens/L&T/Schneider
(b) S&F MCCB 100 Amps, TPN, 16 kA, thermal magnetic release, Ics=100% Icu - 02 Nos, Make- Legrand or equivalent in C&S/Siemens/L&T/Schneider
(c ) S&F MCCB 63 Amps, TPN, 16 kA, thermal magnetic release, Ics=100% Icu - 02 Nos, Legrand or equivalent in C&S/Siemens/L&T/Schneider
(d) S&F MCB 25 Amps, DP, 10 kA, - 60 Nos, Make- Legrand or equivalent in C&S/Siemens/L&T/Schneider
(e) S&F digital VAF Multifunction meter - 01 Nos inside LT FPB. Cat No-WL411010OOOO of Make-L&T or Legrand - Each - 1
(f) S&F Phase indicator lamp R,Y & B - Set of 3 inside LT FPB. - Set of Three - 1
(g) S&F U/V coil -03 Set inside LT FPB, Cat No-422248 of Legrand. Each Set - 3
(h) S&F Din type Single Phase Meter inside LT FPB, Cat No-WD4000101OOO Make- L&T/ Legrand/C&S - Each - 60
(j) Reconnecting of submain cable 2 core 4/ 6 Sqmm copper conductor with outgoing of energy meter.
(k) Making good the disturbed surface of meter cabin room if any damages occures during shifting of panel.
Note :- Before fabrication of panel the contractor has to take approval from accepting officer on drawing.
Demolition of concrete of any description and in any position not otherwise specifically provided for including chaina mozaic, removing the debris from MD area all as directed.
Demolition of brickwork or stone/boulder masonary, built in cement morter including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles complete all as directed.
M&L Brick work with sub class 'B' brick old size straight or curved on plan exc 6 mtr mean radius built in CM 1:6.
M&L plastering 15 mm thick on other than fair faces of brickwork or concrete surface of wall in cm 1:6 and finishing the surface even and smooth without using extra cement and finally providing sagolt finish complete all as directed.
M&L framed work such as grills, grating etc with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work confirming to Fe Fe 290 Gde E-165 all as directed.
M&L applying two coats of synthetic enamel paint over a coat red oxide on steel newly surface over 10cm width/girth incl preparation of surfaces all as directed.
M&L machine cut pre-polished kota stone slab flooring 20-25mm thick over and including 15mm thick cement screed base in CM (1:6) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete.(Note : The rate includes the costof cement screed bed).
M&L applying two coats of oil emulsion distemper white or tinted on wall over a coat of primer & chalk whiting on new plastered surfaces of wall after necessary preparation of surface with putty complete all as specified.
M&L Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) 40mm thick in flooring all as directed.
Preparing new plastered surfaces of ceiling and applying two coats of oil bound distemper all as directed.
S & F Electronic meter,single phase, accuracy class 1.0, 240 v, 50 Hz, with bakelite LCD display, of rating 5-30 Amps (Measures & Display, kWh,V,kW,PF,Last month history of kWh, MD in kW) with special features like TOD, Tamper looging, Optical communication port & Display in absence of power, testing after taking out existing unserviceable meter complete all as specified. . Make : L&T Cat Part No-WM101BC5DDH or equivalent in Secure/ Havells.
S & F cable PVC insulated, PVC sheathed, armoured, FRLS, 1100V grade, 2 core 6 sqmm stranded copper conductor electric cable laid on wall/ roof/ duct complete with proper saddling and connecting to DBs with glands including taking out existing unserviceable cable complete all as specified.
M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level connected to galvanized earth strip 32 X 6mm by means of bolts, nuts and washers of galvanized iron or steel upto the test point all as shown in electrical plate No.3 of SSR Part-I connected toExisting earth strip including PCC earth pit with CI cover, GI funnel with wire mesh, GI protection pipe of 40 mm dia for earth lead and 20mm GI pipe for watering, excavation and earth work in any type of soil, filling the pit with charcoal and common salt surrounding the earth plate complete all as specified and directed by Engr-in-Charge including testing on completion.
M&L for aluminium strip 25x3.15mm with saddles and fixing screws etc. for roof conductors above ground.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 Nos 8mm dia 25mm long hex head screw
M&L scrapping old worn out paint from indoor type meter cabin panels and painting with one coats of synthetic enamel paint (incl front door in side and indl compartment outer side etc also) over a coat of primer and spray painting complete including fixing radium sticker danger sign board suitable for LT panel board all as specified and as directed by engr-in-charge.
SHREE JAGDISH FURNITURE CO.
DHARMESH ENTERPRISES
NOEL ENGINEERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .