| 1 | L1₹37.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹38.2 L+₹37,547 (0.99%)Rejected-Finance 46 HUSENI LAKDA BAZAAR 242 BELLASIS ROAD MUMBAI 400008 | MUMBAI | MAHARASHTRA | 400008 | L2 | Rejected-Finance Being other than lowest tender | |
| 3 | L3₹39.9 L+₹2.1 L (5.58%)Rejected-Finance | L3 | Rejected-Finance Being other than lowest tender | |
| 4 | L4₹40.6 L+₹2.8 L (7.29%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance Being other than lowest tender | |
| 5 | L5₹49.8 L+₹12.0 L (31.7%)Rejected-Finance NOT AVAILABLE | L5 | Rejected-Finance Being other than lowest tender |
Tender Value
₹46.5 L
EMD Value
₹93,000
Closing Date
30 Nov 2021, 6:00 pmClosed
GE (NW) KUNJALI
Garrison Engineer NW Kunjali Dr Homi Bhabha Road Navy Nagar Colaba Mumbai 400005
8423 DEMOLITION OF EXISTING SEWAGE LINE AREA DRAINAGE AND RECONSTRUCTION OF NEW LINES AT KV 03 COLABA MUMBAI AND PROVISION OF SPLIT AC QTY 06 2 TON IN NEWN SERVER ROOM DR SITE AND NETWORK OPERATION CENTRE
2021_MES_486081_1
8423/E8
Open Tender
Civil Works
Item Rate
183 days
GE (NW) KUNJALI
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹93,000
Yes
29 Jan 2022
3 Nov 2021
2 Dec 2021
11 Nov 2021
30 Nov 2021
16 Nov 2021
3 Nov 2021 - 11 Nov 2021
Amount
Excavation in trenches n. exc. 1.5m wide and n. exc. 1.50m depth for foundations etc or for shafts, wells, cesspits, manholes pier holes etc n.exc 10 Sqm on plan and n.exc 1.5 m in depth and getting out any type of soil complete all as specified and directed.
Excavation over areas n.exc 1.5 m deep and getting out in any type of soil complete all as specified and directed.
M & L for Hardcore of broken stone or boulder of guage n exc 63mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast con-crete articles complete all as specified and directed.
Demolition of cement concrete in ground floors and pavings n.exc 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for cement concrete 1:3:6 type C-2 (using 40 mm graded stone agg) as in foundations, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:4:8, type D2 ( using 40mm graded stone aggregate) in foundation etc. complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 (using 20 mm graded stone agg) as in surface channels and drains complete all as specified and directed.
M&L for brick work with sub class 'B' bricks strainght or curved on plan exc 6 m mean radius built in CM 1:4 complete all as specified and directed.
M&L 150 mm dia (Internal diameter of pipe in mm) salt glazed stoneware drain pipes laid in trenches and jointed including demolition and breaking up existing drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar all as specified & directed.
M&L 150 mm bore (Bore of pipe in mm) reinforced concrete pipes, class NP-2 laid and jointed complete with collars including demolition and breaking up existing drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar all as specified & directed.
M&L 200 mm bore (Bore of pipe in mm) reinforced concrete pipes, class NP-2 laid and jointed complete with collars including demolition and breaking up existing drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar all as specified & directed.
M&L 300 mm bore (Bore of pipe in mm) reinforced concrete pipes, class NP-2 laid and jointed complete with collarsincluding demolition and breaking up existing drain pipes (Salt glazed ware, AC or reinforced concrete) set in cement mortar all as specified & directed.
M&L for concrete bed in cement concrete 1:3:6 type C-2 (using 40 mm graded stone agg) to drain pipes 150 mm bore (Bore of pipe in mm) including packing under, and haunching against the sides of pipes after they are laid and tested all as specified and directed.
M&L for concrete bed in cement concrete 1:3:6 type C-2 (using 40 mm graded stone agg) to drain pipes 200 mm bore (Bore of pipe in mm) including packing under, and haunching against the sides of pipes after they are laid and tested all as specified and directed.
M&L for concrete bed in cement concrete 1:3:6 type C-2 (using 40 mm graded stone agg) to drain pipes 300 mm bore (Bore of pipe in mm) including packing under, and haunching against the sides of pipes after they are laid and tested all as specified and directed.
Taking down cement or cement lime plaster, any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc including all necessary scaffolding as required and rubbishing off the premises etc complete all as specified and as directed..
M&L for Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc all as specified,
M&L for Providing plain cement concrete type B-1, 1:2:4 (using 20 mm graded stone agg) as in lintels upto 1.5 M clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, roof kerbs water troughs and the like including weathering slightly rounded or chamfered angles and throating as directed.
M&L for 100 mm thick cement concrete 1:4:8, type D-2 (40 mm graded stone agg) as in sub base complete all as specified and directed.
M&L 100 mm thick cement concrete type B-1, 1:2:4 (20 mm graded stone agg) as in hardstanding laid in alternate panel complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm in hard/dense soils complete all as specified and directed.
Removing demolished materials/soil outside MD land to a distance exc 5KM complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified.
S&F mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar; barred iron doors; ladder; framed balusters; walkj ways, railings, frame work for water tanks and similar work conforming to Fe 290 Gd E-165 all as specified .
M&L for Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes gate stops, parts of ranges, balusters and similar articles exc 5 Kg Each all as specified.
M&L for Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions complete all as specified. (Water proofing compound to be measured and paid for separately).
Supply only integral water proofing compound complete all as specified.
Taking down eaves gutters and PVC rainwater pipes (any size or pattern) incl all fittings, heads, shoes, bends, swanecks etc incl cleaning or refixing or removal to store (measured overall as fixed along the centre line over fittings and accessories).
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including fixing clips, bends, elbows, shoes etc complete all as specified and as directed.
S&F 75 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed.
M&L for preparation of newly steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying three coats of white wash on wall complete all as specified and directed.
S&F RCC precast drain covers of size 600 x 900mm with suitable thicknes complete all as specified & directed.
M&L for reinforced cement concrete type B-1, 1:2:4 (using 20 mm graded stone agg) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including form work all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and incl mild Steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified.
Supply, install, Test and commissioning wall mounted inverter Split type AC 2.0 TR capacity units indoor/outdoor complete with cordless remote control unit, 220-240 volt, 50Hz, single phase fitted with high quality rotary compressor air ioniser and Plasma filter for better indoor air quality with 5 star rating including inbuilt of voltage stabiliser complete all as specified and as directed. Make: Voltas/Hitachi/Mitsubishi/ Blue star Notes:- (i) Rate of supporting brackets for outdoor units is deemed to be included in rate quoted. (ii) Supply and fixing copper tubings of appropriate dia for suction line and for liquid discharge line duly insulated with suitable insulation material including making hole in wall for passing though pipe and making good distrubed surface also deemed to be included in this item.
All as per Srl item No. 37 here in before but AC 1.5 TR capacity
S & F modular power socket 25A, 2 module, 25A plug top, 25A mini MCB 'C' series 3KA including 4 module box with cover plate complete all as specified and directed. Make: Anchor/ Roma/ Crabtree SAP code : ACNKCXW253, DCTNCSPA025, ACAGXXW253, ACVPPCWV03, ACTXPIWX03 respectively
S & F in replacement 20 Amps Single pole and neutral enclosure with a Two Pin and earth plug and socket complete with one single pole MCB and making connections complete all as directed. Make -Legrand Cat Part No. 5078 14 or equivalent in Siemens /GE/ C&S
S & F and clamping jointing copper tubing for suction line and for liquid discharge incl duly insulated with suitable insulation material including making hole in wall for passing through amd making to the disturb surface complete all as specified and directed.
M & L Submain wiring with two run 4 Sqmm single core multistranded PVC insulated & unsheathed copper conductors 1100 volts FRLS grade ISI make drawn through & including PVC non metallic casing and capping with Accessories fixed on wall/ceiling/truss etc including one run PVC insulated & unsheathed multistranded copper conductor 4Sq. mm FRLS grade ISI make as earth continuity conductor connected to common earth as earth dolly /mains, with all accessories like PVC elbow, PVC tee, etc including making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex/plaza/Gloster (c) Caping casing make : Asian/madi/Precision/National
M&L for sub-main wiring with 3 runs of 10.0 sqmm copper conductor cable (FRLS grade), 1100 volts grade PVC insulated and unsheathed multi-stranded, drawn in and including heavy grade non metallic PVC conduit not less than 25mm dia (internal width) with all accessories like tees, elbows, junction boxs, reducer etc as required, including 2 run of 6.0 sqmm dia PVC insulated unsheathed copper conductor cable as earth dolly/mains, with all accessories like PVC elbow, PVC tee, etc including taking up/down old unservucable sub main wiring and making good the distrubed surfaces/location complete all as specified and directed. Note: (a) Colour coding shall be followed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Make of wire : Polycab/ Havells/ Finolex / Plaza
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 12 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 5076 42 or equivalent Cat part in Siemens/C&S
S & F in repair Distribution Board double door, prewired type, made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 54 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as directed. Make - Legrand cat No 5076 40 or equivalent Cat part in Siemens/C&S
S & F MCB 6 to 32 Amps capacity, C Curve type suitable for 240 volts AC supply, SP with over load and short circuit protection and rupturing capacity not less than 10 KA including making connection complete all as specified and directed. Make: Legrand cat No 4085 87-95 or equivalent Cat part in Seimens/C&S.
S&F MCB Triple Pole 40-63Amps, 10KA 'C' Curve 415V complete all as specified and directed. Make: Legrand cat No 4086 59-61 or equivalent Cat part in Seimens/C&S.
S&F for Rigid non-metallic PVC conduit 20mm dia with complete of all tees, bends, elbows, reducers, mouth tube ends fixing accessories such as GI saddles, full threded screws and (Narayan) nylon rawl plugs etc surfaced on walls/roofs all as specified and as directed
Unitech Enterprises
Bright Construction Co
S S ENTERPRISES
SHREE JAGDISH FURNITURE CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .