Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.5 LAccepted-AOC 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹28.9 L+₹20,316 (0.71%)Rejected-Finance III 6 7 2ND FLOOR ABOVE BANK OF BARODA GOPINATH BAZAR DELHI CANTT 110 010 | DELHI CANTT | NEW DELHI | DELHI | 110010 | L2 | Rejected-Finance NOT BEING LOWEST |
Tender Value
₹26.5 L
EMD Value
₹53,000
Closing Date
12 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CHIEF ENGINEER CG GOA
HQ CE CG GOA, Chicolna, Bogmalo 403806
PROVISION OF PASSENGER LIFT (TWO PASSENGERS) FOR CGOMA AT SECTOR-24, NOIDA
2023_MES_592790_2
83021/E8
Open Tender
Miscellaneous Works
Item Rate
2280 days
AGE (I) CG Noida
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
AGE (I) CG Noida
₹53,000
Yes
4 Aug 2023
15 Jun 2023
15 Jul 2023
15 Jun 2023
12 Jul 2023
23 Jun 2023
Amount
PHASE I
Cutting opening, through brick wall built in cement mortar through brick wall for door and removing rubbish off the premises of MOD land complete all as specified and directed.
M&L for forming jambs, etc to openings (to foregoing item)with S cement mortar 1:4 inclduing cutting, toothing and porperly bonding into old work also facing, jointing and pointing to match existing work complete all as specified and directed.
M&L for making good under cills or heads of openings in Cement S mortar 1:4 including pinngin when necessary complete all as specified and directed.
Excavating in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed.
Removing excavated soil n.exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
Retruning, filling in, including spreading, levelling watering and well ramming in layers not exc 25cm in soft/loose soil complete all as specified and directed.
M&L for Cement concrete (1:4:8) type D-2 using 40mm graded stone aggregate as in foundation filling as mass concrete complete all as specified and directed.
Demolition cement concrete (unreinforced) in ground floors and paving n exc 15 cm thick and incl removing the demolished material out of MOD land complete all as specified.
M&L for 25 mm thick PCC (1:2:4) type B0 using 12.5 mm graded aggregate as in floor to receive floor finishes etc.complete all as specified and directed.
S&F vitrified ceramic dark shade coloured tiles 10mm thick (square/rectangular) polished, area of each tiles n. exc 0.36 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15 mm thick screed bed in cm 1:6 complete all as specified and directed.
Taking down cement plastering of brick or concrete surfaces including raking out joints, hacking for key, scrubbing down with water complete complete all as specified and directed.
M&L for 5mm thick rendering for backing of granite tiles in CM 1:3 on fair faces of brick work or concrete surfaces complete all as specified and directed.
M&L for 10mm thick rendering for backing of granite tiles in CM 1:3 on fair faces of brick work or concrete surfaces complete all as specified and directed.
M&L for 20mm thick Granite work tiles machine cut, in dado laid over cement screed and jointed with Granite epoxy/silicone glue including grinding and polishing complete all as specified and directed.
Design, Supply ,install, testing and commissioning of vaccum operated passenger lift for 02 passengers (capacity 210 Kg) in the existing space of staire case area, speed 0.15 M/s, lift with single phase power supply 230 Volts, power consumtion 3.7 KW Max load capacity 210 Kg, indoor type only, integrated with sound proof,unbreakable polycarbonate glass (250 times stronger than normal glass) suitable to serve G + 02, stop-03 with the following specifications :- (a) Minimum head room - 2837 mm (b) Shaft diameter - 900 mm (c) Cabin diameter - 853 mm (d) Cabin Height - 2000 mm (e) Clear door opening - 600 mm (f) Landing door height - 2000 mm The vaccum elevatore enables the following features :- (a) over load indicator in cabin. (b) Panic alarm button (c) Emergency telephone (GSM) (d) LED light and DC Fan (e) Emergency lowering button (f) COP display switch in cabin Confirming to European standard of machine directive 2006/42/EC. Complete all as specified and directed.
Supply and fix UPS for 30 min back up three phase AC input 300 to 450 V and output single phase AC out put voltage 230 V + 1% of capacity 7.5 KVA. complete all as specified and directed.
Supply, laying and testing of LT UG cable, XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 2 core complete all as specified and directed. Note :- Earth work (Excavation, Returnign & refilling and removal), sand cushioning, cable protection cover, GI protection pipe shall be measured and paid for seperately under respective item of Sch 'A'.
Supply and fixing of Sheet metal enclousers for DB'S when MCBs to SPN DB 8 Way be used Single pole & neutral with 200 amps rated bus bar Double Door 240V complete all as specified and directed.
Supply and fix RCCB of 2 pole, 40 Amp rating with sensitivity of 30 mA suitable for 240 volts complete all as specified and directed.
Supply and fixing SPN 32 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply and fixing SP 6 To 32 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Material and labour for earthing with steel earth plate electrode of size 600x600x6mm thick buried directly in ground to a depth not less than 2.25 mtr deep below normal ground level with top edge of the earth plate not less than 1.5 mtr deep below normal ground level connected to galvanized iron wire 4mm as eathing lead by means of nuts, bolts, and washers of steel. GI medium grade pipe 20mm bore protection pipe upto test point, 15mm dia GI light grade watering pipe with funnel and wire mesh, RCC pit cover of size 300x300x40mm reinforced with XPM having weight not less than 4 kg/sqmm including 6mm thick MS bar handle made to shape, PCC pit with 1:3:6 type C1 with angle iron frame made of angle iron of size 40x40x4mm, adequate qty of carcoal dust and salt layers all around the earth plate, excavation, earth work in any type of soil, removal of excavated soil and returing filling in all as required at site complete all as specified in plate No 3 of SSR Pt-I and all as specified or indicated including testing on completion. Note :- Rates inclusive of necessary excavation in any type of soil, earth work, PCC pit, RCC cover, funnel with watering pipe, GI earth strip upto 7.5 Mtr long for connecting to test point etc. All as requied at site for complete earthing complete all as specified and directed.
M & L for good quality dry sand cushinoning to under ground electric cable on layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of MES Schedule Pt-I (2009) thickness shall be measured and paid complete all as specified and as directed.
Supply and Laying sub class 'B' bricks of old size (230 x 115 x 75 mm) or of size locally available, laid along alingment of cable as protection to cable in trenches complet all as specified and as directed.
Cutting the tarmac/hard standing and excavating in trenches across the road for laying cable including making good the excavated portion by means of PCC 1:3:6 type C-1 matching with the surroundings complete all as specified and as directed.
PHASE II Comprehensive mainenance of VACCUM OPERATED ELEVATOR (1 No) 2 passenger lift (230 Kgs) passengers to serve G+2 floors complete including attending the following services to lifts all as mentioned vide Note-1 complete all as specified and directed :- (i)This phase will start after completion of phase-I (ii) Final bill of this phase prepare separately.
Comprehensive maintenance of Lift including perodic routine service,complaints,damages,reapir,replacement during the defect liability of lift complete all as directed.
Comprehensive maintenance of Lift including perodic routine service,complaints and extended warranty on parts of lifts complete incl all electrical and mechanical components shall be replaced /repaired free of cost complete After the defect liability of lift complete all as directed all as directed.
Note-1 (i) Comprehensive maintenance consists of preventive and breakdown services including repair and replacment of all consumables like topping of gear oils/grease/door rollers etc and any hardware including rewinding of motor etc and load testing of lift for satisfactory performance once in a year complete and rate quoted by the tenderer includes the following (ii) Preventive maintaince consists of carrying out routine check by skilled personnel deputed by OEM as specified in Particular specifications and as recommended by Engineer-in-Charge and lubricating to all moving parts,topping up of oils as per Lubrication chart. (iii) Breakdown maintaince consists of attending to the faults that may occur and carrying out necessary repairs/replacement to electrical control circuits and electrical/mechanical components of the lift that may occur during the operation. (iv) Fortnightly,monthly,quarterly,halfyearly and yearly maintaince registeres shall be maintained and signed by site engineer and contractor. (v) Load testing shall be arranged by the contractor to the Lift for whose repairs were carried out as and when directed by Engr-in-charge. (vi) Any delay in attending breakdown will attract penalty @ Rs 500 for first 8 to 16 Hrs after receiving complain and @Rs 1500 for every 24 Hrs of delay in rectification of complain. (vii) Payment will be released only after successull completion of maintenance as per schedule described here in before and submission of record signed by all concern persons Note-2 The contracto has to submit the AMC agreement with the OEM before the completion of defect liability period for commencement of item no.2.02 above
MB Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .