Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance 1 39A KATTUR POOLAMPATTI PO EDAPPADI TK SALEM DISTRICT 637107 | EDAPPADI | SALEM | TAMIL NADU | 637107 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹68.8 L
EMD Value
₹68,750
Closing Date
9 May 2023, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Commissioner
Salem City Municipal Corporation, Fort Main road, Salem
Supply and Fixing of 100mm and 150mm DI distribution line
2023_MAWS_306060_1
E3 / Est.No 300 / ws / 2022-2023
Open Tender
Miscellaneous Works
Lump-sum
180 days
Salem City Municipal Corporation
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹68,750
Yes
10 May 2023
25 Apr 2023
10 May 2023
25 Apr 2023
9 May 2023
25 Apr 2023
Amount
Labour for B.T Road cutting open road for laying water mains or sewer
Earth work excavation and Depositing on Bank with initial Lead of 10m and Lift of 2m in Narrow Trenches for Laying of Pipes for Water Supply and Sewerage Works in the Hard stiff clay, stiff black cotton, hard red earth, shales, murram gravel, stoney earth and earth mixed with small size boulders and hard gravelly soil.SS20B (TWAD SR P.No.270.Item No.I(b))
Testing of pipes with hydralic testing equipement by filling with water (including cost of water @ Rs.60/KL)and testing to recommand preesure in convenient straches and conveying, loading,unloading and transporation to the site etc, Complete
Up to 125 mm
Over 125 mm up to 250 mm
Supply and Delivery of the following Water Supply Specials etc., complete.
250mm Dia DI Pipe (K7)
200mm Dia DI Pipe (K7)
150mm Dia DI Pipe (K7)
100mm Dia DI Pipe (K7)
150mm dia CI Sluice Valves To Pressure Rating Of 1.6 PN To Be Used In Pump Houses (Long Body/ Long Face To Face)Conforming To Is.
150mm dia DI flange socket Tail Peace
100mm dia CI Sluice Valves To Pressure Rating Of 1.6 PN To Be Used In Pump Houses (Long Body/ Long Face To Face)Conforming To Is.
100mm dia DI flange socket Tail Peace
250mm dia CI Sluice Valves To Pressure Rating Of 1.6 PN To Be Used In Pump Houses (Long Body/ Long Face To Face)Conforming To Is.
250mm dia DI flange socket Tail Peace
400mm dia CI Sluice Valves To Pressure Rating Of 1.6 PN To Be Used In Pump Houses (Long Body/ Long Face To Face)Conforming To Is.
400mm dia DI flange socket Tail Peace
DUCTILE IRON SPECIALS AS PER IS 9523/2000 (100mm - 450mm dia)
250mm DI Bend 90 Deg.
100mm DI Bend 90 Deg.
150mm DI Bend 90 Deg.
150mm dia DI flange Tee
150mm dia DI flange socket Tail Peace
150mmx100mm dia DI flange Reducer Tee
150mm dia DI flange socket Tail Peace
100mm dia DI flange socket Tail Peace
250mmx150mm dia DI flange Reducer Tee
250mm dia DI flange socket Tail Peace
150mm dia DI flange socket Tail Peace
400mmx250mm dia DI flange Reducer Tee
400mm dia DI flange socket Tail Peace
250mm dia DI flange socket Tail Peace
350mmx200mm dia DI flange Reducer Tee
350mm dia DI flange socket Tail Peace
200mm dia DI flange socket Tail Peace
200mmx150mm Dia DI Reducer
250mm Dia DI End Cup
200mm Dia DI End Cup
150mm Dia DI End Cup
100mm Dia DI End Cup
Tyton Rubber Gaskets (for Internal Dia)
250mm Dia
200mm Dia
150mm Dia
100mm Dia
16 mm dia x 65 to 90 mm length fully threaded bolts and nuts with 2 Nos.
a).Jointing C.I/ D.I-S/S pipes and specials with rubber gaskets (tyton joint) including cost of lubricants. (including cost of jointing materials)
100 mm dia C.I/ D.I-S/S pipes and specials
150 mm dia C.I/ D.I-S/S pipes and specials
200 mm dia C.I/ D.I-S/S pipes and specials
250 mm dia C.I/ D.I-S/S pipes and specials
b).Lowering of D.I Pipes and specials in the trenches and laying to proper grade and alignment and as directed by the TWAD Officers.
100 mm dia D.I Pipes and Specials
150 mm dia D.I Pipes and Specials
200 mm dia D.I Pipes and Specials
250 mm dia D.I Pipes and Specials
a).Towards Labour Charges for Fixing of DI specials for Interlinking distribution line to existing main line (Including B.T road cuttuing, earth work and cutting charges) etc., complete.
b).Towards Labour Charges for Fixing of sluice valve with specials (Including B.T road cuting earth work, rubber sheet) etc., complete.
100mm dia CI Sluice Valves
150mm dia CI Sluice Valves
250mm dia CI Sluice Valves
400mm dia CI Sluice Valves
Refilling with excavated earth (other than Sand) Complying with the Standard Specification for Foundation and Basement including all cost and conveyance etc., complete (TWAD SR P.No.265.Item No.19(b))
Barricading work (Where, there is less traffic areas and broader roads etc.) for laying of pipe line using casurina poles at 1.50m center to center (8cm to 10cm dia and 1.80m height)
SWETHALAKSHMI ENGINEERING
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .