| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-AOC | L1 | Accepted-AOC The L1 bidder is techno-commercially eligible and the rate quoted is reasonable and justified, which has been accepted by the Competent Authority, NK Area. | |
| 2 | L2₹2.2 L+₹10,717.90 (5.18%)Rejected-Finance MAHAVIR NAGAR BUKBUKA KHALARI DISTT RANCHI JHARKHAND 829205 | RANCHI | JHARKHAND | 829205 | L2 | Rejected-Finance L2 | |
| 3 | L3₹2.4 L+₹30,366 (14.7%)Rejected-Finance ANAND NAGAR KAMRE RATU DISTT RANCHI JHARKHAND 835222 | RANCHI | RANCHI | JHARKHAND | 835222 | L3 | Rejected-Finance L3 |
Tender Value
₹2.2 L
EMD Value
₹2,900
Closing Date
17 Feb 2024, 5:00 pmClosed
SO EnM NK
GM OFFICE, NK AREA
Repairing of electrical wiring of Sub-station building at Old Sub-station and new Sub-station of KDH OCP, NK Area
2024_CCL_300621_1
GM (NK)/EnM/e-NIT/2023-24/ 244
Open Tender
Electrical and Maintenance Works
Item Rate
14 days
KDH OCP, NK Area
As per NIT
2 documents required · 2 mandatory
₹2,900
4 Apr 2024
7 Feb 2024
19 Feb 2024
7 Feb 2024
17 Feb 2024
7 Feb 2024
7 Feb 2024 - 13 Feb 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. Group A
Wiring for light / power plug with 2x4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc as required. 5/6 amps switch
Supplying and fixing following piano type switch / socket on the existing switch box / cover including connections etc as required. 3 Pin 5/6 amp socket outlet.
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 and 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box / wooden block including connection etc as required.
Supplying and fixing brass batten / angle holder including connection etc as required.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required 2 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required 2 x 6 sq. mm
Providing and fixing following rating and breaking capacity and pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections etc as required. 100 Amp, 16 KA, TPMCCB.
Supplying and fixing DP sheet steel enclosure on surface / recess along with 25/32 amps 240 volts “C” curve DP MCB complete with connections, testing and commissioning etc. as required.
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 mtrs long etc etc. with charcoal/coke and salt as required.
Providing of Exhaust fan 450 mm sweep
Providing of LED Tubelight 20 Watt
Fixing charge of Item No. 14 & 15
Total impact of GST for the purpose of CTC
M/S NIRAJ ELECTRICALS
M/S SHRI RAM ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .