| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹46.2 LAccepted-AOC 274 A 5TH LANE NISHATGANJ LUCKNOW UP PIN 226007 | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226007 | ₹46.2 L Quoted ₹48.2 L | 1 | Accepted-AOC Acceptance Of Tender |
| 2 | 2₹59.4 L+₹11.2 L (23.3%)Rejected-Finance SA 15 144 S 1 CHANDAN HERITAGE HAVELIA CHAURAHA SARNATH VARANASI U P 221007 | VARANASI | VARANASI | UTTAR PRADESH | 221007 | ₹59.4 L+₹11.2 L (23.3%) | 2 | Rejected-Finance Not L1 |
| 3 | 3₹64.4 L+₹16.2 L (33.6%)Rejected-Finance | ₹64.4 L+₹16.2 L (33.6%) | 3 | Rejected-Finance Not L1 |
| 4 | 4₹70.3 L+₹22.2 L (46.0%)Rejected-Finance 67 KAILASH VIHAR TIWARIPUR BAGIA JAJMAU KANPUR 208010 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208010 | ₹70.3 L+₹22.2 L (46.0%) | 4 | Rejected-Finance Not L1 |
| 5 | 5₹74.8 L+₹26.7 L (55.3%)Rejected-Finance 72 USMAN ENCAVE SECTOR O ALIGANJ LUCKNOW 226004 UP | LUCKNOW | LUCKNOW | UTTAR PRADESH | 226004 | ₹74.8 L+₹26.7 L (55.3%) | 5 | Rejected-Finance Not L1 |
Tender Value
₹90 L
EMD Value
₹1.8 L
Closing Date
16 Feb 2024, 6:00 pmClosed
CWE LUCKNOW
HQ CWE Lucknow, 229 MG Road, Lucknow Cantt, Lucknow-226002
REP / MAINT / REPLACEMENT OF LT PANEL BOARD LT SWITCH GEAR FEEDER PILLAR BOXES AND REP / MAINT / REPLACEMENT OF STREET LIGHT HIGH MAST LIGHT FLOOD LIGHT GATE LIGHT FOCUS LIGHT AREA OF AGE E/M (HOSP) UNDER GE E/M LUCKNOW
2024_MES_637268_1
CWE/LKO/EM/T-113 OF 2023-24
Open Tender
Civil Works
Item Rate
180 days
LUCKNOW
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE EM Lucknow
₹1.8 L
Yes
13 Mar 2024
12 Jan 2024
23 Feb 2024
12 Jan 2024
16 Feb 2024
2 Feb 2024
12 Jan 2024 - 2 Feb 2024
Amount
Supplying and laying or fixing in replacement, jointing and testing LT under ground electric power cable crossed linked polyethylene ( XLPE) insulated, galvanised steel strip or wire armoured, ISI-7098 Marked, with aluminium conductor multi stranded , heavy duty 1100 Volts grade of size 10 sqmm cross sectional area, 2 core ,complete all as specified laid in trenches/ laid under floor or fixed naked with walls / on poles/ in ducts /in GI pipes etc. with and including MS Clamps, nuts , bolts, washers complete all as specified and directed. Note :- Excavation, earth work, sand cushioning, protection bricks/ tiles/ block and pipe shall be measured and paid separately under appropriate items.
- do - but of size 10 Sqmm 4 core
- do - but of size 16 Sqmm 2 core
- do - but of size 16 Sqmm 4 core
- do - but of size 25 Sqmm 3.5 core
- do - but of size 25 Sqmm 4 core
- do - but of size 50 Sqmm 3.5 core
- do - but of size 95 Sqmm 3.5 core
- do - but of size 150 Sqmm 3.5 core
- do - but of size 185 Sqmm 3.5 core
- do - but of size 240 Sqmm 3.5 core
S & F in replacement GI Pipes galvanized, “light grade ” laid in trench complete including fittings 80 mm dia for protection for LT Cable.
S & F in replacement Pipes galvanized, “light grade ” laid in trench complete including fittings 50 mm dia for protection for LT Cable.
S & F in replacement Pipes galvanized, “light grade ”, laid in trench/or fixed on pole complete including fittings 40 mm dia.protection for LT Cable.
M&L for PCC 1:2:4 type B0 12.5 mm graded agregrate as in foundation in coping in foundation of pole including necessary form work complete all as specifies and directed.
M& L for fabrication and fixing canopy headed junction box suitable for LT Pole made out 3.15 mm MS sheet of size 30x25x15 cm with cover ,04 nos aluminium bus bar of size 25x3 mm for phase and neutral 01 nos 06 Amps MCB SP mounting channel for control street light cable gland aluminium lug MS FIixing clamp -02 nos with nut bolt washer painting with two coat of synthectic enamel paint over a coat of red oxide primer on external and internal surface complete all as specified and directed
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, pipes etc. and getting out including trimming the sides and forming bottom surfaces to required levels in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, and well ramming in layer not exceeding 25 cm thick in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils) not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed . Note :- Punned thickness shall only be considered for payment
M&L for laying well burnt old size bricks, sub class "B" bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Supply, fixing, connecting and testing energy efficient LED blolard light of 18 Watt including foundation work with PCC as required all as specified and directed.
Supply, fixing, connecting and testing energy efficient LED Garden landscape view LANTERN WITH SYMMETRIC LIGHT DISTRIBITION AND LIMITED UPWARD LIGHT COMPONENT light of 18 Watt complete all as specified and directed.
Material & Labour for preparation of old painted surface of steel tubular pole 9 meter long above coping) and applying two coat of aluminium paint, making of strip of 20 cm width (BLACK and white in alternate band) upto 1400 mm height with one synthetic enamel paint , rewriting pole No by painter with enamel paint, and painting the existing MS clamp with one coat of aluminum paint complete all as specifeid and directed.
Material and labour for writting of Pole Nos on existing pole with stencil out with white colour in BLACK background of 80 mm hight around the radius of pole and all as specified and directed by Engr in charge.
M&L for Spray painting of LT pannel off size structure including cross arms,chanel etc complete structure after scraping old paint with two coats synthetic aluminium paint after applying one coat of zinc oxide primer complete all as directed by Engr-in-Charge
S & F in repairs MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 100 AMPS
S & F in repairs MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 125 AMPS
S & F in repairs MCCBs four pole 16 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 160 AMPS
S & F in repairs MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 200 AMPS
S & F in repairs MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 250 AMPS
S & F in repairs MCCBs four pole 36 KA, fixed type incl taking out unserviceable MCCB's and connecting,of capacity 400 AMPS
S & F in repairs Power contactor 4 pole Type Mcx 32 , Fr size 2 rating AC 1 rating 160 A, 50HZ including dismantling the unserviceable contactor, complete all as specified and directed.
S & F in repairs Power contactor 4 pole Type Mcx 23 , Fr size 1 rating AC 1 rating 40A, 50HZ including dismantling the unserviceable contactor, complete all as specified and directed.
Supply & fixing in replacement MCCB Four Pole 630 Amp,36 kA, 415 volts 'B' curve complete all as specified
S & F Offload change over switch, 200 Amps, 415 volts, 4 pole in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all specified & directed
S & F On load change over switch, 63 Amps, 415 volts, 4 pole side handle type in sheet metal enclosure conforming to IS:13947 (Part-3); IEC:60947-3 with locking facility including all connecting/ jointing materials and dismantling of existing change over switch, complete all specified & directed.
S & F Off load change over switch (side operated handle) 400 Amps, 415 volts 4 pole in sheet metal enclosure with interlock door and pad lock facility including dismantling of existing change over switch, complete all specified & directed.
S & F in repairs street light panel single phase up to 6 kw load with Astronomical digital timer and MCCB of capacity 32 / TP and SPN 40 Amps fixed on wall/pole with clamps,nutbolts all as specified and directed.
Restreching only existing LT OH lines consisting following lines of ACSR and GI wire , any size and tightening with aluminium binding wire 4 Lines of ACSR and 1 line of GI wire complete all as specified and directed. Note :- (i) Linear length centre to centre of the poles shall only be measured (ii) Cleaning / pruning of tree branches falling around the conductor shall also deemed to be included in the quoted rates
Supplying and fixing in repair flat twin core ,1.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified.
Supplying and fixing in repair flat twin core ,2.5 sqmm nominal cross sectional area multistranded aluminium conductor cable, over all PVC sheathed, 1100 Volts grade heavy duty cable PVC insulated and PVC sheathed complete all as specified.
Supplying and fixing in repair flat twin core ,6 sqmm nominal cross sectional area multistranded aluminium conductor FRLS cable, PVC insulated and sheathed 1100 Volts grade complete all as specified.
S & f Straight through joints (Heat Shrink Kits ) for 3.5 core cable 25 to 50 Sq mm for LT underground cable indoor/outdoor type complete for Armoured ,PVC sheathed Aluminium conductor cables Including excavating earth, identifying the fault, making proper joint of cable after rectification & returning soil back to earth, complete all as specified and directed.
All as per item No 44 above but 3.5 core cable 70 to 150 Sq mm
All as per item No 44 above but 185 sqmm to 300 sqmm 3 ½ core
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint including taking down of old pole complete all as specified and directed. Note -Old pole will be deposited in MES store yard
M&L Earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI strip 32 x 6 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS TMT bars 8mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
M & Labour for tracing out LT Cable fault of any size any Location in the area of the AGE E/M hospital by cable fault fault locater Machine and mark location , Excavation for Joints and refilling removal all as directed by EIC. Note - Joint Will be measure and paid respective Item.
Supply and fixing in repair Integral dome type white coloure plastic boty of size 300 mm suitable for fixing on 80 mm pipe post top lanterns including suitable for 1x25 W CFL including making connections complete all as per specified and directed by the Engr-in-Charge.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 80 mm bore complete all as specified.
Dismantling and removing existing unsv LED ight any type / street light/ flood light MH/HPSV fittings of any type and any capacity from street light poles any hieght and high mast light pole after disconnecteing of electrical connection complete all as specified and directed.
Supply, fixing, connecting and testing energy saving LED street light fittings 35 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Supply, fixing, connecting and testing energy saving LED street light fittings of 60 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed
Supply, fixing, connecting and testing energy saving LED street light fittings of 70 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed
Supply, fixing, connecting and testing energy saving LED street light fittings of 90 Watt with thermal management, potted driver, pressure die cast housing LM 6 alloy/anti dust exposed lens, in built tilt angle arrangement and environment friendly long life with IP66 protection on existing street light poles and bracket complete all as specified and directed.
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 70 Watt pressure die cast aluminium housing and IP66 protection complete all as specified and directed.
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 100 Watt pressure die cast aluminium housing and IP66 protection complete all as specified and directed.
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 120 Watt pressure die cast aluminium housing and IP66 protection complete all as specified and directed.
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 170 Watt pressure die cast aluminium housing and IP66 protection complete all as specified and directed.
Supply, fixing, connecting and testing energy efficient LED flood light fittings of 210 Watt pressure die cast aluminium housing and IP66 protection complete all as specified and directed.
Supply and fixing post top lantern LED type 20 watt 230 volts AC outdoor type with decorative post top for 360 degree indiret light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete
Supply and fixing post top lantern LED type 40 watt 230 volts AC outdoor type with decorative post top for 360 degree indiret light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete
S&F in replacement GI bracket for street light fittings fabricated with GI tubing 40mm dia 'light grade' 1.5m long and bending to angle of 120 degree including mild steel clamp of suitable size with two coat aluminium paint suitable for fixing on PCC/steel poles complete all as specified and directed.
M/s A.K Construction
AIRCON SYSTEMS
Ashirwad Contractor and Supplier
Unnati Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .