GE AF NAL
GE AF NAL
AS DESCRIBED IN BILL OF QUANTITIES
2023_MES_600061_1
GE (AF) NAL/T-33/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
243 days
GE AF NAL
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE AF NAL
₹56,000
Yes
11 Aug 2023
1 Jun 2023
29 Jun 2023
1 Jun 2023
27 Jun 2023
15 Jun 2023
1 Jun 2023 - 10 Jun 2023
Amount
Supply & fix in repair Flame proof Arial flow fan 450 mm sweep (exhaust fans) complete with flame proof motor .25 HP AC single phase 230/ 240 V including all fixing arrangement in wall including wire mesh at inside and damper at out side with handle for operation complete.
Supply & fixing in repair LED 1x20 watt FLAME PROOF tube light fixture luminaire including integral reflector made of diecast alluminium alloy LM6 , with electronic ballast, bipin holders, .connector block, etc., and all accessories pre-wired and including connecting up with suitable size copper conductor twin core cable complete.
S&F in repair Flame proof LED BULK HEAD light fitting FLP-WP of 30 watt made of aluminium alloy LM6 , with all accessories. internally prewired including taking down old fittings complete.
Submain wiring with three single core(for phase and neutral +earth) 4 sq mm wire using multistranded copper conductor PVC (FRLS) insulated unsheathed PVC insulated wire drawn through concealed stove enamelled steel conduit ISI Marked and all accessories of dia not less than 20 mm with and including steel conduit and accessories complete (Note: Three runs of 4 sqmm wire and one run of steel concealed conduit shall be measured as one run only
Submain wiring with five single core(for three phase and neutral +earth) 6 sq mm wire using multistranded copper conductor PVC (FRLS) insulated unsheathed PVC insulated wire drawn through concealed stove enamelled steel conduit ISI Marked and all accessoriesof dia not less than 25 mm with and including steel conduit and accessories complete for 12 way DB (Note: Five runs of 6 sqmm wire and one run of steel concealed conduit shall be measured as one run only
M&L concealed point wiring with 2.5sq mm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable, through & with and including stove enamelled steel conduit metallic ISI Marked and all accessories, including suitable metal flush box,hylem sheet white cover and 2.5sqmm PVC insulated unsheathed multistranded single core copper conductor FRLS, ISI marked cable as earth continuity conductor, cutting chasis, and making good disturbed surfaces etc complete all as specified & directed for 16 Amp socket.
M&L point wiring One light point /fan point controlled by one switch using approved colour coading as per IS with zerohologen flame retardent (HFFR) smoke free non free non toxic non corrosive with copper cable 1.5 Sqmm (normal area) single core insulated and unsheathed stranded cable 1100volts grade and including (ERW) stove enamelled concealed conduit heavy duty ISI marked and unsheathed copper conductor 1.5 Sqmm nominal area as earth wire as earth continuity conductor complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair Flame proof - weather proof CMRI approved MCB socket & plug combined 16 A, 500 V(3P+Earth) for EOT crane including taking down old socket & plug complete all as specified and as directed.
Supply & fix Flame proof Sheet metal enclsoure SPN 8 way for fixing MCBs 240 volt including MCB DP 32 A- 1 No as incomer & MCBs SP 6 to 16 Amps-6 Nos as outgoing with as specified .
Supply & fix in repair / replacement Flame proof Sheet metal enclsoure for fixing MCBs 4 way 240 volt including MCB DP 32 A- 1 No as incomer & MCBs SP 6 to 32 Amps-2 Nos as outgoing with as specified .
Supply & Fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V , complete all as specified and as directed.
M&L for Chemical earthing with copper earth plate of size 900 x 600 x 5 mm & copper earth strip 32 x 6 mm buried in ground vertically to a depth not less than 3.0 metre below ground level with top edge earth electrode at a depth not less than 2.40 metre deep below ground level including suitable quantity of backfill chemical compound for filling in each pit to cover earth electrode minimum 150 mm all around and electrode shall be jointed with the copper strip of size 32 x 6 mm by exhothermic weld complete with earth pit chamber of size 300 x300 mm and RCC cover for demarking the location of earth electrode location. Make of Back Fill Compound: Tercel (Isogel) (Australia)/ Indelec (Xgel) (France)/ ERICO (GEM) (USA)/ LPF (Reslo) (Australia) (for cat A bldg) (Note :- (i) The quantity of Backfill compound and depth of earth pit shall be increased by the contractor without any extra cost to Govt. to ensure earth resisitance value within less than 1 ohms on completion and testing. The testing of each earthing shall be carried out in presence of Engr-in-charge and test results shall be submitted duly signed by user concered while claiming payments.) (ii) Earth strip with protection pipe 50mm GI light grade upto 7.5 meter is deemed to be included in the rates quoted.
S & F in repair Air termination in repair, single pointed, copper rod 12mm dia and 300mm long fixed on GI pipe 50mm bore 1 mtr long with the help of nuts & bolts fixed on PCC block of suitable size complete all as specified and directed. Note : GI Pipe to be measured & paid saperately under relevant of schedule.
Taking down old unserviceable termination rod 20 mm dia for replacement.
M&L for earth continuity conductor or main earthing lead for down conductor fixed to wall on porceline insulators/saddle or on button or recess or chases or burried in ground or drawn in conduit/ pipe or fixed to pole or any other etc as required 32x6mm copper strip include screws, nuts & bolts.
All as per Item no 15.00 above but of size 20x 3.15mm .
All as per Item no 15.00 above but aluminium strip of size 25 x 3.15mm .
Taking down old Copper / Alluminium strip of any sizes as down conductor/roof conductor carefully for re-use, shifting unserviceable conductor to store under sch of credit all as directed.
M&L for refixing Copper / Alluminium strip of any sizes as down conductor/roof conductor after soldering between earth strip and refixing the copper / aluminium strip by providing new porciline insulator or burried in ground or drawn in conduit including PVC conduit, fixing apprangements with wall/roof all as per clause SSR part I and as directed.
M&L for PCC blocks of size 300mmx300mmx300mm made of 1:2:4 type B 1 ( 20mm graded crushed stone aggregate ) to be provided for each termination rod , complete all as specified and as directed
M& L for GI pipe medium grade 40 mm dia with socket at one end in the length of 1.2 mtr for supporting of air termination rod complete all as specified and as directed.
M&L for Earthing complete with copper plate electrode 600 mm x 600 mm x 3.15 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers up to 90 cm and with tibba sand up to top level and electrode connected to copper strip 20x3 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/equipment all as shown in electrical plate No. 5 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, PCC (1:2:4) type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick and MS frame of suitable size made of angle iron 50 x 50 x 6 mm, complete all as specified. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
M&L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.00 mm thick buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6 mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth strip protected by galvanized steel pipe 40 mm bore (light grade) connected to machinery/equipment all as shown in electrical plate No. 3 of SSR-2010 Part I and including necessary excavation and earth work in any type of soil, 20mm bore light grade GI pipe for watering, funnel, wire mesh, PCC (1:3:6) type C-1 chamber, PCC (1:2:4) type B-1 reinforced with 6 mm dia MS round bars @ 15 cm c/c both ways for cover 50 mm thick and MS frame of suitable size made of angle iron 50 x 50 x 60 mm, complete all as specified. Note :- (i) The unit rate includes earth lead and protection pipe up to maximum 7.5 metre from earth plate to earth point/test point. (ii) Earth pit shall be constructed minimum 0.5 metre away from earth.
Taking down old UNSV light fittings any type and Supply & Fix LED street light 72 Watt operating temp range -20deg.C to +50 deg C SL light fitting 72 Watt fitting ingress protection IP 66 conforming to IS 16107 with photo biological saftey as per IS 16108 , type of LED luminarie as per IS and type B , Type of LED modules as per IS 16103 type 3 with luminarie system efficiencey 100lm/watt with adjust mounting brackets. Make :-Surya Cat part No SLE UL 72W IP66 LXN or equivalent in WIPRO/Crompton Greaves/Bajaj.
Supply and fix LED 150 W flood light fitting on pole /wall with lense , high luminous rectangular LED flood light with innovative thermal management and available with multiple optics and equiped with IP 66 protection better distribution applicable for area lighting including suitable mounting brackets nuts and bolts and electrical connection complete all as directed.
Supply, laying in trenches and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3.5 core complete all as specified and directed.
Taking out LT cable XLPE/PVC sheathed 1100 volts grade armoured with aluminum conductor carefully of any size from trenches, poles, under floor etc for further use/disposal all as specified and directed. .
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core complete all as specified and directed.
Relaying of serviceable LT cable of size 10/16 Sqmm 4 core in trenches/ GI Pipe including relaying bricks retreived under item 11 above . Note : (i) Earth work will be measured and paid seperately under relevant items.
Excavation in trenches, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable for soft/ loose soil and getting out all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil all as specified and directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level all as specified and directed.
M&L for sand cushioning by using fine sand (Tibba sand ) in two layers , first layer of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable (total punned depth of sand shall be 180 mm after punning down) complete all as specified and as directed. Note: Punned thickness shall be measured for payment.
M&L for cover to underground cable with one layer of bricks using sub class B bricks (old size) laid flat across the cable complete all as specified and directed.
Material and labour for making cross hole suitable for 50 mm dia bore pipe including passing GI pipe of size 40 mm dia, below the road with the help of pressure pipe/ boring tools for passing the cable and removing of surplus soil to a distance not exceeding 100 mtr from work site all as directed. Note : Gi pipe to be measured and paid seperately under relevant items,.
Supply, laying and testing in replacement of 40 mm bore GI tubing (light grade) with new fittings, laying in floor/trenches for support UG cables as directed by Engr-in-Charge.
S&F in replacement for kiosk box of minimum size 300x200x100 mm for luminaries control swithes, weather proof made out of PVC/HDPE fire retardant, non fusing, shock & rust proof, single piece moulded/SMC housing and SMC cover with hinged door, pole mounting type comprising of aluminium busbar TPN of 60 Amps with 6 Amps MCB, SP with base channel , fixed on pole with MS, clamps 30x5 mm with necessary nuts, washer for Street light)
RAJENDER ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .