| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.4 LAccepted-AOC | ₹26.4 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹28.7 L+₹2.2 L (8.37%)Rejected-AOC | ₹28.7 L+₹2.2 L (8.37%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹30.1 L+₹3.6 L (13.7%)Rejected-AOC | ₹30.1 L+₹3.6 L (13.7%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹30.9 L+₹4.4 L (16.8%)Rejected-AOC | ₹30.9 L+₹4.4 L (16.8%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹31.6 L+₹5.2 L (19.5%)Rejected-AOC | ₹31.6 L+₹5.2 L (19.5%) | L5 | Rejected-AOC Rejected |
Tender Value
₹28.1 L
EMD Value
₹56,200
Closing Date
29 Nov 2019, 9:00 amClosed
CWE KHUMBATHANG
HQ CWE KHUMBATHANG PIN 900270
CWE/K-T17/2019-20 PROVISION OF MT GARAGES AT CERTAIN UNITS OF NIMU UNDER AGE(I) NIMU
2019_MES_282261_2
CWE/K-T17/2019-20
Open Tender
Civil Works
Item Rate
180 days
NIMU
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) NIMU
₹56,200
Yes
3 Apr 2020
23 Nov 2019
30 Nov 2019
23 Nov 2019
29 Nov 2019
23 Nov 2019
Amount
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide & not exceeding 1.5 mtr in depth as in foundation, drains, laying/taking out pipes or cables etc, or for shaft, well, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out in hard/dense soil, complete all as specified and directed by Engineer-in-Charge. .
Returning, filling in including spreding, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in any type of soil complete all as specified and directed by Engineer-in-Charge.
Removal of excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed by Engineer-in-Charge.
M & L for Plain Cement concrete, 1:4:8, type D-2, (using 40 mm graded mechanically crushed stone aggregates) as in foundations, fillings and mass concrete, etc. complete all as specified and directed by Engineer-in-Charge.
M&L for Precast cement concrete, 1:3:6 (type C-1) (using 20mm graded mechanically crushed stone aggregate) block mansonry with solid blocks, exceeding 10cm width and set in cement mortar 1:6 complete all as specified and directed by Engineer-in-Charge.
M & L for Plain cement concrete (Cast-in-situ) 1:2:4, type B-1, (using 20 mm graded mechanically crushed stone aggregates) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed by Engineer-in-Charge. Note: Any formwork required in this work shall deemed to be included in quoted rates.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed by Engineer-in-Charge.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, etc complete all as specified and directed by Engineer-in-Charge.
Use & waste formwork to sides of concrete foundation, footings, bases of columns, raft and raft beams, sides & soffits(if any) of foundation & plinth beams and similar work; vertical or to batter for rough finished flat surfaces of concrete etc complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete, M-30 (Design mix) (using 20mm graded mechanically crushed stone aggregate) as in foundations, including raft, footings, foundation beams, plinth beams; bases for columns, basement slab and mass concrete etc complete all as specified and directed by Engineer-in-Charge. Note: Formwork & reinforcement shall be measured and paid separately.
S&F Mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut exceeding 30cm long and dia of neck exceeding 12 mm but not exceeding 20 mm complete all as specified and directed by Engineer-in-Charge.
M&L for 10 mm thick rendering in cement mortar 1:6 on fair face of brickwork or concrete surfaces as in wall, finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered/concrete surfaces and applying three coats of white wash as in wall, complete all as specified and directed by Engineer-in-Charge.
M & L for Hardcore of broken stone or boulders of guage not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed by Engineer-in-charge.
M & L for 75mm thick, Plain cement concrete, type C-2, 1:3:6 (using 40 mm graded mechanically crushed stone aggregate) laid in slope as in plinth protection, finished the surface even and smooth without using extra cement including making expansion joints filled with bitumen mastic filling consisting of 85/25 bitumen and sand in the ratio of 1:1 complete all as specified and directed by Engineer-in-Charge.
S&F for rolled mild structural steel work as in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240, complete all as specified and directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or previously untreated steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats synthetic enamel paint over & including a coat of redoxide primer, complete all as specified and directed by Engineer-in-Charge.
S&F mild steel work as in half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new or previously untreated steel surfaces of any description not exceeding 10 cm in width or girth, when unconnected with other painting or when painted in a different tint and applying two coats synthetic enamel paint over & including a coat of redoxide primer, complete all as specified and directed by Engineer-in-Charge.
M & L for 150mm thick, Plain cement concrete, 1:5:10, type E-2 (using 40mm graded mechaniacally crushed stone aggregates) as in sub base of floors, finished the surface even and rough to receive top layer of floors, etc complete all as specified and directed by Engineer-in-Charge.
M & L for 100mm thick, Plain cement concrete, 1:2:4, type B-2 (using 40mm graded mechaniacally crushed stone aggregates) as in topping layer of floors, finished the surface even and fair complete all as specified and directed by Engineer-in-Charge.
M&L forming 12 mm thick Expansion joints filled with pre-formed bituminous filler and top 30 mm primed and sealed with Grade ‘A’ sealing compound, for 100 mm thick concrete slab complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring ( as per IS colour coding) with multi-stranded copper conductor FRLS, PVC insulated, unsheated 1.5 sqmm (nominal area) cable, 1100 volt grade in & including heavy duty PVC rigid non metallic casing caping (not less than 25mm width) (ISI marked) on wall with all fittings / accessories and including 1.5 sqmm (nominal area) FRLS PVC insulated copper earth wire connected to common earth dully including wall mounted non metallic terminal boxes of suitable size for mounting switches, sockets etc with 3mm thick plastic laminated sheet cover for one light point/fan point/bell point controlled by one switch, complete all as specified and directed by Engineer-in-Charge. Note:- The cost of Cutting / Chasing & making good the disturbed surface wherever required for conduit & sinking of boxes shall deemed to be included in quoted rates.
Description all as per BOQ item No. 26.00 here-in-before but for one 3 pin socket outlet, 5 Amps on independent board complete all as specified and directed by Engineer-in-Charge.
Description all as per BOQ item No. 26.00 here-in-before but for one 3 pin socket outlet, 5 Amps on same board with other switch complete all as specified and directed by Engineer-in-Charge.
Description all as per BOQ item no 26.00 here-in-before but for power point with 2.5 sqmm (nominal area) FRLS PVC insulated unsheathed copper cable on independent board complete all as specified and directed by Engineer-in-Charge.
S&F switch socket combination outlet, 2 in 1, three pin, 5 & 15 Amp, flush type universal complete all as specified and directed by Engineer-in-Charge.
S&F socket outlet, 2 in 1, three pin 5 Amp, flush type complete all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush type, single pole, one way, 5 Amps, complete all as specified and directed by Engineer-in-Charge.
S&F ceiling rose, three terminals, flush type, ISI marked, PVC/polycarbonate, isolated body, complete all as specified and directed by Engineer-in-Charge.
S&F LED light fitting, single tube, 1 x 20 watt, 4 feet long, with bipin holders with all accessories including LED tube rod 20 watt, internally pre-wired and including connecting electrically with 3 core PVC insulated sheathed flexible copper conductor cable to ceiling rose complete all as specified and directed by Engineer-in-Charge. Make: Catpart No. TARA-M/20W of C&S Electric / Catpart No. DMLN1LT8-16 (for frame/batten) & LTT8-20(for rod) of Crompton / Catpart No. D562065 (for batten) & D612065(for rod) of Wipro / Catpart No. LHEXCEP7UN1W020 (for rod) & LHFXCEP1TN1W020 (for batten) of Havells.
S&F lamp holder ,PVC/Polycarbonate type with back plate suitable for batten fitting (angle /plain) fixed on & including round block of teak wood 8cm dia & 4cm thick complete all as specified and directed by Engineer-in-Charge.
S&F street light LED fitting, 25 watt, IP66, complete and including brackets of 40mm bore GI pipe(light grade), 1.5 mtr long, bent to shape as required at site for fixing the light fittings with necessary clamps, nuts and bolts and making necessary connections, complete all as specified and directed by Engineer-in-Charge. Make: Catpart No. INDUS/25W of C&S Electric or equivalent in Cromptom / Havells / Wipro.
S&F distribution board, double door, vertical, made out of sheet metal enclosure (CRCA sheet) dust and vermin proof, single pole and neutral, 8 way with 200 Amps rated copper bus bar, neutral link, earth bar, din rail, IP43 protection, , 240 volts, flush to wall / fixed on surface, complete all as specified and directed by Engineer-in-Charge.
S&F MCB, single pole & neutral, 63 Amp, 240 volt, rupturing capacity not less than 10 KA, 'C' curve, IP 20 complete all as specified and directed by Engineer-in-Charge.
S&F MCB, single pole, 6 to 32 Amp, 240 volt, rupturing capacity not less than 10 KA, 'C' curve, IP 20 complete all as specified and directed by Engineer-in-Charge
M&L earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically (earth pit not less than 2.25 mtrs deep below normal ground level) with top edge of earth plate at a depth not less than 1.50 metre below the normal ground level, connected to galvanised earth lead wire of 4.00mm dia as earth by means of nuts, bolts, washers, checknuts of iron or steel including PCC pits in cement concrete 1:2:4, type B-1 (using 20mm graded mechanically crushed stone aggregates) and RCC cover in cement concrete 1:2:4, type B-1(using 20mm graded mechanically crushed stone aggregates) and necessary earth work in any type of soil, light grade GI watering pipe 20mm bore with funnel and wire mesh and 15 mm bore GI pipe light grade protection pipe upto test point etc including excavation and charcoal, common salt surrounded with 15cm all around the plate, complete all as specified and shown electric plate No. 3 of SSR Part-I including testing on completion complete all as specified and directed by Engineer-in-Charge.
Supply, laying & testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power LT cable (heavy duty), with stranded aluminium conductor, 1100 volts (earthed) grade, corss sectional area 16 sqmm, 2 core, complete all as specified and directed by Engineer-in-Charge.
M&L for sand cushioning to under ground cables with a layer of sand 8cm thick before laying the cable and 15cm thick after laying the cable, as specified in clause 19.75 of SSR Part-I, 2009 complete all as specified and directed by Engineer-in-Charge.
M&L factory made, un-reinforced precast concrete cable cover, class LV, type 1, flat, size 250mm X150mm X 40mm, complete all as specified and directed by Engineer-in-Charge.
S&F 50mm bore GI steel tubing, light grade with all fittings and fixtures complete laid in trenches / floor or fixed on wall/ceiling/pole, for protection of cable including fixing of clamp wherever required complete all as specified and directed by Engineer-in-Charge.
THINLES OTZER
Takshos Enterprises
M/S O PAL ENGINEERS & CONSTRUCTION COMPANY
SANA CONSTRUCTION CO.
M/S HAJI HASSAN ENGINEERING WORKS KARGIL
M/S SK TRADERS
M/S SUN RISE BUILDERS
ABASS ENTERPRISE
M/S ALI GHULAM
M/S MOHD ALI
M/S TAMCHOS GURMATH
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .