Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.9 LAccepted-AOC 691 INDUSTRIAL AREA PHASE II CHANDIGARH 160 002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹14.8 L+₹2.4 L (19.1%)Rejected-AOC | L2 | Rejected-AOC Other than lowest |
Tender Value
₹19.8 L
EMD Value
₹39,600
Closing Date
22 Sept 2023, 6:00 pmClosed
GARRISON ENGINEER
GE (U) CHANDIMANDIR
REPAIRS CUM MAINTENANCE / PREVENTIVE MAINTENANCE OF UPS SYSTEM AND OT LIGHTS AT COMMAND HOSPITAL, CHANDIMANDIR
2023_MES_605439_2
GE(U)/CHM-15/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE (U) CHANDIMANDIR
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE (U) CHANDIMANDIR
₹39,600
Yes
18 Nov 2023
24 Aug 2023
26 Sept 2023
24 Aug 2023
22 Sept 2023
8 Sept 2023
Amount
Preventive maintenance/servicing of UPS cum voltage regulator 01 X 60 KVA, 415 Volt, 50 Hz of Make : LIEBERT by the authorized service Engineer of LIEBERT UPS India Pvt Ltd. Testing of installation shall be carried out after servicing and Test certificate shall be provided by authorised service Engineer. The installation shall be checked/inspected at any time on requirement basis and as directed, for detecting and rectifying the fault, if any, during the currency of contract and servicing done to remove fault accordingly, complete all as specified and directed.
Preventive maintenance/servicing of UPS cum voltage regulator 01x 80 KVA, 415 Volt, 50 Hz of Make : LIEBERT by the authorized service Engineer of LIEBERT UPS India Pvt Ltd. Testing of installation shall be carried out after servicing and Test certificate shall be provided by authorised service Engineer. The installation shall be checked/inspected at any time on requirement basis and as directed, for detecting and rectifying the fault, if any, during the currency of contract and servicing done to remove fault accordingly, complete all as specified and directed.
Preventive maintenance/servicing of UPS cum voltage regulator 01x 20 KVA, 415 Volt, 50 Hz of Make : LIEBERT by the authorized service Engineer of LIEBERT UPS India Pvt Ltd. Testing of installation shall be carried out after servicing and Test certificate shall be provided by authorised service Engineer. The installation shall be checked/inspected at any time on requirement basis and as directed, for detecting and rectifying the fault, if any, during the currency of contract and servicing done to remove fault accordingly, complete all as specified and directed.
Note for items 1,2 and 3 above :- Servicing of UPS Shall include the following:- (a) General cleanliness of equipment. (b) Visual inspection of UPS. (c) Checking all settings, doing relevant adjustment where necessary. (d) To rectify any apparent fault immediately where possible and keeping records for other faults for rectifying later, but as early as possible. (e) To take electrical readings/measurements to establish the state of the UPS as perfectly operational . (f) Checking setting of adjustable device (g) Visual inspection of the UPS batteries and servicing the same. (h) Checking for correct and accurate operation of all instruments (j) Recording total voltage of battery under float condition. (k) Checking each battery for maitaining required voltage during the contract period. (l) Checking and installation of software and hardware program if necessary thruogh authorized engineer of SOCOMEC UPS company (m) Servicing shall be caried out on as required basis and record of servicing shall be maintained.
Supply and fixing in replacement communication interface board (CIB) of 60 KVA UPS with board of make as existing at site including complete connections of existing cables with and CIB, making UPS in running condition, complete all as specified and directed. Make : LIEBERT or as approved by GE.
Supply and fixing in replacement communication interface board (CIB) of 80 KVA UPS with board of make as existing at site including complete connections of existing cables with and CIB, making UPS in running condition, complete all as specified and directed. Make : LIEBERT or as approved by GE
Supply and fixing in replacement communication interface board (CIB) of 20 KVA UPS with board of make as existing at site including complete connections of existing cables with and CIB, making UPS in running condition, complete all as specified and directed. Make : LIEBERT or as approved by GE
Supply and fixing in replacement Monitoring unit Board and programming flashing of 60 KVA UPS, of make as existing at site with complete connections, through authorized rep/engineer/operator of OEM, complete all as specified and directed. Make : LIEBERT or as approved by GE.
Supply and fixing in replacement Monitoring unit Board and programming flashing of 80 KVA UPS, of make as existing at site with complete connections, through authorized rep/engineer/operator of OEM, complete all as specified and directed. Make : LIEBERT or as approved by GE.
Supply and fixing in replacement Monitoring unit Board and programming flashing of 20 KVA UPS, of make as existing at site with complete connections, through authorized rep/engineer/operator of OEM, complete all as specified and directed. Make : LIEBERT or as approved by GE.
Supply and fixing in replacement charger board of 80 KVA UPS, complete all as specified and directed. Make : SOCOMEC, LIEBERT, POWER ONE.
Supply and fixing in replacement charger board of 60 KVA UPS, complete all as specified and directed. Make : SOCOMEC, LIEBERT, POWER ONE.
Supply and fixing in replacement charger board of 20 KVA UPS, complete all as specified and directed. Make : SOCOMEC, LIEBERT, POWER ONE.
Supply and fixing in replacement Sealed Maintenance Free lead acid battery 12 volt 200 AH conecting each other with copper plate/bracket of suitable size, complete all as specified and directed. Make : Exide (Power Safe), Amron, Luminous, SUKAM, TATA GREEN
Supply and fixing in replacement Sealed Maintenance Free lead acid battery 12 volt 100 AH conecting each other with copper plate/bracket of suitable size, complete all as specified and directed. Make : Exide (Power Safe), Amron, Luminous, SUKAM, TATA GREEN
Supply and fixing in replacement Sealed Maintenance Free lead acid battery 12 volt 65 AH conecting each other with copper plate/bracket of suitable size, complete all as specified and directed. Make : Exide (Power Safe), Amron, Luminous, SUKAM, TATA GREEN
Supply and fixing in replacement Sealed Maintenance Free lead acid battery 12 volt 42 AH conecting each other with copper plate/bracket of suitable size, complete all as specified and directed. Make : Exide (Power Safe), Amron, Luminous, SUKAM, TATA GREEN
Supply and fixing in replacement IGBT (Insulated Gate Bipolar Transistor) rectifier board for 80 KVA capacity UPS including internal hardware and software and making connections to the system for smooth functioning of UPS , complete all as specified and directed. Make:- Emersion, SOCOMEC, LIEBERT.
Supply and fixing in replacement IGBT (Insulated Gate Bipolar Transistor) rectifier board for 60 KVA capacity UPS including internal hardware and software and making connections to the system for smooth functioning of UPS , complete all as specified and directed. Make:- Emersion, SOCOMEC, LIEBERT.
Supply and fixing in replacement IGBT (Insulated Gate Bipolar Transistor) rectifier board for 20 KVA capacity UPS including internal hardware and software and making connections to the system for smooth functioning of UPS , complete all as specified and directed. Make:- Emersion SOCOMEC, LIEBERT.
Servicing of OT lights Model: Dr Med 5030 Make : Dr Med, by the authorized service engineer of Dr Med company, including taking down of OT lights, cleaning and aligning all parts, removing /scrubbing of rust to ensure free movement of dome (up-down/ left to right), fitting back properly and making connections of wiring from UPS to OT lights, including attending promptly the break down happened at any time, complete all as specified and directed by Engineer-in-charge.
Servicing of OT lights Model: Dr Med 5030 Make : Dentis Lewis, by the authorized service engineer of Dr Med company, including taking down of OT lights, cleaning and aligning all parts, removing /scrubbing of rust to ensure free movement of dome (up-down/ left to right), fitting back properly and making connections of wiring from UPS to OT lights, including attending promptly the break down happened at any time, complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement LED module assembly Major/Minor dome of OT Light of Dr Med complete all as specified and directed. Model Dr Med LED 5030 double dome, Model Dentis lewis LED 5030.
Supply and fixing in replacement head controller PCB of OT LightS, complete all as specified and directed. Model Dr Med LED 5030, Model Dentis lewis LED 5030.
Supply and fixing in replacement arm controller PCB of OT Lights, complete all as specified and directed. Model Dr Med LED 5030 & Model Dentis lewis LED 5030.
Supply and fixing in replacement SMPS input/output harness of OT Lights, complete all as specified and directed. Model Dr Med LED 5030, Model Dentis lewis LED 5030.
Supply and fixing in replacement main PCB bracket of OT Lights, complete all as specified and directed. Model Dr Med LED 5030, Model Dentis lewis LED 5030.
Supply and fixing in replacement damper bolt OT Lights, complete all as specified and directed. Model Dr Med LED 5030, Model Dentis lewis LED 5030.
Supply and fixing in replacement Handle shaft assy of OT Lights, complete all as specified and directed. Model Dr Med LED 5030, Model Dentis lewis LED 5030.
Disconnecting/Taking down old unserviceable SMF type sealed lead acid battery 12 volt 100-200 AH and recharging the same from aothorised workshop/shop of battery replacing, unserviceable terminal posts to meet the required standard of dischage of voltage and current and refixing the battrey in its original location, complete all as specified and as directed .
Disconnecting/Taking down old unserviceable SMF VRLA type sealed lead acid battery 12 volt 42-65 AH and recharging the same from aothorised workshop/shop of battery, replacing unserviceable terminal posts etc, including topping up if required, to get the required standard of dischage of voltage and current and refixing the battrey in its original location, complete all as specified and as directed .
Taking out fan motor single phase 230/240 Volt from the existing UPS by carefully dismantling, taking out burnt copper winding and rewinding the same with super enamelled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make, including varnishing to copper winding, re-assembling the motor, including testing the motor at medium and full load complete for the UPS of following capacity 60-80 KVA, complete all as specified and as directed
Taking out fan motor single phase 230/240 Volt from the existing UPS by carefully dismantling, taking out burnt copper winding and rewinding the same with super enamelled copper winding wire of appropriate size and gauge, including replacement of defective bearing and bushes of existing size and standard make, including varnishing to copper winding, re-assembling the motor, including testing the motor at medium and full load complete for the UPS of following capacity 20 KVA, complete all as specified and as directed
Bharat Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .