| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.2 LAccepted-AOC SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹28.7 L+₹1.6 L (5.72%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹29.2 L+₹2.0 L (7.51%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹30.9 L+₹3.8 L (13.8%)Rejected-Finance 18 GOBINDPURA STREET NO 10 PO RAYON SILK MILLS PURANI CHUNGI CHHEHTRA AMRITSAR 143001 PB | AMRITSAR | AMRITSAR | PUNJAB | 143001 | L4 | Rejected-Finance Being other than L1 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
11 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE NAMS
GE NAMS AMRITSAR
DAY TO DAY COMPLAINTS OF EXTERNAL ELECT SUPPLY AND ALLIED WORKS AT NAMS
2023_MES_618660_1
GE NAMS-63/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE NAMS
CLASS D CATEGORY a(i)
8 documents required · 8 mandatory
₹500
GE NAMS
₹96,000
Yes
7 Nov 2023
13 Sept 2023
18 Oct 2023
13 Sept 2023
11 Oct 2023
27 Sept 2023
Amount
Day to day attending complaints & maintaining the electric supply GE NAMS Area round the clock (24 Hours) comprising the following electrical distribution net work / transformers / LT panels by contractor/his rep with fwg networks:- (i) Feeder No-1 emanating from MRS to TOP II, Appx length – 4.5 Km. (ii) Feeder No-2 emanating from MRS to NME, Appx length = 1.8 Km, LT Panels , LT overhead lines appx – 2.50 km and 01 No transformer. (iii) Feeder No 03 emanating from TOP I Sub station to Old Officer colony Feeder, Appx length = 3 Km along with 08 transformers with GOD s of different capacities , LT Panels , LT overhead lines appx – 4.5 km. (iv) Feeder No 04 emanating from TOP I Sub station to Back Feeder Appx length = 3 Km along Complete upto end point. (v) Feeder No 05 emanating from TOP II Sub station to Old Kathania Accn Appx length = 2 Km complete upto end point (vi) Feeder No 6 emanating from TOP II Sub station to Back Feeder to Army school, central school Appx length = 3.5 Km complete upto end point (vii) Feeder No 7 emanating from TOP II Sub station to units area - Approx 3.5 Km Complete upto end point. (Viii) Feeder No 8 emanating from TOP II Sub station to NOC II, Appx length = 1 Km complete upto end points
(ix) Feeder No 9 emanating from TOP II Sub station to CP -6 baffle range Appx length = 4 Km complete upto end points. (x) Feeder No 10 emanating from 66 KV Sub station to New Red Colony, New Kathania & NOC-I Appx length = 2.5 Km complete upto end points. Preodicity - round the clock. (B) Nature of work to be done (i) Maintaining the serviceability and attending break down complaints of electric supply of all the feeder including of New ASR Cantt area mentioned under Sl 2.01(i) to 2.12(xii) here in before . (ii) Attending the complaint of external electric supply – from sub station to main board / DB of the occupant. (iii) Periodical maintenance/complaints of all the feeders mentioned here-in-before which includes – (a)Replacement of overheated jumper / blown off jumpers . (b) Replacement of blown off fuses . (c ) Periodical complaints of LT panels . (f) Complaint to be attended within 1 to 2 hrs otherwise penalty to be made at @ Rs. 500/- per complaint. (g) Complaint Register & complaint slip shall be provide by the contractor wihout any extra cost paid to him and maintained by the SBA on duty/ Contractor rep present at Complaint cell in supervison of JEEM and signature of JE / Engr in charge will be taken on each complaint after completion of complaint on daily basis
Note :- No extra cost shall be paid to the contractor for complaint register and complaint slip. Note – (i) Time consuming jobs such as replacement of defective cable by extension of loop and periodical trimming of trees / branches along the over head lines shall be measured and paid separately . (ii) Before attending any complaints of external elect supply contractor or his rep shall ensure that proper shut down has been taken in physical presense on permit slip and will be lifted on the same permit by the physical reporting at Sub station with proper time and signature. Note . No shut down given/ lifted on mobile phone. Shut down shall be given / lifted only after physical reporting of electrician at power house (v) All safety precaution will be taken by the Contractor/his rep. incase of any physical injury / any mishappning contractor is responsible for all the medical treatment and compansation to the individual . No extra cost paid to the contractor for the same. (vi) Contractor will provide shut down permit book for taking shut down permit from the JE/ Engr-in-Charge on duty. No extra cost will be paid for the same. Contractor has to deposit all the stores in advance for attending day to day complaints and late hours complaints.
Excavation trenches not exceeding 1.5m wide & not exceeding 1.5m in depth for and getting out in any of soil complete all as specified and as directed.
Returning, filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified and directed.
Removal of surplus excavated soil to a distance not exc 50m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed.
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as specified and directed.
Supply laying in replacement & testing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty) LT 1100 volt grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed.
Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints, Sockets, Elbows, bends and End caps etc.. all as specified and directed by Engr in Charge of size 50mm outer dia and 38mm inner dia
Description all as per items No 8.00 but of size 78mm outer dia and 63mm inner dia.
Excavating and relaying cables LT loops near the poles LT Panels transformers, cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
Excavating and relaying high tension cables loops near the poles , transformers, cutting the damages/burnt parts of cable and reconnecting its into positions complete with thimbles, nut bolts, sleaves all as specified and directed by Engineer-in-Charge.
Replacement of pin type porcelain white, brown or green insulator including one galvanized mild steel spindle, two galvanised iron washers & one galvanised nut 50mm height, 65mm dia for working pressure 1100 volts grade.all as specified and directed by Engr-in charge
S & F in shackle type,vitreous Insulator incl one galvanised mild steel spindle, two galvanised iron washerrs and one galvanised iron nut, 100 mm height, 115 mm dia ,suitable for 1100 Volt and as directed by engineer in charge.
Supply and spraying anti vegetation chemical liquid of 1ltrs bottle mixed with water as per direction of Engr in charge
Supply & fixing in replacement Disc type type polymer insulator including one galvanised mild steel straps, washers and nut , including removal of existing insulators complete all as specified and directed.
Supply & fixing in replacement Pin type type polymer/ porcelain insulator including one galvanised mild steel straps, washers and nut, size 150mm length and 150mm dia including removal of existing insulators complete all as specified and directed.
Supply and fixing in replacement of male female contacts of gang operative switch made out of brass and rated capacity 200 amps ,make matching with the existing switch complete all as specified and directed .
Supply and fixing in replacement of copper ribbon suitable for 200 amps rated capacity gang operative switch, 45 CM long complete all as specified and directed .
M&L for grease suitable for VCB and air break switches complete all as specified and as directed by Engr-in-Charge
S&F in replacement air break switch insulator, 200 Amp, 11 kv complete all as specified and as directed.
S&F in replacement spindle suitable for 11 kv Pin insulator complete all as specified and as directed.
Taking out carefully manually by excavation of existing cable of any size upto transfromer with loops and relaying with old retrieved cable cover complete the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) Unit rate shall include in excavation and returning filling.
Taking out carefully manually by excavation of existing cable of any size LT with loops and relaying with old retrived brick complete the same after repair of cutting the damages / burnt parts of cable and reconnecting its into original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) LT Cable Joint & DWC Pipe will be measured and paid sepearetly. (ii) Unit rate shall be included in excavation and returning filling.
Taking out carefully manually by excavation / Pulling of cable with rope of existing LT cable of size 10 Sqmm to 95 Sqmm with loops and relaying with existing DWC pipe repair/ cutting the damages / burnt parts of cable and reconnecting into original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) LT Cable Joint will be measured and paid sepearetly. (ii) Unit rate shall include for excavation and returning filling.
Taking out carefully manually by excavation / Pulling of cable with rope of existing LT cable of size 120 Sqmm to 240 Sqmm with loops and relaying with existing DWC pipe repair/ cutting the damages / burnt parts of cable and reconnecting into original positions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i) LT Cable Joint will be measured and paid sepearetly. (ii) Unit rate shall include for excavation and returning filling.
Material and labour for cleaning away all grass vegetation, scaling shrubs bushes under growth roots and trees not exceeding 30cm girth and removing rubbish aroung LT Panel, transformer, sub stations, LT Poles, under over head lines complete all as specified and as directed.
Material only in replacement straight through joint heat shinkable suitable for upto 50 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material only in replacement straight through joint heat shinkable suitable for 70 sqmm to 120 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material only in replacement straight through joint heat shinkable suitable for 185 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Material only in replacement straight through joint heat shinkable suitable for 300 sqmm LT 3.5 core 1100 volts XLPE cable type complete all as specified and directed.
Supply and replacement bush rod suitable for indoor / outdoor type 250 to 315 KVA transformer complete with brass stud, brass nuts, brass cup and packing gasket complete all as spd and directed.
Description all as per Srl item No 31.00 here-in-before but suitable for 160 to 200 KVA transformer.
Supply and Fix high grade PVC LT overhead phase to phase line spacer suitable for 4 lines/wires, suitable for verticale and horizontal line complete all as specified and as directed.
Supply and fixing in replacement aluminium thimble of size 25 to 35 Sqmm
Supply and fixing in replacement aluminium thimble of size 50 sqmm to 70 Sqmm complet all as specified.
Supply and fixing in replacement aluminium thimble of size 95 to 120 sqmm
Supply and fixing in replacement aluminium thimble of size 185 to 240 sqmm
Supply and fixing in replacement aluminium thimble of size 300 to 400 sqmm
Supply and fixing in replacement copper thimble of size 300 to 400 sqmm
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 10 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Supply and laying or fixing in replacement 1100 Volts grade heavy duty cable with PVC insulated aluminium standard conductor served with an inner sheathing of PVC tape and over all PVC Sheathed in service connections , one twin core 16 Sqmm cable standard conductor cable flat or circular all as specified and directed by Engineer- in- Charge.
Material and labour for tinned copper fuse wire 22 SWG to 35 SWG 5 Ampere to 24 Ampere (14 sizes ), each roll weight from 125 to 150 gm , sutable for fuse wire complete all as specified and as directed.
Material and labour in replacement of medium voltage fire resistant high quality PVC self adhesive electrical insulaion tape (Red, Yellow, Blue & Black) high quality size minimum 18mm width and 07 mtr long complete.
Material and labour in replacement for high voltage fire resistant, flame retardant self adhesive electrical insulaion tape suitble for 11KV (RYB), high quality size minimum 38mm width and 09 mtr length complete.
M&L for replacement of bamboo ladder 28 step suitable for HT complaints complete all as specified and as directed.
M&L for replacement of bamboo ladder 24 step suitable for LT complaints complete all as specified and as directed.
Supply and fill up transformer oil topping up having dielectric strength not less than 50 KV at 4 mm gap conforming to IS complete all as specified and directed.
M&L for replacement of earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI strip of size 32 X 6 mm and 40 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009. Note :- All joints either strip to strip of strip to earth plate are fixed with welded joints.
M&L for replacement of earthing complete with galvanized steel earth plate electrode 600x600x6mm thick buried in ground vertical to a depth not less than 2.25 mtrs deep below ground level with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanized GI wire of size 4 mm dia and 15 mm dia bore 7.5 mtr long light grade GI protection pipe for earth strip and GI watering pipe 40 mm dia medium grade from the top edge of earth plate fixed with deep cut on one end of pipe and fix from earth plate up to one feet above ground level of other end and plugged watering pipe at top with MS cap and grouted in PCC 1:2:4 of size 30 X 30 X 30 CM etc and 15 CM alternate layer of charcoal and salt around all sides of earth plate all as shown in electric plate no 3 of SSR part I of 2009.
Material only in replacement of straigth through joint heat shinkable suitable for 185 sqmm 3 core 11000 volts XLPE cable type complete all as specified and directed
M/s MAHAJAN CONSTRUCTION CO.
CHINAR ENGINEERS AND BUULDERS
SUN CHEMICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .