Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹12.0 L+₹4,029 (0.34%)Rejected-Finance | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹12.7 L+₹72,581 (6.07%)Rejected-Finance S NO 279 1 1A PLOT NO 113 KUTWAL COLONY SASTHE WASTI LOHEGAON PUNE 411 047 | PUNE | MAHARASHTRA | 411047 | L3 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
29 Oct 2020, 6:00 pmClosed
SHRI JANAK RAJ EE GARRISON ENGINEER NW
GARRISON ENGINEER (NW) VASCO Opposite KV No.2, School, Shantinagar, Vasco-Da-Gama, Goa-403802.
8285/E8
2020_MES_351277_2
8285/E8
Open Tender
Civil Works
Item Rate
180 days
VASCO
Class E Category b i
8 documents required · 8 mandatory
₹500
Yes
GE NW VASCO
₹28,000
Yes
7 Nov 2020
3 Oct 2020
31 Oct 2020
3 Oct 2020
29 Oct 2020
16 Oct 2020
12 Oct 2020 - 15 Oct 2020
Amount
Taking down carefully any type of copper/aluminium point wiring (light, fan, socket or power) complete including conduits/casing caping with fittings such as switches, ceiling roses, pendents, regulators, bells, sockets, tube light fittings etc, removing the materials /debris and making good the disturbed surface of walls & floors etc to match with the original existing finish complete all as specified and as directed.
M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC Casing & Caping double lock type of as required width (not less than 20 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box 60mm deep of required size made out of 2mm thick MS sheet duly painted both sides with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers and including provision of modular metal flush box, modular cover plate with frame top cover for mounting switches, fan regulators etc for one light point controlled by one 5 Amp switch one way complete all as specified and as directed.
All as per item No. 2.00 above, but for one fan/exhaust fan point controlled by one bell push 5 Amp all as specified and as directed.
All as per item No. 2.00 above, but for one bell/buzzer point controlled by one bell push 5 Amp all as specified and as directed.
All as per item No. 2.00 above, but for one light point controlled by two 2-way switches all as specified and as directed.
All as per item No. 2.00 above, but for one 3/5 Pin, 5 Amp Switch socket out let on the independent board complete all as specified and as directed.
M & L for surface point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LSH conforming to IS : 694 of size 2.5 Sq mm single core, including one No. 2.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LSH as continuous earth wire drawn in and including PVC Casing & Caping (double interlock type) of as required width (not less than 20 mm in width) ISI marked medium duty, white colour with all accessories of same grade, fixed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box 60mm deep of required size made out of 2mm thick MS sheet duly painted both sides with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers and including provision of modular metal flush box, modular cover plate with frame top cover for mounting switches socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type on the independent board complete all as specified and as directed.
S & F in repairs Switch Piano flush button single pole one way 5 A , 240 V complete all as specified and as directed.
S & F in repairs Switch Piano flush button single pole two way 5 A, 240 V complete all as specified and as directed.
S & F in repairs modular Switch single pole one way 6 A, 240 V complete all as specified and as directed.
S & F in repairs modular Switch single pole one way 16 A, 240 V complete all as specified and as directed.
S & F in repairs Bell push flush button, single pole, one way, 240 V, 5 A complete all as specified and as directed.
S & F in repairs Modular Bell push single pole, one way, 240 V, 6 A complete all as specified and as directed.
S & F in repairs Switch Socket combination 2 in 1, 5 Amp flush type, 240 V, complete all as specified and as directed.
S & F in repairs Modular Socket outlet 2 in 1, 6 Amp , 240 volts, complete all as specified and as directed.
S & F in repairs Switch Socket Combination 5A/16A, 5 in 1, 3 pin, 240 volts complete all as specified and as directed.
S & F in repairs Modular Socket outlet 5A/16A, 5 in 1, 3 pin, flush type universal, 240 volts complete all as specified and as directed.
S & F in repairs Ceiling rose, surface bakelite, 65 x 50 mm two/ three terminals 240 volts complete all as specified and as directed.
S & F in repairs call bell ding dong AC,230 volts,single pole all as directed.
S & F in repairs stepped type electronic fan regulator flush type as per exisitng model on the existing board all as directed.
S & F in repairs stepped Modular electronic fan regulator flush type on the existing board all as directed.
Taking down unserviceable any type of copper / aluminium sub main wiring of any type / size / core / type complete including conduits/casing caping etc, removing the materials / debris and making good the disturbed surfaces of walls, floors and ceilings etc to match with the original existing finish complete all as specified and as directed.
M & L for sub main wiring with two runs of single core 2.5 Sqm, FRLS Copper conductor PVC insulated unsheathed cable as per IS 694-1990 (third revision) drawn through & including non- metallic rigid PVC casing caping (double interlock type) of suitable width medium duty with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 2.5 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board/distribution board and testing on completion etc complete all as directed. (Note :- Two runs of cable, one run of earth continuity conductor and one run of PVC casing caping/conduit shall be measred as one unit)
All as per item No. 23.00 above, but two run of single core 4 sqmm and one run of 4 sqmm cables as earth continuity conductor all as directed.
All as per item No. 23.00 above, but two run of single core 6 sqmm and one run of 4 sqmm cables as earth continuity conductor all as directed.
All as per item No. 23.00 above, but four run of single core 6 sqmm and two runs of 4 sqmm cables as earth continuity conductor all as directed.
All as per item No. 23.00 above, but four run of single core 10 sqmm and two runs of 6 sqmm cables as earth continuity conductor all as directed.
Taking down unserviceable any type of Main Switch, DB's including MCBs including wooden / GI / MS sheet board etc and removing from site and making good the disturbed surface of wall etc all as specified and as directed.
S & F in repairs sheet metal enclosure SPN with a two pin and earth plug and socket complete with one SP MCB 20 Amps complete all as specified.
S & F in repairs MCB DB SPN 8 way DB 230 V with 200 A rated bus bar double door type complete all as specified and as directed.
All as per item No. 30.00 above, but MCB DB SPN 4 way DB 230 V with 200 A rated busbar.
All as per item No. 30.00 above, but MCB DB SPN 12 way DB 230 V with 200 A rated busbar.
S & F in repairs vertical type MCCB DB TPN 4 way, 415 volts, double door, factory made sheet metal enclosure with 200 amps rated copper bus bar, neutral bar, earth bar painted with epoxy based powder coated suitable for mounting MCCB FP 63 amps as incomer and MCB TP/SP as outgoings complete with IP-43 protection and concealed in wall including making incoming and outgoing cable/wire connections complete all as specified and directed.
S & F in repairs MCB TPN 40 to 63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F in repairs MCB SPN 06 -32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F in repairs MCB TPN 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F in repairs MCB SP 06 to 32 amps 230 volts C curve, 50 HZ AC 10 KA complete all as specified.
S & F in repairs MCB TP 32 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
S & F in repairs MCB TP 40-63 amps 415 volts C curve, 50 HZ AC 10 KA complete all as specified and as directed.
M & L for exhaust fan AC single phase 230V of size 300 mm sweep heavy duty with louver and connecting up including provision of flexible copper wire three core of size 23/0.0076 from ceiling rose/PVC connector to exhaust fan all as specified.
Fixing only in repairs Energy efficient surface Mounted LED Luminire 18 watts 4' long, with acrylic cover complete with all accessories including necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr all as directed Note :- Light fitting will be issued under schedule 'B' store.
S & F in repairs Energy efficient surface Mounted LED Luminire 10 watts 2' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.5 mtr all as directed.
Supply & fix recess mounting high lumen LED flat panel 1' x 1' 18 Watt, white powder coated CRCA housing with highpower LEDs, aluminium front frame with flat white high transmission acrylic cover, internally prewired, 230V, complete with all accessories such as electronic driver, LED strip, connector block etc. and necessary fixing arrangement at any height and removing old unserviceable item complete all as specified and directed.
Taking down old unservicable CFL bulb and Supply and fix retrofit LED bulb 7/9/12W 240volts, 50Hz, including removing old unserviceable item complete all as specified and directed.
Taking down old unservicable tube light fitting and Supply & fix in repair Energy efficient surface Mounted LED Luminire 18 watts 4' long, with acrylic cover complete with all accessories incl necessary two core copper wire for connection from ceiling rose to connector of approx length 0.75 mtr all as directed.
S & F in repairs LED Aviation light comprising of aluminium housing with polycarbonate enclosure, 302 Nos. LED are provided with necessary fixing arrangements & electrical connections complete all as specified and directed by Engineer-in-Charge.
S & F in repairs 1 x 60 watts LED building security light made up of pressure die cast housing with toughned glass and individual LEDs with secondary optics and IP66 protection for building security lights all as specified.
M & L for Street light bracket made out of GI tubing 32/40 mm dia, light grade bend to shape suitable for below mentioned security light fitting with necessary MS clamps with one coat of red oxide and two coats of aluminium paint including nut, bolt, washers etc.
Taking down of existing UNSV flood light fitting of any type, supply and fix LED Flood light fittings 200 Watts including fixing arrangement and ncluding connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multistranded, necessary connections complete all as specified and directed by Engineer-in-Charge.
Taking down of existing UNSV flood light fitting of any type, supply and fix LED Flood light fittings 180 Watts including fixing arrangement and ncluding connections with 3 run of 2.5 Sq mm aluminium unsheathed wire multistranded, necessary connections complete all as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts,check nuts and washers of brass as shown in electrical plate No. 5 of SSR part I including necessary excavation and earth work, GI Pipe 20 mm bore light grade for watering with Funnel, wire mesh, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B 0 with 8 mm dia TMT bar and handle with lifting hooks, adequate quantity of charcoal dust and common salt etc including testing and taking out old unserviceable any type complete all as specified and as directed.
Taking down ceiling fan 1200/1400 mm sweep of any make from its existing position after disconnecting of electric connection for carrying out repairs including servicing, overhauling, greasing etc after cleaning the body internally and externally with cleaning agent including renewal of minor spare parts such as split pins, cater pins, coupling bolt, capacitor holder, terminal adoptor, screws, nuts and washers etc and replacement of spare parts/accessories such as ball bearings, gun metal bushes, capacitor, canopy top and bottom, shackle clip assembly, rewinding of fan motor, painting and including hanging / fixing back in existing location and making cable connections and testing for its satisfactory performance complete all as specified and directed.
All as per item No. 52.00 above, but of exhaust fan of size upto 300/380 mm sweep all as directed.
All as per item No. 52.00 above, but of exhaust fan of size 450 mm sweep all as directed. Note for item Nos. 52.00 to 54.00 :- (i) Spare parts will be measured and paid separately under relevant item of schedule as Supply only. (ii) Rewinding, painting will be measured and paid separetly under relevant item of schedule. (iii) Labour element for fixing of supply only spare parts and removing old unserviceable items are deemed to be included in quoted rate.
Supply only capacitor 2.5 mfd, 240 volts, 50Hz complete all as specified and directed.
Supply only capacitor 3.15 mfd, 240 volts, 50Hz complete all as specified and directed.
Supply only ball bearing suitable for ceiling fan /exhaust fan /air circulator/ pedestal fan any type
Supply only shackle clip assembly with rubber bush reel and nuts, bolts and washers suitable for ceiling fan of any sweep complete all as specified and directed.
Supply only PVC canopy top and bottom with tighten screw suitable for ceiling fan of any sweepcomplete all as specified and directed.
Supply only split pin as per sample suitable for ceiling fan all as directed.
Supply only MS nut bolt with split pin as per sample and as directed by Engineer-in-Charge.
Supply and fix down rod made of MS pipe medium grade 15mm dia of 300/450/600 mm long duly drilled holes both ends & slot with hole in other end suitable for fixing of ceiling fan of any sweep/type and painting to of down rod with two coat of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Supply and fix copper conductor cable 3 core; 0.75 sqmm, PVC insulated, sheathed, flexible, multistranded, 1100 volts grade for making connection to ceiling fan from ceiling rose complete all as specified and directed.
Supply and fix galvanised louvre shutter suitable for exhaust fan 300/380 mm sweep and fixing arrangement at out side of wall surface at any height complete all as specified and directed.
Supply and fix galvanised louver shutter suitable for exhaust fan 450 mm sweep and fixing arrangement at out side of wall surface at any height complete all as specified and directed.
Material and labour for painting to ceiling fan of any sweep complete body, blades and down rod with two coat of synthetic enamel paint similar to match with existing colour after preparation of surfaces by using electric spray machine including marking of MES Number with black paint complete all as specified and directed directed.
Material and labour for painting to exhaust fan complete body, blade assembly, frame of 300 mm sweep to 450 mm sweep with two coat of synthetic enamel paint by using electric spray machine similar to match with existing colour after preparation of surfaces including marking of MES Number with black paint complete all as specified and directed.
Material and labour for rewinding of ceiling fan motor of 1200/1400 mm sweep with new supper enamelled copper winding wire of existing gauge and number of turns and applying insulated varnish and assembling including removing burnt out copper winding wire complete all as specified and directed.
Material and labour for rewinding of exhaust fan motor of 300/380 mm sweep with new supper enamelled copper winding wire of existing gauge and number of turns and and applying insulated varnish assembling including removing burnt out copper winding wire complete all as specified and directed.
Material and labour for rewinding of exhaust fan motor of 450 mm sweep with new supper enamelled copper winding wire of existing gauge and number of turns and and applying insulated varnish assembling including removing burnt out copper winding wire complete all as specified and directed.
Removing old unserviceable blade assembly from exhaust fan and supply and fix new blade assembly suitable for exhaust fan 300/380 mm sweep and including locking nuts and testing complete all as specified and directed.
Removing old unserviceable blade assembly from exhaust fan and supply and fix new blade assembly suitable for exhaust fan 450 mm sweep and including locking nuts and testing complete all as specified and directed.
Prabha Electricals and Communications
Shree Ram Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .