Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.2 CrAccepted-AOC | ₹2.2 Cr | L-1 | Accepted-AOC As per TEC Report. |
| 2 | L-2₹2.6 Cr+₹42.7 L (19.8%)Rejected-Finance | ₹2.6 Cr+₹42.7 L (19.8%) | L-2 | Rejected-Finance As per TEC Report |
| 3 | L-3₹4.2 Cr+₹2.1 Cr (95.8%)Rejected-Finance | ₹4.2 Cr+₹2.1 Cr (95.8%) | L-3 | Rejected-Finance As per TEC Report |
Tender Value
₹1.9 Cr
EMD Value
₹3.9 L
Closing Date
26 Feb 2022, 6:55 pmClosed
DGM(Civil), PnC
Dy. General Manager (PnC) Parbati HE Project, Stage-II Parbati Complex, Nagwain Distt. Mandi (H.P) Pin - 175 121
Construction of fully underground cavern at Khab, Distt.- Kinnaur, Himachal Pradesh (Package No. C-645)
2022_NHPC_671994_1
NH/PP-II/PnC/Pkg.No.C-645/2022
Open Tender
Civil Works
Works
480 days
Khab, Distt-Kinnaur, H.P
Please refer tender document.
7 documents required · 7 mandatory
₹1,180
NHPC LTD.
₹3.9 L
Parbati HE Project,Stage-II.
18 Jun 2022
5 Feb 2022
4 Mar 2022
5 Feb 2022
26 Feb 2022
19 Feb 2022
12 Feb 2022
Amount
Survey and surface investigation
Topographical Survey for contour map at 2-5 m interval
Surface excavation at portals
Common Excavation
Rock Excavation
Underground Excavation
Excavation of Access Tunnel and Cavern-Very good, Good, Fair rock
Rock Stabilization & Supports
Rock Anchors 25 mm dia in surface work including accessories and testing of anchors -upto 2.5 m long
Rock Bolt 25 mm dia in Underground including accessories and testing of anchors - -upto 2.5 m in adit and 3 m in cavern
Wiremesh-Welded wiremesh
Steel ribs, supply & installation (including accessories)
Steel lagging: Supply & Installation
Precast concrete lagging (M25/A20)
Shotcrete
Plain Shotcrete -At portals
Plain Shotcrete -In Access Tunnels & Cavern
Extra for providing and mixing of Waterproofing material in shotcrete
Cement Variation
Backfill
Filling fine sand below invert concrete
Gravel filling around perforated PVC pipe
Drilling & Grouting for consolidation
Drilling of 45 mm dia. holes for consolidation grouting
Grouting operation for consolidation grouting
Cement for grouting
Concrete
Concrete lining including formwork in Tunnel & Cavern- M25A20 PCC in invert lining in access tunnel & Cavern
Concrete lining including formwork in Tunnel & Cavern- M25A20 Reinforced concrete in cavern in overt lining in access tunnel and cavern
M30 A40 Reinforced concrete in Portals
M15A40 Backfill Concrete access tunnel and Cavern
Extra for providing & mixing of Waterproofing material in concrete work
Cement Variation
Reinforcing Steel
Deformed Reinforcing bars Grade Fe 500
WATER PROOFING
Drainage board 500 gsm with 8 mm Dimple with prefixed Geotextile 100 gsm
Providing, laying & fixing of waterproofing Geo-Membrane PVC-P Type 2.0 mm thick
Providing, laying & fixing of protection sheet- Geo Textile 500 gsm
Providing, laying & fixing of protection sheet- PVC- 2 mm thick
Perforated PVC 75 mm Dia. Pipes
MISCELLANEOUS
Providing and fixing 2 mm thick M. S. sheet door with frame of 75 x 75 x 6 mm angle iron and 3 mm M. S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M. S. angels 75 x 75 x 6 mm for diagonal braces. With complete fittings and fixtures.
ELECTRICAL ITEMS
Flame proof Led Light Surface mounted/wall mounted 2x20 watt
Installation, testing & commissioning of lighting fixtures Fully enclosed
Underground Point wiring for Lighting fixtures with 2x2.5 mm copper cable + 1x2.5 cu earth wire & steel conduit
Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, double door 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without CB/RCCB/Isolator)
Supplying & fixing of ELCB in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kVA, "C" curve, miniature circuit breaker suitable for inductive load of 2 poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying & Fixing of 2P surge protection/ Lightning device in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Single stage axial fan and motor with suitable capacity to deliver at least 20 cum/sec maintaining minimum 200 mm static pressure for supply of air
Supply installation balancing and commissioning of GSS sheet metal rectangular/ round ducting complete with neoprene rubber gasket, elbows, splitter dampers, vanes, hangers, supports etc. with suitable cross sectional area graded with reducing size to maintain uniform pressure as per approved drawings and specifications of suitable sheet thickness (not less than 1.25 mm sheet) for seperate supply for eturn line to complete the system as required
MCC Panel suitable for axial fans & Motors with all necessary protection arrangements
Power Cables and Control Cables of suitable rating for ventillation system
Installation, erection and commissioning of complete ventillation system
H K S Construction
ALPHA PACIFIC SYSTEMS PVT. LTD.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .