Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹26.7 L+₹5,545 (0.21%)Rejected-Finance B XXIII 56 A PREM NAGAR SAINGARGH PATHANKOT 145001 PUNJAB | PATHANKOT | PATHANKOT | PUNJAB | 145001 | L2 | Rejected-Finance Other than L1. | |
| 3 | L3₹27.0 L+₹30,800.80 (1.16%)Rejected-Finance 254 GOVT HOUSING COLONY CHANNAPORA SRINAGAR 190015 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190015 | L3 | Rejected-Finance Other than L1. |
Tender Value
₹29.3 L
EMD Value
₹58,660
Closing Date
20 Apr 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Wks Engrs
HQ 134 Wks Engrs PIN 914134 C/o 56 APO
SPL REPAIR REPLACEMENT OF HT OCBs WITH VCBs AT KHUNMOH GARRISON UNDER GE 861 EWS.
2023_MES_586956_1
134 WE-102(T)/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Srinagar
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 861 EWS
₹58,660
Yes
3 May 2023
24 Mar 2023
22 Apr 2023
24 Mar 2023
20 Apr 2023
7 Apr 2023
24 Mar 2023 - 30 Mar 2023
Amount
Supply, laying and testing in repair of HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sqmm, complete all as specified and directed.
(vi) Microprocessor based numerical non-directional IDMT/DT 30/C+1E/F relay. (vii) Master high speed tripping relay suitable for 30V DC. (viii) LED indicating lamp for circuit breaker on /Off, trip circuit healty and spring charged. (ix) Space heater with switch 230 AC. (x) Alarm bell 30V DC against over current & earth fault. (xi) Push button for alarm cancelled. (xii) Breaker control switch. (xiii) Thermostat. (xiv) 3 Pin socket with Switch. (xv) Ilumanting lamp 230V. (xvi) HRC fuse with links as per site requirement. (xvii) Terminals for CT/PT CKT. Note :- Panel should be suitable for 25 KA, 1 Sec internal arc test.
Excavating in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for foundation of poles/stay/cables etc including getting out in any type of soil, complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard and dence soil, complete all as specified and directed.
Removing excavated surplus soil to a distance not exc. 50m and depositing where directed at a level not exc. 1.5 mtr above the starting point, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable after laying, complete all as specified and directed. Note :- Punned thickness of sand shall be measured & paid.
Supplying and laying in replacement un-reinforced precast concrete cable cover, class HVP, type 2, with peak, size 450mm x 180mm x 40mm, complete all as specified and directed.
M&L for GI tubing, light grade, galvanised 100mm dia with clamps, nuts, bolts for protection of UG cable on poles, wall, crossing of nalla, bridge etc, complete all as specified and directed.
S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm, complete all as specified and directed.
M&L for disconnection/removal/shifting of old OCB from the existing site and deposited to MES store, complete all as specified and directed.
M&L for earthing complete with copper earth plate of size 60cmx60cmx3.15mm thick electrode, burried directly in ground (earth pit not less then 2.25 metres deep below ground level) with top edge of the plate not less then 1.5 metre below normal ground level, conneceted to copper strip of size 20x3mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 and incl earth work, PCC pit and RCC cover, watering pipe 20mm dia light grade, funnel, wire mesh, charcoal dust, 40mm dia light grade protection pipe and salt etc. and connected to earthing test point, complete all as specified, directed and testing after completion. Note :- (a) On testing after completion of earthing if the desired earth resistance is not obtained earthing will be re-done by the contractor at his own risk and cost. (b) On testing after completion if the desired resistance is not obtained the contractor shall re-do the earthing without any extra cost to the department.
SATISH AND CO
M/S Sky Engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .