| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | ₹8.6 L Quoted ₹9.3 L | L1 | Accepted-AOC Accepted |
| 2 | L2₹9.8 L+₹47,740 (5.12%)Rejected-AOC | ₹9.8 L+₹47,740 (5.12%) | L2 | Rejected-AOC Rejected |
| 3 | L3₹10.0 L+₹64,397 (6.91%)Rejected-AOC | ₹10.0 L+₹64,397 (6.91%) | L3 | Rejected-AOC Rejected |
| 4 | L4₹11.7 L+₹2.4 L (25.8%)Rejected-AOC | ₹11.7 L+₹2.4 L (25.8%) | L4 | Rejected-AOC Rejected |
| 5 | L5₹13.6 L+₹4.3 L (46.0%)Rejected-AOC 150 BC LINE MALL ROAD MEERUT CANTT 250001 | MEERUT | UTTAR PRADESH | 250001 | ₹13.6 L+₹4.3 L (46.0%) | L5 | Rejected-AOC Rejected |
Tender Value
₹21 L
EMD Value
₹42,000
Closing Date
9 Nov 2022, 6:00 pmClosed
Garrison Engineer (N) Mamun
Garrison Engineer (N) Mamun
Repair maintenance of ceiling fan exhaust fans Wall mounted fans meter and geysers point wiring work etc under AGE EM I of GE N Mamun
2022_MES_557309_1
GE(N)/M-31/2022-23
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer (N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (N) Mamun
₹42,000
16 Dec 2022
12 Oct 2022
11 Nov 2022
12 Oct 2022
9 Nov 2022
26 Oct 2022
Amount
Servicing of ceiling fans of capacity 1200/1400mm including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws of suitable size, fan canopy set and ensuring all blades screwed properly before refixing incl replacement of PVC fan box round sheet on ceiling and making electric connection with flexible copper conductor of size 3core 0.50Sqmm complete all as specified and directed. Note: 1. Servicing of ceiling fan will be done at site. 2. Rewinding and unserviceable parts other than specified in this item if any will be measured saperately
Taking out burnt winding wire by cutting, cleaning slots and re-winding of AC ceiling fan motor 1200mm sweep any make with super enameled colour copper winding wire of gauge 35SWG including, sleeve work, varnishing with F class insulation paper with threading complete all as specified and directed. Note:- 1. Total weight of winding wire should not be less than 200gm. 2. Rewinding of fan motor will be done at workshop. Make of winding wire: BIC/ Devidyal or equivalent make as per command approved list.
All as per Srl item No 02 here-in-above but for size 1400mm sweep.
Servicing of Exhaust fans of size upto 450mm sweep including taking down from site, dismantling, cleaning, greasing/oiling of bush and bearings, replacement of set of split pins, cotter pins, blade screws of suitable size and ensuring fan blades screwed properly before refixing and making electric connection with flexible copper conductor od size 3core 0.50Sqmm complete all as specified and directed. Note: 1. Servicing of ceiling fan will be done at site. 2. Rewinding and unserviceable parts other than specified in this item if any will be measured saperately
Taking out burnt winding wire by cutting, cleaning slots and re-winding of exhaust fan motor 250/300mm sweep with super enameled copper winding wire of gauge 35SWG including sleeve work, varnishing with E class insulation varnish, threading complete all as specified and directed.
All as per Srl item No 5 here-in-above but of size 450mm sweep.
Dismantling and taking out burnt winding wire by cutting, cleaning slots and re-winding of AC wall mounted fan motor 400mm/600mm sweep with super enameled colour copper winding wire of gauge 35SWG including, sleeve work, varnishing with F class insulation paper with threading, including blade screws of suitable size and ensuring all blades screwed properly before issuing to concerned unit complete all as specified and directed.
Supply only for replacement of old unserviceable gun metal bush of ceiling fan of size 1200/1400mm sweep as per existing size complete all as specified and directed.
Supply only for replacement of old unserviceable capacitor AC 440 volts 2.5 mfd with copper wire terminal incl PVC clamp complete all as specified and directed. Make: Havells/Bajaj/Usha.
All as per Srl item No 9 Above but of rating 3.15mfd.
All as per Srl item No 9 Above but of rating 4.0mfd.
Supply only for replacement of old unserviceable ball bearing of size 6201. Make:- SKF or NBC or any other equivalent make.
All as per srl item No 12 Above but for size 6202.
All as per srl item No 12 Above but for size 6203.
Supply only for replacement of old unserviceable shackle assy kit (rubber real -01, MS split clamp -02 Nos, nut ,check nut,spring washer, bolt not less tha 6.0mm dia & split pin -02 Nos) suitable for ceiling fan 1200/1400mm sweep complete all as specified and directed.
Supply only for replacement of old unserviceable ceiling fan blades made of MS sheet duly powder coated of thickness not less than 1.0mm suitable for 1200mm sweep ceiling fan as per site requirement complete all as specified & directed.
All as per Srl Item No 16 here-in-above but suitable for ceiling fan 1400mm.
Supply only for replacement of old unserviceable ceiling fan down rod of length 30cm made of MS tubing of suitable dia, heavy duty complete all as specified.
All as per Srl item No 18 above but of length 45cm.
All as per Srl item No 18 above but of length 60cm.
Supply only for replacement of old unserviceable fan blades made of MS sheet duly powder coated of type, make and colour as of existing exhaust fan suitable for size 300mm sweep as per site requirement complete all as specified.
All as per Srl item No 21 above but of size 450mm sweep.
Supply & fixing in replacement of thermostat ISI marked suitable for geysers upto 50 Ltrs Capacity of type as per site requirement. The adjustable range shall be 0-75 degree celsius complete all as specified an directed.
Supply & fixing in replacement replacement of old unserviceable 6 Hole syphon assembly made out of Stainless steel suitable for 25/50 ltrs capacity geyser including necessary studs, screws and rubber gasket/washers complete all as specified and directed. Make: Theeta, Elcon, Heatking
All asper Srl item No 24 above but for 9Hole assembly.
Supply & fixing in replacement of heating element titanium coated ISI Marked of 1.5 KW rating round or triangular incl rubber washers suitable for water heater storage of size 25/50Ltrs complete all as specified . Make: Theeta/Elcon/Heatking/Airex
All as per Srl item No 30 above but of rating 2.0KW.
Taking down carefully geyser 25 ltrs capacity from wall after unscrewing nuts/bolts etc and replacing old unserviceable glass lined stainless steel Internal tank incl refixing the geyser in original position complete all as specified and directed. Notes: (i) The tank shall be tested at site and shall be able to withstand water pressure of 8bar.
All as per Srl item No. 28 here-in-above but 50 Ltr capacity.
Supply & fixing in replacement of old unserviceable stainless steel braided flexible connection pipe with GI hexagonal adopters/nuts on both sides, 15mm bore (300mm long) complete ISI marked, suitable for cold & hot water upto 0-80 degree celcius complete all as specified and directed make as approved.
All as per item Srl No 30 Above but of length 450mm.
Supply & fixing in PVC insulated and PVC sheathed cable 3 core 2.5 Sq.mm flexible stranded all as specified and directed. Make : Plaza/Grandlay/Finolex.
Supply & fixing in 3 Pin Plug Top 16Amps stranded all as specified and directed.
Supply & fixing in Switch socket combination 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete all as specified and directed.
M&L for stepped type electronic fan regulator on the existing phenolic laminated sheet etc. not less than 100 W flush type.
Supply & fixing in Fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 120W- 1 or 2 module including necessary connections complete all as spd and directed.
M&L for carbon steel anchor bolts, nut and washer of size 12mm dia & 80mm length by grouting in wall complete for mounting Geyser of any size all as specified and directed
M&L for fixing Ventillating fan of sweep 250mm sweep incl cutting square section of suitable size on existing wall fixing ventillating fan with suitable size of nuts bolts, connecting with 3core flexible copper conductor of 0.50 sq mm and making good to disturb surface of wall/floor with cement mortar and finishes to match existing surface complete all as specified and directed .
Supply & fixing in Exhaust fan louver round shaped made of MS steel sheet for exhaust fan of size 300mm sweep and fixing on wall by means of suitable size of screws incl taking down old unsv louvers complete all as specified and directed.
All as per item Srl No 39 above but for size 450mm sweep.
Supply & fixing in metal clad plug , socket and top 20Amps, 2P+E complete all as specified.
Taking down carefully unsv copper/aluminium point wiring (light/fan/Bell/socket or power) complete, including fixture and fittings such as switches, sockets, ceiling rose, lamp holders, brackets, pendent, regulators, sketch fitting etc removing materials to store for keeping in safe custody for taking credit and making good to disturb surface of wall/floor with cement mortar and finishes to match existing surface complete all as specified and directed.
M & L for point wiring using 3 x 1.5 Sqmm FRLS PVC insulated unsheathed /multi stranded copper conductor cable (Phase, neutral and earth wire) drawn through and incl concealed conduit medium grade of dia not less than 20mm and 1.8mm thick with all accessories and connected to common earth dolly with approved make sunken modular metal flush gang box (16gauge) and suitable support frame and cover plate (inner/outer) of required modules including cutting grooves for concealed wiring for light/fan point controlled by one 1way swtich complete all as specified and directed. Note: 1. Conduit shall be fixed on surface of ceiling with necessary saddles where concealing of conduit is not feasible. 2. Connections of cable with MCBs or switch/sockets shall be done through proper size copper/brass pin/U type thimbles.
All as per Ser item No 43 here in before but for one 5 Amp socket outlet point on same board controlled by one switch 5 Amp one way.
All as per Ser item No 43 here in before but for one 5 Amp socket outlet points controlled by one switch 5 Amps one way on independent board.
All as per item No. 43 here in before but for one above but one 15Amp socket point concealed with 3x2.5Sqmm FRLS PVC insulated multi-strand copper conductor.
M & L for point wiring using 3 x 1.5 Sqmm FRLS PVC insulated unsheathed /multi stranded copper conductor cable (Phase, neutral and earth wire) drawn through existing conduit and connected to common earth dolly with approved make sunken modular metal flush gang box (16gauge) and suitable support frame and cover plate (inner/outer) of required modules for one light/fan point controlled by one 1way switch complete all as specified and directed. Note: 1. Connections of cable with MCBs or switch sockets shall be done through proper size copper/brass pin/U type thimbles.
All as per Ser item No 47 here in before but for one 5 Amp socket outlet point on independent board controlled by one switch 5 Amp one way complete all as specified and directed.
All as per Ser item No 47 here in before but for one 5 Amp socket outlet points controlled by one switch 5 Amps one way on same board complete all as specified and directed.
All as per Ser item No 47 here in before but for one above but one 15Amp socket point with 3x2.5Sqmm FRLS PVC insulated multi-strand copper conductor complete all as specified and directed.
S&F modular switch one way 10 Amp one module, front operated complete all as specified and directed.
S&F socket modular socket 10 Amp, 2/3 Pin combined multipurpose, 2 module, complete all as specified and directed.
S&F modular switch piano type flush button single pole 16 Amp one module, front operated complete all as specified and directed.
S&F socket in replacement modular socket 6 Amp/16 Amp, 2/3 Pin multipurpose, 2 module, complete all as specified and directed.
S&F fan regulator modular step type suitable for 1200/1400mm sweep ceiling fan hum free, 120W- 2 module including necessary connections complete all as specified and directed.
S&F in ceiling rose PVC/polycarbonate, insulated body surface Bakelite 65mm dia three terminals complete all as specified and directed.
Taking down carefully unsv copper/aluminium sub main wiring of any size including old broken steel/PVC conduit and removing materials to store for keeping in safe custody for taking credit incl making good the distured surface and matching with existing specifications complete all as specified and directed.
S&F in replacement sub Main Wiring with two single core FRLS PVC insulated unsheathed multistranded flexible copper conductor cable of size 2x4 Sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor 4 Sqmm size (green colour) cable as earthing lead connecting to main earthing dolly drawn in and including PVC concealed conduit medium grade of dia not less than 20mm and 1.8mm thick with all accessories complete all as specified and directed.
All as per Ser Item no 58 here in before but of size 2x6 Sqmm.
S&F in replacement Energy saving, surface mounted, bulk head LED luminaire 10 W with PDC aluminium housing and polycarbonate diffuser complete including connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
S&F in replacement box type surface mounted 2x2 LED 36 watt luminaire warm white with white powder coated CRCA housing with LEDs. Seamless front frame with white coloured flat acrylic cover with inhouse driver and efficacy≥120Lm/W, CRI>80 with 5700+/-300K CCT including connecting up with 3 core flexible copper conductor cable of suitable size complete all as specified and directed.
All as per srl item No 61 here in before but for 1x1 LED 24 watt luminaire.
S&F in replacement surface mounted 18Watt round/square LED panel warm white having polycarbonate housing and high qaulity diffuser, inbuilt driver, efficacy ≥120Lm/W, CRI>80 with 5700+/-300K CCT complete with locking arrangement complete all as specified and directed.
S & F in replacement SPN MCB DB 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 43 and IK 09 rating having fully insulated copper busbar of rating not less than 100Amps, insulated neautral bar, earth bar and cable ties for cable management including polyuthrene gasket complete all as specified and directed.
S&F in replacement MCB SP 240V, 50Hz of rating 6 to 32 Amp with breaking capacity of 10 kA having bi-connect terminals on the bottom terminals for looping and 35Sqmm termination capacity on both terminals with insulated sliding shutters and two position DIN rail clamp for easy mounting complete all as specified and directed.
All as per Ser item No 65 here in before but for size 32 Amps MCB SPN.
All as per Ser item No 65 here in before but for size 40-63 Amps MCB SPN.
M&L for fixing sheet metal enclosures double door VTPN MCB DB 4 way 415 V AC, 50 Hz with IP 43 and IK 09 protection having fully insulated copper busbar of rating not less than 250Amps, insulated neutral bar, earth bar and cable ties for cable management and polyuthrene gasket and refixing of existing serviceable MCCB and MCBs and flush mounting into the wall and making good the disturbed surface and matching with the existing specification incl taking down old unsv DB any size any type complete all as specified complete all as specified and directed.
S&F in replacement driver for LED 36watt recess/surface mounted lights of make as per site requirement including connecting up with flexible copper conductor cable of suitable size complete all as specified and directed.
S&F LED street light with pressure die cast aluminium housing with toughned glass cover, lens type LED with system efficacy > 100 lumen/W , minimum 3000 system lumens, system wattage≤30W (including driver), color temperature 5700±300K, CRI>80, IP65 protection, IK07 rating. The potted electronic driver with THD<10%, PF>0.95. LED fitting is complete all as per OEM specified and directed. Manufacturer name should be embossed on light fitting. The light fitting system must comply the IS standards incl GI bracket of suitable dia bend to shape and fixed to wall by means of clamps or nuts bolts and connecting up with three core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
Taking out of electric meters 1Phase/3Phase and removing the burnt links, thimbles, connection wire and refixing at same location incl replacing burnt link, 3 run of PVC insulated FRLS copper wire of suitable size for connection from MCB to Meter with Pin type brass thimbles of suitable size complete all as specifed and directed.
Deduct Total amount of SCH 'A' SECTION-II (SCH OF CREDIT) Rs. 68169.00 ( to be deducted from Schedule ‘A’ (BOQ) to arrive at the Contract Sum)
KULBHUSHAN AGGARWAL
KONARK ENTERPRISES
M/S PRAJAPATI ENGINEERS
VIRAT CONSTRUCTIONS
PAWAN KUMAR GOVT. CONTRACTORS
Khurl Construction Co.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .