| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.1 Cr+₹313.70 (<0.01%)Rejected-Finance | ₹1.1 Cr+₹313.70 (<0.01%) | L2 | Rejected-Finance L2 |
| 3 | L3₹1.1 Cr+₹4,036.42 (0.04%)Rejected-Finance VILL NARABARI P O P S DIST KOKRAJHAR PIN 783370 | KOKRAJHAR | ASSAM | 783370 | ₹1.1 Cr+₹4,036.42 (0.04%) | L3 | Rejected-Finance L3 |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
25 Mar 2022, 2:00 pmClosed
SE PWD Kokrajhar Bldg circle Kokrajhar
O/o the SE PWD Kokrajhar Bldg circle Kokrajhar
Expeditious Installation of PSA Oxygen Generation Plant in Assam for COVID-19 Pandemic Providing Civil Electrical and Oxygen Pipeline Works at JSB Civil Hospital in Chirang District BTC Assam for the financial year 2021-22 TN-603
2022_BoTC_24653_1
TECH- 17/SE(B)/E-Tender/2021-22/
Open Tender
Civil Works - Building
Works
180 days
Chirang
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,292
The Principal Secretary, BTC Kokrajhar
₹2.2 L
Yes
12 Apr 2022
10 Mar 2022
28 Mar 2022
10 Mar 2022
25 Mar 2022
10 Mar 2022
10 Mar 2022 - 25 Mar 2022
Amount
(A) Construction of Plastfrom with Shed for Three Nos. DG Set.: Earth work in excavation by mechanical means (Hydraulic excavator)/Manual means in foundation trenches or drains (not exceeding 1.5m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50m. 2.8.1 All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level. 4.1.5-1:3:6 (1 cement: 3 coarse sand (zone-III): 6 graded stone aggregate 20 mm nominal size)
Steel reinforcement for RCC work including straightening cutting bending placing in position and binding all complete upto plinth level. 5.22.6 Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for: 5.9.1 Foundations, footings, bases of columns, etc. for mass concrete.
Lintels, beams, plinth beams, girders, bressumers and cantilevers.
Suspended floor, roofs, landings, balconies and access platform.
Providing and laying on position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement All work up to plinth level: 5.1.2-1:1.5:3 (1 cement: 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Brick work with common burnt clay F.P.S (non modular) bricks of class designation 7.5 in foundation and plinth on: 6.1.1 Cement mortar 1:4 (1 cement: 4 coarse sand)
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement: 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size)
Half brick masonary with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement: 4 coarse sand)
15mm cement plaster on the rough side of single or half brick wall of mix: 13.2.1-1:4 (1 cement: 4 fine sand)
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. 10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. ii) Single leaf Iron Gate 2 Nos.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. 10.16.1- Hot finished welded type tubes.
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50mm (+0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportaion and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5 x 55mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surface, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting mix 1:2 (1 cement hardener mix: 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufactures's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and applying plaster of paris putty of 2mm thickness over plastered surface to prepare the surface even sand smooth complete.
Finishing walls with Acrylic Smooth exterior paint of required shade 13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/stell works
Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface etc. complete. 13.52.1 On steel work
(B) Cost for Medical Gas Pipe Line System: Supply, installation testing & commissioning of Oxygen Outlets with matching probes, CE certificate with four digit notafied number as per enclosed technical specification and approved make- (imported)
Supply, installation testing & commissioning of Oxygen Flowmeter with Humidfier Bottle CE certificate with four digit notafied number/UL Listed as per enclosed technical specification and approved make- (imported) for critical area)
Supply, installation testing & commissioning of Vacum outlets with matching probes, CE certificate with four digit notafied number as per enclosed technical specification and approved make- (imported)
Supply, installation testing & commissioning of Ward Vacuum unit CE certificate as per enclosed tender specification and approved make.
Supply, installation testing & commissioning of Medical Grade BS EN: 13348 LLOYD marked copper pipe 12mm
Supply, installation testing & commissioning of Medical Grade BS EN: 13348 LLOYD marked copper pipe 15mm
Supply, installation testing & commissioning of Medical Grade BS EN: 13348 LLOYD marked copper pipe 22mm
Supply, installation testing & commissioning of Medical Grade BS EN: 13348 LLOYD marked copper pipe 28mm
Supply, installation testing & commissioning of Medical area Line Pressure Alarm as per HTM 2022/02-01/NFPA99C as per enclosed technical specification and approved make area line pressure Alarm 2 gases.
Supply, installation testing & commissioning of Medical area Value service unit (avalve box with isolation value) as per CE certificated/UL listed as per enclosed technical specification and approved make 2 Gases
Supply, installation testing & commissioning of Aluminum extruded Bedhead Panel long three feet with electrical & provision of gas outlet as per enclosed technical specification and approved make
(C) Repair/Renovation of Oxygen Bedded Cabins and Wards: Half brick masonary with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. 6.13.2 Cement mortar 1:4 (1 cement: 4 coarse sand)
15mm cement plaster on the rough side of single or half brick wall of mix:13.2.1-1:4 (1 cement: 4 fine sand)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber/neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge (Cost of aluminium snap beading shall be paid in basic item): 21.3.2 With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water bsorption less than 0.08% and conforming to IS:15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. complete. 11.41.2 Size of Tile 600x600 mm
Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufactureer, of required shade and colour complete, as per manufacture's specification. 13.42.1 Two or more coats on new work.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: 13.43.1 Water thinnable cement primer.
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. 17.3.1 W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. Brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets cutting and making good the walls and floors wherever required: 17.4.3 Range of three urinal basins with 10 litre white PVC automatic flushing cistern
Providing and fixing wash basin with C.I. Brackets, 15mm C.P. Brass pillar taps, 32 mm C.P. Brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630 x 450 mm with a pair of 15 mm C.P. brass pillar taps.
Providing and fixing 600 x 450 m beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. Brass screws and washers complete.
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 17.73.1. 450mm long towel rail with total length of 495 mm, 78mm wide and effective height of 88mm, weighing not less than 170 gms
Providing and fixing C.P. Brass shower rose with 15 or 20 mm inlet: 18.22.1 100 mm diameter
Providing and fixing Chlorinated Polyviny Chloride (CPVC) pipes, having thermal stability fro hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge. Concealed work, including cutting chases and making good the walls etc. 18.8.3. 25 mm nomonal outer dia pipes
Providing and fixing Chlorinated Polyviny Chloride (CPVC) pipes, having thermal stability fro hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge. Concealed work, including cutting chases and making good the walls etc. 18.8.2. 20 mm nomonal outer dia pipes
Providing and fixing Chlorinated Polyviny Chloride (CPVC) pipes, having thermal stability fro hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-charge. Concealed work, including cutting chases and making good the walls etc. 18.8.1. 15 mm nomonal outer dia pipes
Providing and fixing Chlorinated Polyviny Chloride (CPVC) pipes, having thermal stability fro hot & cold water supply, including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge. 18.9.8. 75mm nomonal inner dia pipes
Providing and fixing Chlorinated Polyviny Chloride (CPVC) pipes, having thermal stability fro hot & cold water supply, including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer-in-charge. 18.9.9. 100mm nomonal inner dia pipes
(D) Electrical Works: Wiring of circuit/submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.1 2 x 1.5 sq.mm+1x1.5 sq.mm earth wire
Wiring of circuit/submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.2 2 x 2.5 sq.mm+1 x 2.5 sq.mm earth wire
Wiring of circuit/submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.3 2 x 4 sq.mm+1 x 4 sq.mm earth wire
Wiring of circuit/submain wiring alonwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required. 1.14.5 2 x 10 sq.mm+1 x 6 sq.mm earth wire
Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.54.2 Group B
Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit, and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1.54.3 Group C
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residental buildings)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 2.1.1. 32 A TP&N
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 2.1.2. 63 A TP&N
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. 2.2.2. 125 A, 16 KA, TPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. 2.2.6. 250 A, 25 KA, TPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. 2.2.9. 400 A, 35 KA, TPMCCB
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/recess, complete with tinned copper bus bar, netural bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2.3.2. 8 way, Double door.
Supplying, installation on wall, testing and commissioning of following capacity Air Insulated Compact Type Rising Mains for use on 3 phase 4 wire 415 volts, 50 Hz A.C. Supply with enclosure having IP-54 rating after fixing the tap off boxes and all accessories, made of 1.6mm thick steel sheet duly powder coated in convenient sections complete with 4 Nos aluminium bus bars having current density of 130 A/ sq cm at nominal current rating, necessary joints & expansion joints, fire barrier at each floor, provision of tapping at every metre, continuous earthing with 2 Nos aluminium strip of suitable size (one oneach side) including G.I.clamping brackets, angle iron bracket, steel fasteners, connecting to earthing system etc. as required. 3.8.3. 400 A Isc=30KA for 1 second.
Earthing with G.I. Earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/coke and salt as required.
Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm x 5mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.1. Upto 35 sq.mm
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. 7.1.2. Above 35 sq.mm and upto 95 sq.mm
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE powder cable of 1.1 KV grade of following size on wall surface as required. 7.7.2 Above 35 sq.mm and upto 95 sq.mm (clamped with 25x3mm MS flat clamp)
Laying and fixing of one number PVC insulated and PVC sheathed/XLPE powder cable of 1.1 KV grade of following size on wall surface as required. 7.7.4 Above 185 sq.mm and upto 400 sq.mm (clamped with 40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 9.1.6. 2 x 50 sq.mm (28mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 9.1.12. 3 x 70 sq.mm (35mm)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required. 9.1.27. 3 1/2 x 185 sq.mm (57mm)
Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. 14.16.5. 200mm dia (OD-200mm & ID-175mm nominal)
Supplying with installation & commisioning of ready made maintenance free CPRL approved chemical earthing system with 100 mm dia, 2.9 Metres length corrosion free centrifugally Cast Iron Earthing Electrode complete with Reslow/BFC Grounting chemical compound (40 kg) and advance earth pit (CI) of size 300 mm x 300mm including excavation of earth pit and construction brick earth chamber including platering both inner & outer surface of brick wall as specified and directed by the deptt. 100 mm dia chemical earthing
Supplying including testing and commisioning of Water Cooled Diesel Generator set coupled complies with current CPCB-II emission norms to suitable alternator of 220/415 V, AC, 1/3-Phase 0.8p.f. mounted on a (1) M.S. Fabricated base frame (2) M.S. fuel tank of required capacity (3) Residual Slincer (Stack high shall be minimum 6.0 mtr. above the building where the gen set is installed (4) AMF Control Panel (5) Suitable batteries with lead (6) First fill of lube oil (7) Acoustic enclosure complete with all accessories as specified and directed by the department conforming to IS comprising the Technical Specification as per manufacturer (RANGE FROM 5 KVA TO 625 KVA, Kirloskar KOEL, Greaves, JAKSON, Mahindra or equivalent alternator. (160 KVA Liquid Cooled III Phase with Std Panel Silent Diesel Generator Set).
Supplying including installation of UPS 2 KVA On-Line UPS System (Orion or equivalent make as approved by the Deptt.) with PWM-IGBT technology 230 V AC Input (160V-280V A 1 Ph input- 1 Ph output with isolation transformer 0.8 KW output with 0.8 output PF 60 min backup using SMF battery.
Supplying installation & commissioning of 3-phase 250 KVA servo stabilizer 360V to 460V oil colled voltage regulation.
Supplying with installation of testing and commissioning of Hi-wall 5 star rating split type air conditioner of following capacity with cordless remote complete with copper pipe and electrical connection etc. as required complete and as directed by the Department. 2.2 Ton capacity (Model-Sprint, Voltas SAC 24H SZS)
Supplying with including fitting fixing of ceiling fan etc. as directed by the Deptt. (USHA make 1200mm)
Supplying with including fitting fixing of Exhaust Fan etc. as directed by the deptt. (USHA make 1200mm)
Supplying with including fitting fixing of LED Tube light etc. as directed by the deptt. 20 watt. (Complete Set) Bajaj Make.
Design, fabrication & supply of floor mounted outdoor type compartmentalized dust and vermin proof powder receiving panel board (L.T-3 ph, 415 V, AC, 400 Amp) made of M.S. Sheet of not l;ess than 16 swg duly welded & powder coated with grey colour to both in interior & exterior. The panel board will be comprises with the materials like MCCB 400A 4P (with rotary handle), Busbar etc.
Supplying with laying U.G. Cable (HAVELLS BRAND) L.T. Power Cables, Copper Conductor up to 6 sq.mm & Balance Stranded Copper, XLPE Insulated Coress Laid up, PVC Innersheathed, Unamoured/Armoured (Galvanised wire for cbles up to 10 x 1.5 sq.mm. 2 x 10 sq.mm, 3 x 10 sq.mm, 4 x 6 sq.mm & blance all galvanised steel strip) Extruded PVC Type ST2 Outer Sheathed, 650/1100 V Grade as per IS 7098 (Part-I) 1988 with up to Date Amendments including trenching, sand chusioning Brick protection and refilling the trench as specified and directed by the Department. 50.00 Sq.mm Single Core.
Supplying with laying U.G. Cable (HAVELLS BRAND) L.T. Power Cables, Copper Conductor up to 6 sq.mm & Balance Stranded Copper, XLPE Insulated Coress Laid up, PVC Innersheathed, Unamoured/Armoured (Galvanised wire for cbles up to 10 x 1.5 sq.mm. 2 x 10 sq.mm, 3 x 10 sq.mm, 4 x 6 sq.mm & blance all galvanised steel strip) Extruded PVC Type ST2 Outer Sheathed, 650/1100 V Grade as per IS 7098 (Part-I) 1988 with up to Date Amendments including trenching, sand chusioning Brick protection and refilling the trench as specified and directed by the Department. 70.00 Sq.mm Single Core.
Supplying with laying U.G. Cable (HAVELLS BRAND) L.T. Power Cables, Solid Aluminum Conductor up to 10 sq.mm & Balance Stranded Copper, XLPE Insulated Coress Laid up, PVC Inner sheathed, Unamoured/Armoured (Aluminium wire for single core up to 70 sq.mm. & blance aluminum strip, galvanised wire for cables up to 2 x 10 sq.mm, 3x10 sq.mm, 4 x 6 sq.mm & balance all galvanized steel strip) Extruded PVC Type ST2 Outer Sheathed, 650/1100 V Grade as per IS 7098 (Part-I) 1988 with up to Date Amendments including trenching, sand chusioning Brick protection and refilling the trench as specified and directed by the Department. 185 Sq.mm 3 1/2 Core.
KEMENDRA KUMAR BRAHMA
TAPAN KUMAR BASUMATARY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .