Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹96.8 L
EMD Value
₹1.9 L
Closing Date
13 May 2024, 5:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Accessories Division, Lucknow
HINDUSTAN AERONAUTICS LIMITED Accessories Division, Lucknow Post Office, Lucknow - 226 016 Uttar Pradesh, India
Fabrication Work and Laying of pipeline of FCU Rig.
7185
HAL-ADL/EQUIP/NSE/JAGUAR/23-24/CWA-24OT/2
Works
Accessories Complex - Lucknow Divn - Plant Maintenance
₹0
₹1.9 L
13 May 2024
29 Apr 2024
29 Apr 2024
13 May 2024
Tender No : HAL-ADL/EQUIP/NSE/JAGUAR/23- 24/CWA-24OT/2 dtd : 26.04.2024
Name of the work: Fabrication Work & Laying of Pipeline of FCU test rig.
( SCOPE OF WORK)
Sl No Work Description Qty Unit Rate (Rs/Unit) Total (Rs)
Fabrication and Installation of FCU Test Rig SS pipe lines along with installation of following components of the circuit as per test rig drawing attached at annex -1a, 1b, 1c. The detailed list of components to be installed in the system which are under HAL’s Scope is attached at annex 2.
1 Supply and Installation of main panel and mounting on all equipment on panel of the rig( Refer Drawing at Annex 3): The work will include the fabrication of panel as per drawing at annex 3 and installation of the same to mount all the equipments of the testing rig as per drawing .All the equipments like pressure gauges , Valves , Rotameters,Electronic readouts (for temp ,Differential Pressure ,RPM ,flow etc), DC drive, Hydraluc supply and return outlets for hoses, Various switches , Bulbs , etc to be mounted on the Panel. All the items will be mounted properly and will be screwed on the panel as per mounting instructions .No vibration, looseness, misalignments should be there. The panel will be painted as per given standard and will be leveled as per given instruction. The panel needs to be rust free, spray painted, robust and vibration free & give aesthetic look along to the rig. A proper drain connection as per drawing to be provided on SS tray of the panel to collect the drain from the unit during opening of the connections and drain point to be connected with main drain line. 1 Job
2 Supply and installation of SS Tank with stand (Refer Item No 1 in Test Rig Drawing at Annex-1a & SS tank Drawing at Annex 4): The SS tank to be supplied and installed as per drawing at Annex -4 with all required connections. The tank will be grouted firmly on ground through fastners for no vibration during testing. The proper leveling will be done at each connection. The tank should be buffed from outside to giving shining and aesthetic look. Proper connections for supply line, return line, ATF filling line, Drain Line and Sample check line should be made as per drawing at Annex 4.A breather should be provided at the top side of the tank as per drawing. The top flange should be welded in such a way that there should not be any bulging of tank neck .Also the flange after welding should be perfectly horizontal and sealed after tightening . 1 Job
3 Installation of Power pack (Ref Item No 31 in Test Rig Drawing at Annex-1a) : The work will include positioning of motor pump and drives on location , grouting , and installation of the power pack with connection to SS supply , return and drain lines as per drawing. There the pump to be aligned with plummer block of approximate 1.2 m long with in 50 Micron for running smoothing at higher RPM without vibration. The plummer block, Motor and Pump to be aligned with in 100 micron. Proper shimming of motor and plummer block to be done to maintain required alignment. The plummer block will be provided by vendor to connect pump with motor. All the shim to be provided by vendor. The motor will perform up to 5000 RPM. 1 Job
4 Installation of Heat Exchanger (Ref Item No 12 in Test Rig Drawing at Annex-1a): The work will include positioning and installation of heat exchanger on wall with proper grouting and connection with SS line and chilled water lines. The SS stray to be fabricated and installed beneath the heat exchanger to collect the water from pipe during opening of line and also due to sweating. Drain line to be prepared from tray to main drain line/exit. Insulation of heat exchanger to be done to stop sweating of the pipes and heat exchanger. 1 Job
5 Fabrication and Laying of SS pipe line as per Test rig diagram at annex -1a,1b,1c: The work will include the fabrication of SS Pipe line as per diagram including installation of return pressure control valve , flow meters Filter Assemblies , valves , pressure gauges, hoses etc. All the components of supply line like connection with pumps , Hydraulic filter assembly , Hydraulic back pressure relief valves , Back pressure regulators , downstream regulators , pressure gauges , flow meters , valves etc. The line to be insulated with jute rope for insulation against HOT line. The lines to be bend and welded in such a way to avoid any restriction inside the line. All the welding joints to be cleaned and properly finished to avoid any restriction in the flow of the line. All the line must be firmly clamped as per requirement to achieve the minimum possible vibration in the line .Bending of line will be preferable up to the size of 3/4 " . All the bending tools to be arranged by vendor on site for proper bending of the line. 1 Job
6 Connection with services (Refer Item no 57,58 & 59 as per Drawing at Annex-1a,1b,1c) : All the services lines to be connected like chilled water line and compressed air line as per circuit diagram. Chilled water line must be insulated as per standard to avoid heat loss and sweating inside the test rig. Compressed air line to be connected from Air line outlet to all the required points, regulators and valves of the test rig as per drawing. 1 Job
7 Supply of material (Ref Annex-5,5a): SS 316 weld able Fittings, SS 316 Pipe Fittings, Pipe clamps are to be supplied as per annex -5 by Vendor. All other consumables like fasteners, welding electrodes, paint, and insulating material will be in the vendor's scope. 1 Job
8 Electrical lines as per circuit diagram (Refer diagram at Annex-6): All the electrical devices to be mounted properly on Panel. All the sensors to be mounted on respective locations. All electrical Connections from Pump to electrical Drive , Switches , Connections from Sensors to readouts , Connections from DC drives to various instruments like Flow meter readout , DP readout, RPM Readout, Temp Readout , Filters Clogging sensors etc , Connection of Electrical supply from Main drive to panel and distribution of panel supply. All the connection to be done as per Industrial standard following all safety norms and Fire protection. The enclosure of panel containing all the connections to be made fire proof. The line must be routed as per standard practice. All the wires must be routed through Conduit for wire safety and minimum electronic interference. All the wires, Switches, regulating Pots, emergency switches, conduit material and clamping material etc to be supplied by vendor. All tools and tackles to be arranged by vendor. 1 Job
i. The component of the test rig must be installed with proper standard clamps as per pipe sizes and grouting as required to minimize the vibration during testing.
ii. All the joints must be leak proof.
iii. The routing of the line should be as per fluid engineering standards to minimize the frictions losses.
iv. The structure must be rust proof for long life. The MS line, clamps, channels etc must be treated rust proof.
v. SS strays to be fabricated and installed as per drawings to collect all the ATF during opening of the test units , lines etc.
vi. The components of the test rig (as per annex-2) will be provided by HAL.
vii. All the bending, welding and cutting to be done with standard tools to achieve desired finish and result. Bending machine to be arranged by vendor. But welding to be done after maintaining proper V angle for weld on SS pipes through grinding the edge.
viii. All the connection to be done as per Industrial standard following all safety norms and Fire protection. The enclosure of panel containing all the connections to be made fire proof
ix. All drawing details and attached documents to be well understood by vendor.
x. Vendor need to depute sufficient man power to move material from one place to other within HAL as on when needed.
xi. Vendor may also visit HAL ADL site for assessment of the work.
Name of Vendor:
Tender No : HAL-ADL/EQUIP/NSE/JAGUAR/23- 24/CWA-24OT/2 dtd : 26.04.2024
Name of the work : Fabrication Work & Laying of Pipeline of FCU test rig .
Eligibility Criterion & Instructions to Bidders
i) Bidder must strictly comply with these instructions while submitting the offer.
ii) Bidder to categorically confirm that offer submitted is as per instructions given herein.
S.N. Clause Bidder Confirmation (To be filled by Bidder)
1 Bidder required to uploaded Quotation in Two parts (Price & Technical Bid) in the prescribed format
2 No hard copy of the offer is to be sent.
3 Scan copy of DD/ pay order of EMD amount Rs. 1,93,520 /-is to be uploaded on the portal and original to be dispatched by post in order to reach us prior to tender closing date & time as indicated in RFQ, Failure in receipt of original EMD before tender opening will result in rejection of offer. For any postal delay, HAL will not be responsible.
Please mention following information on envelope carrying EMD.
1) Title: EMD against e-tender
2) Tender No…... & Due Date……............
3) Tender Description…….
Please dispatch the Original EMD at following address:
AGM (TS& Maint)
Hindustan Aeronautics Limited
Accessories Division, Lucknow-226016.
Firms exempted from submission of EMD must attach a certified copy of GOT's authority (at e-portal) allowing for such exemption in view of tender fee/EMD. The offers without EMD/ EXEMPTION certificate shall be considered as unresponsive and rejected.
Kindly note that EMD in the form of demand draft/pay order should be in the name of "Hindustan Aeronautics Limited, Accessories Division, Lucknow".
4 Unpriced Bid shall be opened as per schedule indicated on e-portal.
5 EMD shall be refunded to unsuccessful bidders after evoluation of L-1 vendor and award of order. For successful bidder, the EMD will be adjusted towards security deposit.
EMD will be forfeited, if the bidder withdraws/amends or derogates from the tender in any respect within the validity period of his offer submitted.
6 Scan copies of under mentioned documents to be uploaded on E-portal:
a). Proof for PAN No.
b). GST Registration Certificate.
c). Firm PF & ESI certificate (if applicable).
d). Financial standing/Solvency Certificate for minimum value of 40% of the estimated value from any nationalized/scheduled bank issued within the period of 12 months from the final date of submission of tender.
e). Earnest money of Rs. 1,93,520 /- in the form of Demand Draft, in favor of Hindustan Aeronautics Limited, Accessories Division, Lucknow from any nationalized/scheduled bank of India.
f). i) Constitution, legal status and Power of attorney in case of Pvt. Limited/ limited companies
ii) Registration with HAL / other organization if any
g). Average annual financial turnover during last three years, ending 31st March of previous financial year, audited proof to be attached and should be at least 30% of the estimated cost.
h). Proof of experience of having successfully completed similar work during last 7 years ending last day of months previous to the one in which tender are invited should be either of the following.
i) Three similar completed works each costing not less than 40% of estimated value
ii) Two similar completed works each costing not less than the amount 50% of the estimated value.
iii) One similar works completed each costing not less than the amount 80% of the estimated value
7 You should quote price per unit and total price in figures & in words.
8 Disregard of any instructions, may result in your offer being ignored.
Note: Bidders / Tenderers are requested to attach scan copies of all the relevant / desired / required proofs/ documents on e-portal, failing which tender shall be summarily rejected without assigning any reason to bidders.
* Here similar work means work related to "Fabrication & supply of Test Rig "
Name of Vendor:
Tender No : HAL-ADL/EQUIP/NSE/JAGUAR/23- 24/CWA-24OT/2 dtd : 26.04.2024
Name of the work: Fabrication Work & Laying of Pipeline of FCU test rig .
S.N. TERMS AND CONDITIONS Remarks
(To be filled by Bidder)
1 The contractor shall fully acquaint himself with the scope and nature of working conditions, etc before submission of tender/offer. No claim will be considered later on the grounds of ignorance or otherwise of the conditions under which the work will have to be executed.
2 Acceptance of Tender: The Contractor shall be bound to accept the award of contract at the rates quoted/ agreed by him. Failing which the EMD of the contractor shall be forfeited and party shall be debarred/ blacklisted as per HAL-ADL rules.
3 Contract Period: The work to be completed within 4 Months from the acceptance of work order. No extension will be given unless the delay is due to site clearance. All fabrication work to be completed within 3 months after that 3-4 weeks may be taken for testing of the system.
4 Compensation for Delay:
If the work is not completed within stipulated date of completion, the compensation for delay shall be deductible from any sum payable to you under work order or any other contract with HAL. The compensation delay shall be @ 1% of total payable amount per week limited to the maximum 10% of total payable amount
i) The quoted price shall be on lump sum basis. Please note that basis of evaluation of lowest tender will be the package value offered for subject work.
ii) The prices shall be inclusive of GST. Mention the percentage of GST clearly on contract value.
Scan copy of DD/ pay order of EMD amount Rs. 1,93,520 /- is to be uploaded on the portal and original to be dispatched by post in order to reach us prior to tender closing date & time as indicated in RFQ, Failure in receipt of original EMD before tender opening will result in rejection of offer. For any postal delay HAL will not be held responsible.
7 Security Deposit:-
7.1 The successful renderer will be required to furnish security deposit for the fulfillment of contract. The security deposit shall be 10% of the original contract value consisting of two parts: -
i). Performance Guarantee shall be 5% of contract value and will be deposited in the form of Bank Demand Draft in favor of HAL, Accessories Division, Lucknow within 21 days of acceptance of work order or before commencement of work whichever is earlier. The Performance Guarantee money shall be refunded within 30 days after issue of the completion certificate.
ii). Retention money will be deducted @ 5% from all running bills. The total deducted retention money shall be refunded after defect liability period.
iii). Any delay in submission of security deposit shall attract a penal recovery for delay period @2% of security deposit per week or part thereof with a maximum penalty of 25% of security deposit.
7.2 The EMD deposited will be adjusted toward Performance Guarantee and balance amount shall be deposited through demand draft in favor of HAL, Accessories division, Lucknow payable at Lucknow.
8 Payment Terms:- The terms of payment shall be as follows:
i) Payment shall be made after completion of work and on submission of bills & reports and after certified by OIC/EIC that the work has been completed satisfactorily and that no penalty is laviable for any deviation. Payment will be made through e-payment system.
ii) GST and other Taxes shall be applicable as per rules at the time of payment.
9 Defect Liability Period: The defect Liability period of the work will be 12 months from the date of Successful acceptance of the work. During Defect Liability period, contractor shall rectify the issue within reasonable time. In case he fails to do so within a reasonable time, HAL will proceed at his risk & cost and get the work completed. The cost incurred by HAL will be recovered from the defaulting contractor from the Defect Liability Deposit (DLD) or if the money to be recovered is higher than the DLD, then from any amount due to contractor from any other contract in HAL.
10 Risk Clause: The contractor shall be responsible for completion of the contract as required by HAL-ADL as per contract terms & conditions. In case, the contractor fails to execute the contract either in terms of quality or quantity or if any work remains unattended within the stipulated time, HAL-ADL is empowered to take decision and get the same attended by any other Agency at the risk and cost of the Contractor. Any extra expenditure incurred in this connection will be recovered from the bills of the Contractor.
11 Contract Agreement: Successful contractor shall execute an agreement on a general stamp paper of the value of Rs. 100.00 on the enclosed Proforma. All partners of the contractor shall sign the agreement or one partner should have proper authority letter from all other partners. The authority letter has to be forwarded with the agreement. The agreement is to be executed within 30 days from the date of acceptance of work order.
i) Staff: Entry of staff engaged for the work shall be controlled as per HAL security rules & regulations.
ii) Material: All material whether to be consumed in the work or to be taken back later shall be entered through proper challans duly checked & entered by HAL security gate and duly checked and signed by OIC/EIC.
13 Parallel Contract: HAL reserve the rights for entering into parallel contracts with other firms/ Contractors for the same requirement if it is found necessary.
14 Validity of offer: Offer should be valid for a period of at least 120 days from the date of opening of tender.
15 General Conditions:
(a) All the other terms and conditions of HAL work procedure shall be applicable to this work.
(b) Required tools and tackles are to be arranged by tenderer.
(c) Unsolicited letter/canvassing / post tender correction: Canvassing by tenderer in any form including unsolicited render tenders liable for rejection.
(d). The HAL reserves all the right to accept/ reject any or all the tenders without assigning any reason whatsoever.
Note: The Bidders / Tenderers are requested to attach scan copies of all the relevant / desired / required proofs/ documents on e-portal, failing which tender shall be summarily rejected without assigning any reason to bidders.
Name of Vendor:
Tender No : HAL-ADL/EQUIP/NSE/JAGUAR/23- 24/CWA-24OT/2 dtd : 26.04.2024
Name of the work: Fabrication Work & Laying of Pipeline of FCU test rig .
TECHNICAL COMPLIANCE MATRIX
(SCOPE OF WORK)
Sl No Work Description Qty Unit Bidder's compliance
Complied/Not complied
Fabrication and Installation of FCU Test Rig SS pipe lines along with installation of following components of the circuit as per test rig drawing attached at annex -1a, 1b, 1c. The detailed list of components to be installed in the system which are under HAL’s Scope is attached at annex 2.
1 Supply and Installation of main panel and mounting on all equipment on panel of the rig( Refer Drawing at Annex 3): The work will include the fabrication of panel as per drawing at annex 3 and installation of the same to mount all the equipments of the testing rig as per drawing .All the equipments like pressure gauges , Valves , Rotameters,Electronic readouts (for temp ,Differential Pressure ,RPM ,flow etc), DC drive, Hydraluc supply and return outlets for hoses, Various switches , Bulbs , etc to be mounted on the Panel. All the items will be mounted properly and will be screwed on the panel as per mounting instructions .No vibration, looseness, misalignments should be there. The panel will be painted as per given standard and will be leveled as per given instruction. The panel needs to be rust free, spray painted, robust and vibration free & give aesthetic look along to the rig. A proper drain connection as per drawing to be provided on SS tray of the panel to collect the drain from the unit during opening of the connections and drain point to be connected with main drain line. 1 Job
2 Supply and installation of SS Tank with stand (Refer Item No 1 in Test Rig Drawing at Annex-1a & SS tank Drawing at Annex 4): The SS tank to be supplied and installed as per drawing at Annex -4 with all required connections. The tank will be grouted firmly on ground through fastners for no vibration during testing. The proper leveling will be done at each connection. The tank should be buffed from outside to giving shining and aesthetic look. Proper connections for supply line, return line, ATF filling line, Drain Line and Sample check line should be made as per drawing at Annex 4.A breather should be provided at the top side of the tank as per drawing. The top flange should be welded in such a way that there should not be any bulging of tank neck .Also the flange after welding should be perfectly horizontal and sealed after tightening . 1 Job
3 Installation of Power pack (Ref Item No 31 in Test Rig Drawing at Annex-1a) : The work will include positioning of motor pump and drives on location , grouting , and installation of the power pack with connection to SS supply , return and drain lines as per drawing. There the pump to be aligned with plummer block of approximate 1.2 m long with in 50 Micron for running smoothing at higher RPM without vibration. The plummer block, Motor and Pump to be aligned with in 100 micron. Proper shimming of motor and plummer block to be done to maintain required alignment. The plummer block will be provided by vendor to connect pump with motor. All the shim to be provided by vendor. The motor will perform up to 5000 RPM. 1 Job
4 Installation of Heat Exchanger (Ref Item No 12 in Test Rig Drawing at Annex-1a): The work will include positioning and installation of heat exchanger on wall with proper grouting and connection with SS line and chilled water lines. The SS stray to be fabricated and installed beneath the heat exchanger to collect the water from pipe during opening of line and also due to sweating. Drain line to be prepared from tray to main drain line/exit. Insulation of heat exchanger to be done to stop sweating of the pipes and heat exchanger. 1 Job
5 Fabrication and Laying of SS pipe line as per Test rig diagram at annex -1a,1b,1c: The work will include the fabrication of SS Pipe line as per diagram including installation of return pressure control valve , flow meters Filter Assemblies , valves , pressure gauges, hoses etc. All the components of supply line like connection with pumps , Hydraulic filter assembly , Hydraulic back pressure relief valves , Back pressure regulators , downstream regulators , pressure gauges , flow meters , valves etc. The line to be insulated with jute rope for insulation against HOT line. The lines to be bend and welded in such a way to avoid any restriction inside the line. All the welding joints to be cleaned and properly finished to avoid any restriction in the flow of the line. All the line must be firmly clamped as per requirement to achieve the minimum possible vibration in the line .Bending of line will be preferable up to the size of 3/4 " . All the bending tools to be arranged by vendor on site for proper bending of the line. 1 Job
6 Connection with services (Refer Item no 57,58 & 59 as per Drawing at Annex-1a,1b,1c) : All the services lines to be connected like chilled water line and compressed air line as per circuit diagram. Chilled water line must be insulated as per standard to avoid heat loss and sweating inside the test rig. Compressed air line to be connected from Air line outlet to all the required points, regulators and valves of the test rig as per drawing. 1 Job
7 Supply of material (Ref Annex-5,5a): SS 316 weld able Fittings, SS 316 Pipe Fittings, Pipe clamps are to be supplied as per annex -5 by Vendor. All other consumables like fasteners, welding electrodes, paint, and insulating material will be in the vendor's scope. 1 Job
8 Electrical lines as per circuit diagram (Refer diagram at Annex-6): All the electrical devices to be mounted properly on Panel. All the sensors to be mounted on respective locations. All electrical Connections from Pump to electrical Drive , Switches , Connections from Sensors to readouts , Connections from DC drives to various instruments like Flow meter readout , DP readout, RPM Readout, Temp Readout , Filters Clogging sensors etc , Connection of Electrical supply from Main drive to panel and distribution of panel supply. All the connection to be done as per Industrial standard following all safety norms and Fire protection. The enclosure of panel containing all the connections to be made fire proof. The line must be routed as per standard practice. All the wires must be routed through Conduit for wire safety and minimum electronic interference. All the wires, Switches, regulating Pots, emergency switches, conduit material and clamping material etc to be supplied by vendor. All tools and tackles to be arranged by vendor. 1 Job
i. The component of the test rig must be installed with proper standard clamps as per pipe sizes and grouting as required to minimize the vibration during testing.
ii. All the joints must be leak proof.
iii. The routing of the line should be as per fluid engineering standards to minimize the frictions losses.
iv. The structure must be rust proof for long life. The MS line, clamps, channels etc must be treated rust proof.
v. SS strays to be fabricated and installed as per drawings to collect all the ATF during opening of the test units , lines etc.
vi. The components of the test rig (as per annex-2) will be provided by HAL.
vii. All the bending, welding and cutting to be done with standard tools to achieve desired finish and result. Bending machine to be arranged by vendor. But welding to be done after maintaining proper V angle for weld on SS pipes through grinding the edge.
viii. All the connection to be done as per Industrial standard following all safety norms and Fire protection. The enclosure of panel containing all the connections to be made fire proof
ix. All drawing details and attached documents to be well understood by vendor.
x. Vendor need to depute sufficient man power to move material from one place to other within HAL as on when needed.
xi. Vendor may also visit HAL ADL site for assessment of the work.
Name of Vendor:
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
raw.json
RAW_JSON
SCOPE_OF_WORK.pdf
TENDER_DOCUMENT • 1.57 MB
Notice_Inviting_Tender.pdf
TENDER_DOCUMENT • 0.05 MB
Annex_D.xlsm
TENDER_DOCUMENT • 0.01 MB
Annex_A.xlsm
TENDER_DOCUMENT • 0.01 MB
Annex_B.xlsm
TENDER_DOCUMENT • 0.01 MB
Annex_C.xlsm
TENDER_DOCUMENT • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .