| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.7 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹50.0 L+₹3.3 L (7.12%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹54.3 L+₹7.6 L (16.2%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹58.0 L+₹11.3 L (24.2%)Rejected-Finance 223 02 WARD NO 10 A DHURI DISTT SANGRUR | DHURI | SANGRUR | PUNJAB | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | Rejected-Technical | - | Rejected-Technical Not R due to being 02 class below requisite class. |
| Sl No | Description | Qty | Unit | M/S VED PAUL MAHAJAN L1 | M/s Koul & Sons L3 | MALIK CONSTRUCTION L2 | SHARMA CONSTRUCTION COMPANY L4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Removing existing treatment from roof surfaces such as tiling, tarfelt, fungus,moss,dust etc.,cleaning the surface of all foreign material by wire brushing and dusting and racking out RCC slab complete all as specified and as directed and removing the debries outside defence land. | 1,600 | Sqm | 50 ₹80,000 | 70 ₹1,12,000 | 10 ₹16,000 Lowest | 18 ₹28,800 |
| 2.00 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete all as specified and as directed. | 81.5 | Cum | 80 ₹6,520 | 320 ₹26,080 | 200 ₹16,300 | 18 ₹1,467 Lowest |
| 3.00 | Cleaning of the exposed concrete slab and repairing the surface irregularities like cracks, potholes, as per manufacturers method statement by Berger Home Shield crackfill paste/ Asian Smartcare Crack seal fill or equivalent along with Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent & cement in mixing ratio of 1:4 where ever required complete all as specified and as directed. | 1,600 | Sqm | 350 ₹5,60,000 | 380 ₹6,08,000 | 410 ₹6,56,000 | 108 ₹1,72,800 Lowest |
| 4.00 | Providing cement concrete 1:2:4 type B-0, (using 12.5 mm graded crushed stone aggregate ) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed. | 64 | Cum | 3,050 ₹1,95,200 Lowest | 5,500 ₹3,52,000 | 3,300 ₹2,11,200 | 3,600 ₹2,30,400 |
| 5.00 | Berger Home Shield PU Roofkoat/ Asian Smartcare PU Aqua or equivalent is a one component liquid ,solvent free ,cold applied , water-proofing membrane that is highly elastic and UV resistant with 10 years Warranty. ASTM D 6083-97a Waterproofing and heat reflecting system having following key performance properties. (i) UV resistant, prevent yellowing and weathering. (ii) Highly elastic upto 350% and crack bridging. (iii) Excellent adhesion on porous and non-porous substrates. (iv) Tensile Strength >10 N/Sqmm with GeoTextile fleece.
(v) Solar Reflective Index (SRI) more then 109-111 ASTM E1980-11.
System : First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer(or equivalent), Coverage : 0.2Kg/Sqm (with 50% dilution of water), Reinforcement: Geotextile 40 gsm, Second coat: Berger Home Shield PU Roofkoat/ Asian Smartcare PU Aqua or equivalent, Consumption: 0.5 Kg/Sqm, Third coat: Berger Home Shield PU Roofkoat/ Asian Smartcare PU Aqua or equivalent, Consumption : 0.8 Kg/Sqm. System buildup -1.5Kg/Sqm with geotextile of 40 gsm | 1,600 | Sqm | 500 ₹8,00,000 Lowest | 780 ₹12,48,000 | 800 ₹12,80,000 | 720 ₹11,52,000 |
| 6.00 | Plain cement concrete type D-2,1:4:8 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete, RCC sunken portion as base layer for receiving top layer complete all as specified and as directed. | 5 | Cum | 1,560 ₹7,800 Lowest | 2,800 ₹14,000 | 2,800 ₹14,000 | 2,700 ₹13,500 |
| 7.00 | Glass fibre reinforced modified cementitious coating system before the final coat of Berger Home Shield Latex Shield 2K / Asian smartcare Professional Damp Block 2K or equivalent in Sunken treatemen.
Base coat : Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent,
Consumption base coat : 0.3 Kg/Sqm, Reinforcement : Glass fiber, Second and Third coat :Berger Home Shield Latex Shield 2K / Asian smartcare Professional Damp Block 2K or equivalent, Consumption top coat: 3 Kg/Sqm, System requirements : density: 2.00 Kg/Ltr, Compressive strength : 0.5 N/Sqmm.
(i) Wall penetration through the RCC slab must be sealed using Berger Home Shield crackfill paste/ Asian Smartcare Crack seal fill or equivalent.
(ii) Intersection of base slab with wall must be provided with a 50 mm fillet using Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent modified mortar with a bonding coat of Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent) modified cement slurry upto 1.5 Mtr.
(iii) All depressions, unevenness, surface honeycombing shall be repaired using Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalentx) modified polymer mortar with a bonding coat of Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent modified cement slurry, including cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc | 100 | Sqm | 480 ₹48,000 | 400 ₹40,000 Lowest | 650 ₹65,000 | 600 ₹60,000 |
| 8.00 | Complete removal of vegetations, roots and shurbs from wall, ceiling, roof and adjecent to pipes etc and making good with PCC 1:2:4 or brick work and finishing the surface to match the existing surface including necessary scaffolding up to three storey building complete all as specified and as directed. | 120 | Each Job | 50 ₹6,000 | 10 ₹1,200 | 50 ₹6,000 | 9 ₹1,080 Lowest |
| 9.00 | Dismantling floors hearth or wall tilling including cement mortor bedding (but not backing) removing unserviceable materials outside MOD area and rubbish off the premises complete all as specified and as directed. | 480 | Sqm | 30 ₹14,400 | 10 ₹4,800 | 5 ₹2,400 Lowest | 18 ₹8,640 |
| 10.00 | Non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile not exceeding 0.18 Sqm, in floors etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed. | 200 | Sqm | 680 ₹1,36,000 Lowest | 840 ₹1,68,000 | 800 ₹1,60,000 | 900 ₹1,80,000 |
Tender Value
₹75 L
EMD Value
₹1.4 L
Closing Date
11 Aug 2025, 6:00 pmClosed
Col Amt Bhardwaj
MES, HQ CWE Jammu PIN-900172
MISC B/R WORK TO ADDRESS LEAKAGE SEEPAGE TO SHAFT, CHAJJA, SUNKEN, ROOF TREATMENT, ROOF SHEET , FALSE CEILING AND OTHER CONNECTED ITEMS AT DAMANA MIL STATION UNDER GE JAMMU
2025_MES_719038_1
CWE/JP-25/2025-26
Open Tender
Civil Works - Others
Item Rate
180 days
GE Jammu
As per tender documents
9 documents required · 9 mandatory
₹1,000
GE Jammu
₹1.4 L
Yes
18 Sept 2025
7 Jul 2025
13 Aug 2025
7 Jul 2025
11 Aug 2025
28 Jul 2025
7 Jul 2025 - 9 Jul 2025
Amount
Removing existing treatment from roof surfaces such as tiling, tarfelt, fungus,moss,dust etc.,cleaning the surface of all foreign material by wire brushing and dusting and racking out RCC slab complete all as specified and as directed and removing the debries outside defence land.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for and complete all as specified and as directed.
Cleaning of the exposed concrete slab and repairing the surface irregularities like cracks, potholes, as per manufacturers method statement by Berger Home Shield crackfill paste/ Asian Smartcare Crack seal fill or equivalent along with Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent & cement in mixing ratio of 1:4 where ever required complete all as specified and as directed.
Providing cement concrete 1:2:4 type B-0, (using 12.5 mm graded crushed stone aggregate ) in roof padding, roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed.
Berger Home Shield PU Roofkoat/ Asian Smartcare PU Aqua or equivalent is a one component liquid ,solvent free ,cold applied , water-proofing membrane that is highly elastic and UV resistant with 10 years Warranty. ASTM D 6083-97a Waterproofing and heat reflecting system having following key performance properties. (i) UV resistant, prevent yellowing and weathering. (ii) Highly elastic upto 350% and crack bridging. (iii) Excellent adhesion on porous and non-porous substrates. (iv) Tensile Strength >10 N/Sqmm with GeoTextile fleece. (v) Solar Reflective Index (SRI) more then 109-111 ASTM E1980-11. System : First coat : Providing and applying primer over the prepared surface with HS PU roofkoat Primer(or equivalent), Coverage : 0.2Kg/Sqm (with 50% dilution of water), Reinforcement: Geotextile 40 gsm, Second coat: Berger Home Shield PU Roofkoat/ Asian Smartcare PU Aqua or equivalent, Consumption: 0.5 Kg/Sqm, Third coat: Berger Home Shield PU Roofkoat/ Asian Smartcare PU Aqua or equivalent, Consumption : 0.8 Kg/Sqm. System buildup -1.5Kg/Sqm with geotextile of 40 gsm
Plain cement concrete type D-2,1:4:8 (using 40 mm graded crushed stone aggregate) as in foundation, filling and mass concrete, RCC sunken portion as base layer for receiving top layer complete all as specified and as directed.
Glass fibre reinforced modified cementitious coating system before the final coat of Berger Home Shield Latex Shield 2K / Asian smartcare Professional Damp Block 2K or equivalent in Sunken treatemen. Base coat : Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent, Consumption base coat : 0.3 Kg/Sqm, Reinforcement : Glass fiber, Second and Third coat :Berger Home Shield Latex Shield 2K / Asian smartcare Professional Damp Block 2K or equivalent, Consumption top coat: 3 Kg/Sqm, System requirements : density: 2.00 Kg/Ltr, Compressive strength : 0.5 N/Sqmm. (i) Wall penetration through the RCC slab must be sealed using Berger Home Shield crackfill paste/ Asian Smartcare Crack seal fill or equivalent. (ii) Intersection of base slab with wall must be provided with a 50 mm fillet using Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent modified mortar with a bonding coat of Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent) modified cement slurry upto 1.5 Mtr. (iii) All depressions, unevenness, surface honeycombing shall be repaired using Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalentx) modified polymer mortar with a bonding coat of Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent modified cement slurry, including cleaning of RCC surface to remove dust, loose particles, etc with compressed air or any other suitable technique depending on site conditions, grinding any sharp edges, etc
Complete removal of vegetations, roots and shurbs from wall, ceiling, roof and adjecent to pipes etc and making good with PCC 1:2:4 or brick work and finishing the surface to match the existing surface including necessary scaffolding up to three storey building complete all as specified and as directed.
Dismantling floors hearth or wall tilling including cement mortor bedding (but not backing) removing unserviceable materials outside MOD area and rubbish off the premises complete all as specified and as directed.
Non-skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile not exceeding 0.18 Sqm, in floors etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed.
Glazed ceramic tiles 300x450x7mm thick on vertical surface such as in skirting, dado etc. fixed with approved tile adhesive and provided with 4mm spacer, spacer gaps to be filled with approved epoxy grout complete all as specified and as directed.
PCC 25mm thick type B-0, 1:2:4 (12.50mm graded crushed stone aggregate) in sub base for floor tiles complete all as specified and as directed.
PCC 75mm thick type C-2, 1:3:6 (40mm graded crushed stone aggregate) in plinth protection/path/Hardstanding finished even and fair complete all as specified and as directed.
Demolition of stone slabs and tiles of any description or thickness in floors/ walls laid bedded and pointed in any mortar etc complete all as specified and as directed.
Granite (of any type) 16-20mm thick (tabled rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in colour cement 1:2 using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick screedbed in cm1:6 edges of slab to be rounded from all sides (including cutting, wastage and polishing) complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars,etc complete all as specified and as directed.
Brick work with sub class ‘B’ bricks straight or curved on plan exceeding 6 mtr mean radius built in Cement Mortar (1:6) complete all as specified and as directed.
Taking down Cement Plaster of any description on Brick Walls, Concrete Surfaces including Racking out Joints, hacking for Key, scrubbing down with Water, etc. complete removal of debris outside MD land. (Including all necessary scaffolding lifiting arrangement up to 12 mtr height). complete all as specified and as directed.
Rendering 5mm thick on fair faces of concrete surface of ceiling in Cement Mortar 1:3, surface finished even and smooth surface without using extra cement complete all as specified and as directed.
Rendering 10mm thick on fair faces of brick work or concrete surface in Cement Mortar 1:6 surface finished even and smooth without using extra cement complete all as specified and as directed.
Rendering 15mm thick in Cement Mortar 1:4 in on fair faces of brick surface finished even and fair including water proofing compound all as specified. (Including all necessary scaffolding lifiting arrangement up to 12 mtr height) complete all as specified and as directed.
Capillary rise treatment of walls, Consumption base coat: 0.3 Kg/Sqm, Second and Third coat : Berger Home Shield Advanced Latex Plus/ Asian smartcare Repair Polymer (SBR Latex) or equivalent, Consumption top coat: 3 Kg/Sqm, System requirements : density : 2.00 Kg/Ltr, Compressive strength: 0.5 N/Sqmm. complete all as specified and as directed.
Preparing of New plastered surface of ceiling and applying two coats of distemper oil bound over primer coat, complete all as specified and as directed.
Preparing of New plastered surface of wall and applying wall care putty and applying two coats of distemper oil bound over primer coat, complete all as specified and as directed.
Preparing of New plastered surface of wall surface and applying exterior wall care putty and acrylic smooth exterior paint of required shade (Two coat over and including priming coat of exterior primer applied as per manufacturer instructions) (Including all necessary scaffolding lifiting arrangement up to 12 mtr height). complete all as specified and as directed.
Complete removal of existing treatment and preparation of ceiling and applying two coats of distemper oil bound over primer coat, complete all as specified and as directed.
Complete removal of existing treatment and preparation of surface and applying wall care putty on old surface of walls and applying two coats of distemper oil bound over primer coat, complete all as specified and as directed.
Complete removal of existing treatment on wall / ceiling surface and applying exterior wall care putty and acrylic smooth exterior paint of required shade (Two coat over and including priming coat of exterior primer applied as per manufacturer instructions) including exterior wall care putty (Including all necessary scaffolding lifiting arrangement up to 12 mtr height) complete all as specified and as directed.
Dismantling of Asbestos cement (corrugated or semicorrugated etc) sheets in roof covering complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (AZ 150) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick (AZ 150) of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Dismantling and refixing of corrugated/plain steel sheet of any type and any thickness as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Closing bolt holes etc. in old corrugated steel sheets or Aluminium sheeting by sealing with one bitumen and one curved GI washer on either side and 6mm G.I. bolts and nuts, all set in stiff white lead, bolt not exceding 25mm in length complete all as specified and as directed.
Dismantling of timber scantling 40 sq cm and over in section framed work of any description complete all as specified and as directed.
Structural steel works of Fe 410W (Gde E 250) quality B, as in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and as directed.
Preparation of New Steel surfaces of any description, over 10cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of primer complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed.
4mm thick of size 605 X 605 mm, white pre-premiered, self embossed, reinforced designer board for false ceiling conforming to IS-14862 and ISO-8336:1993 and GI section frame work (POWDER COATED) for white, pre-premiered, self embossed, reinforced designer board consisting of perimeter wall angle 19mm X 19mm X 0.45mm, cross 'Tee' 28.6mm (web) X 24mm flange. 33mm thick powdered coated main tee 38 (Web) X 24mm flange 0.33mm thick. Wall angle screwed fixed to brick wall / partition wall / concrete / RCC with the help of nylon sleeves and screws @ 610 mm centre to centre, then suspending GI main 'Tee' in both directions by means of hangers with alignment @ 1220mm centre to centre to soffits. To from grid of 610 X 610mm cross Tee shall be provided @ 610mm centre to centre in both directions. Suitable provisions shall be made for fixing the recessed / surface mounting light fittings if any, complete all as specified and as directed.
20mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) inlcuding taking down 15mm steel tubing complete all as specified and as directed.
25mm outer dia CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) inlcuding taking down 20mm steel tubing complete all as specified and as directed.
Taking up or down and refixing 20mm bore steel tubing and connections in new or old position (Walls, ceiling, floors, etc) complete all as specified and as directed.
Stainless steel sink with drainage board made out of 1.00mm thick sheet for kitchen with plug, washers, waste pipe, connecting union overall size 915mm x 460mm with bowl size 410mm x 330mm x 160mm including 40mm bore PTMT Waste coupling, fixing in cement mortar on to dwarf wall or fixing cantilever brackets complete all as specified and as directed.
Vitreous china wash down water closet pan with flushing cistern (one piece) including fixing bolts, softcloser seat cover and flush pipe with 'P' trap connecting pipe complete all as specified and as directed.
Vitreous china wash down water closet (Padestal Pattern) P or S trap (excluding flushing cistern and flush pipe) including PVC seat cover white closed pattern with recessed bottom and connection to drain or out going pipe and flushing pipe complete all as specified and as directed.
Vitreous china squatting Pan 'Orrisa' Pattern size 580 x 440 mm white with integral foot rest , P or S Trap, and lime concrete bedding complete making good disturb ground complete all as specified and as directed.
10 ltr capacity PVC Low level flushing cistern including 32mm dia PVC flush pipe, fixing in position with PVC connection pipe of 15mm x 450mm long etc complete all as specified and as directed.
Vitreous China bowl urinal flat back, with grating and union for discharge pipe including including 32mm bore PTMT Waste coupling, PVC connection pipe of 15mm x 450mm long and 32mm PVC Waste pipe complete all as specified and as directed.
Vitreous China Wash hand basin, counter top, any coloured including 32mm bore PTMT Waste coupling, PVC connection pipe of 15mm x 450mm long and 32mm PVC Wast pipe complete all as specified and as directed.
Vitreous China Wall hang wash hand basins including 32mm bore PTMT Waste coupling , waste pipe and PVC connection pipe of 15mm x 450mm long, complete all as specified and as directed.
15mm bore chromium plated wall mixer with bend pipe for overhead shower pipe for mixing hot & cold water with connecting legs and wall flanges screwed down for iron pipe and fixed complete all as specified and as directed.
15mm bore chromium plated Basin / Sink mixer for mixing hot & Cold water screwed down for iron pipe complete all as specified and as directed.
15mm bore chromium plated cast copper alloy bib taps fancy type with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule complete all as specified and as directed.
15mm bore Bib tap (2 in 1 type) of brass , glossy finish complete all as specified and as directed.
15mm bore pillar taps, cast copper alloy fancy type with capstan heads, chromium plated screw down high pressure, screwed for iron pipe complete all as specified and as directed.
15mm bore chromium plated Pillar tap Swan neck with Swinging Spout of brass, glossy finish complete all as specified and as directed.
15mm bore Angle/Stop cock of chromium plated, glossy finish complete all as specified and as directed.
15mm bore stop valves, fancy type, chromium plated with long shank and cup (concealed type), screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified and as directed.
Brass chromium plated shower rose 125mm size with or without swivel joints any size including fixing to steel pipe of 15mm bore complete all as specified and as directed.
Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm bore pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and as directed.
Disconnecting existing tanks 500 or 1000 ltr of capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position. (Cleaning, repairing, etc. measured separately) complete all as specified and as directed.
Rotational moulded polyethene water storage tanks 1000 lit capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I including dismantling of existing water tank,including 20mm Ball Valves, 20mm Tank nipple, complete all as specified and as directed.
Rotational moulded polyethene water storage tanks 500 lit capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part-I including dismantling of existing water tank,including 20mm Ball Valves, 20mm Tank nipple, complete all as specified and as directed.
25mm outer dia CPVC gate valves complete all as specified and as directed.
20mm dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) complete all as specified and as directed.
110mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls / floor etc complete all as specified and as directed.
75mm dia PVC (SWR) pipes single socketed in any length with rubber joints fixed to walls / floor etc complete all as specified and as directed.
PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement etc complete all as specified and as directed.
PVC (SWR) Bends / Tee / Y 110mm dia any radius with access door complete all as specified and as directed.
PVC (SWR) Bends / Tee / Y 75 mm dia any radius with access door complete all as specified and as directed.
PVC (SWR) vent cowl 110mm bore complete all as specified and as directed.
PVC (SWR) vent cowl 75mm bore complete all as specified and as directed.
Taking down chowkats or frames with shutters (w/o taking off shutters from the frames) not exceeding 1.5 sqm each, including cutting holes for taking out holdfasts or dismantling brick work(holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish (without any extra cost to Govt), & removing from site complete all as specified and as directed.
Taking down chowkats or frames with shutters (w/o taking off shutters from the frames) exc 1.5 sqm and not exc 4 sqm each, including cutting holes for taking out holdfasts or dismantling brick work(holes cut and any other damage to jambs, walls for taking out holdfasts shall be finished identical to existing finish (without any extra cost to Govt), & removing from site complete all as specified and as directed.
Factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat of size 45 x 70 mm ( +5 mm) comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/lugs/SS dash fasteners of required dia and length complete all as specified and as directed.
28 to 30mm thick (stile) Factory made solid PVC moulded door shutter with wood free EPS, with 2,4, or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face, supply and fixing in frame at site complete all as specified and as directed.
Butt Hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised 100 mm long complete all as specified and as directed.
Aluminum anodised bow handle fabricated type extruded section of 150mm long complete all as specified and as directed.
Aluminum anodised barrel tower bolts of extruded section 150mm long complete all as specified and as directed.
MALIK CONSTRUCTION (BID ID -3390237)
M/s Koul & Sons (BID ID -3381827)
SHARMA CONSTRUCTION COMPANY (BID ID -3381054)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .