Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹3.3 L
EMD Value
₹6,622
Closing Date
25 Nov 2022, 10:00 amClosed
EE WSD APWD
EE WSD APWD Port Blair
Comprehensive Annual Maintenance Contract for all capacity and different makes of Air Conditioners Installed in the various buildings and wharves of Port Management Board at Port Blair
2022_APWD_8167_1
196/NIT/WSD/2022-23
Open Tender
Air-Conditioner
Works
365 days
Port Blair
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹6,622
1 Dec 2022
19 Nov 2022
25 Nov 2022
19 Nov 2022
25 Nov 2022
21 Nov 2022
19 Nov 2022 - 25 Nov 2022
Amount
Attending the following routine preventive maintenance of all capacity & different makes of Air Conditioners on as and when required basis and as per the direction of Engineer In - Charge. (This includes cost of labour with tools). (Details of Air - Conditioners as per Annexure -I) *Inspection of the indoor unit and outdoor unit for any abnormality in operation, sound and current consumption, testing the performance of AC for desired cooling. etc. * Testing of gas pressure if necessary and check for any leakages near the check nut / safety valve etc or diagnose any other fault and rectify. * Remove the filters and carry out water service and fix it back after drying. Chemical wash, removel of dust from evaporator and condensor fins etc. * Clean the drain tray and drain pipe and remove any choke for free flow of drain water and Lubricating /greasing of all fans, including check the swing motor functions and rectify, if required.
(Details of Air - Conditioners as per Annexure - I) Vaccumizing, Presssure testing, recharge of full quantity of gas required with R-22/R-32/R-410A or any other gas etc., as required on as and when required basis and as per the direction of Engineer In - Charge. (This includes cost of labour and materials with tools).
(a). 1.5 Ton Capacity
(b). 2.0 Ton Capacity
(Details of Air - Conditioners as per Annexure - I) Replacement of defective compressor unit with new one suitable for following capacity for room ACs i/c pressure testing for leakage, flushing vaccumising the system. Gas charging with R-22/R-32/R-410Aor any other gas, servicing the unit, painting and testing for satisfactory performance etc., as required on as and when required basis and as per the direction of Engineer In - Charge. (This includes cost of labour and materials with tools).
(a). 1.5 Ton Capacity
(b). 2.0 Ton Capacity
(Details of Air - Conditioners as per Annexure - I) Replacement of damaged condensor coil with new copper condensor coil suitable for following capacity ACs i/c dismantling the damaged coil, fixing the new one, gas charging, re-installation and plating patch repair work if any, testing and commissioning the unit etc., as required as required on as and when required basis and as per the direction of Engineer In - Charge. (This includes cost of labour and materials with tools).
(a). 1.5 Ton Capacity
(b). 2.0 Ton Capacity
(Details of Air - Conditioners as per Annexure - I) Provide and replace the following defective / fully faulty spares of all capacity & different makes of Air Conditioners on as and when required basis and as per the direction of Engineer In - Charge. (This includes cost of labour and materials with tools).
(a). Refrigerant copper pipes of suitable sizes (Suction & delivery) i/c providing electrical cables, insulation, topping up of gas charging and covering with PVC non adhessive tape over the insulation of refrigerant pipes.
(b). Fan Motor 1.5 ton (Outdoor unit)
(c). Fan Motor 2.0 ton (Outdoor unit)
(d). Blower Motor 1.5 (Indoor unit)
(e). Blower Motor 2.0 (Indoor unit)
(f). Single pole Magnetic contactor relay (Single core Contactor)
(g).Voltage Stabilizer (4 KVA,150V-285V,12 Amps, 50 Hz)
(h).Voltage Stabilizer (5 KVA,150V-285V, 15 Amps, 50 Hz)
(i). 2.5 MFD black square type capacitor
(j). 3.15 MFD black square type capacitor
(k). 4.0 MFD black square/ round type capacitor
(l). 6.0 MFD black square/ round type capacitor
(m) PCB Assy. Split AC Common-Artic/Universal
Re-installation of Split Type AC Re-installation, testing and commissioning of following capacity split type Air Conditioner suitable for wall mounting complete i/c cutting/ drilling holes on the wall for passing gas pipes , fixing PVC pipe on the wall through the holes and cementing, painting to give an even look and smooth finish, wrapping PVC non adhesive tape over insulation of gas pipe etc including gas charging as required and as per the direction of E-in-C.
1.5 Ton/2Ton
6.0 MFD black square/ round type capacitor
45 MFD Pin type (ALU Body)
60MFD Pin type(ALU Body)
PCB Assy. Split AC Common-Artic/Universal
Insulation Tape (roll)
Freon (R-22) Gas
Refrigerent (R-32) Gas
Refrigerent (R-410A) Gas
Welding can(flame gas)
Welding rod
R K Traders
ROYAL ENGINEERING WORKS
Hi Tech Engineering and consultancy services
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .