Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.3 LAccepted-AOC 37 TILAK NAGAR MATHURA 281001 | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC THE LOWEST TENDERER | |
| 2 | L2₹35.7 L+₹1.4 L (4.13%)Rejected-Finance 37 PUNJABI COLONY NEAR RAILWAY CROOSING ARYA SAMAJ ROAD MATHURA U P | MATHURA | MATHURA | UTTAR PRADESH | 281001 | L2 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 3 | L3₹37.4 L+₹3.0 L (8.84%)Rejected-Finance C 56 6 ANAND VIHAR COMMERCIAL COMPLEX MAHOLI ROAD MATHURA UP PIN 281004 | MATHURA | UTTAR PRADESH | 281004 | L3 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 4 | L4₹39.0 L+₹4.6 L (13.5%)Rejected-Finance LODHI NAGAR NEAR TEACHERS COLONY GALI NO 4 MAHOLI ROAD MATHURA U P 281004 | MATHURA | MATHURA | UTTAR PRADESH | 281004 | L4 | Rejected-Finance NOT THE LOWEST TENDERER | |
| 5 | L5₹39.8 L+₹5.5 L (15.9%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L5 | Rejected-Finance NOT THE LOWEST TENDERER |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
9 May 2022, 6:00 pmClosed
GE EAST MATHURA
Garrison Engineer East Military Engineer Services Mathura Cantt Mathura 281001
REPAIR MAINT AND IMPROVEMENT OF LT NETWORK INCLUDING LT PANELS FEEDER PILLAR BOXES LT OH LINES UG ELECTRIC CABLES STREET LIGHTS SECURITY LIGHTS AND ALLIED WORKS UNDER GE (E) MATHURA
2022_MES_518026_1
8200-1266/E8
Open Tender
Civil Works
Item Rate
180 days
GE EAST MATHURA
AS PER TENDER DOCUEMTNS
8 documents required · 8 mandatory
₹500
GE EAST MATHURA
₹1 L
30 May 2022
13 Apr 2022
11 May 2022
13 Apr 2022
9 May 2022
27 Apr 2022
13 Apr 2022 - 2 May 2022
Amount
Taking down unserviceable LED street / security /flood light fittings of any type / wattage / make etc fitted on LT poles, High Mast light poles, building etc for repairing including complete dismantling, checking for repair / replacement of unserviceable parts as required and making the LED light fittings operational to give rated illumination by replacing unserviceable spare parts and refixing the same at existing location or any other location as directed at site and making electrical connections with existing wire complete all as directed. Notes - (i). Cost of taking down carefully from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard (If required for repair), is deemed to be included under unit rate quoted. (ii) Cost of supply and fixing of major items required to make the lights serviceable shall be measured and paid separately under item No 2.01 to 2.03 of this schedule. (iii). Cost of items or works not mentioned under item 2.01 to 2.03 and however required to make the lights serviceable will be provided by the contractor without any extra cost to the department and cost thereof shall deemed to be included in the unit rate quoted. (iv) Contractor shall be responsible for done day to day repair / Maint works as per schedule and directed by Engr-in-Charge alongwith all necessary required Tool & Plant & vehicle (for timely repair) so that make a functional all security / street lights in the station without any any extra cost.
Supply only following items to be incorporated against item No 1.00 here in before:
Electronic LED driver suitable for LED street light fitting capacity 30/45 Watt make and specification as installed at site.
Electronic LED driver suitable for LED street light fitting capacity 60/70 Watt make and specification as installed at site.
Electronic LED driver suitable for LED street light fitting capacity 90/120 Watt make and specification as installed at site.
Electronic LED driver suitable for LED street light fitting capacity 150/200 Watt make and specification as installed at site..
Supply and fixing in replacemnt sheet moulding compound junction box shock and rust proof, termite resistant, tamper proof single phase, two wire rating of size 250 mm x 200 mm x 105 mm complete with one no. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole /wall complete. Make - Sintex Cat part No GSJB 2520 or equivalent in Hensel/ABB/PSC.
S&F in repair of street light bracket made of GI pipe medium grade bend in shape of 40 mm dia, 1.2 m long and clamped with 2 pairs of 30 x 5 mm flat iron clamps, nuts/bolts/washers & painted with 2 coats of aluminium paint over coat of a red oxide primer on clamps complete.
Supply and fixing in replacement MS clamps including nuts, bolts and washers made out of MS flat strip 30x5 mm thick including cutting, bending, drilling holes in shape and size as per the pole size and fixing with PCC/steel tubular pole for holding of GI pipe brackets for mounting of street lights all as directed at site.
M&L for dismantaling of old/unserviceable PCC poles/struts any type and size.
Supply and erecting in true vertical position steel tubular swaged pole 9mtr long type 410 SP-31 complete with base plate and closed at top, painted with two coats of aluminium paint over a coat of redoxide primer and applying two coats of black bitumnous paint up to the embeeded depth all as specified and as directed by Engr-in-Charge. Note : Earth work and PCC shall be measured and paid separately under relevant item of this BOQ.
Supply and fixing in replacement LED security light 45 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 4500 lumens and high power LED's with secondary optics with 10 KV SPD including fixing on pole or any other location with the help of existing GI bracket including taking down existing unserviceable one complete all as directed at site.
Supply and fixing in replacement LED security light 70 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 7000 lumens and high power LED's with secondary optics with 10 KV SPD including fixing on pole or any other location with the help of existing GI bracket including taking down existing unserviceable one complete all as directed at site.
Supply and fixing in replacement LED security light 90 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 9000 lumens and high power LED's with secondary optics with 10 KV SPD including fixing on pole or any other location with the help of existing GI bracket including taking down existing unserviceable one complete all as directed at site.
Supply and fixing in replacement LED Security light 150 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 9000 lumens including fixing on pole or any other location with the help of existing high mast light structure including taking down existing unserviceable one complete all as directed at site. Make :
Supply and fixing in replacement LED flood light 120 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 12000 lumens including fixing on pole or any other location with the help of existing high mast light structure including taking down existing unserviceable one complete all as directed at site.
Supply and fixing in replacement LED flood light 150 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 15000 lumens including fixing on pole or any other location with the help of existing high mast light structure including taking down existing unserviceable one complete all as directed at site.
Supply and fixing in replacement LED flood light 200 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 20000 lumens including fixing on pole or any other location with the help of existing high mast light structure including taking down existing unserviceable one complete all as directed at site.
Supply and fixing in replacement LED bollard with opal diffuser and aluminum reflector capacity 09 watt including fixing/ grouting on PCC platform of suitable size and taking down existing unserviceable one complete all as directed at site.
Supply and fixing in replacement LED bollard with opal diffuser and aluminum reflector capacity 12 watt including fixing/ grouting on PCC platform of suitable size and taking down existing unserviceable one complete all as directed at site.
Supply and fixing in replacement decorative LED Post top lantern luminaires with diffuser and painted spun aluminum deflector of capacity 20 watt including fixing arrangement including taking down existing unserviceable one complete all as directed at site.
M&L for rewinding of electric motor of capacity upto 2.5 HP after dismantling all electrical and mechanical connection from High mast light with existing super enamel copper wire of existing gauge including insulation and varnishing ,testing and commissioning at site complete all as specified and directed by Enginner-in-Charge.
M&L for replacement of high mast steel wire rope of existing size as per ground complete all as specified and directed by engineer-in-charge.
Supply, laying, jointing and testing of XLPE insulated, sheathed, armoured, heavy duty LT 1100 volts grade cable with aluminium conductor laid in trenches / pipes, fixed to poles / walls, fixing with suitable saddle/clamps complete all as directed including taking out the old burnt out cables all as directed of following sizes :-
10 Sqmm 2 core.
16 Sqmm 4 core.
25 Sqmm 3.5 core.
35 Sqmm 3.5 core.
50 Sqmm 3.5 core.
70 Sqmm 3.5 core.
95 Sqmm 3.5 core.
120 Sqmm 3.5 core.
185 Sqmm 3.5 core.
Excavating in trenches n. exc 1.5m wide and n.exc 1.5m depth for laying of cables, erection of poles,struts, stays etc and getting out in any type of soil all as specified and as directed by Engr-In-Charge.
Returning, filling in including spreading, levelling,watering and well ramming excavated any type soil in layers not exceeding 25 cm thick each , filling back in trenches after cables have been laid and tested, poles,stays,struts have been erected and tested complete all as specified.
Removal of excavated surplus soil any type to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. Note:- Measurement shall be taken after gentling running.
M&L for laying in trenches un-reinforced precast cement concrete cable cover, class LV type 1, flat, size 250mmx150mmx40mm for cable protection laid adjacent to each other length wise perpendicular to the central axis of cable complete all as specified.
M&L for PCC M-7.5 grade (Nominal mix) using 40 mm graded aggregate as in foundation filling and mass concrete.
M&L for Plain cement concrete M-15 grade (Nominal mix) using 20 mm graded stone aggregate) for foundation, coping for pole etc including necessary formwork and finished surfaces complete all as directed
S&F in replacement 1100 volts grade heavy duty flat service electric cable with stranded aluminium conductor of size 4 Sqmm twin core , weather proof , PVC insulated with inner sheathing of PVC tape and overall PVC sheathed for providing electrical connections to existing security / street lights complete all as directed.
S&F in replacement 1100 volts grade heavy duty flat service electric cable with stranded aluminium conductor of size 6 Sqmm twin core , weather proof , PVC insulated with inner sheathing of PVC tape and overall PVC sheathed for providing electrical connections to existing security / street lights complete all as directed.
S&F in replacement 1100 volts grade heavy duty flat service electric cable with stranded aluminium conductor of size 10 Sqmm twin core , weather proof , PVC insulated with inner sheathing of PVC tape and overall PVC sheathed for providing electrical connections to existing security / street lights complete all as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60cmX60cmX6.0mm thick, buried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of the plate not than 1.5mtr below normal ground level connected to GI earth strip of size 32x6mm dia by means of bolts, nuts, check nuts and washers of galvanised iron complete earth pit of PCC M-10(Nominal mix) using 20mm graded stone aggregate, 50mm thick earth pit cover of RCC M-15 (Nominal mix) using 20mm graded stone aggregate with TMT reinforcement bar of 8mm dia @ 150mm centre to centre both ways, MS handle 10mm dia made to shape, PGI funnel, wire mesh and 20mm bore GI water pipe medium grade and 40mm bore medium grade GI pipe for protection of earth strip from plate to main switch board, common salt, charcoal dust including testing on completion complete all as specified and as directed all as shown in electrical plate No. 3 including testing on completion and making good the disturbed surfaces of wall floors etc without claiming extra cost complete. Note: GI strip beyond 5m length from earth electrode shall be measured and paid separately).
M&L for earthing complete with galvanized steel earth plate electrode size 600 mm x 600 mm x 6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron wire 4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 including necessary excavation and earth work all as shown in electrical plate No 3 connected to earthing test point and testing on completion complete all as specified & directed. Note : GI wire and protection pipe upto 7.5 Mtr length from earth electrode shall be included in quoted rate of item.
S&F MCB Single pole and neutral 240 volts, C series of capacity 6 to 32 Amps of breaking capacity 10 KA including connections with copper lugs of suitable size in MCB DBs all as directed.
Supplying and fixing in renewal MCB single pole 230 volts 50 Hz AC of rating 40 to 63 Amp including connection complete all as directed.
Supply and fixing in replacement of MCCB 400Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36 KA.
Supply and fixing in replacement of MCCB 250Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 36KA.
Supply and fixing in replacement of MCCB 100Amp rating,4-pole 415V, adjustable thermal adjustable megnetic type adjustable thermal adjustable megnetic type breaking capacity 16KA.
Supply and fixing in replacement of MCCB 63Amp rating, 4-pole 415V, adjustable thermal adjustable megnetic type breaking capacity 16KA.
M&L for laying GI tubing, light grade, 40 mm bore dia as cable protection fixed on walls/ceiling/laid in floor complete including dismantling corroded GI pipe all as specified and as directed.
M&L for laying GI tubing, light grade, 50 mm bore dia as cable protection fixed on walls/poles/laid in trenches complete including dismantling corroded GI pipe all as specified and as directed.
Taking down unserviceable solar street lgit fittings of any type/wattage/make etc for repairing including checking for repair/repalcement of underviceable parts as required and making the light fittings operatioal to give rated illumination by realing unserviceable spare parts and refixing the same at existing location or any other location including connection complete al as directed at site by Engr-in-Charge. Note :- (i) Cost of taking down carefully from existing position, bringing to MES store yard(If required for repair), is deemed to be included in this item quoted rates. (ii) Cost of supply and fixing of major items required to make the lights serviceable shall be measured and paid separately under item No 52.01 to 52.05 of this schedule.
Supply only following items to be incorporated against item No 51 here in before:
Maintenance free battery 12 volt 75 AH as per existing make
Solar panel for generation of solar energy capacity 7 watt.
Electronic battery charger with charge contoller suitable for 12 volts battery 75 Ah.
DC to AC convertor suitable for battery 12 volts.
LED security light 15 watt IP 66, pressure die cast aluminium housig and heat resistant toughened glass with lgiht intensity not less than 1500 lumens. Make :- C&S cat part No LTESSE15WLED or equivalent in PHILIPS/Crompton.
M&L for scraping, scretching, cleaning the old paint, preparation of the surface for repainting. Painting LT 09 Mtr long steel tubular pole with two coats of aluminium paint and writing pole Nos. including applying of coat of cement base paint on PCC muff all as directed by Engr-In-Charge.
M&L for scraping, scretching, cleaning the old paint, preparation of the surface for repainting. Painting LT 9 Mtr long PCC pole in Black & White strip 30 Cm a part alternaterly up to 1.5Mtr height from ground level with synthetic enmel paint, writing pole Nos. & applying one coat of cement base paint on PCC muff & remaining portion of the pole all as directed by Engr-In-Charge.
M & L for Taking down unserviceable High Mast light, etc for repairing including complete dismantling, checking for repair/replacement of unserviceable parts as required including greasing etc.and making the high mast lights operational to replacing unserviceable spare parts and refixing the same at existing location or any other location as directed at site and making electrical connections with existing wire complete all as directed. Notes - (i). Cost of taking down carefully from existing position after disconnecting electric connections, sealing cable ends, bringing to MES store yard (If required for repair), is deemed to be included in this item quoted. (ii) All T&P used for lowering/raising of High Mast lights/fittings etc are included in quotated rate.
Supply and fixing in replacement LED flood light 300 watt IP 66, pressure die cast aluminum housing and heat resistant toughened glass with light intensity not less than 20000 lumens including fixing on pole or any other location with the help of existing high mast light structure including taking down existing unserviceable one complete all as directed at site.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .