Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.2 LAccepted-AOC 1 1A VANSITART ROW 2ND FLOOR ROOM NO 2 KOL 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L1 | Accepted-AOC L1-Accepted | |
| 2 | L2₹13.2 L+₹1,908.08 (0.14%)Rejected-Finance 1 1 A VANSATTART ROW 3RD FLOOR ROOM NO 2A | L2 | Rejected-Finance Higher than L1 | |
| 3 | L3₹13.2 L+₹7,771.73 (0.59%)Rejected-Finance 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L3 | Rejected-Finance Higher than L1 |
| Sl No | Description | Qty | Unit | ALOK ENTERPRISE. A Unit of Saket Trexim Pvt. Ltd. L1 | JDJ ENTERPRISE. A UNIT OF JDJ TRADERS PRIVATE LIMITED L2 | ORIENTAL ENGINEERING CO. L3 |
|---|---|---|---|---|---|---|
| 1.00 | Supply and delivery at Site Membrane Element for existing RO unit Capacity 2000 lit/hr. suitable for installation in RO vessel of diameter 8" & length 40" as per following specification:-
a) Parmeate Flow:- 10,000 gpd (3.75 m3/d)
b) Salt Rejection:- (99.5% minimum)
c) Configuration:- Spiral Wound
d) Membrane Polymer:- Composite Polyamide
e) Nominal Membrane Area:- 365 ft2 (33.9 m2)
f) Maximum applied Pressure:- above 450 psi
g) Maximum Operation Temperature:- Not above 122°F (50°C)
h) pH range, Continuous (Cleaning):- 2.11 (1-13)
i) Maximum Feedwater Turbidity:- 1.0 NTU
j) Maximum Feedwater SDI (15 mins):- upto 5.0
k) Maximum Feed Flow:- 75 GPM (17.0 M3/h)
l) Minimum Ratio of Concentrate to Permeate Flow any Element:- 5:1
m) Maximum Pressure Drop for Each Element:- 10 psi
(Make:- Hydranautics/Dow/Toray/GF/DUPONT) | 3 | Nos | 2,43,681 ₹7,31,043 Lowest | 2,44,000 ₹7,32,000 | 2,45,230 ₹7,35,690 |
| 2.00 | SS Micron Cartridge Filter/Busket strainer for UF unit-100 micron SS, 20" long (Jumbo type).
long lumbo Type)
ID - 50mm
OD - 100mm
Length - 500mm
FlowCapacity-6m3/hr
construction, core not required,
Clean DP - 100 mbar
Maximum Operating Temperature - 200 deg C (Make-DUPONT) | 2 | nos | 58,836 ₹1,17,672 Lowest | 58,900 ₹1,17,800 | 59,000 ₹1,18,000 |
| 3.00 | Supply ond delivery at site jumbo type pre filter Cartridge of
RO Filter assembly with below mention specification.
a) ID:- 4.5"
b) O.D :- 6"
c) Length :- 20"
d) flow capaciy :- 5m3/hr
e) Core Cover Material Poly Propylene
l) Core :- Poly Propylene
g) Clean Ps 10 Psid
h) Maximum Operating Temperature :- 120°F (49°C) (Make-DUPONT) | 2 | nos | 52,993 ₹1,05,986 Lowest | 53,000 ₹1,06,000 | 53,300 ₹1,06,600 |
| 4.00 | Micron Cartridge Filter After UV 0.1 Micron20" Long Cartridge (Make-DUPONT) | 1 | no | 22,657 ₹22,657 Lowest | 22,700 ₹22,700 | 22,800 ₹22,800 |
| 5.00 | Micron cartridge Filter 0.2 Micron 20" long ( Spun Pleated cartridge)(Make-DUPONT) | 1 | no | 1,17,356 ₹1,17,356 Lowest | 1,17,800 ₹1,17,800 | 1,18,100 ₹1,18,100 |
| 6.00 | Installation and Commissioning of RO Unit Capacity 2000 ltr/ Hr Sutabile for RO Vasel diameter 8" with Through Cheaking & Testing complete. | 1 | no | 9,855 ₹9,855 Lowest | 9,870 ₹9,870 | 9,900 ₹9,900 |
| 7.00 | Add GST @ 18% | 1 | item | 1,98,822.42 ₹1,98,822.42 Lowest | 1,99,110.6 ₹1,99,110.6 | 1,99,996.2 ₹1,99,996.2 |
| 8.00 | Add Cess @ 1% | 1 | item | 13,033.91 ₹13,033.91 Lowest | 13,052.81 ₹13,052.81 | 13,110.86 ₹13,110.86 |
Tender Value
Refer Docs
EMD Value
₹26,700
Closing Date
14 Jan 2026, 4:30 pmClosed
Executive Engineer, Malda Mechanical Division, PHE
Office of the Executive Engineer, Malda Mechanical Division, PHE Dte. Doulatpur PHE complex, P.O. Maliha, Dist. Malda, PIN 732102
Replacement of Membrane Element for RO unit and other allied work of Existing Mobile Treatment Unit located at Itahar in the district of Uttar Dinajpur under Malda Mechanical Division, PHE Dte.
2025_PHED_977140_1
WBPHED/EE/MLMD/NIeT_23 of 2025-2026
Open Tender
Electrical Work/ Equipment
Item Rate
90 days
Doulatpur PHE complex, P.O. Maliha, Dist. Malda
Please refer Tender documents.
4 documents required · 4 mandatory
₹26,700
30 Jan 2026
22 Dec 2025
16 Jan 2026
22 Dec 2025
14 Jan 2026
22 Dec 2025
Supply and delivery at Site Membrane Element for existing RO unit Capacity 2000 lit/hr. suitable for installation in RO vessel of diameter 8" & length 40" as per following specification:- a) Parmeate Flow:- 10,000 gpd (3.75 m3/d) b) Salt Rejection:- (99.5% minimum) c) Configuration:- Spiral Wound d) Membrane Polymer:- Composite Polyamide e) Nominal Membrane Area:- 365 ft2 (33.9 m2) f) Maximum applied Pressure:- above 450 psi g) Maximum Operation Temperature:- Not above 122°F (50°C) h) pH range, Continuous (Cleaning):- 2.11 (1-13) i) Maximum Feedwater Turbidity:- 1.0 NTU j) Maximum Feedwater SDI (15 mins):- upto 5.0 k) Maximum Feed Flow:- 75 GPM (17.0 M3/h) l) Minimum Ratio of Concentrate to Permeate Flow any Element:- 5:1 m) Maximum Pressure Drop for Each Element:- 10 psi (Make:- Hydranautics/Dow/Toray/GF/DUPONT)
SS Micron Cartridge Filter/Busket strainer for UF unit-100 micron SS, 20" long (Jumbo type). long lumbo Type) ID - 50mm OD - 100mm Length - 500mm FlowCapacity-6m3/hr construction, core not required, Clean DP - 100 mbar Maximum Operating Temperature - 200 deg C (Make-DUPONT)
Supply ond delivery at site jumbo type pre filter Cartridge of RO Filter assembly with below mention specification. a) ID:- 4.5" b) O.D :- 6" c) Length :- 20" d) flow capaciy :- 5m3/hr e) Core Cover Material Poly Propylene l) Core :- Poly Propylene g) Clean Ps 10 Psid h) Maximum Operating Temperature :- 120°F (49°C) (Make-DUPONT)
Micron Cartridge Filter After UV 0.1 Micron20" Long Cartridge (Make-DUPONT)
Micron cartridge Filter 0.2 Micron 20" long ( Spun Pleated cartridge)(Make-DUPONT)
Installation and Commissioning of RO Unit Capacity 2000 ltr/ Hr Sutabile for RO Vasel diameter 8" with Through Cheaking & Testing complete.
Add GST @ 18%
Add Cess @ 1%
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.51 MB
Tendernotice_2.pdf
PDF • 3.22 MB
BOQ_2380691.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .