EE (ELECT-I) JDA JAIPUR
EE (ELECT-I) JDA JAIPUR
Shifting/Dismantling of LT/HT lines which are creating hurdles during road widening from Starting Point of CBI Phatak ROB to 7 no. Bus Stand, Mahal Road, Zone-9, JDA, Jaipur.
2026_JDAJP_603794_1
EE (ELECT-I)/16/2026-27
Open Tender
Electrical Works
Percentage
540 days
JDA AREA
Please refer Tender documents.
4 documents required · 4 mandatory
₹2,000
ONLINE JDA WEBSITE
₹6.8 L
Yes
12 Oct 2026
12 Oct 2026
6 Nov 2026
12 Oct 2026
2 Nov 2026
12 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Arrmoured Aluminium cable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV with H4- Grade electrolytic aluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure 'A' attached with this BSR | |||||
| 1.01 | 10 Sq. mm., 2 Core, Complete Rate Armoured | 500 | Mtr. | 152 | ₹76,000 |
| 1.02 | 16 Sq. mm., 4 Core, Complete Rate Armoured | 1,000 | Mtr. | 232 | ₹2,32,000 |
| 1.03 | 185 Sq. mm, 4 Core, Complete Rate Armoured | 3,379 | Mtr. | 1,834 | ₹61,97,086 |
| 2Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring, Compression Nut, heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as per IS 8337-1976 of following size of PVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
| 2.01 | 3.5 x 185.0 sq.mm | 155 | Set | 1,072 | ₹1,66,160 |
| 3Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 11 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
| 3.01 | 3 core 185.0 Sq.mm | 2,548 | Mtr | 1,904 | ₹48,51,392 |
| 3.02 | 3 core 95.0 Sq.mm | 409 | Mtr | 1,287 | ₹5,26,383 |
| 4Providing & Laying XLPE insulated three core Armoured Aluminium cable for working voltage 33 K.V.(E) confirming IS :7098 P - 2 with H4- Grade electrolytic aluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831 in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray including testing etc. as required of following size. OEM must have it's own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure "A" attached with this BSR . | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.83 MB
BOQ_1070810.xls
BOQ • 0.38 MB
16FBCBIPhatak.pdf
Tender Documents • 1.47 MB
16TBCBIPhatak.pdf
Tender Documents • 7.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .