SE PnW, SGTPS, MPPGCL, Brs
SE PnW, SGTPS, MPPGCL, Brs
Procurement of various current transformers installed in bus-duct for generator protections, metering circuit of Unit no.5, 1x500MW, SGTPS, MPPGCL, Birsinghpur.
2021_MPPGC_132661_1
132661
Single
Electrical Goods/Equipments
Item Wise
90 days
SGTPS, MPPGCL, Birsinghpur
As per NIT
11 documents required · 11 mandatory
₹1
Yes
Exempted
8 Jul 2021
5 Mar 2021
27 Mar 2021
5 Mar 2021
24 Mar 2021
5 Mar 2021
180 days
Current Transformer Ratio : 20000/5, 50Hz , Accuracy Class –PS VK - > 2000V Im @ VK /4 - < 150 mA R .CT - @75˚C, < 5.0 Ω S.No. – IT- 06-2090 HSV – 24000,Un Turns Ratio- 1/4000 Insulation Level- 55/125 kV STC- 135KA/1 Sec IS2705, IEC-185
Current Transformer Ratio : 20000/5, , Accuracy Class –0.2S, Burden-75 VA , ALF/ISF - < 5.0
Current Transformer Ratio : 20000/5, 50Hz , Accuracy Class –5P20, Burden-75 VA, S.No. – IT- 06-2092 Insulation Level- 55/125 kV ,HSV – 24000,Un R .CT - @75˚C, < 5.0Ω ITH /SEC. - 135KA/1 Sec IS2705, IEC-185
Current Transformer Ratio : 20000/5, 50Hz , Class –PS VK - > 600V Im @ VK /2 - < 150 mA R .CT - @75˚C, < 2.0Ω S.No. – IT- 06-2093 HSV – 24000,Un Turns Ratio- 1/4000 Insulation Level- 55/125 kV STC- 135KA/1 Sec IS2705, IEC-185
Current Transformer Ratio : 800-600/5, 50Hz , Accuracy Class –1.0 Burden- 50VA, ALF/ISF- < 5.0 S.No. – IT- 06-2094, HSV – 660,Un Insulation Level- 3/--- kV ITH/SEC – 40KA/1 Sec IS2705,
Current Transformer Ratio:-800/1, , Accuracy Class- PS VK - > 300 V Im @ VK /4 - < 30 mA R .CT - @75˚C, < 2.0Ω
Current Transformer Ratio:-800/1, , BURDEN- 15 VA , Accuracy Class- 5P20
Current Transformer Ratio : 20000/5, 50Hz , Accuracy Class –PS VK - > 2000V Im @ VK /4 - < 150 mA R .CT - @75˚C, < 5.0Ω S.No. – IT- 06-2097 HSV – 24000,Un Turns Ratio- 1/4000 Insulation Level- 55/125 kV STC- 135KA/1 Sec IS2705, IEC-185
stage.html
html • 0.04 MB
technical_154658.pdf
PDF • 0.36 MB
techsummary_154658.pdf
PDF • 0.06 MB
finance_154658.pdf
PDF • 0.39 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_154658.pdf
PDF • 0.18 MB
Order937.pdf
PDF • 0.97 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .