Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 5 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹33.2 L
Closing Date
22 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer University of Kashmir
Construction Division
Electrification for 02 Storeyed Health Centre at South Campus.
2021_UDJK_146661_1
F(UCD)(Elect. H. Cent. SC)/KU/55/21
Open Tender
Electrical Works
Item Rate
South Campus
As per NIT
6 documents required · 6 mandatory
₹1,100
Registrar University of Kashmir
Exempted
24 Nov 2021
5 Nov 2021
24 Nov 2021
5 Nov 2021
22 Nov 2021
5 Nov 2021
120 days
Amount
Wiring for light point/ fan point/ exhaust fan point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC included conduit, with modular switch, modular socket, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty) Note : Rates of Suitable PVC conduit included in above description for the follwing items (DSR 1.10.1) GROUP A( as Per NBC) From switch board to primary light point & it's loop point upto desired length and upto sub DB
Wiring for computer point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable with 6A modular switch, 2 Nos. 6A modular socket, modular plate , suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty) Note : Rates of Suitable heavy PVC conduit included in above description point taken upto sub DB
Wiring for heating point with 4 sq.mm FRLS PVC insulated copper conductor single core cable recess (, with 16A modular switch, 1 Nos. 16A modular socket, modular plate , suitable GI box and earthing the point with 4 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required..(Conduit shall be heavy duty) Note : Rates of Suitable heavy PVC conduit included in above description point taken upto sub DB
Wiring for Industrial type socket outlet point with 4 X 6 sq. mm + 1 X 6 sq. mm earth wire FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit , with 30 A, 415 V, TPN Industrial type socket outlet (Conduit shall be heavy duty), metal enclosed plug top alongwith 30 A "C" curve, TPN MCB, in sheet steel enclosure, on surface or in recess Note : Rates of Suitable PVC conduit included in above description point taken upto DB duly tested and commissioned (Required for three phase supply to three phase loads in X ray room in GF and Testing Room in First Floor@2 Supply points in each room.)
SubMain Wiring for circuit (raw power)/ submain wiring along with earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed in class heavy duty PVC conduit as required Note : Rates of Suitable PVC conduit included in above description for the follwing items
2 x 10 sq.mm + 1 x 10 sq.mm earth wire for Sub main wiring
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
4 x 16 sq.mm + 2 x 16 sq.mm earth wire for Sub main wiring
Sub Distribution Box/MCB Box Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earthbar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
16 way, Double door
12 way, Double door
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar,din bar for mounting MCBs (but without MCBs and incomer ) as required
8 way (4 + 24), Double door
Providing and fixing of 125A, 36kA 4P MCCB
Supplying and fixing of 6 Amp to 32 Amp. S/P MCB, C-Curve etc. as required in existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 5 A to 32 A rating( Preferably 20 A rating), 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole and neutral(TPN) required for three phase supply to three phase loads in X ray room in GF and Testing Room in First Floor@2 Supply points in each room.
Supplying and fixing 40-63 A rating, 240V 10 kA, “C” curve, Double pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing of following size TPN MCB, C-Curve etc. as required in existing MCB DB complete with connections, testing and commissioning etc. as required 40 A TPN ( to be installed in separate DB for exclusive Three Phase Supply.
Main Service LT Panel
Supply, installation, testing and commissioning of M.V. cubicle type totally enclosed free standing type, dust, damp and vermin proof Main Distribution Board complete with busbars, M.V. danger notice plate,space heater, power outlet, illumination lamp, Multifunction Meter indicating lamps, CT's, interconnections, with suitable capacity aluminium leads / solid aluminium strips / rods, connection of incoming and outgoing cables with thimbles, stove enameled painted and having following incoming and outgoing MCCB , Switch complete as required. Incomer : 1 no. 320A 4P microprocessor based MCCB of 25kA with Rotary Handle, shunt trip coil, adjustable O/L, S/C, E/F release. 1 no. 125A 4P Manual Change over of 25kA. 2 nos. Digital type multifunction meter with following parameters Digital multifunctional meter CT's. 2 Set of R,Y,B LED phase indicating lamp with MCB protection. 2 Set of ON,OFF & TRIP LED indicating lamp with MCB protection. BUSBARS: 400 Amp & 100 Amp TPN (25kA for 1sec) aluminium busbar chamber of suitable length with aluminium busbars. All busbars and interconnections shall be of suitable size aluminium strips. Current density of aluminium shall not be more than 0.8 Amps/ sq.mm. OUTGOING: 5 nos. 160A 4P thermal magnetic based MCCB of 25kA with Rotary Handle, shunt trip coil, adjustable O/L, S/C, E/F release. Digital Multifunction Meter having CT's for outgoing feeders. For all out goings ON/OFF LED indicating lamp with MCB protection.
Main LT Power Cable
Supplying of underground/clamped to wall with suitable clamps saddles and fixing bolts/ in ground including testing and commissioning of the following sizes of 1.1KV grade multicore aluminium conductor XLPE insulated and PVC sheathed armoured cable conforming to IS : 7098 (Part-I). Identification tags shall be provided for all cables and route markers for cables in ground as per specifications and as per instructions of Engineer- in-charge.4 core X 150 mm2 Armoured XLPE Aluminum cable
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, and refilling the trench etc as required-Above 150 sq. mm and upto 300 sq. mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required-4 X 150 sq. mm
Supplying and laying of following size DWC HDPE pipe ISI markedalong with all accessories like socket, bend, couplers etc conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required
120 mm dia (OD-120 mm & ID-103 mm nominal)
Light Fixtures and Fans
Supply and fixing of 4 feet ,20Watt LED Batten, 6500K along with accsessory assembly complete in all respects.
Providing and Fixing of 9 Watts LED Panel, round/square type, color temp: 6500K/4000K, Surface/Recessed mounted as per site requirement
Providing/fixing of 2 ft long LED batten, 12Watts, 230V complete with tube, base etc.
Supplying, erection and testing of approved make electric ceiling fan of complete with standard down rod, canopy, hanging shackle, Aluminium blades, A.C. 230-250 volts including connections with all necessary material complete of approved as required -Ceiling Fan ( ISI )-1200 mm Sweep,80-90W.
Supplying and fixing of wall fan complete with all accessories of minimum 600 mm sweep of reputed make
SITC of approved make Exhaust Fan of 200 mm (8 Inches), plastic body with mounting frame, blades AC 230-250 complete connection and including, frame bolt/ Anchor hole fastners etc. complete finished of approved as required .
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but including modular plate etc. as required complete in all respects.(for ceiling fans points) .
Providing and fixing of lighting fixtures pressure die-cast alluminium IP65 flood light luminery with high power LED 50 Watts with toughned glass.
Supplying and fixing 6 A ceiling rose i/c junction box including connections etc. as required.
Earthing System
Providing earthing stations at locations as called for Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as require i/c Constructing masonry Chamber 100x100x100 cm, inside with 75 class designation brick work in cement moryar 1:5 ( 1 cement : 5 fine sand ) for valve, with C.I.surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 ( 1 cement : 5 coarse sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand ) 12mm thick finished with a floating coat of neat cement complete as per standard design (NOTE: Actual Depth of chamber may vary as per Site conditions).
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required
Providing and fixing 20 mm X 3 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing 25 mm X 5 mm GI strip on surface or in recess for connections etc. as required.
Lightning Conductor
Providing and fixing of lightning conductor finial, made of 25mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc complete as required
Jointing G.I. tape (with another G I tape, base of the finial or any other metallic object) by riveting / nut bolting sweating and soldering etc. as required
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet oron surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For vertical run)
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing testing joint, made of 20 mm X 3 mm thick G.I. strip,along with Nos. of G.I. bolts, nuts, chuck nuts and spring washers etc. complete as required.
Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required.
INTELLIGENT FIRE ALARM SYSTEM
Supplying & laying of 2x1.5 sqmm FRLSH single core
Supplying and fixing of following sizes of heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.with 25 mm dia and 2mm thick.
Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of intelligent addressable smoke detector with built in LED, mounting base complete with all connection etc.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
Supply, Installation testing and commissioning of wall mounting rack for computer switches complete as mentioned below 6U cabinet 371.30X600X500, wall mounting with power supply and Fan etc
Supply, installation, testing and commissioning of wall mounted 4U metal rack for housing 8 port ethernet switch etc complete with Tray Mounting Fan + power supply board. Bank's hardware - port switch / patch panel.The cabinet frame shal have minimum depth of 500mm to accomadate 8 port ethernet switch
Supply, installation, testing and commissioning of approved make approved brand 32 -port Ethernet Gigabit switch complete in all respects
Supply, installation, testing and commissioning Wireless Acess points/Wi-fi points of Netgear/Cisco./Huwai /Dlink approved make approved brand complete in all respects
Supply, Installation testing and commissioning of patch cord as mentioned below :-CAT 6 RJ45 Patch Cord F/UTP 1 Mtr.
Supply, Installation testing and commissioning of patch cord as mentioned below :-CAT 6 RJ45 Patch Cord F/UTP 2 Mtr.
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.(1 run of cable)
Supplying and fixing of following sizes of heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required with 25 mm dia ,2mm thick
Supplying and fixing of shock treatment chart (prescribed under I.E.rules) duly framed with glass and supported from back with hard board with supply of all material labour T & P etc for proper completion of work. (Approx front area = 1.20 sq M)
PORTABLE FIRE EXTINGUISHERS 'Providing and fixing ABC stored pressure dry chemical powder (monoammonium phosphate) Fire Extinguisher IS : 13849 latest revision manufacturer and of CRCA sheet in welded construction, finish with epoxy polyster powder coated complete with brass forged ball valve, gun metal cap and nozzel, including initial filled and wall suspension bracket (suitable for fighting in class 'A', B & 'C' that is wood, textile, flammable liquid, electric and gases. 4 Kg. Capacity
sypplying of 1000 mm wide, 2000mm length, 1.1kV grade, antiskid rubber mat, As per IS 15652-2006 and of reputed make to be spread in front of the 415 V switchgear panels / DBs etc.
Supplying and Erection of Steel Tubular poles (7.5m) complete with base plate & top cap for tapping point including drilled holes for supporting channel including carriage chargers, loading/unloading and Erection of steel tubular or rail pole strut in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling i/c Painting of poles with primer coat/paint coat
Providing and fixing of 0.05 ACSR Rabbit conductor having ISI mark
Supplying and erection of galvanised 'D' iron clamps complete with shackle insulator (75 mm X 90 mm),G. I. bolts, nuts and washers, coach screws etc. as required.
Providing,fixing, testing and commissionig of Manual change-over 4P TYPE, Hinged type single door, surface type 200 Amp.
Supply, installation, testing & commissioning of 2 kVA 1 phase Inverter with 2x180AH 12V tubuler Batteries including input/output leads/ Switch sockets etc. to make the system operational. Note: Item Should have minimum of two years Warrenty and free service.
Supplying and fixing approved make fire buckets of 24 gauge galvanized steel sheet with 4 no sand buckets, standard 9 liters capacity as per IS:2546:1974 and of round bottom shape, painted white inside and red outside and black on the bottom, inscribed with letter "FIRE" in black and gold. Cost shall be inclusive of providing MS stand duly painted over a coat of primer (one stand shall be suitable for hanging 4 buckets).
First Aid Kit as per Red Cross Standards, complete with Medicines for Burns, Cut Vomiting , Swelling , Cotton Wool, Cotton Bandage , Surgical Sprit etc placed in a wall mounting box with 6mm thick front hinged glass cover, with the sign " +" and the inscription "FIRST AID" in Red Paint - Overall size not less than 450mm x 300mm x 200mm deep in two tier shelf pattern.
Supplying, fixing, testing and commissioning of following Amperes of MCCBs with spreader links 200 Amp 25KA 4 pole
Supplying, fixing of MCCB MS door type Enclosure suitable for 125 - 160 Amp 4 P MCCB
HUBBI ELECTRICALS
M/S TAJ CORPORATION
M/s J. K. Electrical Works
M/S MOHD SHAFI ITOO
IMRAN ELECTRICALS AND SUPPLIERS
stage.html
html • 0.03 MB
finance_316598.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .