Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.0 LAccepted-AOC 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹38.5 L+₹63,002 (1.66%)Rejected-Finance | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹41.2 L+₹3.3 L (8.77%)Rejected-Finance LINE PAR NAI BASTI OSARH ROAD FARIDPUR DISTT BAREILLY PIN 243503 | FARIDPUR | BAREILLY | BAREILLY | 243503 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹42.7 L+₹4.8 L (12.6%)Rejected-Finance KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹43.1 L+₹5.2 L (13.6%)Rejected-Finance VILL GAIDUA PO HARIATARA P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPORE ST WEST BENGAL PIN 721 304 | MEDINIPUR WEST | WEST BENGAL | 721304 | L5 | Rejected-Finance Not Being L1 |
| Sl No | Description | Qty | Unit | M/s Tekcon International L5 | Guru Charan Mahata L4 | ALLIANCE L7 | Kalpana Traders L2 | M/s Antara L6 | M/S ELECTROVISION L8 | M/S OM BUILDERS L3 | SENCO L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 240 sqmm 3.5 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (Note: Rate of under ground cable includes earth Work, sand cushioning, brick or PCC covering, light Grade GI tubing where necessary,testing etc.) | 300 | RM | 1,780 ₹5,34,000 | 1,800 ₹5,40,000 | 1,670 ₹5,01,000 | 2,100 ₹6,30,000 | 1,130 ₹3,39,000 Lowest | 2,000 ₹6,00,000 | 1,673 ₹5,01,900 | 1,619 ₹4,85,700 |
| 2.00 | All as per item No-01.00 here-in-before but of size 25 Sqmm 3.5 Core complete all as specified. | 100 | RM | 300 ₹30,000 | 450 ₹45,000 | 325 ₹32,500 | 350 ₹35,000 | 298 ₹29,800 | 300 ₹30,000 | 296 ₹29,600 | 254 ₹25,400 Lowest |
| 3.00 | All as per item No-01.00 here-in-before but of size 16 Sqmm 4 Core complete all as specified. | 90 | RM | 230 ₹20,700 | 350 ₹31,500 | 266 ₹23,940 | 280 ₹25,200 | 198 ₹17,820 Lowest | 225 ₹20,250 | 245 ₹22,050 | 199 ₹17,910 |
| 4.00 | Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable complete all as specified and as directed. | 188 | Cum | 350 ₹65,800 | 450 ₹84,600 | 270 ₹50,760 | 180 ₹33,840 | 115 ₹21,620 Lowest | 350 ₹65,800 | 320 ₹60,160 | 190 ₹35,720 |
| 5.00 | Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed. | 112.8 | Cum | 100 ₹11,280 | 65 ₹7,332 Lowest | 140 ₹15,792 | 150 ₹16,920 | 98 ₹11,054.4 | 200 ₹22,560 | 210 ₹23,688 | 90 ₹10,152 |
| 6.00 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed. | 75.2 | Cum | 60 ₹4,512 Lowest | 250 ₹18,800 | 90 ₹6,768 | 160 ₹12,032 | 280 ₹21,056 | 416 ₹31,283.2 | 275 ₹20,680 | 100 ₹7,520 |
| 7.00 | Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. | 38.72 | Cum | 2,000 ₹77,440 | 2,500 ₹96,800 | 1,120 ₹43,366.4 | 1,550 ₹60,016 | 1,000 ₹38,720 Lowest | 2,800 ₹1,08,416 | 2,150 ₹83,248 | 2,400 ₹92,928 |
| 8.00 | Supply and laying sub class B bricks of size 25cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed. | 3,824 | Each | 12 ₹45,888 | 18 ₹68,832 | 15 ₹57,360 | 7 ₹26,768 Lowest | 11 ₹42,064 | 12 ₹45,888 | 14.8 ₹56,595.2 | 13 ₹49,712 |
| 9.00 | M&L horizontal boring for 80 mm dia across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed.
Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate.
(ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'. | 20 | RM | 300 ₹6,000 Lowest | 1,500 ₹30,000 | 1,800 ₹36,000 | 750 ₹15,000 | 800 ₹16,000 | 850 ₹17,000 | 875 ₹17,500 | 700 ₹14,000 |
| 10.00 | M&L 80 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed. Make: Tata/Jindal/Bansal | 12 | RM | 1,000 ₹12,000 | 990 ₹11,880 | 1,200 ₹14,400 | 1,050 ₹12,600 | 1,100 ₹13,200 | 1,200 ₹14,400 | 700 ₹8,400 Lowest | 815 ₹9,780 |
Tender Value
₹47.8 L
EMD Value
₹95,500
Closing Date
17 Jun 2025, 6:00 pmClosed
Major MK Yadav, GE
GE (AF) Kalaikunda PO Kalaikunda Air Field Dist Paschim Medinipore State West Bengal Pin 721303
Special reapair/Replacement of internal electrical work external and allied works at staff quarters of KV No-1 at AF Stn Kalaikunda
2025_MES_699435_2
C/8091/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AF STN KALAIKUNDA
Class D category b (i)
7 documents required · 7 mandatory
₹500
GE AF KALAIKUNDA
₹95,500
6 Aug 2025
27 May 2025
19 Jun 2025
27 May 2025
17 Jun 2025
3 Jun 2025
Amount
Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 240 sqmm 3.5 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete as specified and as directed. (Note: Rate of under ground cable includes earth Work, sand cushioning, brick or PCC covering, light Grade GI tubing where necessary,testing etc.)
All as per item No-01.00 here-in-before but of size 25 Sqmm 3.5 Core complete all as specified.
All as per item No-01.00 here-in-before but of size 16 Sqmm 4 Core complete all as specified.
Excavation in trenches in soft/loose soil not exc. 1.5 metre wide and not exc. 1.5 metre in depth and getting out for taking up / laying under ground electric cable complete all as specified and as directed.
Returning, filling in, including spreading levelling watering and well rammming in layers not exceeding 25 cms in depth complete all as specified and as directed.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply and lay dry river sand filling for under ground cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed.
Supply and laying sub class B bricks of size 25cmx12.5cmx7.5cm (+/-10% tolerance) for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and as directed.
M&L horizontal boring for 80 mm dia across the existing road without disturbing the road surface for inserting GI pipe complete all as specified and as directed. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'.
M&L 80 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed. Make: Tata/Jindal/Bansal
M&L 50 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and as directed. Make: Tata/Jindal/Bansal
Dismantling of Existing old Unsv ACSR Conductor of any size from pole and removing complete from the site
Dismantling of broken/cracked/Unsv LT Pin/Shakle insulator of any make and any size complete all as specified.
Dismantling of old rusted cross arms bracing support,clamps, and back plate of any sections from poles setting aside complete all as directed at site
S&F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete incl removal of old unsv fitting all as directed by Engineer-in-Charge. Make - Havells , CAT No - ENDURASUNDOWNSL25WLED765PASYBOTGIHD or equivalent to Crompton/Bajaj/Philips.
M&L Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I 2009 connected to pole/LT Panel all as specified and testing on completion including. Necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade, for protection of earth strip complete all as specified and directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate.
Taking up/down old unserviceable GI/PVC/PPR pipes from trenches, walls, floors, ceiling and duct etc for repair including cleaning with all fittings of any type complete all as specified and as directed.. Note: Excavation/earth work will be measured and paid separately under relevent item.
M&L laying of GI tubing 80 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etc as required at site and laid in trenches incl connecting with existing lines all as directed. Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . Make - Tata/Jindal/Prakash
All as per item No 18.00 above here-in-before but of size 50 mm bore, complete all as specified and as directed . Make - Tata/Jindal/Prakash
All as per item No 18.00 above here-in-before but of size 40 mm bore, complete all as specified and as directed . Make - Tata/Jindal/Prakash
All as per item No 18.00 above here-in-before but of size 20 mm bore, complete all as specified and as directed . Make - Tata/Jindal/Prakash
M&L fixing GM globe/gate valve 50 mm bore with iron wheel head, screwed both ends for iron/PPR pipes, ISI marked, conf to IS including taking down old unserviceable complete all as specified and directed by Engr in charge. Make : ZOLOTO / LEADER or equivalent make Note: Union or long screw have to provided before fixing of gate valve.
All as per item No 19.00 above here-in-before but of size 40 mm bore, complete all as specified and as directed . Make : ZOLOTO / LEADER or equivalent make
All as per item No 19.00 above here-in-before but of size 20 mm bore, complete all as specified and as directed. Make : ZOLOTO / LEADER or equivalent make
M&L road cutting of WBM/PCC path/road and passing the pipe line below and making the disturbed surface as per existing pattern all as directed and specified.
M&L PCC (1:4:8) type D2 using 40 mm graded stone aggregate as in motor foundation, filling and mass concrete including demolation of concrete of any description complete all as specified and directed.
Construction of brick masonry valve pit of size 60cm x 60cm x 60cm (internal dimensions) with one brick thick wall in cement mortar 1:4 on 100 mm thick P.C.C. 1:4:8 type D2 (using 40mm graded broken stone aggregate) as in foundation lean concrete, including PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) as in bedding and coping and 10mm thick cement plaster in CM (1:4) internally and externally up to 15cm below ground level providing valve pit 25 x 25 x 4mm angle iron frame all-round the fixed point by means of 4Nos holdfast 150mm long made out of flat iron 25 x 3mm embedded in PCC block (1:2:4) type B-1 (using 20mm graded crushed stoned aggregate) including provision of hinges welded with angle iron frame and MS cover 3mm thick, MS handle of suitable and size welded with MS cover and suitable locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer including necessary excavation and earth work in soft/loose soil complete all as specified and directed.
M&L earthing complete with galvanized steel plate electrodes of size600x600x6mm thick burried directly in ground with earth pit not less than 2.25 meter deep below normal ground level with top edge of plate not less than 1.5 meter below normal ground level connected to galvanised wire 4.00 mm earth lead by means of nuts, bolts, checknuts and washers including 15 mm bore galvanized iron pipe, medium grade for protection of earth lead upto the length of 7.5 meter towards test terminal and 20 mm bore galvanized iron pipe, medium grade for watering, and providing of charcoal and common salt in alternate layers, includig necessary earth work in any type of soil and including PCC pit in PCC 1:2:4 with provision of wire mesh and funnel, complete all as shown in electrical plate No 5 of SSR Part- I including testing on completion all as directed and as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc for taking credit ( credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and as directed.
M&L point wiring complete for one power point for one metal plug & socket for AC or one socket for geyser point on independent board with 4.0 Sqmm multistranded copper conductor single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit not less that 20mm dia and conduit accessories (ISI marked) concealed in wall/fixed to roof, ceiling etc including provision of 4.0 Sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI marked) as earth continuity conductor connected to common earth dolly, including cutting chases of existing wall for conduits and fixing for Metal Plug and socket boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCBs or bus bar shall be done through proper size copper/brass thimbles.
M&L point wiring with 1.5 sqmm single core PVC insulated unsheathed FR-LS cable 1100 volts grade (ISI marked) with multistranded copper conductor with proper colour coding drawn through and including non-metallic rigid PVC medium grade conduit and conduit accessories (ISI Marked) concealed in wall/fixed to roof, ceiling etc including provision of 1.5 sqmm PVC insulated multistranded unsheathed copper conductor cable FR-LS (ISI Marked) with proper colour coding as earth continuity conductor connected to common earth dolly, modular sheet steel sunken terminal box of appropriate size suitable for modular switch/ fittings concealed in walls, with modular back plate, top cover fixed flush to wall for housing switches, socket outlets, fan regulators etc duly earthed including cutting chases of existing wall for for conduits and sinking for boxes and making good to the disturbed surface of wall/floor and matching with existing specifications. Connections of cable with MCB's or bus bar shall be done through proper size copper/brass thimbles all as specified and as directed for the following :-
One light point controlled by one way switch 5/6 amps.
One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps.
One socket out let 5/6 amps point on the independent board
One socket out let 5/6 amps point on the same board
One bell point controlled by one way switch 5/6 amps.
One light point controlled by two way switch 5/6 amps.
All as per item No 26.00 above but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and directed
S&F Modular switch, single pole, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F Modular switch, single pole, Two way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F Modular switch, single pole, one way, 16 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F Modular shuttered Socket outlet 5 Pin, 6 Amp, 2 Module, 230 volts, ISI marked complete all as specified and as directed.
S&F Modular shuttered Socket outlet 6 Pin, 6/16 Amp, 2 Module, 230 volts, (ISI marked) complete all as specified and as directed.
S&F Modular bell push, one way, 6 Amp, 1 Module, 230 volt, ISI marked complete all as specified and as directed.
S&F stepped type modular electronic fan regulator 120 watt 2 module suitable for 1200/1400 mm sweep energy saving fans,ISI marked complete all as specified and directed.
S&F Call bell Ding dong, 230 Volt single phase all as specified and directed.
S&F lamp holder, insulated body, with back plate suitable for batten/angle fittings complete all as specified and directed.
S&F LED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and directed.
S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed.
S&F White cover plate with frame, 1/2 module complete all as specified and directed.
S&F White cover plate with frame, 3 module complete all as specified and directed.
S&F White cover plate with frame, 6 module complete all as specified and directed.
S&F Metal flush box 1/2 module complete all as specified and directed.
S&F Metal flush box 3 module complete all as specified and directed.
S&F Metal flush box 6 module complete all as specified and directed.
S&F LED 20 Watt tube light fitting intregated type,operational voltage of 170 volts to 270 volts, frequency of 50 Hz, lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battens complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fitting including taking down old unserviceable complete all as specified & directed. (Make :Havells,Cat part No LUMINIERPLUOBS20WLED830SPCSSIND or equivalent of Philips/Bajaj/CG.)
Fixing only LED Tube light of any watt on wall/surface mounted fixed with 02 Nos of PVC round/ square blocks, screws etc complete all as specified.
S&F LED 9/10 Watt tube light fitting intergated type, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 100 lumens per watt, , integrated electronic driver with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CCT of 6500K, power factor of minimum 0.95 polycarbonate housing with aluminium, complete suitable for surface mounting on wall, complete fitting including connecting with PVC insulated multistranded copper flexible cable 1.5 sqmm three core, and PVC round block white colour x 2 Nos for mounting of fitting complete all as specified & directed. (Make :Havells,Cat part No LUMINIERPLUSBS10WLED830SPCSSIND or equivalent of Philips/Bajaj/CG.)
Fixing only LED Tube light of any watt on wall/surface mounted fixed with 02 Nos of PVC round/ square blocks, screws etc complete all as specified.
Taking down carefully Ceiling fan from its original position and refixing / hanging after B/R plaster work complete all as specified and directed.
M&L painting of ceiling fan complete, in situ with synthetic enamel paint by spraying including filling cavities with filler one coat after cleaning all dust etc, all as specified and as directed.
S&F of ceiling fan with all accessories 230 volts, single phase, AC, power rated 26-32 Watt, service value not less than 7.0, 1200 mm Sweep BEE 5 Star rated ISI Marked BLDC complete pre-wired with three core cable completed all as specified and directed. Make - Crompton/ Havells / Bajaj/ Usha.
S&F heavy duty exhaust fan 300 mm sweep MS body with antidust painting, 4 blade with heavy duty motor and double ball bearing, 1320 RPM, single phase 230/240 volts copper wounds, Air delivery -1600 CMH complete with all accessories as bird guard/ louvers shutters etc incl making connections with 3 core flexible multistranded copper conductor of size 0.75 Sqmm run through flexible pipe all as specified and as directed including cutting holes and making good the disturbed surfaces of walls in CM(1:4) and finishing the surface as per existing color scheme complete all as specified and as drected.
S&F exhaust fan with louvers 250 mm sweep (Plastic rust proof Body and blade), energy efficient, AC single phase 240 volts, 50Hz connecting up complete including making holes and plastering the disturbed surfaces to make smooth and built in louvers and provision of 3 core flexible multistranded copper conductor of size 0.75 Sqmm from ceiling rose to fan all as specified and as directed.
M&L Sub main wiring with two single core PVC insulated unsheathed cable 1100 volts grade, 6 Sqmm size with multistranded copper conductor, FRLSH cable as per IS 694: 2010 drawn in but including PVC casing capping not less than 25 mm ISI marked including all accessories of casing caping as approved by EIC including PVC insulated unsheathed 6.0 Sqmm cable with multistranded copper conductor green PVC insulated as continous earth conductor cable connected to earth dolly complete all as specified and directed. ( 2 x 6.0 sqmm + 1 x 6.0 Sqmm earth wire).
S&F sheet metal enclosure for VT DB TPN, MCB DB TPN 4 way (with provision for MCCB as INCOMER and MCB as out going), Confirming to IS as per IEC 61439-3, IP 43,double door including 63 Amp, 25 kA,TP MCCB as incomer (Vertical type double door, 63 Amps MCCB rate inclusive) including fixing the DB box flush in wall of any type and making good the distrubed surface to match as the existing complete all as specified and directed .
S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, 415Volt IP-20 protection suitable for fixing MCB"S/lsolators with and including taking down old one complete all as specified and directed. Make : Legrand/ Hager/ABB/C&S.
S&F MCB distribution boards (DBs) with sheet metal enclosure, double door, IP 43 protection, 240 Volts, 8 way, single pole and neutral, with 200 Amps rated copper bus bar (as per OEM), neutral link, ertth link earthing studs, suitable for fixing MCBs, without MCBs fixed flush to wall/other surface complete all as specified and as directed.
S&F MCB, Single pole & neutral, 32 to 63 amps, 240 volts, ‘C’ curve, 10KA all complete all as specified and as directed.
S&F MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete all as specified and as directed.
S&F epoxy powder coated sheet metal enclosure with socket plug top and MCB, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, 240 Volts, C Series current carrying capacity 10 kA, incl necessary connection complete all as specified and directed.
S&F electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as specifed and directed.
Supply, fabrication, installation, testing and commisioning of LT 3 Phase 4 wire 450 Volts system, Outdoor type , factory made water and vermin proof protection floor mounted cubical type LT Panel fabricated from 3.15mm thick CRCA sheet for outer shell & 2.0 mm thick for inner shell with angle iron 50x50x6 mm double door front and back openable type, double door system, hinged opening, rubber lining locking arrangement with anticorrosive paint and epoxy powder coated with pure polyster siemens grey structure, protection class IP-54 fully compartment design with 4 nos of busbar made of copper of ETP grade suitable for 200 Amp (size of copper strip should not be less than 25x6mm for each phase and neutral) pre wired with suitable size of copper strip /copper wire with colour code for connecting outgoing MCCB/MCB including suitable Al earth strip confirming to IS with danger notice plate, cable gland, cable connection with proper lugs, PCC foundation for fixing LT panel with PCC 1:3:6 type C1 using 20mm grade stone aggregate as in padding on top and grouting bolts etc for panel. Note : (i) Cost of earth work and PCC are deemed to be inclusive in this item (ii) the schematic diag of LT pannels shall be approved by GE before procurement.
Kalpana Traders (BID ID -3324165)
M/S OM BUILDERS (BID ID -3326581)
Guru Charan Mahata (BID ID -3317125)
M/s Tekcon International (BID ID -3315502)
M/s Antara (BID ID -3325574)
ALLIANCE (BID ID -3319004)
M/S ELECTROVISION (BID ID -3326028)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .