Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.4 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹49.8 L+₹3.3 L (7.17%)Rejected-Finance ATR MAIN ROAD GARACHARMA II OPP MAHINDRA JADWET SHOWROOM SRI VIJAYA PURAM 744105 | SRI VIJAYA PURAM | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹49.9 L+₹3.5 L (7.52%)Rejected-Finance ROOM NO 01 1ST FLOOR SIMA TRADING BUILDING SURVEY NO 268 GARACHARMA VILL SRI VIJAY PURAM 744105 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744105 | L3 | Rejected-Finance Not being L1 | |
| 4 | Rejected-Technical | - | Rejected-Technical Due to not having category | |
| 5 | Rejected-Technical | - | Rejected-Technical Due to not having category |
Tender Value
₹43 L
EMD Value
₹86,000
Closing Date
23 May 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE, Minniebay, Sri Vijaya Puram
GE, Minniebay, Junglighat (PO), Sri Vijaya Puram -744103
REP REPL OF SPLIT ACS, WINDOW ACS, TOWER ACS, REFRIGERANT PIPING SYSTEM, SUMMER COOLING APPLIANCES CONTROLS AND OTHER ALLIED WORKS AT INS UTKROSH, NTS, PORT MOUNT AREA UNDER AGE EM-I OF GE MINNIEBAY
2025_MES_706287_1
8557/E8
Open Tender
Civil Works
Item Rate
GE, Minniebay, Sri Vijaya Puram
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
Yes
GE Minnie Bay
₹86,000
Yes
19 Jul 2025
2 May 2025
26 May 2025
2 May 2025
23 May 2025
16 May 2025
Amount
M&L for complete carryout the servicing to AC’s & Refrigerator including taking down from the position, dismantling the sheet metal parts, blowing out the dust, carryout the chemical cleaning to chocked cooling coil & condenser coil, by spraying the dilated chemical cleaning agent, till remove complete chocking, flushing across the coils, cleaning all the sheet metal parts, filter, grill and fixing all the dismantled parts with sheet metal screws, lubricating the fan motor bush / bearing, checking all the electrical connections, renew any burned pitted lugs / clip and fixing back to position and testing complete all as specified and as directed by Engineer in charge Note: Gas Charging if required shall be measured and paid separately Note for item No 1 & 2:- The servicing/cleaning of AC’s, Water cooler & Refrigerator once in every 03 months (Job per each Split AC/Water cooler & refrigerator for 3 months will be measured and paid separately)
Split AC 1.5/2TR.
Ductable/Vertical type AC 3.5/4.5 TR.
Refrigerator 165/180/195 ltr.
Refrigerator 240/280/310/320 ltr.
M&L for Servicing of Water Cooler for any capacity of any make including opening the machine on site removing the dust from body, cleaning condenser, cooling coil ,fan/ blower drum, water tank ,oiling/ greasing to fan motor, checking all the electrical connections necessary testing and commissioning complete all as specified and as directed are as under:-
Water cooler capacity 40/80 ltr.
Water cooler capacity 60/120 ltr.
M&L for complete repair to out door unit of AC Unit, including taking down all the components tinkering the rusted portion, renewal of complete rusted sheet metal parts, with the same thickness M.S. sheet as per the existing size & shape including cutting, bending welding, drilling etc., including renewal of all nut & bolts sheet metal screws, mounting legs, rubber bushes, and cleaning & prepare the surface thoroughly, applying two coat of synthetic enamel paint over a coat of red oxide primer fixing of all components, brazing the refrigeration piping and shifting to its original position and connecting up all electrical connections and testing complete all as specified as directed by Engineer-in-Charge as under:-. Note : (i) Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, Refrigerant gas, required to and from Transportion and Handling. (ii)spares required shall be measured and paid separately
Split AC 1.5/2TR.
Ductable/Vertical type AC 3.5/4.5 TR.
M&L for complete scraping out the crusting painting of the complete body of out door unit metallic surface, cleaning the surface thoroughly, apply putty / metal paste, prepare the surface, apply two coats of synthetic enamel paint over a coat of red oxide primer for any capacity of AC’s. complete all as specified and as directed by Engineer in charge
M&L for leak testing of AC’s, Refrigerator & Water Coolers by removing refrigerant from the unit, flushing the refrigeration system thoroughly with CTC, Nitrogen gas, leak test and locating the leaks, rectifying the leaks, by brazing the joints, replacing the damaged copper pipes, silver rod / copper. Pressure testing, dehydrating, vaccumization, gas charging testing & commissioing the system the work include required strainer, N2 gas, and transportions handling the unit complete all as specified and as directed by Engineer in charge of following as under:-
Split AC 1.5/2TR.
Ductable/Vertical type AC 3.5/4.5 TR.
Refrigerator 180/286/310 ltr.
Water cooler 40/80 ltr & 60/120 ltr
M&L for copper brazing for jointing two copper tube of any size in the work of airconditioning carrying out carefully with safety precautions including necessary testing complete all as specified and as directed by Engineer in charge as under:-
S&F running capacitor of compatible for AC & Water coolers capacity including taking down old unserviceable one complete all as specified and as directed as under:-
36 to 50 MFD.
1.5 to 10 MFD.
S&F Outdoor condenser coil made up of copper tubes suitable for Split/Ductable/Vertical ACs including taking down old unserviceable one complete all as specified and as directed as under:-
Split AC 1.5/TR.
Split AC 2TR.
Ductable/vertical AC 3.5/4.5TR.
S&F Outdoor condenser coil made up of aluminium tubes suitable for Split/Ductable/Vertical ACs including taking down old unserviceable one complete all as specified and as directed as under:-
Split AC 1.5/TR.
Split AC 2TR.
Ductable/vertical AC 3.5/4.5TR.
S&F air conditioner mounting bracket heavy duty GI steel/MS, Powder coating finish inclusive of nuts and bolts for mounting the bracket on existing surfaces and making the existing surfaces good including taking down old unserviceable one complete all as specified and as directed by Engineer in charge.
S&F PC board compatible for split/Vertical AC of any capacity including taking down old unserviceable one complete all as specified and as directed as under:-
Split AC 1.5TR.
Split AC 2TR.
Inverter type indoor unit Split AC 1.5TR.
Inverter type indoor unit Split AC 2TR.
Inverter type outoor unit Split AC 1.5TR.
Inverter type outoor unit Split AC 2TR.
Vertical type AC 3.5/4.5TR.
S&F Air filter compatible for existing model of split AC of any capacity on existing location including taking down old unserviceable one complete all as specified and as directed as under:-
Split AC 1.5TR.
Split AC 2TR.
S&F in replacement of remote control compatible for any model of split AC of 1.5/2.0 TR capacity on existing location complete all as specified and as directed by Engineer in charge
S&F in repair of single shaft outdoor unit blower fan motor suitable for any model of split/vertical type AC & water coolers of any capacity, single/ double speed, single phase, 230Volts, AC complete all as specified and as directed by Engineer in charge as under:-
Split AC 1.5TR.
Split AC 2TR.
Ductable/vertical type AC 3.5/4.5 TR.
Water cooler 40/80 ltr & 60/120 ltr
S&F in repair indoor swing motor suitable for any make/model of split type AC, 12V DC complete all as specified and as directed by Engineer in charge as under:-
Split AC 1.5TR.
Split AC 2TR.
Ductable/vertical type AC 3.5/4.5 TR.
S&F in repair fan blade suitable for existing model outdoor unit of split type AC & water cooler of capacity complete all as specified and as directed by Engineer in charge as under:-
Split AC 1.5TR.
Split AC 2TR.
Ductable/vertical type AC 3.5/4.5 TR.
Water cooler 40/80 ltr & 60/120 ltr
S&F in repair single shaft indoor unit blower fan motor suitable for any model of split type AC of any capacity, single/ double speed, single phase, 230Volts, AC complete all as specified and as directed. by Engineer in charge as under:-
Split AC 1.5TR.
Split AC 2TR.
S&F in repair indoor unit consist of copper cooling coil for AC Capacity any make/model including connection of existing electrical cables and copper tubing complete all as specified and as directed by Engineer in charge
Split AC 1.5TR.
Split AC 2TR.
Ductable/vertical type AC 3.5/4.5 TR.
S&F in repair of indoor unit consist of copper cooling coil for Refrigerator of capacity 165 to 320 ltr any make/model including connection of existing electrical cables and copper tubing complete all as specified and as directed by Engineer in charge
M&L for taking down the defective ACs/Refrigerator and Water Cooler of the following capacity, taking out the defective unserviceable hermetically sealed compressor from the unit, replacing the compressor with new compressor of the same capacity, fixing to the unit inter connecting the refrigerating lines, flushing out the cooling coil & condenser, removal the coil & carbon thoroughly, cleaning with CTC, leak testing, pressure testing with Nitrogen gas, dehyderating, Vaccumization, reinstalling the same in its Original position connecting up all electrical connection and Testing & Commissioning complete all as specified as directed by Engineer-in-Charge. Note : (i)Rate quoted is deemed to be inclusive of cutting, welding, brazing, sealing the refrigerant tubing, replacement of strainer, CTC, Nitrogen gas, required to and from Transportion and Handling. (ii) spares required shall be measured and paid separately
Split AC 1.5TR.
Split AC 2TR.
Ductable type AC 3.5TR.
Vertical type AC 4.5TR.
Refrigerator 165 to 320 ltr.
Water cooler 40/80 ltr & 60/120 ltr
S&F in repair sheet metal enclosure with socket plug top single pole and neutral enclosure with two pin earth plug and socket complete with one MCB SP of capacity 6 to 32 Amps complete all as specified and as directed by Engr-in-Charge
S&F in repair PVC insulated, multistranded FRLSH copper conductor 1100 volts of size 2.5 sqmm, 3 core complete all as specified and as directed by Engr-in-Charge
Supply and fixing as in repair of Copper tubing of size, flare size conforming to relevant IS complete all as specified and as directed for the following:-
Copper tubing of size 1/2".
Copper tubing of size 1/4".
Copper tubing of size 3/8".
Copper tubing of size 5/8".
S&F in repair nitrile insulation of copper tubing for split unit of any capacity & any size from indoor to out door unit complete all as specified and as directed.
Supply and fixing as in repair as per existing make and refixing the all electrical connection making suitable fixing arrangement as required necessary testing and commissioning complete all as specified and as directed of the following as under:-
MCB TP 32 Amps 10KA breaking capacity, 'C' curve.
MCB SP 6 to 32 Amps 10KA breaking capacity, 'C' curve.
Supply and fixing as in repair of Voltage Stabilizer of any capacity for automatic operation single phase naturally air cooled, indoor type, designed for input variation between 170V to 250V with output voltage stablizeed at 230V with accuracy of 2.5% as per existing make and refixing the all electrical connection making suitable fixing arrangement as required of existing place, necessary testing and commissioning complete all as specified and as directed of the following size of capacity as under:-
Voltage stabilizer of capacity 5 KVA..
Voltage stabilizer of capacity 4 KVA..
Voltage stabilizer of capacity 3 KVA..
Voltage stabilizer of capacity 2 KVA..
Supply and fixing as in repair of drain outlet PVC pipe 15mm dia connected from rear side of AC/water coolers upto drain with necessary clamps and fittings fixed on wall and floor of existing place, necessary testing complete all as specified and as directed of capacity as under:-
Drain outlet PVC pipe 15mm dia.
Drain outlet PVC pipe 40 mm dia.
Supply and fixing as in repair of Split AC suction/discharge valve of big/small size and float valve of water cooler as per existing make and refixing the all coper tubing connection including provision of suitable size of flare nut complete all as specified and as directed.
suction valve of big/small size.
Discharge valve.of big/small size.
Float valve of water cooler.
Supply and fixing of indoor/outdoor unit of split type AC capacity having 5 star rating complete with all accessories such as installation plate with screws, blower motor, swing motor, filter and PCB etc duly prewired including reconnecting of existing refrigerant piping, electrical connections, drain pipe etc and testing after taking out old one deposit to MES store yard complete all as specified and directed. Make :- Daikin, Carrier, voltas,bluestar
Indoor unit of split type AC of capacity 1.5TR.
Outdoor unit of split type AC of capacity 1.5TR.
M&L for shifting of split AC any size of capacity with all accessories and fixing it to other location as directed by Engr-in-Charge at site, connecting cable connection with connecting accessories, including mounting bracket all as specified and directed by Engineer in charge
Supply and charging refrigerant gas R134A/R410A/R32 or equivalent existing gas as per OEM for gas charging for ACs/ water coolers/ refrigerators complete one time for topping up or making full qty as per the pressure requirement of plant and /testing for any leakage and rectifying the same as directed by Engineer in Charge and testing on full load condition for 8 Hrs period. (i) Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas and necessary receipt voucher shall be submitted on this effect.
Supply and install hi wall split units indoor/outdoor complete with cordless remote control unit for better indoor air quality with minimum 5 star rating of any capacity including required gas charging complete all as specified and as directed and dismantling old defective split ACs and deposit to MES store yard of the following as under:- Note: (a) The cost of copper tubing of any length from indoor to outdoor unit, remote with batteries, refrigerant gas, compressor oil, tools & plants for fixing of outdoor unit at any height and making good disturbed surfaces is deemed to be included in the quoted rate. (b) Drilling of the wall should be done by core cutting machine and making good disturbed surfaces is deemed to be included in quoted rate.
Split AC of Capacity 1.5 TR.
Split AC of Capacity 2.0 TR.
Supply and fix water cooler with in built water purifier capacity with comfort level water outlet temperature 17oC rated condition 60 LPH, running current in 4.5A, 700W, RO system and water cooler operating volt 180 - 250 Volts, single phase, 50 Hz, thermal insulation for storage tank, body storage tank material SS 304 and 5 stages of purification, having approx storage capacity of 80 ltrs and normal cooling capacity of 40 Ltrs / hr including suitable pre-filter of complete all as specified and as directed by Engineer-in-Charge.
Supply, installation, commissioning of Glass Top Deep Freezer of capacity 320 ltr, single phase 240 volt, 50 Hz complete all as specified and as directed and dismantling old defective deep freezer, deposit to MES store yard complete all as specified and as directed by Engineer in charge.
S&F refrigerator, electric driven (single phase), capacity 320 Litres.BEE 5 star rated including dismantling of old unserviceable refrigerator, deposit to MES store yard complete all as specified and as directed by Enngineer-in-charge.
S&F refrigerator, electric driven (single phase), capacity 195 Litres.BEE 5 star rated including dismantling of old unserviceable refrigerator, deposit to MES store yard complete all as specified and as directed by Enngineer-in-charge.
S&F in repair of thermostat with knob in Refrigerator & water cooler of any capacity of any make and making suitable fixing arrangement as required of existing place complete all as specified and as directed by Engineer in charge
(a) Refrigerator 165 to 320 ltr.
(b) Water Cooler 40/80 ltr & 60/120 ltr
S&F in repair of relay kit with overload protection and load management setting suitable for existing model of Refrigerator & water cooler of any capacity of any make complete all as specified and as directed by Engineer in charge
(a) Refrigerator 165 to 195 ltr.
(b) Water Cooler 40/80 ltr.
M&L for complete tinkering the corroded sheet metal parts, side panel, door, with existing gauge M.S. Sheet and renewal of the bottom base plate, mounting lets, fan motor base plate, and condenser cover etc., with existing size gauge G.I. sheet, with required Angle Iron, Nut & Bolts all as per the existing size and shape including cutting, bending, welding and completing fixing all other components, complete scraping with old paint, prepare the surface, painting 2 coat of enamel paint over a coat of primer and complete cleaning the water tank and shifting to the location and testing for any capacity of water coolers all as specified as directed by Engineer-in-Charge.
M&L for painting the water cooler including scraping out the old paint prepare the surface, painting 2 coat of enamel paint over a coat of primer, the work including necessary putty, metal paste etc., and disconnecting from the position and refixing after painting for any capacity of the water coolers complete all as specified and as directed
Removing the old paint of the body of refrigerator of any capacity and making the body dent proof and preparing the surface and Painting the refrigerator with 2 coats of synthetic enameled paint of superior quality to match with existing paint with spray painting complete all as specified and directed by Engineer in charge
M&L for taking down the damaged thermal insulation of the water cooler, and renew the thermal insulation as per the existing thickness and assembling the body with necessary sheet metal screws etc., for any capacity water coolers complete all as specified and as directed by Engineer in charge
S&F in repair Bimetallic timer suitable for existing model of Refrigerator of capacity 165 to 320 liters of any make complete all as specified and as directed by Engineer in charge
S&F in repair Heater suitable for existing model of Refrigerator of capacity 165 to 320 liters of any make of existing place complete all as specified and as directed by Engineer in charge
Taking down of unserviceable led bulb of Refrigerator of capacity 165 to 320 liters of any make and supply and fixing of new one compatible for existing model of Refrigerator of capacity 165 to 320 liters of any make complete all as specified and as directed by Engineer in charge
M&L in repair of Mild Steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe 410-W (Gde-E-250) quality-A complete all as specified and as directed by Engineer in charge
S&F in repair of Chromium plated brass push cock, 15 mm dia water cooler of any capacity and making suitable fixing arrangement as required complete all as specified and as directed by Engineer in charge
RPG AND COMPANY (BID ID -3298269)
M/s Gurunath Construction (BID ID -3298321)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .