Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹22.6 LAccepted-AOC | L-1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L-2₹25.4 L+₹1.6 L (6.87%)Rejected-Finance | L-2 | Rejected-Finance Other than Lowest | |
| 3 | L-3₹26.7 L+₹2.9 L (12.3%)Rejected-Finance | L-3 | Rejected-Finance Other than Lowest | |
| 4 | L-4₹27.2 L+₹3.4 L (14.5%)Rejected-Finance | L-4 | Rejected-Finance Other than Lowest | |
| 5 | L-5₹28.4 L+₹4.6 L (19.4%)Rejected-Finance | L-5 | Rejected-Finance Other than Lowest |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
28 Sept 2024, 6:00 pmClosed
GE (AF) Srinagar
Garrison Engineer (AF) Air Force Station Srinagar 190 007
CA NO. GE (AF)/SGR-46/2024-25 CERTAIN MAINT B/R AND E/M WORKS AT 727 AREA, LALGAON AREA AND OTHER AREA UNDER GE (AF) SRINAGAR.
2024_MES_670979_1
GE (AF)/SGR-46/2024-25
Open Tender
Miscellaneous Works
Item Rate
180 days
AOR OF GE (AF) Srinagar
Please refer NIT and Tender Documents
9 documents required · 9 mandatory
₹50
GE (AF) Srinagar
₹80,000
Yes
19 Oct 2024
3 Sept 2024
30 Sept 2024
3 Sept 2024
28 Sept 2024
17 Sept 2024
Amount
B/R Work
Taking down cement or cement lime plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed.
M&L for 15mm thick rendering in cement and sand mortar 1:6 on other than fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth without using extra cement, complete all as specified and directed.
M&L for 15mm trhick rendering in cement and sand mortar 1:4 on fair faces of brick work or cement concrete surfaces including finishing the surface even and smooth using integral water proofing compound, complete all as specified and directed.
M&L for 5mm thick rendering on brick or concrete surface of ceiling finished fair & even in CM 1:3, complete all as specified and directed.
Preparation of newly plastered surfaces of ceiling and applying two coats of distemper oil emulsion including preparatory coat to distempering, complete all as specified and directed.
Preparation of newly plastered surfaces of wall and applying two coats of distemper oil emulsion, including preparatory coat to distempering, complete all as specified and directed.
Preparing of new surface of wall and applying two coats of cement based paint over one coat of primer, complete all as specified and directed.
Demolition of brickwork built in cement mortar including all quoins, arches, pillars etc including removal of rubbish out of defence land, complete all as specified and directed.
M&L for Brick work with sub class ‘B’ bricks, using old size bricks, straight or curved on plan exc 6 m mean radius built in cement mortar 1:6, complete all as specified and directed.
Preparation of old plastered/unplastered old decorated surfaces of walls, pillars, cornices by brooming down or steel brushing, scraping down smoke roots. moulds, moss and efflorescence salts, trading oil greasy spots etc. and applying one coat of cement base paint, complete all as specified and directed.
Complete removal of existing treatment from brick walls or concrete surfaces including scraping down smoke soots, moulds, moss and trading oil and greasy spots etc including cornices, pilasters etc (Plastered or un plastered surfaces) and applying two coats of cement based paint over a coat of cement primer including preparation of surfaces on walls, complete all as specified and directed.
Prepartion of old decorated plastered or unplastered surfaces of wall including filling of holes, cracks and undulating surface with cement wall care putty making surface even and smooth and applying one coat of distemper oil emulsion paint (OBD), complete all as specified and directed.
Complete removal of existing treatment of walls and applying two coats of distemper oil emulsion (OBD) over a thin layer of putty including prepartion of old plastered surface of wall, complete all as specified and directed.
Preparation of old surfaces of ceiling including scraping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc including cornices, pilasters etc (plastered or unplastered surfaces) and applying two coats of white (lime) wash, complete all as specified and directed.
Preparation of old painted steel and iron surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Preparation of old painted wood and wood based surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) n exc. 1.5 sqm and credited to the contractor, complete all as specified and directed. Note: The damaged portion of the tiles/rendering shall be made good with the same material to match with the adjacent surface without any extra cost.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) exc. 1.5 sqm but n exc 4 Sqm each and credited to the contractor, complete all as specified and directed. Note: The damaged portion of the tiles/rendering shall be made good with the same material to match with the adjacent surface without any extra cost.
Supply and fixing aluminium powder coated aluminium window having three track with aluminium section 92 mm X 31.75 mm (Weight bottom section 1.070 kg/m, top section 0.933 kg/m, shutter section 40 mm X 18 mm (weight of handle section 0.417 kg/m) interlock 0.547 kg/m mounted on bearing to slide on tracks plain anodized in approved shade (min thickness of powder coating 50 micron) including fixing of 5mm thick sun/heat reflacted glass and wire mesh, PVC track gasket, EPDM rubber gasket on glass of weather tightening along with locks, handle including sealing gap with marble surfaces with silicon sealants making it water proof in all manner etc. (all ittems mentioned in the description and fitting and fixtures are deemed to be included in the quoted rate), complete all as specified and directed.
S&F 35mm thick second class hardwood, Factory made, Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) supplied and fitted to chowkats, complete all as specified and directed.
S&F 35mm thick second class hardwood, Factory made, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, complete all as specified and directed.
Preparation of new wooden surfaces exceeding 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specification & drawing, complete all as specified and directed.
S&F Factory made solid panel pace door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specification & drawing, complete all as specified and directed.
S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts, complete all as specified and directed.
S&F for 150 mm long aluminium anodised, handle of extruded section fabricated type anodised and fixed, complete all as specified and directed.
S&F 150mm size aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F for 125 mm long aluminium anodised, handle of extruded section fabricated type anodised and fixed, complete all as specified and directed.
S&F 125mm size aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
S&F 100mm long butt hinges, medium weight, cold rolled mild steel, complete all as specified and directed..
S&F 140mm length floor door stopper of aluminium alloy body and tounge, anodised with hard drawn steel spring fixed in floor, complete all as specified and as directed.
S&F in repairs 300 mm long mild steel ordinary rat tail rod pattern, door spring including roller and roller plate, complete all as specified and directed.
S&F mild steel wire cloth of 0.56 mm nominal dia of wire and averaging of width of aperture 1.40mm, fixed with stainless steel wire staples, complete all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed.
S&F Roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-290 Gde-E-165, complete all as specified and as directed.
S&F rolled mild steel rolled section as in main and cross beams, hip and jack rafters, purlin where connected to common rafters and running rails and guides for for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe 410-W, Gde-E-250, quality A, complete all as specified and as directed.
S&F Framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of water tanks and similar work conforming to Fe.290.Gde-E-165, complete all as specified and as directed.
Preparation of newly steel surfaces of any description, not exc 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed.
S&F in repairs stainless steel wire cloth 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with stainless steel wire staples, complete all as specified and directed.
Dismantling of Plain corrugated or asbestos steel sheeting any gauge, thickness, including Nainital or similar pattern roof coverings including ridges, hips, valleys and flashings etc, complete all as specified and directed.
S&F 0.63mm thick Galvanised, corrugated mild steel sheeting with two corrugations side lap, with L-type or J-type or cranked hook bolts, in roofs, walls etc. with grade of zinc coating, complete all as specified and directed.
All as per Ser item No. 41.00 here in above but except sheet.
S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating, complete all as specified and directed.
M&L for tightening bolts and closing bolt holes, etc.to rectify the leakage/ seepage, in old roof of corrugated steel sheets by sealing with one bitumen and one curved GI washer on either side and 6mm G.I. bolts and nuts if required, all set in stiff white lead, complete all as specified and directed.
Preparation of new zinc (or galvanised) steel and iron roof surfaces of any description over 10 cm width or girth to receive painting, by coating with mordant solution including washing and cleaning, etc and applying two coats of synthetic enamel paint over one coat red oxide primer in camouflaging CCD pattern as approved, complete all as specified and directed.
S&F in position suspended false celling system using E Grid suspended celling Grid system of M/S Everest industries Ltd or India Gypsum. The size of Grid shall be 600X600mm with GI frame work, main runner 39X24mm, cross tee 29X24mm and wall angle 22.2X22.2mm using 4mm thick High Pressure Stream cured non primered classic/designer variant E-Board ISI Marked IS No 14862-2000. Fibre cement E Board to be placed in the gird of E Grid suspended ceiling grid system duly suspended by 4mm dia GI bar hangers from the pulins of the roof with butter fly clips including dismantling the existing ceiling board of any description fixed in any position with nails, complete all as specified and directed.
S&F 15mm bore steel warer tubes, 'medium grade', galvanised, with all fitting (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed complete to walls, ceilings or laid in floors including taking up or down old steel water tubing, complete all as specified and directed.
S&F 20mm bore steel warer tubes, 'medium grade', galvanised, with all fitting (such as bends, elbows, tees, short pieces, connectors, back nuts, diminishing pieces, caps, plugs, unions etc) and fixed complete to walls, ceilings or laid in floors including taking up or down old steel water tubing, complete all as specified and directed.
M&L for Lagging to pipes 15mm bore used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25gauge 20mm mesh including applying with brushing neat cement slurry with 3 kg of cement per Sqm complete, complete all as specified and directed.
M&L for Lagging to pipes 20mm bore used in external water supply or plumbing all around with 50mm thick bonded mineral wool pre-formed ‘SNAP ON’ pipe sections of density 144 Kg /Cum conforming to IS 9842 provided with chicken mesh wire netting 25gauge 20mm mesh including applying with brushing neat cement slurry with 3 kg of cement per Sqm complete, complete all as specified and directed.
S&F 500 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling water tanks and removing from site including 20 mm Ball brass valves, high pressure, with polythene float and flynut, complete all as specified and as directed.
S&F 1000 litres capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling water tanks and removing from site including 20 mm Ball brass valves, high pressure, with polythene float and flynut, complete all as specified and as directed.
S&F in repairs 15mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed.
S&F in repairs 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed.
S&F in repairs 15mm bore stop cock/angle cock, fancy type, with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends, complete all as specified and directed.
S&F in repairs 15mm bore two way stop cock/angle cock, fancy type, with long shank cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends, complete all as specified and directed.
S&F in repairs 15mm bore bib tap, two way, cast copper alloy with capstan head, Fancy type, chromium plated, with long body shank, screwed down with high pressure screwed for iron pipe & fixed, complete all as specified and directed.
S&F in repairs 15mm bore bib tap, cast copper alloy with capstan head, Fancy type, chromium plated, with long body shank, screwed down with high pressure screwed for iron pipe & fixed, complete all as specified and directed.
Dismantling floor, hearth wall tiling /stone slab/brick tiling /interlocking tiling/Pre-polished tiles etc including cement mortar bedding (but not backing)/ cement plaster including rubbish off the premises, complete all as specified and directed.
M&L for 10mm thick vitrified parking tiles heavy duty exterior grade texured finished of size 300X300 mm as in stair case, roof tarres, path over and including 15 mm thick screed bed in CM 1:4, complete all as specified and directed.
M&L for Non skid, ceramic tiles, area of each tile of size 300x300 x7-8 mm thick, as in floors, set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles bedded over and including 15mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
M&L for Non skid, ceramic tiles, area of each tile of size 400x400 x7 mm thick, as in floors, set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles bedded over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
M&L for Glazed ceramic tile 450 x 300 x 7mm thick (coloured) on vertical surfaces such as wall, dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 10 mm thick screed bed/bedding in CM 1:4, complete all as specified and directed.
M&L for vitrified tiles of size 600x600 x8 mm thick, as in floors, set and jointed in neat cement slurry and pointed in white cement with pigment to match the colour of tiles bedded over and including 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed.
Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed.
M&L for 75 mm thick PCC, 1:3:6, type C-1(using 20mm graded crushed stone aggregate) as in plinth protection laid in bays n. exc. 2 sqm each, finishing the surface of concrete topping even & fair, without using extra cement filling the joints with mastic filling comprising of one part of heated bitumen 85/25 or 95/10 grade and 3 parts of sand (all by weight), complete all as specified and directed.
M&L for 20-25mm thick machine cut kota stone slab flooring, jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing & polishing, over and including 20mm thick screed bed or bedding layer in CM 1:6, complete all as specified and directed.
M&L for grinding and polishing of existing of Kota stone/tarrazo tiles flooring polished upto mirror finish, complete all as specified and directed.
M&L for 75 mm thick cement concrete, 1:4:8, type D-2, (using 40mm graded crushed stone aggregate) as in sub base, complete all as spciified and directed.
M&L for 25mm thick cement concrete, 1:2:4, type B-0 (using 12.5 mm graded crushed stone aggregate) as in sub base of floor finish even and rough to receive further floor finishes (tile/kota stone/ marble ), complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-40 Grade with grey cement and pigment over and including 40 mm thick compacted bed of fine sand, complete all as specified and directed.
M&L for glossy finished rubber moulded machine pressed rubber moulded chequered tiles of any pattern/design of size 300mm x 300mm x 25mm thick laid over and including 15mm thick screed bed in CM 1:6 in floors paths etc, complete all as spciified and directed.
M&L for providing cement concrete, 1:2:4, (Nominal mix), Type B-1 (using 20mm graded crushed stone aggregate) as edges of interlocking tiles/chequired tiles, roof kerbs or mud stops, rounded or chamfered on edges, complete all as specified and directed.
S&F in repairs WC squatting pan “Orissa Pattern” of size 580 x 440mm, white with integral foot rest (excluding flushing cistern & flush pipe) including connection to trap and to flush pipes etc and lime concrete bedding complete all as specified in SSR and including trap set, complete all as specified and directed.
S&F in repairs 10 ltr capacity PVC flushing cistern valve less syphonic action type low level with and including ball valve float & handle, waste pipe & brackets complete set, complete all as specified and directed.
S&F in repairs vitreous china wash basin white flat back, size 550x400 mm, with & including 32mm dia PVC waste pipe and waste coupling with & including angle iron brackets of suitable size & length or erecting stand etc., complete all as specified and directed.
S&F in repairs Stainless steel soap dish fixed to wall with plug and screw, complete all as specified and directed.
S&F in repairs 32mm size PVC waste pipe flexible for WHB, complete all as specified and directed.
S&F in repairs Vitreous china urinal, half stall type including all fittings with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in CM 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement, complete all as specified and as directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm, complete all as specified and directed.
S&F in repairs CP Jet Spray of Standard size for EWC alongwith CP connection pipe and all fittings as fixed, complete all as specified and directed.
S&F in repairs CP Health faucet fixed with spring action and lever along with health faucet long pvc/cp chain 1.2 m for supply of water fitted in the existing water connection in the toilets, complete all as specified and directed.
S&F in repairs Single piece floor mounted vitreous chaina white EWC with double symphonic low level cistern with complete fittings, coloured seat cover of 1st quality as approved by the Engr-in-charge, complete all as specified and directed.
E/M Work
Taking down point wiring with aluminum/copper conductor cable of light point fan & socket light & power complete including light fittings any type switches, sockets, ceiling rose, switch boards, bell/buzzer, bell push, tube light fitting, regulator DB boxes with all fixtures service wire etc, and making good to the disturbed surfaces of walls/ floor etc to match with existing surfaces including white washing/colour washing/ distemper to match with existing wall/floor/ceiling finishes, complete all as specified and directed.
M&L point wiring 1100 volt grade single coreFRLS/ FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed type including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel sunken box thickness not less than 1.8 mm on wall for mounting of piano/flush type switches, switch sockets, fan regulator etc any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly, complete all as specified and directed.
All as per Ser item No 87.00 here in above but One light point controlled by one switch.
All as per Ser item No 87.00 here in above but one ceiling /exhaust fan point controlled by one switch and regulator.
All as per Ser item No 87.00 here in above but one 3 pin 5 Amp socket out point on the same board with other switches.
All as per Ser item No 87.00 here in above but one 3 pin 5 Amps socket outlet point on independent board.
All as per Ser item No 87.00 here in above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 Amps power point.
M&L point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit / casing caping on surface of wall not less than 20mm dia/25mm width with IS 9537 (Part-III) 1983 marked medium grade on surface of wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel sunken box thickness not less than 1.8 mm on wall for mounting of piano/flush type switches, switch sockets, fan regulator etc any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets,ceiling roses and holders shall be connected to common earth dolly.
All as per Ser item No 93.00 her in above but one lihgt point controlled by one switch.
All as per Ser item No 93.00 her in above but one ceiling /exhaust fan point controlled by one switch and regulator.
All as per Ser item No 93.00 her in above but one 3 pin 5 Amp socket out point on the same board with other switches.
All as per Ser item No 93.00 her in above but one 3 pin 5 Amps socket outlet point on independent board.
All as per Ser item No 93.00 her in above but wiring with 2.5 sqmm multi stranded cable and earth wire with copper conductor of size 2.5 sqmm for 15 amps power point.
All as per Ser item No 93.00 her in above but one bell/buzzer point controlled by one bell push.
S&F in repairs modular one way switch 6 Amp 240 volts suitable for one module, complete all as specified and directed.
S&F in repairs modular one way switch 16 Amp 240 volts suitable for one module, complete all as specified and directed.
S&F in repairs modular 6 Amp socket suitable for two module 240 volts, complete all as specified and directed.
S&F in repairs modular 16 Amp socket suitable for two module 240 volts, complete all as specified and directed.
S&F in repairs modular step type fan regulator suitable for 120 watt 250 volts, complete all as specified and directed.
S&F in repairs piano type one way switch 6 Amp 240 volts suitable, complete all as specified and directed.
S&F in repairs piano type one way switch 16 Amp 240 volts suitable, complete all as specified and directed.
S&F in repairs piano type 6 Amp socket suitable for 240 volts, complete all as specified and directed.
S&F in repairs piano type 16 Amp socket suitable for 240 volts, complete all as specified and directed.
S&F in repairs piano type step type fan regulator suitable for 120 watt 250 volts, complete all as specified and directed.
S&F in repairs lamp holder/batten holder Polycorbonate type with back plate suitable for batten fitting including supply & fixing of 10 watt retrofit lamp, complete all as specified and directed.
S&F in repairs ceiling rose with three terminal as per relevant IS, complete all as specified and directed.
S&F 10 watt LED bulb, complete all as specified and directed.
S&F in repairs Energy efficient surface mounted 2'X2' grid Ceiling LED fitting 36/40 W rated voltage 240 V, 50Hz combination with profiled and flat diffuse, complete all as specified and directed.
S&F in repairs LED baton fitting 2' length including drivers having energy consumption, 10/11W (White/warm white), 230 V ,50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed.
S&F in repairs LED baton fitting 4' length including drivers having energy consumption, 18/20W (White/warm white), 230 V ,50Hz, 6500K, not less than 800 lumen prewired, complete all as specified and directed.
S&F in repairs light fitting 9W bulk head luminaries with lamp holders etc complete with all accessories and including connecting up with twin core twisted flexible cable suitable size of 230V, 50HZ, complete all as specified and directed.
S&F in repairs fittings with surface mount LED down lighters 12 W including driver with rated voltage 240 V, 50 Hz, complete all as specified and directed.
S&F in repairs building security light LED 25 W with Lumen O/P 1800 with driver with rated voltage 240 V, 50Hz,including mounting GI (made out of 25 mm dia light grade pipe 0.8 m bent two shape including FI clamps nut bolts etc., complete all as specified and directed.
S&F in repairs call bell ding dong type 230 Volts 50 Hz, complete all as specified and directed.
S&F in repairs sheet metal enclosure epoxy powder coated or polysterene insulated material double door type, vertical triple pole & neutral (VTPN) with MCCB 100 amps ICs=ICu,for 415 volts, 4 way with 200 Amp rated bus bar flush /surface mounting double door, complete all as specified and directed.
S&F in repairs epoxy powder coated or polysterene insulated material sheet metal enclosure factory made ( double door), 8 way SPN suitable for MCB 240 Volts with 200 Amps rated bus bar neutral and earthing link bar flushed/surface mounted suit, complete all as specified andas directed.
S&F in repairs epoxy powder coated or polysterene insulated material sheet metal enclosure factory made ( double door), 12 way SPN suitable for MCB 240 Volts with 200 Amps rated bus bar neutral and earthing link bar flushed/surface mounted suit, complete all as specified and directed.
S&F in repairs MCB triple pole and neutral ISI marked, C series, working on 415 volts 50HZ AC supply for incoming and outgoing controlling system capacity 63 Amps, 10 KA breaking capacity, complete all as specified and directed.
S&F in repairs MCCB three pole ISI marked working on 415 Volts 50Hz supply for incoming and outgoing controlling system of capacity 150 Amps, 16 KA breaking capacity, complete all as specified and directed.
S&F MCB single pole 240 volt 6 to 32 Amps, 10 KA breaking capacity, 'C' series, complete all as specified and directed.
S&F in repairs MCB single pole and neutral, 40 Amp, 240 volt, 10 KA breaking capacity, 'C' series, complete all as specified and directed.
S&F in repairs MCB single pole and neutral 63 Amp, 240 volt amps 10 KA breaking capacity, 'C' series, complete all as specified and directed.
S&F in repairs metal clad plug & socket board SP&N enclosure with 2 pole and earth metal plug and socket complete 20 Amp MCB SP, C curve, complete all as specified and directed.
S&F in repairs metal clad plug & socket board triple pole and neutral enclosure with 3 pin and earth plugs and socket complete with one triple pole MCB 32 Amps, 415 Volts, C type, complete all as specified and directed.
S&F in repairs switch socket combination 16 Amps 5 in-1 pin type, comlete all as specified and directed.
S&F in repairs switch socket combination 6 Amps 3 in-1 pin type, comlete all as specified and directed.
M&L for submain wiring with three run of single core multistranded copper conductor cable, of size 6.0 sqmm PVC insulated, unsheathed conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor thed fire retardant low smoke drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 4.0 sqmm, PVC insulated, unsheathed fire retardant low smoke earth wire, fixed on wall/ceiling, including taking down old, complete all as specified and directed. Note:- 3 Runs of main cable and one run earth wire with conduit will be measured as one unit for payment purpose.
M&L for submain wiring with two run of single core multistranded copper conductor cable, of size 4.0 sqmm PVC insulated, unshea conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor thed fire retardant low smoke drawn through and including heavy duty rigid PVC conduit not less than 20 mm dia with all necessary fitting and including one run of single core multistranded copper conductor cable, of size 2.50 sqmm, PVC insulated, unsheathed fire retardant low smoke earth wire, fixed on wall/ceiling, including taking down old, complete all as specified and directed. Note:- 2 Runs of main cable and one run earth wire with conduit will be measured as one unit for payment purpose.
Renewal of Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 TYPE B-1 (.c) Pre cast RCC cover with suitable handle 40mm thick in PCC 1:2:4 reinforced with welded steel wire fabric weighting not less than 1.87 Kg/sqmm (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion, complete all as specified and directed.
Deduction to be made from BOQ for Schedule 'A' Part-IV (Credit Schedule from dismentling/taking down items) worth Rs 1,22,317.00 during AOC. Note :- Tenderers shall not quote for this Schedule.
M/S GULAM AHMAD ABDUL SAMAD (BID ID -3100952)
M/S TARIQ AHMAD SHEIKH (BID ID -3119474)
M/S ZAHOOR ENTERPRISES (BID ID -3118340)
M/S LATIF AHMED MIR (BID ID -3105894)
M/S GHULAM MOHAMMAD AND CO. (BID ID -3107680)
M/S KHAN ENTERPRISES (BID ID -3118319)
M/S Thakur & Sons (BID ID -3119610)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .