Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC AT DANGALPARA SURJ BIRBHUM PIN 731191 | SURI | BIRBHUM | WEST BENGAL | 731191 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹9.3 L+₹6,593 (0.72%)Rejected-AOC 334 SCHOOL DANGA BANKURA BANKURA WEST BENGAL 722101 | BANKURA | BANKURA | WEST BENGAL | 722101 | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹9.3 L+₹14,687 (1.60%)Rejected-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L3 | Rejected-Finance Being L3 Bidder |
Tender Value
Refer Docs
EMD Value
₹18,578
Closing Date
20 Nov 2024, 1:00 pmClosed
E.E P.W.DTE BIRBHUM ELECTRICAL DIVISION
Ofc of The EXECUTIVE ENGINEER P.W.DTE. Birbhum Electrical Division P.O. Suri,Dist Birbhum, Pin 731101
Emergent Supply and repair of existing Fire Detection System in Main Building and Old OPD Building of Rampurhat Govt. Medical College and Hospital under Rampurhat Electrical Sub-Division, PWD.
2024_WBPWD_768755_1
BIRED/125/e-NIQ (1st call) of 2024-2025
Open Tender
ELECTRICAL WORKS ORG
Item Rate
15 days
RAMPURHAT
Please refer Tender documents.
4 documents required · 4 mandatory
₹18,578
OFFICE OF The EXECUTIVE ENGINEER P.W.DTE. Birbhum
25 Mar 2025
12 Nov 2024
22 Nov 2024
12 Nov 2024
20 Nov 2024
14 Nov 2024
14 Nov 2024
Amount
Part - A : For Main Building Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved ) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case one independent fault isolator module for every group of addressable devices has to be provided ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Notifer/Honeywell/Seimens) With 3 Yrs Warranty [For Main Building]
Supplying, installation, testing and commissioning of Addressable Heat Detector (Fixed temperature cum rate of rise) with twist lockable removal base, built - in fault isolator, drift compensation feature etc including connections as per specifications complete as reqd and having IP as per recommended standard(Note : Detectors without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group of addressable devices ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost)..(Approved Make: Notifer/Honeywell/Seimens) With 3 Yrs Warranty [For Main Building]
Supply, Installation,Testing & Commisioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make: Notifer/Honeywell/Seimens) With 3 Yrs Warranty Note : Hooter must be Addressable by itself or by using control module. If Loop Power Hooter is not used, separate wiring from control Panel upto the the hooter will be in contractor scope without any extra cost.[For Main Building]
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / FM / ULC approved ) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Notifer/Honeywell/Seimens) With 3 Yrs Warranty [For Main Building]
Supply, Installation, Testing & Commissioning of Power supply 230 V AC to 24V DC with all other accessories. (Make: Reputed) With 3 Yrs Warranty [For Main Building]
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) with existing PVC rigid conduit pipe(Make: Precision /AKG/ATUL /VIP/ Universal /BEC/Polycab) on the surface of the wall. [For Main Building]
Testing & Commisioning of existing Microprocessor based Intelligent, addressable expandable and fully networkable Fire Alarm Control Panel.
Part - B : For Old OPD Building Supply, Installation,Testing & Commisioning of Analog Addressable Intelligent multisensor detector ( VDS / UL / FM / ULC approved ) with inbuilt optical smoke sensors as well as additional heat detector sensor with decentralise intelligence, soft addressable Photothermal type with inbuilt fault isolator as per NFPA style 7 wiring complete with base having IP as per recommended standard.(Note : Detectors without built-in fault isolator is also acceptable but in such case one independent fault isolator module for every group of addressable devices has to be provided ( Numbers of addressable devices in a group will be as per latest recommended standards ) without any additional cost). (Approved Make: Seimens/Notifier/Honeywell ) With 3 Yrs Warranty [ For Old OPD Building ]
Supply, Installation, Testing & Commissioning of Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd)complete with inbuilt isolator & IP65 base and ( VDS / UL /ERTL/ LPCB / FM approved) approved. (Approved Make: Seimens/Notifier/Honeywell ) With 3 Yrs Warranty Note : Hooter must be Addressable by itself or by using control module. If Loop Power Hooter is not used, separate wiring from control Panel upto the the hooter will be in contractor scope without any extra cost. [ For Old OPD Building ]
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS / UL / FM / ULC approved ) soft addressable type with in built fault isolator as per NFPA style 7 wiring complete as required. (Approved Make: Seimens/Notifier/Honeywell ) With 3 Yrs Warranty [ For Old OPD Building ]
Supply, Installation, Testing & Commissioning of Control Modules (VDS / UL /ERTL/ LPCB / FM approved) for notification appliances (horns, Strobes, speaker, hooter etc) etc complete as required.(Approved Make: Seimens/Notifier/Honeywell ) With 3 Yrs Warranty [ For Old OPD Building ]
Supply, Installation, Testing & Commissioning of Addressable transponder/ Monitor Modules ( VDS / UL /ERTL/ LPCB / FM approved ) for monitoring flow switches/Fire exit doors / AHU / Lift etc complete as required. (Approved Make: Seimens/Notifier/Honeywell ) With 3 Yrs Warranty [ For Old OPD Building ]
Supply, Installation, Testing & Commissioning of Addressable Relay Modules (VDS / UL /ERTL/ LPCB / FM approved) for switching / integration of Lift / AHU etc complete as required. (Approved Make: Seimens/Notifier/Honeywell ) With 3 Yrs Warranty [ For Old OPD Building ]
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/RR Kable/Polycab ) with 20 mm NB PVC rigid conduit pipe(Make: Precision /AKG/ATUL /VIP/ Universal /BEC/Polycab) on the surface of the wall.
Supply, Installation, Testing & Commissioning of Power supply 230 V AC to 24V DC with all other accessories. (Make: Reputed)
Supply, Installation, Testing & Commisioning of Microprocessor based Intelligent, addressable expandable and fully networkable Fire Alarm Control Panel ( VDS / UL /ERTL, LPCB & FM approved ) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding 80% of the full capacity of detectors and devices taken together, conplying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display.The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches whenever any alarm is triggered.The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. With 3 Yrs Warranty
The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, in built Surge protection facility, integral SMF lead acid batteries with sealed cells of 24 V capable of running for 24 hours normal working and then be capable of operating the system for 30 minutes during Emergency condition, with integral battery charger complete in all respect as required.
The FACP shall be capable of being networked ( future expansion ) with other similar FACP located at different part of the premises through single RS 485 bus.The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface.The system must be preloaded with licenced software. (Approved Make: Seimens ) [ For Old OPD Building ]
NOTE : 1. The Fire Alarm system shall comply with latest requirements of -- 2. National Fire Protection Association (NFPA) Standards. 1. IS 2189 3. NFPA 70 National Electric Code 4. NFPA 72 National Fire Alarm & Signaling Code 5. Local Statutory Regulations 6. Manufacturer Recommendation.
TESTS:1.The system shall be tested and commissioned by a qualified competent,trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technically supervise and participate during all of the adjustments and tests for the system. 2. Before energizing the cables and wires, check for correct connections and test for short circuits, ground faults, continuity, and insulation and other tests as per above standards must be done. 3. The Commissioning Manuals, Tools , Dongles, USb Token, Software, or whatever is required for the Commissioning of the FACP, in whatever name it called must be handed over to the EIC, along with the passwords of the panel.
Terms and Condition The Agency must procure the materials from the Manufacturer / OEM or from their authorised sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them.
Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/submission of bill.
If any refurbished material is supplied and installed, penal action will be taken as per existing rules
N.B: i) Payment will be made after availability of fund from concern Department. ii) Payment will be made as per P.W.D norms.
TAPAN KUMAR SARKAR (BID ID -5762315)
Swarnendu Sarkar (BID ID -5762302)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .