REPAIRS AND MAINTENANCE OF CASSETTE SPLIT TYPE AIR CONDITIONERS AND CERTAIN ALLIED REPAIRS AT ADE DEBEL UNDER GE I R AND D EAST BANGALORE
2026_MES_796544_1
8786/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE I R AND D EAST BANGALORE
CLASS D CATEGORY c(i)
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D EAST BANGALORE
₹96,000
Yes
6 Nov 2026
6 Nov 2026
27 Nov 2026
6 Nov 2026
25 Nov 2026
20 Nov 2026
6 Nov 2026 - 19 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down outdoor and indoor unit of split ACs of upto 3 Ton capacities by disconnecting all electrical connections, refrigerant tubings, foundation bolts, etc. carefully and keep the same in safe custody for re-use complete all as specified and as directed. | 20 | EACH JOB | - | - |
| 2 | Material and labour for re-installing of removed split AC at other location and testing of outdoor and indoor unit of split AC up to 3 Ton capacities obtained from item No 01 above in position including electric connection, refrigerant tubings, foundation bolts, etc complete all as specified and as directed.
NOTE :- Charging of Refrigerant Gas and copper for suction and liquid line, copper cable will be measured and paid separately under relevant item of schedule. | 20 | EACH JOB | - | - |
| 3 | Supply, install, testing and commissioning in replacement of three phase controlling unit to control the switching operation of Air conditioners / Exhaust Fan in an alternative manner with PLC module. Rated current (In) of system is 63A at rated operational Voltage (Ue) of 415V AC ,with rated insulation voltage upto 500V AC voltage.Control unit shall have SCPD device in series with control devices.Control Unit protection and suitable for wall mounted installations.Enclosure of control unit shall have earthing bolts for safety purpose and shall have detachable gland plates with for entry of cables, with pad type locking facility complete all as specified and as directed. | 1 | EACH | - | - |
| 4 | Supply and fix in replacement of voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170 volts to 250 volts with out put voltage stablized at 230 volts with accuracy of +/- 2.5% and of capacity upto 5 KVA complete all as specified and as directed. | 15 | EACH | - | - |
| 5 | Material and labour for MS stand duly painted suitable for fixing upto 3 TR AC outdoor unit and fixed complete with using anchor fasterns complete all as specified and as directed. | 20 | EACH JOB | - | - |
| 6 | Making opening / drilling of size 65 mm dia, using heavy duty stone driller / cutter machine in the stone masanory wall for installing split type air conditioners and for passing suction and discharge refrigerant pipe lines, drain pipe, cable etc and making good the disturbed surface complete all as specified and as directed. | 20 | EACH JOB | - | - |
| 7 | Supply and laying of copper pipe of size 5/8" & 1/4" with nitrile rubber tubular insulation, using necessary supports and fastners complete all as specified and as directed. | 120 | RUNNING METRE | - | - |
| 8 | Supply and laying of copper pipe of size 5/8" & 3/8" with nitrile rubber tubular insulation, using necessary supports and fastners complete all as specified and as directed. | 120 | RUNNING METRE | - | - |
| 9 | Supply and laying of extra copper pipe of size 1/2" and 1/4"with nitrile rubber tubular insulation, necessary supports and fastners complete all as specified and as directed. | 120 | RUNNING METRE | - | - |
| 10 | Material and labour for complete servicing after pumping down Indoor / outdoor units of split AC complete by cleaning condenser/ Evaporator coil with air blower / pressure pump wet servicing of condenser coil unit etc, replacement of sheet metal screws wherever necessary applying oil in fan motor bushes checking and rectifying the wiring defects, proper setting of thermostat and other electrical / Refrigerant controls, cleaning the air filter, reconnecting up all removed connections and testing after gas charging if required complete all as specified and as directed for Split type Air Conditioner up to 2 TR all as directed. | 410 | EACH JOB | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
BOQ_894932.xls
BOQ • 1.66 MB
8786Tender.pdf
Tender Documents • 0.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .