Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.3 CrAccepted-AOC | ₹10.3 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹10.4 CrRejected-Finance | ₹10.4 Cr | L2 | Rejected-Finance REJECTED SINCE NOT L1 |
| 3 | L3₹11.0 CrRejected-Finance STREET NO 11 SECTOR NO 04 TILAK NAGAR SAGAR ROAD BIKANER RAJASTHAN 334001 | BIKANER | RAJASTHAN | 334001 | ₹11.0 Cr | L3 | Rejected-Finance REJECTED SINCE NOT L1 |
| 4 | L4₹11.4 CrRejected-Finance | ₹11.4 Cr | L4 | Rejected-Finance REJECTED SINCE NOT L1 |
| 5 | L5₹11.6 CrRejected-Finance NO 15 B 2ND FLOOR 4TH CROSS T ASHWATHNARAYANA ROAD THIMMAIAH NAGARA YELAHANKA BANGALORE 560 064 | BANGALORE | BANGALORE | KARNATAKA | 560064 | ₹11.6 Cr | L5 | Rejected-Finance REJECTED SINCE NOT L1 |
Tender Value
₹10.5 Cr
EMD Value
₹8.5 L
Closing Date
5 Jun 2020, 6:00 pmClosed
CE AF ALLAHABAD
HQ CE AF ALLAHABAD
GENERATION OF SOLAR ENERGY OF CAPACITY OF 1.5 MW AT AF STN AGRA
2020_MES_330819_1
958368/E8
Open Tender
Civil Works
365 days
GE AF ADM AREA KHERIA AGRA
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹3,000
Yes
GE AF Adm Area Agra
₹8.5 L
Yes
29 Jun 2020
3 Mar 2020
11 Jun 2020
3 Mar 2020
5 Jun 2020
25 May 2020
5 Mar 2020 - 13 Mar 2020
Amount
SCHEDULE A PART I (BUILDING WORKS)
Construction of a building for containing Power House/Control room , rest room and toilet etc complete all as specified and as shown in drawings.
Sch A Part II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II.
Sch A Part III (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY, as listed in Sch ‘A’ Part- III .
Sch A Part IV( INTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION, as listed in Sch ‘A’ Part-IV.
Sch A Part V( EXTERNAL ELECTRIFICATION)
Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION, as listed in Sch ‘A’ Part-V.
Sch A Part VI (ROAD/PATH & CULVERT)
Lump sum price worked out by the contractor for ROAD/PATH & CULVERT ,as listed in Sch ‘A’ Part- VI.
Sch A Part VII (AREA DRAINAGE)
Lump sum price worked out by the contractor for AREA DRAINAGE ,as listed in Sch ‘A’ Part- VII.
Sch A Part VIII (COMPOUND WALL/ GATE)
Lump sum price worked out by the contractor for COMPOUND WALL/ GATE ,as listed in Sch ‘A’ Part- VIII.
Sch A Part IX (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for SEWAGE DISPOSAL as listed in Sch ‘A’ Part- IX.
Sch A Part X ( RAIN WATER HARVESTING)
Lump sum price worked out by the contractor for RAIN WATER HARVESTING as listed in Sch ‘A’ Part- X .
Sch A Part XI ( SITE CLEARANCE, EXCAVATION AND EARTH WORK)
Lump sum price worked out by the contractor for SITE CLEARANCE, EXCAVATION AND EARTH WORK as listed in Sch ‘A’ Part- XI .
Sch A Part XII (SOLAR POWER GENERATOR & MISCELLANEOUS ITEMS)
Design, supply, install, testing and commissioning of ground based solar power generating system without battery of capacity 1.5 MW AC output , peak grid tied solar photo voltaic system complete with the components specified below. Design shall be done from MNRE approved channel partners of Rating as specified in NIT and according to latest IS/IEC code and MNRE latest guidelines and specifications tentatively as shown in Drgs. Final design & Drgs of the subject work has to be vetted by any one of the following approved agencies: - (i) National Institute of Solar Energy (ii) Sardar Swarn Singh National Institute of Renewable Energy (iii) Solar Energy Corporation of India (iv) The Indian Renewable Energy Development Agency :-
(a) Solar PV modules of minimum rating 335Wp with minimum 72 cells, Poly Crystalline Module shall be certified as per IEC 61215-Edition -II, IEC 61646 and IEC 61730-1 & 2 complete all as specified. Qty of solar PV module shall be tentatively 5373 Nos for 1.5 MW AC output. Note :- (i) Each PV module used in this work shall have RF identification tag. (ii) Solar PV Modules: Modules shall be warranted for a minimum period of 25 years. PV modules shall be warranted for their output peak watt capacity, which shall not be less than 90% at the end of 10 years and 80% at the end of 25 years. PV modules shall be warranted for any manufacturing defect or bad workmanship for a period of 25 years from the date of completion of Phase-I of the work. The contractor shall submit necessary warranty certificate for 25 years to GE. The condition 46 of IAFW 2249 shall be amended to the extent as mentioned above. (iii) Modules should be in conformity of latest technical specification issued by MNRE from time to time and makes as approved by MNRE. (iv) An amount equal to Rs. 5,00,000(Rupees Five Lakh Only) shall be retained from the contractor’s bill against the warranty as performance guarantee for a period of 5 years from date of completion of job . Alternatively the contractor may give a separate interest bearing security deposit/BGB in favour of GE valid for 05 years. This amount shall be refunded to him by GE after a period of 05 years. under the conditions provided for by the contract and arising solely from faulty materials or workmanship, provided such defective parts are not repairable at site. (v) During the period of warranty the contractor shall remain liable to replace any defective parts that become defective in the plant. (b) Hot dip galvanised MS angle module mounting structure for solar panels of combined capacity1.5 MW,AC output with double pole static structure of suitable size along with concrete grouting for required rigid support as required at site as per OEM/ MNRE Norms recommendations capable to with stand maximum wind load as designed for angle of modules all as required as per site.
(c) Supply, install, testing and commissioning of Central Inverter/PCU, DC to AC (indoor type) of capacity 3x500 kW AC or next higher side capacity suitable for 1.5 MW AC inputs with minimum 4(+/-) load each with SCADA capabilities as specified housed in OEM provided complete. Note :- (i) Power Conditioning Units (PCU): PCUs shall be warranted for minimum period provided by the manufacturer but not less than 5 years. PCUs shall be warranted for any manufacturing defect or bad workmanship for a minimum period of 05 years from the date of completion of Phase-I of the work. The contractor shall submit necessary warranty certificate for 05 years to GE. The condition 46 of IAFW 2249 shall be amended to the extent as mentioned above. (ii). During the period of Warranty the CONTRACTOR shall remain liable to replace any defective parts that become defective in the plant, under the conditions provided for by the contract and arising solely from faulty materials or workmanship, provided such defective parts are not repairable at site. After replacement the defective parts shall be returned to the CONTRACTOR. (d) Supply, install, testing and commissioning of String monitoring/combiner box of type 22 in 1 Out with 10 Amp fuse on positive side, 200 Amp manual DC disconnector switch & 22 Channel monitoring as required at site complete. (e) Supply, install, testing and commissioning of Copper DC String cables of different sizes of suitable size as required at site of Solar grade, including suitable lugs/ male, female connectors etc , UV resistant 1.5 kV DC Cables confirming to IEC IEC 60754-1 & IEC 60754-2, IEC 60332-1, IEC 60332-3-24., IEC 61034, temperature range -40° to +90° C, complete. (f) Supply, install, testing and commissioning of Data monitoring system communication cable RS 485 [screen twisted] as required at site complete. (g) Supply, install, testing and commissioning of Inverter communication Shielded CAT5 cables as required at site complete.
(h) Supply, install, testing and commissioning of Solar Observatory system or Weather Station complete all as specified and directed consisting of following:- (i). Pyranometers: 1 (ii) Rain Guage: 1 (iii). Module Temp Sensor: 4 (iv) Ultrasonic Anemometer: 1 (v) Temp & relative Humidity Meter, digital type: 1 (vi) Solar Panel (35 W) + Battery Bank: 1 (vii) Data Logger: 1 Note : All data shall be recorded chronologically date wise. The data file shall be MS Excel compatible. The data logger shall have internal reliable battery backup to record all sorts of data simultaneously round the clock. All data shall be stored in a common work sheet chronologically. Representation of monitored data shall be in graphics mode and/or in tabulation form. All instantaneous data can be shown in the Computer Screen (i) Supply, install, testing and commissioning of Lightening protection system (2 sets) of Early Streamer Emission type Lightening Spike with 107 m protection at level 3 for Protection ( duy supported by tech literature) against lightning strikes with GI mast of 8.5 Mtrs long with Remote Performance Monitoring System complete all as specified and directed by the Engineer-in-charge and shall have following :- (i) Inverter Data Monitoring (ii) Energy Meter Data Monitoring (iii) Weather Station Monitoring. Qty of lightening arrester shall not be less than 4 Nos including suitable size of copper strip upto earthing test point.
(j) Supply and installation of Earthing shall be provided for string monitoring/combiner box, Inverter, Solar PV module, Array structure, Panels complete entire system complete with suitable size of Copper Cable including Termination acceesaries as required at site & confirming to latest IS/ IEC all as specified and directed. (k) Supply, install, testing and commissioning of Main distribution board Floor Mounted DC Panel, DC Bus, Auxiliary Buses for required load as per site requirement on DC side of inverter complete. (l) Supply, install, testing and commissioning of Main distribution board Floor Mounted AC Panel, AC Bus, Auxiliary Buses for required load as per site requirement on AC side of inverter complete all as specified and directed . (m) Supply, install, testing and commissioning of UPS with battery bank of 5 kVA with 60 minutes backup at 100 % load as per design & specifications for Solar System critical components, Industrial type Onine UPS with static switches for bypass complete. (n) Supply, install, testing and commissioning of UPS distribution board of Floor Mounted UPS DB, indication lamp complete all as required at site. (o) Supply, install, testing and commissioning of Main DC Cables of off sizes as required at site, Aluminium, armoured Cable confirming to EN 50618 complete. (p) Supplying, laying, testing and installation of LT Power Cable inverter to transformer of AC Cables of off sizes as required at site, 1.1kV Al Armoured LT cable as per IS 7098 complete all as specified and directed. (q) Supplying, laying, testing and installation of LT Aux (DC & AC) control cables for UPS input, transformer, Inverter, panels of suitable size, 1.1kV copper LT cable as per relevant IS complete all as specified and directed. (r ) Supply & fixing earth continuity conductor or main earthing lead copper cable or GI strip of suitable size as required at site. (s) Metering Arrangements:- Suitable dual metering arrangements digital type with recording facility shall be provided. The metering arrangements shal;l be have features to measures to measure and record as below:- (i) Parameters of current generatin, voltage, current, power factor and energy. (ii) Total energy generated by the system since installation. (iii) Energy being consumed in house for meeting the electrical loads. (iv) Any other metering required to determine efficiency and efficiency of the system.
(t) Supply, install, testing and commissioning of Industrial type computer (one No.) rugged & robust in nature to operate in a hostile environment. The computer shall be of HP make or of equivalent make having i5 or better processor with minimum 1 TB of hard drive, 21" LCD colour monitor, DVD Drive with writer, multimedia kit and UPS with 30 min Power back up as per HP model 23 q141in or technocommercially equivalent model. (u) Supplying and laying of Suitable size HDPE pipe 6kgf/cm2 rating for cable protection including all necessary fittings and fixing arrangement complete as required at site all as specified and directed. Note:- Necessary earth work, sand cushioning, protection pipe, bricks etc shall deemed to be included for laying of cables, HDPE pipe up to power transformer. (v) Supply black and white laser printer (one No) as per HP model number M1005 or technocommercially equivalent model in other make as approved by GE. The printer shall be equipped for printing, scanning, copying and fax complete. (w) M & L for Earthing with 600 X 600 X 6.00 mm Galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5 m below ground level, connected to and including Galvanised steel Strip of size 32 X 6 mm by means of bolts, nuts and check nuts and washers of galvanised steel with and including 40 mm dia GI medium grade pipe for protection of GI strip to the extent of 7.5 metres as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per Electrical Plate No. 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover with provision of locking arrangement and 20 mm dia medium grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal of excavated material from the site complete all as specified and directed. Note:- Nos of earthings shall be provided as required at site as per IE/IEC rule.
(x) M & L for Earthing with copper earth plate 600x600x3mm, earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5 m below ground level, connected to and including copper earth strip 25x3 mm by means of bolts, nuts and check nuts and washers of copper with and including 40 mm dia GI medium grade pipe for protection of copper strip to the extent of 7.5 metres as earthing lead all as per Electrical Plate No. 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover with provision of locking arrangement and 20 mm dia medium grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, complete including excavation and earthwork in any type of strata and testing complete including fill up the earth pit with soil for best result and removal of excavated material from the site complete. Note :- Nos of earthings shall be provided as required at site as per IE/IEC rule. (y) Supply, install, testing and commissioning of Surge Protection device complete all as specified and directed. (z) Supply, installation, testing and comissioning of Inverter duty step up transformer of 2000 KVA (copper wound outdoor type) or nearest size on heigher side, 0.30/11 KV per IS -1180 or as per latest IS as amended complete all as specified and directed.-01 in Nos Note :- (i). First fill of oil as per manufacturer instructions shall deemed to be included in the unit rate quoted by contractor. (ii). Plinth for transformer including 40mm to 100 mm graded stone metal aggregate 1.5m wide and upto 3m deep around transformer plinth with and including slant slot for accomodating 100 mm dia pipe on both LT & HT side with clamping arrangement of size and specifications as per manufacturer instructions, shown on drawings and as directed by the Engineer-in-charge complete shall deemed to be included in the unit rate quoted by contractor .
Supply, installation, testing and comissioning Isolation Transformers 3phase, 500 KVA of specification conforming to IS 2026-2011 & IS 335:1993. Qty- 03 Nos.
Supply and laying sub class 'B' bricks in cable trenches as cable protection complete all as specified and directed (For LT Cable only)
Supply, installing, testing and commissioning of HT 11 KV , 3 Phase,50 Hz, indoor type, totally enclosed metal clad switchgear complete with stand alone Vacuum Circuit Breaker (VCB) having rupturing capacity 250 MVA, Over load and Earth Fault protection, Ammeter, Volt Meter and rating up to 400 Amps and both side extendable including necessary battery bank with charging arrangement complete all as specified and as directed by Engineer-in-Charge and of following specifications :-
(a) Motorised spring charging mechanism with 24 volt DC universal motor 200 watts and having charging time less than 5 seconds. (b) Earthing Switch rated for full making capacity with provision for safe & reliable position indicator c) i) Assembly of Vacuum Circuit Breaker shall be completely insulated as per the relevant IS. ii) The rating of VCB shall be 11 KV,400 Amps, 21 KA (for 3 Sec) , 50 Hz, 3 phase. iii) The vacuum interrupture bottle shall have to be manufactured by the OEM. iv) Electrically charged and electrically operated independent closing / tripping, trip free, operating mechanism including manual closing / tripping push button and breaker close / open option shall have to provided. v) One bus Bar Chamber including a set of 3 phase 600 Amps copper bus Bars to be provided for further extension in future, if necessary. vi) Strip Heaters to be provided with the following specifications :- Power input 80 watts with Voltage rating 230 volts AC Single phase vii) Current Transformer (CT) chamber comprising of 3 Nos, single phase resin cast / ring core CTs of 200-100 / 1, burden not less than 2,5 VA and accuracy class 1.0, for metering, having class SP10 for protection as per IS:2705 for each circuit breaker - 02 Sets. viii) 1 No. Potential Transformer (PT), 3 phase, dry type (resin cast) fixed type 11 KV / 110 Volts, Burden 50 VA, Accuracy class 1.0 with HT & LT HRC fuses for primary and secondary complete all as specified and as directed as per IS: 3156 - 01 Set
ix) SCADA compitable self powered numerical over current & earth fault relay for complete protection of HT ,11 KV,3 Phase feeder having facility to record fault current with MODBUS communicationon RS 485 communication port - 01 No including 1 No voltage monitoring relay for under voltage / over voltage protection. Make : AREVA / ABB / SCHNEIDER / SIEMENS / ASHIDA / CSDPR x) Digital SCADA compitable meter of accuracy class 1, as per IEC 62052-11 / IEC 62053-22 monitoring all electrical parameters like votage, current, demand, Watt, VA, VAR per phase. Also to monitor all instanteneous integrated demand,parameters, neutral current, frequency,power factor, % load, % unbalance (V&I), phase angle, THD working on MODBUS protocol. Make : L&T / SCHNEIDER / RISHABH / ELMEASURE xi) One set of mechanical indicatior for ON / OFF indication for all LBS / VCB breaker. xii) One set of capacitive voltage indication for R-Y-B xiii) One set of battery and battery charger to provide suitable back up as per OEM's instruction Make : ABB / SCHNEIDER / AREAVA / SIEMENS
Supplying,installation,testing and commissioning 11 KV current transformer of cast resin type 11 KV current transformer having ratio of 100+50/5 A having protection core class 5P10, burden of 15 VA and metering core class 1.0 and burden of 15 VA breaking cap of 21.1 KV for 1.0 second Make : KAPPA / AE / TECHNO ASSOCIATES VIDYUT (P) Ltd, Thane / L.R. Enterprises / ARIHANT Electricals
Supplying,installation,testing and commissioning 11 KV single phase indoor resin cast PT of ratio (11KV / √3) / (110V / √3) class 0.5 burden not less than 50 VA having insulation class-E , insulation level 12KV/28KV/75 KV,conforming to IS- 3156 including fixing in HT metering Box complete all as specified and directed.( for energy meter ) Make : KAPPA / AE / TECHNO ASSOCIATES VIDYUT (P) Ltd, Thane / L.R. Enterprises / ARIHANT Electricals
Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar of overall size not less than 1500mm width x 750mm Height (Without Canopy & Base Channel) x 300mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 100 amps, Provision of Spreader link to incoming side of MCCBs. For termination of outgoing cables with MCBs, 4 way ebonite cable connector (rating 32 amps) to be provided .TheFeeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :- Location : Main LT Feeder Pillar
PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided in the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant,high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 100 amps, . For all internal connections from main bus bars to switch gears shall be carried out with suitable size FRLS grade PVC insulated multiflexible type copper wire as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mm INCOMING :- 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 16 KA Fixed magnetic and Fixed thermal setting of rating 63 Amps - 01 No. Make : LEGRAND /SCHNEIDER / ABB OUTGOINGS :- TPN MCB 32 Amps having breaking capacity 10 KA - 06 Nos Make : LEGRAND /SCHNEIDER / ABB
Supply and fixing thermoplastic polystyrene / polycarbonate enclosure of overall size 210mm x 155mm x 92mm suitable for street light junction box, shock proof , vermin proof and dust proof complete with terminals for up to 3 phase cable of size 16 Sq mm 4 core and 01 No MCB SP 6 amps including non metalic clapms and GI nut bolts and washers of suitable size and fixed on pole / wall complete and making cable connection as existing all as specified and directed. Make of Box : HENSEL(Cat No : DK1616G) OR Equivallent model in RITTAL / GEWIS Make of MCB : Legrand / Schneider / ABB /L&T
Supply and fixing LED street light fitting 60 - 65 watt complete with Pressure die cast aluminum housing enclosed with glass cover in frame complete and making electrical connection with using copper conductor 23/ 0.0076 round PVC insulated and sheathed three core cable including mounting bracket made out of 40mm bore light grade GI pipe with suitable size clamp made of 25mm x 5 mm MS Flats, MS nuts,bolts, washers and over voltage protection up to 300 volts complete of 60 watt , inbuilt 5 KV surge protection with 20 KV SPD complete all as directed. Make : CROMPTON (Cat Part No. LSTO-60-CDL) / HAVELLS (Cat Part No. ENDURAPEARLPLUSSL60WLED757SASYTOPC) / PHILIPS (Cat Part No. BRP062 LED 65 CW SLA S1 PSU)
Design, supply, erection, testing and commissioning of outdoor type Street Light Controller Panel of overall size not less than 500mm width x 600mm Height (Without Canopy & Base Channel) x 300mm Depth, M.S. Channel Base Frame mounted (to be mounted through grouting bolt on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply. The panel shall be duly fabricated in an approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with2 layer shutter in the front side and single layer shutter in the rear side with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts. The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. Following internal components shall have to be provided duly mounted on a mounting plate :- Location : Security Light Controller Panel
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and including HDPE pipe of up to 150 mm dia suitable for 0.4 mpa working pressure
Design, supply, erection, testing and commissioning of outdoor type Bus Bar Chamber of overall size not less than 500mm width x 500mm Height (Without Canopy & Base Channel) x 300mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 900mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 100 Amps for cable termination, The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication house who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre-treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom and 2 Nos Earthing Termination bolts, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation.
Supply and fixing LED flood light fitting suitable fixing on watch Tower including all fixing arrangement high grade aluminium pressure die cast and toughened glass, minimum lumen efficacy 100 lumen/watt and high spread using high quality lenses and reflector including over voltage protection up to 300 volts complete of 110-120 watt , inbuilt surge protection of 5 KV Make Havells (Cat No.JETAIRISFLS120WLED757ASYMLTG) / Crompton (Cat No.LFLN-120-CDL/60) / Philips (Cat No. BVP192LED110 CW HO NB FG GR PSU)
M&L for construction of brick masonary Valve Pit (wall thickness 230mm) having internal dimension 600mm x 600mm x600mm including necessary earth work , 100mm thick P.C.C. (1:3:6 Type C2) as in foundation, brick work in cement morter 1:6, 15mm thick plastering in cement morter 1:4 both in entire internal & external surfaces (upto 15cm below ground level), 3.15mm M.S. sheet cover duly hinged with M.S. angle framework made with M.S. angle of size 40mmx40mmx5mm with locking facility. The M.S. part shall be painted with two coats of Black Bitumenous paint over a coat of Red Oxide Metal Primar and Two Coats of Limewash shall have to be done on the exposed surfaces of the brick work .
S&F Monoblock type Centrifugal Pump Set of capacity 5 hp, suitable for operation with AC 3 Phase,415 Volts, 50 Hz supply. Make : KIRLOSKAR BROTHERS ( Model :KDS 515 +) or Equivallent Model in CRI / CROMPTON
S&F Brass / Bronze Check Valve , 50 mm bore, screwed for fixing with GI Pipe complete all as specified and directed.
M & L for Construction of Septic Tank for 10 users , including necessary earth work in excavation in any type of soil , plain cement concrete 1:2:4 type B-2 ( using 40 mm graded crushed stone aggregate ) as in foundation , brick work in cement mortar 1:4 , ,reinforced cement concrete M-25 ( design mix) as in slab cover including pre-cast man hole cover slab with reinforcemement complete all as shown on drawings No.217 sheet 1/2 & 2/2 all as specified & directed at site by Eng-in-Charge.
M & L for Construction of Soakage well for 1.20 m dia( internal dia ) & 3.00 m depth including necessary earthwork in excavation in earth work in any type of soil ,brick work in cement mortar 1:4 in RCC cover slab including pre-cast man hole cover slab with reinforced, complete all as shown in drawing No. TD-576 sheet 1/2 & 2/2 all as specified and directed at site by Engr-in-Charge.
Dismantling of concertina coil of any size complete all as specified and directed
S&F in diamond shape high strength steel punched tape concertina coil 600mm dia (in specified and standard stretched position) hot dip galvanized coated with CLR anti corrosive paint by making diamond shape with the help of dove tail clips (18 swg) fixed over razor wire with the help of hog rings(14 SWG) in angle iron bracket/frame over boundary wall etc complete all as specified and as directed. (Note: Razor wire and angle iron frame/bracket shall be measured and paid seperately)
M&L for earthing with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to GI wire of size 4 mm as earthing lead means of nut, bolts and washers made out of galvanised iron mild steel and 15 mm dia GI pipe "medium grade" for protection of earth lead and connected to Neutral point of Transformer / Voltage Stabilizer etc, or as directed by Engr -in-Charge including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Agg-regate) and RCC Cover of size 450X450X50 mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion including Taking down Unserviceable Earthing, complete all as specified and as directed. (To be used for pole earthing)
M&L for earthing with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground vertically to a depth of not less than 2.25 mtr below ground level connected to GI strip of size 32 x 6 mm as earthing lead means of nut, bolts and washers made out of galvanised iron mild steel and 40 mm dia GI pipe "medium grade" for protection of earth lead and connected to Neutral point of Transformer / Voltage Stabilizer etc, or as directed by Engr -in-Charge including PCC Pit in Cement Concrete 1:3:6 (20mm Graded Stone Agg-regate) and RCC Cover of size 450X450X50 mm in RCC 1:2:4 (20mm Graded Stone Aggregate) rein-forced with and including 8.0mm dia TMT Bars @ 100mm centre to centre both ways, Galvanised Iron Wire Mesh, Funnel, Galvanised Iron Watering Pipe 20mm Bore (dia) Medium Grade, necessary Excavation in Soft/ Loose Soil, returning, filling in and removal of surplus Spoil upto a distance of 50.00 METRE and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on completion including Taking down Unserviceable Earthing, complete all as specified and as directed. (To be used for Equipment earthing)
M&L for making connection with PVC insulated multistranded copper conductor cable(FRLS) with 2.5 Sqmmx 3 run(2+1 for earth wire) including PVC conduit suitable size from street light fitting to looping box complete all as specified and directed.
Services for Comprehensive maintenance, operation and repair of Solar power plant for 55 months (including one year defect liability period) in two shift including Saturday, Sunday & holidays after completion of project as per conditions of contract including the following :-
Outsourcing services for Comprehensive maintenance, operation and repair of Solar power plant for 55 months (including one year defect liability period) in two shifts including Saturday, Sunday & holidays after completion of project as per conditions of contract including the following :- (i) The Work order for outsourcing of services shall be placed for eleven months & no price adjustment for its extension shall be permissible. The Solar Power Plant shall be operated in 02 shifts per day unless otherwise directed by the Engr-in-charge/GE. (ii) The contractor shall deploy minimum tradesman as follows :- (aa) One trained Electrician and one helper in each shifts for attending/ monitoring the breakdown and preventive maintenance. Note: Penalty Clause:- If the installation (Solar Power Generation Station) is not operated by the electrcian and helper or found absent from duty the penalty for this lapse shall be final and biding as under:- Skilled Electrician:- Double the rate of minimum wages published by the GOI during the absent period. Helper:- Double the rate of minimum wages published by the GOI during the absent period. . (iii) The electrician must have ITI in Electrical and having experience of 02 Years in operation & maintenance of solar power plant and familiar with SCADA operating system, weathering monitoring system, HT/LT installation and security and safety features complete. The Necessary technical qualification certificate shall be produced for verification of Engr-in-charge & get the written approval on record before deploying for works. (iv) Contractor shall offer service for entire system as per maintenance schedule as directed by GE in presence of Engineer in charge/JE and maintain necessary record for the same. (v) Contractor shall also ensure the following :- (aa) Servicing of all solar equipment’s, HT / LT control system, Transformers weather monitoring equipment’s, SCADA system etc all as per OEM recommendations.
First 11 Months
Second 11 Months
Third 11 Months
Fourth 11 Months
Fifth 11 Months
S&F wall/ceiling mounted LED light fitting 1x20 Watt LED which provides diffused light and glare free with LED driver 20 W complete fitting, etc with all accessories prewired and connected with 23/0.0076 three core PVC flexible cable etc all as specified and directed:- Make- Havells Cat part No. STOUMINI1200BS20WLED865SPCWH or euivalent in Cromptonm/ Philips.
S&F building security LED light fitting 1x25 Watt LED which provides diffused light and glare free with LED driver 25 W complete fitting, etc with all accessories prewired and connected with 23/0.0076 three core PVC flexible cable including GI bracket of suitable size and length, fixing accessories fastneres, nut blts washers, clamp etc all as specified and directed:- Make- Havells Cat part No. ENDURAPEARLSL25WLED757SASTOPCMP or euivalent in Cromptonm/ Philips.
S&F CEILING FAN 1200 MM SWEEP, energy saving five star rated, single phase, 230 Volts, 50 Hz including providing, fixing and connecting of regular electronic step type-01, complete all as directed. Make:- Havells model No. ES-50 S or equivalent in Crompton/Philips.
S&F Air Ventilating fan 300 mm dia metalic body single phase 230 volts 900 rpm including fixing and connecting the fan with 3 core PVC insulated and over all sheathed flexible copper conductor cable from ceiling rose/PVC connector to exhaust fan including making suitable hole in wall, and make good disturbed surface of wal including louvers of suitable size, fastners, nut, bolts etc complete all as specified and directed by Engg-in-Charge. Make:- Havells, Model-Venti Air-DB or equivalent in CG/Philips/USha/Bajaj.
M&L for drilling/boring vertical bores with reverses rotary rig or any other suitable methods as per latest engineering technology practice without casing pipe with 202 mm dia bit to a depth not exceeding 50 m beow ground level including all necessary work required for boring and filling of pea gravels all around the owered pipe etc complete all as specified and directed by Engr-in-Charge. Note:- BOQ Item No. 12.48 to 12.55 are miscellaneous items pertains to rain water harvesting.
M&L for pea gravels of size 5 to 10 mm for filing in bore hole and recharge well over the exsting layer of boulders in reqd thickness for all leads & lifts complete all as specified and directed by Engr-in-Charge.
M&L for coarse sand of size 1.5 to 2mm for filling in recharge well in reqd thickness over gravel layer for all leads and lifts complete all as specified and directed by Engr-in-Charge.
M&L for stone boulder 100 to 200 mm for filling in recharge well reqd thickness for all leads and lifts complete all as specified and directed by Engr-in-Charge.
S&F UPVC pipe 110mm outer dia including fittings etc placed in bore holes complete all as specified and as directed by Engr-in-Charge.
All as per items No 12.52 above but slotted pipe (ribbed screen complete all as specified and directed.
M&L for Nylon newer covering to 110 mm outer dia UPVC slotted pipe complete all as specified and as directed by Engr-in Charge.
S&F bail plug/ bottom plug of 110 mm dia to the bottom of pipe assemble complete all as specified and directed by Engr-in-Charge
S&F Non return Valve (NRV) of 50mm bore complete all as specified and directed at site by Engr-in-Charge.
Shalaka Infra-Tech ( I ) Pvt. Ltd.
FRIZO INDIA PVT LTD
LUMOS INFRA PVT LTD
Phoenix Infra
SVC PROJECTS PVT. LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid